CISCOSB-UDLD-MIB
The CISCOSB-UDLD-MIB enables monitoring and management of UniDirectional Link Detection (UDLD) protocol states and error counters on Cisco Catalyst switches to detect and isolate unidirectional fiber or copper link failures.
Imported Objects
Objects
21 total| Object Name |
|---|
rlUdld MODULE-IDENTITY .1.3.6.1.4.1.9.6.1.101.218 |
rlUdldPortTable SEQUENCE OF RlUdldPortEntry .1.3.6.1.4.1.9.6.1.101.218.1 |
rlUdldPortEntry RlUdldPortEntry .1.3.6.1.4.1.9.6.1.101.218.1.1 |
rlUdldPortIfIndex InterfaceIndex (IF-MIB) .1.3.6.1.4.1.9.6.1.101.218.1.1.1 |
rlUdldPortAdminModerw UdldPortMode .1.3.6.1.4.1.9.6.1.101.218.1.1.2 |
rlUdldPortOperModero UdldPortMode .1.3.6.1.4.1.9.6.1.101.218.1.1.3 |
rlUdldPortDefaultConfigurationro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.218.1.1.4 |
rlUdldBidirectionalStatero UdldPortBidirectionalState .1.3.6.1.4.1.9.6.1.101.218.1.1.5 |
rlUdldNumberOfDetectedNeighborsro INTEGER .1.3.6.1.4.1.9.6.1.101.218.1.1.6 |
rlUdldNeighborTable SEQUENCE OF RlUdldNeighborEntry .1.3.6.1.4.1.9.6.1.101.218.2 |
rlUdldNeighborEntry RlUdldNeighborEntry .1.3.6.1.4.1.9.6.1.101.218.2.1 |
rlUdldNeighborPortIfIndex InterfaceIndex (IF-MIB) .1.3.6.1.4.1.9.6.1.101.218.2.1.1 |
rlUdldNeighborDeviceID UdldString .1.3.6.1.4.1.9.6.1.101.218.2.1.2 |
rlUdldNeighborPortID UdldString .1.3.6.1.4.1.9.6.1.101.218.2.1.3 |
rlUdldNeighborDeviceMACAddress MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.218.2.1.4 |
rlUdldNeighborDeviceNamero UdldString .1.3.6.1.4.1.9.6.1.101.218.2.1.5 |
rlUdldNeighborMessageTimero INTEGER .1.3.6.1.4.1.9.6.1.101.218.2.1.6 |
rlUdldNeighborLeftLifeTimero INTEGER .1.3.6.1.4.1.9.6.1.101.218.2.1.7 |
rlUdldNeighborCurrentStatero UdldNeighborCurrentState .1.3.6.1.4.1.9.6.1.101.218.2.1.8 |
rlUdldGlobalUDLDModerw UdldGlobalMode .1.3.6.1.4.1.9.6.1.101.218.3 |
rlUdldGlobalMessageTimerw INTEGER .1.3.6.1.4.1.9.6.1.101.218.4 |
CISCOSB-UDLD-MIB Technical Reference Overview
The CISCOSB-UDLD-MIB SNMP MIB module published by Cisco defines 21 managed OID objects, including 16 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.6.1.101.218. Key tabular structures include rlUdldNeighborTable, rlUdldPortTable.
Key OID Definitions in CISCOSB-UDLD-MIB
.1.3.6.1.4.1.9.6.1.101.218This private MIB module for UDLD (Cisco Systems UniDirectional Link Detection Protocol).
.1.3.6.1.4.1.9.6.1.101.218.2The table holds information for Udld Neighbor of ethernet ports.
.1.3.6.1.4.1.9.6.1.101.218.1The table holds information for Udld Ethernet ports.
.1.3.6.1.4.1.9.6.1.101.218.4Define global value of the interval between two sent probe messages, use the udld message time command in Global Configuration mode.
.1.3.6.1.4.1.9.6.1.101.218.3Define Global UDLD Mode (normal, aggressive, disable)
.1.3.6.1.4.1.9.6.1.101.218.1.1.5This variable identifies the port UDLD status (shutdown, idle, detection, undetermined, bidirectional).
.1.3.6.1.4.1.9.6.1.101.218.2.1.8This variable identifies the Neighbor port UDLD current status (Disabled, Enabled, Undefined, Bidirectional).
.1.3.6.1.4.1.9.6.1.101.218.2.1.2The Neighbor Device-ID TLV should contain the switch base MAC address in ACSII format.
.1.3.6.1.4.1.9.6.1.101.218.2.1.4The Neighbor mac address
.1.3.6.1.4.1.9.6.1.101.218.2.1.5The Neighbor NeighborDevice Name TLV should contain sysName in ACSII.
.1.3.6.1.4.1.9.6.1.101.218.2.1Entry in the rlUdldNeighborTable.
.1.3.6.1.4.1.9.6.1.101.218.2.1.7The remaining holdtime for Neighbor entry in cache in seconds.
.1.3.6.1.4.1.9.6.1.101.218.2.1.6The Neighbor Message Time is from Message Interval TLV. This time interval value used by a neighbor to send UDLD probes after the linkup or detection phases. Its time unit is 1 second.
.1.3.6.1.4.1.9.6.1.101.218.2.1.3The Port-ID TLV should contain the port ACSII name as it is printed in show CLI commands.
.1.3.6.1.4.1.9.6.1.101.218.2.1.1Interface Index. This variable is the key for udld port Neighbor table. uniquely identifies the udld port index.
.1.3.6.1.4.1.9.6.1.101.218.1.1.6Number Of Detected Neighbors for this port.
.1.3.6.1.4.1.9.6.1.101.218.1.1.2This variable identifies port UDLD admin configured mode (normal, aggressive, disable).
.1.3.6.1.4.1.9.6.1.101.218.1.1.4This variable indicates whether tne user configure the udld port. to present (default) or not in port configuration.
.1.3.6.1.4.1.9.6.1.101.218.1.1Entry in the rlUdldPortTable.
.1.3.6.1.4.1.9.6.1.101.218.1.1.1Interface Index. This variable is the key for udld port table. uniquely identifies the udld port information.
.1.3.6.1.4.1.9.6.1.101.218.1.1.3This variable identifies port UDLD operational mode (normal, aggressive, disable). for fiber ports it is combination of global mode and port mode
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.