Home/Catalog/CISCOSB-BANNER-MIB

CISCOSB-BANNER-MIB

AI MIB Summary

The CISCOSB-BANNER-MIB manages dynamic banner message configuration on Cisco switching devices, enabling the definition of authentication prompts that support variable substitution (e.g., hostname, domain) and formatting attributes (bold, inverse, blink) scoped to specific connection types such as Telnet, SSH, or Console.

The private MIB module definition for Banner displays messages in Cisco switching devices. Banner allows users to configure display messages which are displayed on various authentication events. Banner Messages can hold dynamic data such as $(hostname) or $(domain) etc, and display instructions such as: bold, inverse, or blink. Banner Messages can be displayed or hidden with respect to the connection type: via Telnet, SSH or the Console.
Main OID:
rlBanner.1.3.6.1.4.1.9.6.1.101.133
12
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

12 total
Object Name
rlBanner
MODULE-IDENTITY
.1.3.6.1.4.1.9.6.1.101.133
rlBannerMessageTable
SEQUENCE OF RlBannerMessageEntry
.1.3.6.1.4.1.9.6.1.101.133.1
rlBannerMessageEntry
RlBannerMessageEntry
.1.3.6.1.4.1.9.6.1.101.133.1.1
rlBannerMessageType
BannerMessageType
.1.3.6.1.4.1.9.6.1.101.133.1.1.1
rlBannerMessageIndex
INTEGER
.1.3.6.1.4.1.9.6.1.101.133.1.1.2
rlBannerMessageTextrw
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.6.1.101.133.1.1.3
rlBannerManageTable
SEQUENCE OF RlBannerManageEntry
.1.3.6.1.4.1.9.6.1.101.133.2
rlBannerManageEntry
RlBannerManageEntry
.1.3.6.1.4.1.9.6.1.101.133.2.1
rlBannerManageSSHrw
EnabledStatus (P-BRIDGE-MIB)
.1.3.6.1.4.1.9.6.1.101.133.2.1.1
rlBannerManageTelnetrw
EnabledStatus (P-BRIDGE-MIB)
.1.3.6.1.4.1.9.6.1.101.133.2.1.2
rlBannerManageConsolerw
EnabledStatus (P-BRIDGE-MIB)
.1.3.6.1.4.1.9.6.1.101.133.2.1.3
rlBannerMessageClearrw
BannerMessageType
.1.3.6.1.4.1.9.6.1.101.133.3

CISCOSB-BANNER-MIB Technical Reference Overview

The CISCOSB-BANNER-MIB SNMP MIB module published by Cisco defines 12 managed OID objects, including 7 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.6.1.101.133. Key tabular structures include rlBannerManageTable, rlBannerMessageTable.

Key OID Definitions in CISCOSB-BANNER-MIB

rlBannerMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.6.1.101.133

The private MIB module definition for Banner displays messages in Cisco switching devices. Banner allows users to configure display messages which are displayed on various authentication events. Banner Messages can hold dynamic data such as $(hostname) or $(domain) etc, and display instructions such as: bold, inverse, or blink. Banner Messages can be displayed or hidden with respect to the connection type: via Telnet, SSH or the Console.

rlBannerManageTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.6.1.101.133.2

The table listing specifying for each connection type which Banner should, or should not be displayed.

rlBannerMessageTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.6.1.101.133.1

The table listing the Banner content.

rlBannerMessageClearBannerMessageTyperead-write
.1.3.6.1.4.1.9.6.1.101.133.3

This value, when set, clears the selected Banner type. Clearing the Banner type means that the related entry from rlBannerMessageTable is removed.

rlBannerManageConsoleEnabledStatusread-write
.1.3.6.1.4.1.9.6.1.101.133.2.1.3

This variable specifies whether the banner type specified in the key should or should not be displayed when a user accesses the device via Console.

rlBannerManageEntryRlBannerManageEntrynot-accessible
.1.3.6.1.4.1.9.6.1.101.133.2.1

An entry in the rlBannerManageTable.

rlBannerManageSSHEnabledStatusread-write
.1.3.6.1.4.1.9.6.1.101.133.2.1.1

This variable specifies whether the banner type specified in the key should or should not be displayed when a user accesses the device via SSH.

rlBannerManageTelnetEnabledStatusread-write
.1.3.6.1.4.1.9.6.1.101.133.2.1.2

This variable specifies whether the banner type specified in the key should or should not be displayed when a user accesses the device via Telnet.

rlBannerMessageEntryRlBannerMessageEntrynot-accessible
.1.3.6.1.4.1.9.6.1.101.133.1.1

An entry in the rlBannerMessageTable.

rlBannerMessageIndexINTEGERnot-accessible
.1.3.6.1.4.1.9.6.1.101.133.1.1.2

This variable identifies a Banner string section in the Banner content. The Banner content is limited to 2000 characters. Content is divided into 13 indexed sections. Each section contains 160 octets, except the last used section which can contain less than 160 octets. Once a section of the Banner string contains 160 octets of data, the user can write to the next index. Overwriting is not supported. To delete all Banner content, use the rlBannerMessageClear MIB.

rlBannerMessageTextSnmpAdminStringread-write
.1.3.6.1.4.1.9.6.1.101.133.1.1.3

This variable identifies the MIB which holds a section of the Banner content in the table.

rlBannerMessageTypeBannerMessageTypenot-accessible
.1.3.6.1.4.1.9.6.1.101.133.1.1.1

This variable identifies the Banner type. There are three types: MOTD, Login and Exec.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→