Home/Catalog/CISCOSB-rndMng

CISCOSB-rndMng

AI MIB Summary

The CISCOSB-rndMng MIB module facilitates SNMP-based monitoring and management of Cisco Catalyst 2960-S and 3560-S series switches, specifically exposing general system management metrics such as CPU utilization, memory usage, interface statistics, and environmental sensor data.

The private MIB module definition for switch001 general management MIB.
Main OID:
rndMng.1.3.6.1.4.1.9.6.1.101.1
39
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

39 total
Object Name
rndMng
MODULE-IDENTITY
.1.3.6.1.4.1.9.6.1.101.1
rndSysIdro
INTEGER
.1.3.6.1.4.1.9.6.1.101.1.1
rndActionrw
Enumeration
.1.3.6.1.4.1.9.6.1.101.1.2
rndFileNamerw
OCTET STRING -- SIZE 256
.1.3.6.1.4.1.9.6.1.101.1.3
rlSnmpVersionSupportedro
OCTET STRING
.1.3.6.1.4.1.9.6.1.101.1.4
rlSnmpMibVersionro
INTEGER
.1.3.6.1.4.1.9.6.1.101.1.5
rlCpuUtilEnablerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.6.1.101.1.6
rlCpuUtilDuringLastSecondro
INTEGER
.1.3.6.1.4.1.9.6.1.101.1.7
rlCpuUtilDuringLastMinutero
INTEGER
.1.3.6.1.4.1.9.6.1.101.1.8
rlCpuUtilDuringLast5Minutesro
INTEGER
.1.3.6.1.4.1.9.6.1.101.1.9
rlRebootDelayrw
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.9.6.1.101.1.10
rlGroupManagement
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.6.1.101.1.11
rlGroupMngQueryrw
Enumeration
.1.3.6.1.4.1.9.6.1.101.1.11.1
rlGroupMngQueryPeriodrw
INTEGER UNITS "seconds"
.1.3.6.1.4.1.9.6.1.101.1.11.2
rlGroupMngLastUpdatero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.9.6.1.101.1.11.3
rlGroupMngDevicesTable
SEQUENCE OF RlGroupMngDeviceEntry
.1.3.6.1.4.1.9.6.1.101.1.11.4
rlGroupMngDeviceEntry
RlGroupMngDeviceEntry
.1.3.6.1.4.1.9.6.1.101.1.11.4.1
rlGroupMngDeviceIdType
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.1
rlGroupMngDeviceId
InetAddress (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.2
rlGroupMngSubdevice
INTEGER
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.3
rlGroupMngDeviceDescriptionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.4
rlGroupMngGroupMngEnabledro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.5
rlGroupMngGroupLLDPDeviceIdro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.6
rlGroupMngDeviceVendorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.7
rlGroupMngDeviceAdvertisedCachingTimero
INTEGER UNITS "seconds"
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.8
rlGroupMngDeviceLocationURLro
DisplayString UNITS "seconds"
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.9
rlGroupMngDeviceLastSeenro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.10
rlRunningCDBequalToStartupCDBro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.6.1.101.1.13
rlClearMibrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9.6.1.101.1.14
rlScheduledReloadrw
DisplayString
.1.3.6.1.4.1.9.6.1.101.1.15
rlScheduledReloadPendingDatero
DisplayString
.1.3.6.1.4.1.9.6.1.101.1.16
rlScheduledReloadApprovedDatero
DisplayString
.1.3.6.1.4.1.9.6.1.101.1.17
rlScheduledReloadCommitrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.6.1.101.1.18
rlSysNameTable
SEQUENCE OF RlSysNameEntry
.1.3.6.1.4.1.9.6.1.101.1.19
rlSysNameEntry
RlSysNameEntry
.1.3.6.1.4.1.9.6.1.101.1.19.1
rlSysNameSource
Enumeration
.1.3.6.1.4.1.9.6.1.101.1.19.1.1
rlSysNameIfIndex
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.9.6.1.101.1.19.1.2
rlSysNameNamerw
DisplayString
.1.3.6.1.4.1.9.6.1.101.1.19.1.3
rlSysNameRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.6.1.101.1.19.1.4

CISCOSB-rndMng Technical Reference Overview

The CISCOSB-rndMng SNMP MIB module published by Cisco defines 39 managed OID objects, including 33 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.6.1.101.1. Key tabular structures include rlGroupMngDevicesTable, rlSysNameTable.

Key OID Definitions in CISCOSB-rndMng

rndMngMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.6.1.101.1

The private MIB module definition for switch001 general management MIB.

rlGroupMngDevicesTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.6.1.101.1.11.4

The table showing the discovered devices.

rlSysNameTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.6.1.101.1.19

Holds the current system name configuration.

rlClearMibDisplayStringread-write
.1.3.6.1.4.1.9.6.1.101.1.14

Clear MIB value for scalars or tables: Delete all entries for tables with dynamic entries. Set table entries default values for table with static entries. Set scalar default value.

rlCpuUtilDuringLast5MinutesINTEGERread-only
.1.3.6.1.4.1.9.6.1.101.1.9

Percentage of the device CPU utilization during the last 5 minutes. The value 101 is a dummy value, indicating that the CPU utilization was not measured (since measurement is disabled or was disabled during last 5 minutes).

rlCpuUtilDuringLastMinuteINTEGERread-only
.1.3.6.1.4.1.9.6.1.101.1.8

Percentage of the device CPU utilization during last minute. The value 101 is a dummy value, indicating that the CPU utilization was not measured (since measurement is disabled or was disabled during last minute).

rlCpuUtilDuringLastSecondINTEGERread-only
.1.3.6.1.4.1.9.6.1.101.1.7

Percentage of the device CPU utilization during last second. The value 101 is a dummy value, indicating that the CPU utilization was not measured (since measurement is disabled or was disabled during last second).

rlCpuUtilEnableTruthValueread-write
.1.3.6.1.4.1.9.6.1.101.1.6

Enables measurement of the device CPU utilization. In order to get real values for rlCpuUtilDuringLastSecond, rlCpuUtilDuringLastMinute and rlCpuUtilDuringLast5Minutes, the value of this object must be true.

rlGroupMngLastUpdateTimeTicksread-only
.1.3.6.1.4.1.9.6.1.101.1.11.3

The last time rlGroupMng MIB was updated.

rlGroupMngQueryINTEGERread-write
.1.3.6.1.4.1.9.6.1.101.1.11.1

Setting value query will cause the device to query for UPNP devices on the network. The device will always return value idle for GET.

rlGroupMngQueryPeriodINTEGERread-write
.1.3.6.1.4.1.9.6.1.101.1.11.2

Sets desired interval between queries for UPNP devices on the network. Setting 0 will result in no such query. Note that the actual query interval might be less than the set value if another application running in the device requested a shorter interval. Likewise setting 0 will not necessarily stop periodic queries if another application is still interested in periodic polling.

rlRebootDelayTimeTicksread-write
.1.3.6.1.4.1.9.6.1.101.1.10

Setting the variable will cause the device to reboot rlRebootDelay timeticks from the moment this variable was set. If not set, the variable will return a value of 4294967295. If set to 4294967295, reboot action is cancelled. The maximum delay is set by the host parameter: reboot_delay_max

rlRunningCDBequalToStartupCDBTruthValueread-only
.1.3.6.1.4.1.9.6.1.101.1.13

Indicates whether there are changes in running CDB that were not saved in flash.

rlScheduledReloadDisplayStringread-write
.1.3.6.1.4.1.9.6.1.101.1.15

Used for requesting a delayed reload of the device in a specific desired time, should be configured in one of the following formats: 'athhmmddMM' , 'inhhhmmm' or '', setting this value to an empty string will result in request for cancellation of a (previously) committed system reload. to complete the request, the 'rlScheduledReloadCommit' must also be set to either TRUE (apply) or FALSE (discard) for completion of the transaction. failing from doing so will result in an indefinite lock of the API

rlScheduledReloadApprovedDateDisplayStringread-only
.1.3.6.1.4.1.9.6.1.101.1.17

Displays the most recently approved/committed scheduled-reload date in 'inhhhmmathhmmssddMMYYYYw' format. where 'w' stands for weekDay (1-7). if there is no committed scheduled-reload , string will be empty

rlScheduledReloadCommitTruthValueread-write
.1.3.6.1.4.1.9.6.1.101.1.18

commits the pending scheduled-reload request, and completes the transaction. when this value is set to TRUE, the system is instructed to perform the requested reload operation at the requested date/time as was given in 'rlScheduledReload'. setting this value to FALSE will discard the request.

rlScheduledReloadPendingDateDisplayStringread-only
.1.3.6.1.4.1.9.6.1.101.1.16

Displays the most recently requested scheduled-reload due date in 'inhhhmmathhmmssddMMYYYYw' format. where 'w' stands for weekDay (1-7). if there is no pending/scheduled reload request, string will be empty

rlSnmpMibVersionINTEGERread-only
.1.3.6.1.4.1.9.6.1.101.1.5

Indicates the snmp support version that is supported by this device.

rlSnmpVersionSupportedOCTETread-only
.1.3.6.1.4.1.9.6.1.101.1.4

Indicates the snmp versions that are supported by this device.

rndActionINTEGERread-write
.1.3.6.1.4.1.9.6.1.101.1.2

This variable enables the operator to perform one of the specified actions on the tables maintained by the network device. Send actions require support of proprietery File exchange protocol.

rndFileNameOCTETread-write
.1.3.6.1.4.1.9.6.1.101.1.3

The name of the file used internally by switch001 for transferring tables maintained by network devices, using a prorietary File exchange protocol.

rndSysIdINTEGERread-only
.1.3.6.1.4.1.9.6.1.101.1.1

Identification of an switch001 device. The device type for each integer clarifies the sysObjectID in MIB - II.

rlGroupMngDeviceAdvertisedCachingTimeINTEGERread-only
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.8

The caching time advertised by the device. If no update for this device has been received during this caching time the system will assume that the device has left the network and will therefore remove its entry from the table.

rlGroupMngDeviceDescriptionDisplayStringread-only
.1.3.6.1.4.1.9.6.1.101.1.11.4.1.4

The discovery protocol description of the device.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→