CISCOSB-MAC-BASE-PRIO
The CISCOSB-MAC-BASE-PRIO private MIB module monitors and configures the 802.1p Class of Service (CoS) priority values associated with the MAC layer on Cisco Catalyst switches. It provides visibility into the base priority mapping used for traffic classification and queuing decisions within the switch's hardware forwarding engine.
Imported Objects
Objects
22 total| Object Name |
|---|
rlMacBasePrioThe private MIB module definition for MAC base priorities. MODULE-IDENTITY .1.3.6.1.4.1.9.6.1.101.101 |
rlMacBasePrioMibVersionIndicates the snmp support version that is supported by this device.ro INTEGER .1.3.6.1.4.1.9.6.1.101.101.1 |
rlMacBasePrioSupportindicates which features of the max base prio are supported: (bit 0 is the most significant bit) bit 0 - ForceL3Cos bit 1 - SADA_TCro OCTET STRING .1.3.6.1.4.1.9.6.1.101.101.2 |
rlMacBasePrioForceL3CosEnableThis variable controlls the activation of ForceL3Cos feature in Mac base priorityrw Enumeration .1.3.6.1.4.1.9.6.1.101.101.3 |
rlMacBasePrioForceL3CosTableA table that contains information about ranges of addresses that are used in the mac based ptiority with the ForceL3Cos feature. SEQUENCE OF RlMacBasePrioForceL3CosEntry .1.3.6.1.4.1.9.6.1.101.101.4 |
rlMacBasePrioForceL3CosEntryInformation about ranges of MAC addresses that are used in the mac based priority with the ForeL3Cos feature RlMacBasePrioForceL3CosEntry .1.3.6.1.4.1.9.6.1.101.101.4.1 |
rlMacBasePrioForceL3CosAddressThe range of address of this entry. The range may not hold MAC multicast addresses.rw MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.101.4.1.1 |
rlMacBasePrioForceL3CosMaskIndicate the mask to be logical-ANDed with the learned address before being compared to the value in the rlMacBasePrioForceL3CosAddress field.rw MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.101.4.1.2 |
rlMacBasePrioForceL3CosRowStatusThe row status variable, used according to row installation and removal conventions.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.101.4.1.3 |
rlMacBasePrioForceL3CosParamsTableThe table holds the global parameters of the L3 cos :TC, UP,DSCP. SEQUENCE OF RlMacBasePrioForceL3CosParamsEntry .1.3.6.1.4.1.9.6.1.101.101.5 |
rlMacBasePrioForceL3CosParamsEntry RlMacBasePrioForceL3CosParamsEntry .1.3.6.1.4.1.9.6.1.101.101.5.1 |
rlMacBasePrioForceL3CosParamsEntryIndexIndex of the ForceL3Cos parameters table.rw INTEGER .1.3.6.1.4.1.9.6.1.101.101.5.1.1 |
rlMacBasePrioForceL3CosParamsEntryTCThe value of the globla TCrw INTEGER .1.3.6.1.4.1.9.6.1.101.101.5.1.2 |
rlMacBasePrioForceL3CosParamsEntryUPThe value of the globla UPrw INTEGER .1.3.6.1.4.1.9.6.1.101.101.5.1.3 |
rlMacBasePrioForceL3CosParamsEntryDSCPThe value of the globla DSCPrw INTEGER .1.3.6.1.4.1.9.6.1.101.101.5.1.4 |
rlMacBasePrioSADATCEnableThis variable controlls the activation of SA/DA priority feature in Mac base priorityrw Enumeration .1.3.6.1.4.1.9.6.1.101.101.6 |
rlMacBasePrioSADATCTableA table that contains information about ranges of addresses that are used in the mac based ptiority with the ForceL3Cos feature. SEQUENCE OF RlMacBasePrioSADATCEntry .1.3.6.1.4.1.9.6.1.101.101.7 |
rlMacBasePrioSADATCEntryInformation about ranges of MAC addresses that are used in the mac based priority with the ForeL3Cos feature RlMacBasePrioSADATCEntry .1.3.6.1.4.1.9.6.1.101.101.7.1 |
rlMacBasePrioSADATCAddressThe range of address of this entry. The range may not hold MAC multicast addresses.rw MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.101.7.1.1 |
rlMacBasePrioSADATCMaskIndicate the mask to be logical-ANDed with the learned address before being compared to the value in the rlMacBasePrioSADATCAddress field.rw MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.101.7.1.2 |
rlMacBasePrioSADATCPrioThe priority that will assign to all MAC addresses that are match the range of this entry.rw INTEGER .1.3.6.1.4.1.9.6.1.101.101.7.1.3 |
rlMacBasePrioSADATCRowStatusThe row status variable, used according to row installation and removal conventions.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.101.7.1.4 |
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-ENTITY-VENDORTYPE-OID-MIB maps Cisco-specific hardware component identifiers to the ENTITY-MIB's entPhysicalTable, enabling precise differentiation of physical device types such as line cards, power supplies, and fans within Cisco infrastructure. This mapping ensures that SNMP management systems can accurately correlate physical inventory entries with vendor-specific component definitions for accurate device discovery and monitoring.
The CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB provides SNMP-based monitoring and management of Cisco Unified Computing System (UCS) hardware components, including chassis, blades, fabric interconnects, and power supplies. It exposes critical operational metrics such as device status, port states, temperature readings, fan speeds, and power consumption data for infrastructure health assessment.
The CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB enables SNMP-based monitoring and management of physical and virtual network adapter interfaces, including link status, traffic counters, error statistics, and port configuration parameters, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers.
The CISCO-UNIFIED-COMPUTING-TC-MIB module defines standard textual conventions and data type definitions required for monitoring Cisco Unified Computing System (UCS) hardware components, including server blades, fabric interconnects, and chassis resources. These definitions enable consistent interpretation of specific UCS metrics such as power supply status, fan speeds, thermal readings, and port utilization across SNMP management applications.
The CISCO-UNIFIED-COMPUTING-FABRIC-MIB enables SNMP-based monitoring and management of the Cisco UCS Fabric Interconnects and associated fabric switching infrastructure, exposing metrics for port states, link utilization, error counters, and fabric topology status. It facilitates granular visibility into the physical and logical fabric layers, including uplink/downlink interfaces, VLAN configurations, and fabric failover conditions within the unified computing environment.
The STARENT-MIB module provides SNMP management and monitoring capabilities for Cisco ASR 5000 and ASR 5500 multimedia core platforms, specifically exposing metrics related to 2G/3G/4G and WiFi subscriber sessions, inline service states, and carrier-class high-availability status.