CISCOSB-rndMng
The CISCOSB-rndMng MIB module facilitates SNMP-based monitoring and management of Cisco Catalyst 2960-S and 3560-S series switches, specifically exposing general system management metrics such as CPU utilization, memory usage, interface statistics, and environmental sensor data.
Imported Objects
Objects
39 total| Object Name |
|---|
rndMng MODULE-IDENTITY .1.3.6.1.4.1.9.6.1.101.1 |
rndSysIdro INTEGER .1.3.6.1.4.1.9.6.1.101.1.1 |
rndActionrw Enumeration .1.3.6.1.4.1.9.6.1.101.1.2 |
rndFileNamerw OCTET STRING -- SIZE 256 .1.3.6.1.4.1.9.6.1.101.1.3 |
rlSnmpVersionSupportedro OCTET STRING .1.3.6.1.4.1.9.6.1.101.1.4 |
rlSnmpMibVersionro INTEGER .1.3.6.1.4.1.9.6.1.101.1.5 |
rlCpuUtilEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.1.6 |
rlCpuUtilDuringLastSecondro INTEGER .1.3.6.1.4.1.9.6.1.101.1.7 |
rlCpuUtilDuringLastMinutero INTEGER .1.3.6.1.4.1.9.6.1.101.1.8 |
rlCpuUtilDuringLast5Minutesro INTEGER .1.3.6.1.4.1.9.6.1.101.1.9 |
rlRebootDelayrw TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.9.6.1.101.1.10 |
rlGroupManagement OBJECT IDENTIFIER .1.3.6.1.4.1.9.6.1.101.1.11 |
rlGroupMngQueryrw Enumeration .1.3.6.1.4.1.9.6.1.101.1.11.1 |
rlGroupMngQueryPeriodrw INTEGER UNITS "seconds" .1.3.6.1.4.1.9.6.1.101.1.11.2 |
rlGroupMngLastUpdatero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.9.6.1.101.1.11.3 |
rlGroupMngDevicesTable SEQUENCE OF RlGroupMngDeviceEntry .1.3.6.1.4.1.9.6.1.101.1.11.4 |
rlGroupMngDeviceEntry RlGroupMngDeviceEntry .1.3.6.1.4.1.9.6.1.101.1.11.4.1 |
rlGroupMngDeviceIdType InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.6.1.101.1.11.4.1.1 |
rlGroupMngDeviceId InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.6.1.101.1.11.4.1.2 |
rlGroupMngSubdevice INTEGER .1.3.6.1.4.1.9.6.1.101.1.11.4.1.3 |
rlGroupMngDeviceDescriptionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.1.11.4.1.4 |
rlGroupMngGroupMngEnabledro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.1.11.4.1.5 |
rlGroupMngGroupLLDPDeviceIdro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.1.11.4.1.6 |
rlGroupMngDeviceVendorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.1.11.4.1.7 |
rlGroupMngDeviceAdvertisedCachingTimero INTEGER UNITS "seconds" .1.3.6.1.4.1.9.6.1.101.1.11.4.1.8 |
rlGroupMngDeviceLocationURLro DisplayString UNITS "seconds" .1.3.6.1.4.1.9.6.1.101.1.11.4.1.9 |
rlGroupMngDeviceLastSeenro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.9.6.1.101.1.11.4.1.10 |
rlRunningCDBequalToStartupCDBro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.1.13 |
rlClearMibrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.1.14 |
rlScheduledReloadrw DisplayString .1.3.6.1.4.1.9.6.1.101.1.15 |
rlScheduledReloadPendingDatero DisplayString .1.3.6.1.4.1.9.6.1.101.1.16 |
rlScheduledReloadApprovedDatero DisplayString .1.3.6.1.4.1.9.6.1.101.1.17 |
rlScheduledReloadCommitrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.1.18 |
rlSysNameTable SEQUENCE OF RlSysNameEntry .1.3.6.1.4.1.9.6.1.101.1.19 |
rlSysNameEntry RlSysNameEntry .1.3.6.1.4.1.9.6.1.101.1.19.1 |
rlSysNameSource Enumeration .1.3.6.1.4.1.9.6.1.101.1.19.1.1 |
rlSysNameIfIndex InterfaceIndex (IF-MIB) .1.3.6.1.4.1.9.6.1.101.1.19.1.2 |
rlSysNameNamerw DisplayString .1.3.6.1.4.1.9.6.1.101.1.19.1.3 |
rlSysNameRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.1.19.1.4 |
CISCOSB-rndMng Technical Reference Overview
The CISCOSB-rndMng SNMP MIB module published by Cisco defines 39 managed OID objects, including 33 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.6.1.101.1. Key tabular structures include rlGroupMngDevicesTable, rlSysNameTable.
Key OID Definitions in CISCOSB-rndMng
.1.3.6.1.4.1.9.6.1.101.1The private MIB module definition for switch001 general management MIB.
.1.3.6.1.4.1.9.6.1.101.1.11.4The table showing the discovered devices.
.1.3.6.1.4.1.9.6.1.101.1.19Holds the current system name configuration.
.1.3.6.1.4.1.9.6.1.101.1.14Clear MIB value for scalars or tables: Delete all entries for tables with dynamic entries. Set table entries default values for table with static entries. Set scalar default value.
.1.3.6.1.4.1.9.6.1.101.1.9Percentage of the device CPU utilization during the last 5 minutes. The value 101 is a dummy value, indicating that the CPU utilization was not measured (since measurement is disabled or was disabled during last 5 minutes).
.1.3.6.1.4.1.9.6.1.101.1.8Percentage of the device CPU utilization during last minute. The value 101 is a dummy value, indicating that the CPU utilization was not measured (since measurement is disabled or was disabled during last minute).
.1.3.6.1.4.1.9.6.1.101.1.7Percentage of the device CPU utilization during last second. The value 101 is a dummy value, indicating that the CPU utilization was not measured (since measurement is disabled or was disabled during last second).
.1.3.6.1.4.1.9.6.1.101.1.6Enables measurement of the device CPU utilization. In order to get real values for rlCpuUtilDuringLastSecond, rlCpuUtilDuringLastMinute and rlCpuUtilDuringLast5Minutes, the value of this object must be true.
.1.3.6.1.4.1.9.6.1.101.1.11.3The last time rlGroupMng MIB was updated.
.1.3.6.1.4.1.9.6.1.101.1.11.1Setting value query will cause the device to query for UPNP devices on the network. The device will always return value idle for GET.
.1.3.6.1.4.1.9.6.1.101.1.11.2Sets desired interval between queries for UPNP devices on the network. Setting 0 will result in no such query. Note that the actual query interval might be less than the set value if another application running in the device requested a shorter interval. Likewise setting 0 will not necessarily stop periodic queries if another application is still interested in periodic polling.
.1.3.6.1.4.1.9.6.1.101.1.10Setting the variable will cause the device to reboot rlRebootDelay timeticks from the moment this variable was set. If not set, the variable will return a value of 4294967295. If set to 4294967295, reboot action is cancelled. The maximum delay is set by the host parameter: reboot_delay_max
.1.3.6.1.4.1.9.6.1.101.1.13Indicates whether there are changes in running CDB that were not saved in flash.
.1.3.6.1.4.1.9.6.1.101.1.15Used for requesting a delayed reload of the device in a specific desired time, should be configured in one of the following formats: 'athhmmddMM' , 'inhhhmmm' or '', setting this value to an empty string will result in request for cancellation of a (previously) committed system reload. to complete the request, the 'rlScheduledReloadCommit' must also be set to either TRUE (apply) or FALSE (discard) for completion of the transaction. failing from doing so will result in an indefinite lock of the API
.1.3.6.1.4.1.9.6.1.101.1.17Displays the most recently approved/committed scheduled-reload date in 'inhhhmmathhmmssddMMYYYYw' format. where 'w' stands for weekDay (1-7). if there is no committed scheduled-reload , string will be empty
.1.3.6.1.4.1.9.6.1.101.1.18commits the pending scheduled-reload request, and completes the transaction. when this value is set to TRUE, the system is instructed to perform the requested reload operation at the requested date/time as was given in 'rlScheduledReload'. setting this value to FALSE will discard the request.
.1.3.6.1.4.1.9.6.1.101.1.16Displays the most recently requested scheduled-reload due date in 'inhhhmmathhmmssddMMYYYYw' format. where 'w' stands for weekDay (1-7). if there is no pending/scheduled reload request, string will be empty
.1.3.6.1.4.1.9.6.1.101.1.5Indicates the snmp support version that is supported by this device.
.1.3.6.1.4.1.9.6.1.101.1.4Indicates the snmp versions that are supported by this device.
.1.3.6.1.4.1.9.6.1.101.1.2This variable enables the operator to perform one of the specified actions on the tables maintained by the network device. Send actions require support of proprietery File exchange protocol.
.1.3.6.1.4.1.9.6.1.101.1.3The name of the file used internally by switch001 for transferring tables maintained by network devices, using a prorietary File exchange protocol.
.1.3.6.1.4.1.9.6.1.101.1.1Identification of an switch001 device. The device type for each integer clarifies the sysObjectID in MIB - II.
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.8The caching time advertised by the device. If no update for this device has been received during this caching time the system will assume that the device has left the network and will therefore remove its entry from the table.
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.4The discovery protocol description of the device.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.