The CISCOSB-PHY-MIB provides vendor-specific management access to Layer 1 physical interface attributes and diagnostic parameters for Cisco SB series hardware. It enables the monitoring of physical port status, signal integrity metrics, and low-level interface statistics required for troubleshooting hardware connectivity issues.
The MIB module describes the private MIB for testing Layer1 interfaces supported by CISCOSB's software and products.
Main OID:
rlPhy.1.3.6.1.4.1.9.6.1.101.90
13
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
13 total| Object Name |
|---|
rlPhyThe MIB module describes the private MIB for testing Layer1 interfaces supported by CISCOSB's software and products. MODULE-IDENTITY .1.3.6.1.4.1.9.6.1.101.90 |
rlPhyTest OBJECT IDENTIFIER .1.3.6.1.4.1.9.6.1.101.90.1 |
rlPhyTestSetTable SEQUENCE OF RlPhyTestSetEntry .1.3.6.1.4.1.9.6.1.101.90.1.1 |
rlPhyTestSetEntryAn entry containing objects for invoking tests on an interface. RlPhyTestSetEntry .1.3.6.1.4.1.9.6.1.101.90.1.1.1 |
rlPhyTestSetTypeA control variable used to start operator initiated interface tests.1 indicates that no test has been initiated. Only operator initiated interface tests can be set to this variable.rw RlPhyTestType .1.3.6.1.4.1.9.6.1.101.90.1.1.1.1 |
rlPhyTestGetTable SEQUENCE OF RlPhyTestGetEntry .1.3.6.1.4.1.9.6.1.101.90.1.2 |
rlPhyTestGetEntryAn entry containing results of tests on an interface. RlPhyTestGetEntry .1.3.6.1.4.1.9.6.1.101.90.1.2.1 |
rlPhyTestGetTypeA control variable used to, 1 to indicate that this test can be done on the specified port, 2 to initiate the test whenever the user wishesro RlPhyTestType .1.3.6.1.4.1.9.6.1.101.90.1.2.1.1 |
rlPhyTestGetStatusThis object contains the status of the most recently requested test for operator initiated tests or the value none(1) if no tests have been requested since the last reset. For non operator initiated tests the value is always none(1). Note that this facility provides no provision for saving the results of one test when starting another, as could be required if used by multiple managers concurrently.ro Enumeration .1.3.6.1.4.1.9.6.1.101.90.1.2.1.2 |
rlPhyTestGetResultThis object holds the test resultro INTEGER .1.3.6.1.4.1.9.6.1.101.90.1.2.1.3 |
rlPhyTestGetUnitsThe test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7).ro Enumeration .1.3.6.1.4.1.9.6.1.101.90.1.2.1.4 |
rlPhyTestGetAlarmThis object hold the Alarm for this Entry. only Test that have can have alarms use this field, other holds the Value notRelevant(1)ro Enumeration .1.3.6.1.4.1.9.6.1.101.90.1.2.1.5 |
rlPhyTestGetTimeStampThe time in string (formated DD-MMM-YYYY HH:MM:SS e.g 14-Apr-2002 10:33:31)ro DisplayString .1.3.6.1.4.1.9.6.1.101.90.1.2.1.6 |