CTRON-CHASSIS-MIB
Standard SNMP MIB module defining data structures for CTRON-CHASSIS-MIB.
Imported Objects
Objects
17 total| Object Name |
|---|
ctChas OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.3.1.1 |
CTRON-MIB-NAMES Unknown .1.3.6.1.4.1.52.4.3.1.1 |
ctChasFNBro Enumeration .1.3.6.1.4.1.52.4.3.1.1.1 |
ctChasAlarmEnarw Enumeration .1.3.6.1.4.1.52.4.3.1.1.2 |
chassisAlarmStatero Enumeration .1.3.6.1.4.1.52.4.3.1.1.3 |
ctEnviron OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.3.1.2 |
ctChasPowerTable SEQUENCE OF CtChasPowerEntry .1.3.6.1.4.1.52.4.3.1.2.1 |
ctChasPowerEntry CtChasPowerEntry .1.3.6.1.4.1.52.4.3.1.2.1.1 |
ctChasPowerSupplyNumro INTEGER .1.3.6.1.4.1.52.4.3.1.2.1.1.1 |
ctChasPowerSupplyStatero Enumeration .1.3.6.1.4.1.52.4.3.1.2.1.1.2 |
ctChasPowerSupplyTypero Enumeration .1.3.6.1.4.1.52.4.3.1.2.1.1.3 |
ctChasPowerSupplyRedundancyro Enumeration .1.3.6.1.4.1.52.4.3.1.2.1.1.4 |
ctFanModule OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.3.1.3 |
ctChasFanModuleTable SEQUENCE OF CtChasFanModuleEntry .1.3.6.1.4.1.52.4.3.1.3.1 |
ctChasFanModuleEntry CtChasFanModuleEntry .1.3.6.1.4.1.52.4.3.1.3.1.1 |
ctChasFanModuleNumro INTEGER .1.3.6.1.4.1.52.4.3.1.3.1.1.1 |
ctChasFanModuleStatero Enumeration .1.3.6.1.4.1.52.4.3.1.3.1.1.2 |
CTRON-CHASSIS-MIB Technical Reference Overview
The CTRON-CHASSIS-MIB SNMP MIB module published by Cabletron defines 17 managed OID objects, including 10 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events. Key tabular structures include ctChasPowerTable, ctChasFanModuleTable.
Key OID Definitions in CTRON-CHASSIS-MIB
.1.3.6.1.4.1.52.4.3.1.2.1A list of power supply entries.
.1.3.6.1.4.1.52.4.3.1.3.1A list of fan module entries.
.1.3.6.1.4.1.52.4.3.1.1.1Denotes the presence or absence of the FNB.
.1.3.6.1.4.1.52.4.3.1.1.2Allow an audible alarm to be either enabled or dis- abled. Setting this object to disable(1) will prevent an audible alarm from being heard and will also stop the sound from a current audible alarm. Setting this object to enable(2) will allow an audible alarm to be heard and will also enable the sound from a current audible alarm, if it has previously been disabled. This object will read with the current setting.
.1.3.6.1.4.1.52.4.3.1.1.3Denotes the current condition of the power supply fault detection circuit. This object will read with the value of chassisNoFaultCondition(1) when the chassis is currently operating with no power faults detected. This object will read with the value of chassisFaultCondition(2) when the chassis is currently in a power fault condition.
.1.3.6.1.4.1.52.4.3.1.2.1.1An entry in the powerTable providing objects for a power supply.
.1.3.6.1.4.1.52.4.3.1.2.1.1.1Denotes the power supply.
.1.3.6.1.4.1.52.4.3.1.2.1.1.2Denotes the power supply's state.
.1.3.6.1.4.1.52.4.3.1.2.1.1.3Denotes the power supply type.
.1.3.6.1.4.1.52.4.3.1.2.1.1.4Denotes whether or not the power supply is redundant.
.1.3.6.1.4.1.52.4.3.1.3.1.1An entry in the fan module Table providing objects for a fan module.
.1.3.6.1.4.1.52.4.3.1.3.1.1.1Denotes the Fan module that may have failed.
.1.3.6.1.4.1.52.4.3.1.3.1.1.2Denotes the fan modules state.
More MIBs from Cabletron
Browse all CabletronMIBs →SNMP MIB module
Standard SNMP MIB module defining data structures for CTRON-SFCS-MIB.
Standard SNMP MIB module defining data structures for CABLETRON-TRAPS.
SNMP MIB module
Standard SNMP MIB module defining data structures for ADIC-SANMGR-PROXY-MIB.
The CTRON-AP3000-MIB module enables read-write SNMP configuration management for Enterasys AP3000 wireless access points under the Enterasys enterprise OID. It provides programmatic access to device-specific operational parameters and settings required for provisioning and maintaining the AP3000 hardware.