Home/Catalog/CISCO-VSIMASTER-MIB

CISCO-VSIMASTER-MIB

AI MIB Summary

The CISCO-VSIMASTER-MIB provides management objects for the master entity of the Virtual Switch Interface (VSI) protocol on Cisco ATM switches, enabling monitoring of VSI control states, session parameters, and master-slave synchronization metrics for ATM virtual circuit management.

This MIB module contains objects related to the master side of the Virtual Switch Interface protocol used for control of ATM switches.
Main OID:
ciscoVsiMasterMIB.1.3.6.1.4.1.9.9.162
90
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

90 total
Object Name
ciscoVsiMasterMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.162
ciscoVsiMasterObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162.1
vsiMasterControllerTable
SEQUENCE OF VsiMasterControllerEntry
.1.3.6.1.4.1.9.9.162.1.1
vsiMasterControllerEntry
VsiMasterControllerEntry
.1.3.6.1.4.1.9.9.162.1.1.1
vsiControllerIndexro
VsiControllerIndex
.1.3.6.1.4.1.9.9.162.1.1.1.1
vsiControllerIdro
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.2
vsiCrossConnectsro
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.3
vsiControllerTypero
Enumeration
.1.3.6.1.4.1.9.9.162.1.1.1.4
vsiBaseVersionSupportedro
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.5
vsiTopVersionSupportedro
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.6
vsiVersionInUsero
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.7
vsiSpecifiedVersionrw
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.8
vsiControlInterfacero
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.9.9.162.1.1.1.9
vsiLogicalControlInterfacero
VsiLogicalIfIndex
.1.3.6.1.4.1.9.9.162.1.1.1.10
vsiControlIfIpAddressro
IpAddress
.1.3.6.1.4.1.9.9.162.1.1.1.11
vsiAvailableChnlWarnThresholdrw
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.12
vsiAvailableChnlAlarmThresholdrw
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.13
vsiAvailableChnlThresholdStatusro
Enumeration
.1.3.6.1.4.1.9.9.162.1.1.1.14
vsiSessionTable
SEQUENCE OF VsiSessionEntry
.1.3.6.1.4.1.9.9.162.1.2
vsiSessionEntry
VsiSessionEntry
.1.3.6.1.4.1.9.9.162.1.2.1
vsiSessionControllerIndex
VsiControllerIndex
.1.3.6.1.4.1.9.9.162.1.2.1.1
vsiSessionIndex
VsiSessionIndex
.1.3.6.1.4.1.9.9.162.1.2.1.2
vsiSessionVpiro
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.3
vsiSessionVciro
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.4
vsiSessionSwitchIdro
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.5
vsiSessionSwitchNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.162.1.2.1.6
vsiSessionSlaveIdro
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.7
vsiSessionStatero
Enumeration
.1.3.6.1.4.1.9.9.162.1.2.1.8
vsiSessionWindowSizero
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.9
vsiSessionCmdsPendingro
Gauge32
.1.3.6.1.4.1.9.9.162.1.2.1.10
vsiSessionActiveIdro
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.11
vsiSessionPowerupIdro
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.12
vsiLogicalIfTable
SEQUENCE OF VsiLogicalIfEntry
.1.3.6.1.4.1.9.9.162.1.3
vsiLogicalIfEntry
VsiLogicalIfEntry
.1.3.6.1.4.1.9.9.162.1.3.1
vsiLogicalIfControllerIndexro
VsiControllerIndex
.1.3.6.1.4.1.9.9.162.1.3.1.1
vsiLogicalIfIndexro
VsiLogicalIfIndex
.1.3.6.1.4.1.9.9.162.1.3.1.2
vsiLogicalIfNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.162.1.3.1.3
vsiLogicalIfOperStatero
Enumeration
.1.3.6.1.4.1.9.9.162.1.3.1.4
vsiLogicalIfAdminStatero
Enumeration
.1.3.6.1.4.1.9.9.162.1.3.1.5
vsiLogicalIfRxCellsro
Counter32
.1.3.6.1.4.1.9.9.162.1.3.1.6
vsiLogicalIfTxCellsro
Counter32
.1.3.6.1.4.1.9.9.162.1.3.1.7
vsiLogicalIfRxCellsDiscardedro
Counter32
.1.3.6.1.4.1.9.9.162.1.3.1.8
vsiLogicalIfTxCellsDiscardedro
Counter32
.1.3.6.1.4.1.9.9.162.1.3.1.9
vsiLogicalIfRxHeaderErrorsro
Counter32
.1.3.6.1.4.1.9.9.162.1.3.1.10
vsiLogicalIfRxInvalidAddrsro
Counter32
.1.3.6.1.4.1.9.9.162.1.3.1.11
vsiLogicalIfEndPointsInUsero
Gauge32
.1.3.6.1.4.1.9.9.162.1.3.1.12
vsiLogicalIfAvailIngressChnlsro
Gauge32
.1.3.6.1.4.1.9.9.162.1.3.1.13
vsiLogicalIfAvailEgressChnlsro
Gauge32
.1.3.6.1.4.1.9.9.162.1.3.1.14
vsiLogicalIfAvailIngressCellRatero
Gauge32
.1.3.6.1.4.1.9.9.162.1.3.1.15
vsiLogicalIfAvailEgressCellRatero
Gauge32
.1.3.6.1.4.1.9.9.162.1.3.1.16
vsiLogicalIfVcMergeSupportedro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.162.1.3.1.17
vsiLogicalIfMulticastSupportedro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.162.1.3.1.18
vsiLogicalIfVpiTranslatedro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.162.1.3.1.19
vsiLogicalIfStrictSigRangero
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.162.1.3.1.20
vsiLogicalIfMaxIngressCellRatero
Integer32
.1.3.6.1.4.1.9.9.162.1.3.1.21
vsiLogicalIfMaxEgressCellRatero
Integer32
.1.3.6.1.4.1.9.9.162.1.3.1.22
vsiLogicalIfMinVpiro
INTEGER
.1.3.6.1.4.1.9.9.162.1.3.1.23
vsiLogicalIfMaxVpiro
INTEGER
.1.3.6.1.4.1.9.9.162.1.3.1.24
vsiLogicalIfMinVciro
INTEGER
.1.3.6.1.4.1.9.9.162.1.3.1.25
vsiLogicalIfMaxVciro
INTEGER
.1.3.6.1.4.1.9.9.162.1.3.1.26
vsiLogicalControlIfIndexro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.9.9.162.1.3.1.27
vsiLogicalIfSessionIndexro
VsiSessionIndex
.1.3.6.1.4.1.9.9.162.1.3.1.28
vsiXCTable
SEQUENCE OF VsiXCEntry
.1.3.6.1.4.1.9.9.162.1.4
vsiXCEntry
VsiXCEntry
.1.3.6.1.4.1.9.9.162.1.4.1
vsiXCControllerIndexro
VsiControllerIndex
.1.3.6.1.4.1.9.9.162.1.4.1.1
vsiXCLogicalIfLowro
VsiLogicalIfIndex
.1.3.6.1.4.1.9.9.162.1.4.1.2
vsiXCLogicalIfHiro
VsiLogicalIfIndex
.1.3.6.1.4.1.9.9.162.1.4.1.3
vsiXCIndexro
VsiXCIndex
.1.3.6.1.4.1.9.9.162.1.4.1.4
vsiXCStatero
Enumeration
.1.3.6.1.4.1.9.9.162.1.4.1.5
vsiXCVpiLowro
Integer32
.1.3.6.1.4.1.9.9.162.1.4.1.6
vsiXCVciLowro
Integer32
.1.3.6.1.4.1.9.9.162.1.4.1.7
vsiXCVpiHiro
Integer32
.1.3.6.1.4.1.9.9.162.1.4.1.8
vsiXCVciHiro
Integer32
.1.3.6.1.4.1.9.9.162.1.4.1.9
vsiControllerTrapEnablerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.162.1.5
vsiSessionTrapEnablerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.162.1.6
vsiLogicalIfTrapEnablerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.162.1.7
vsiXCTrapEnablerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.162.1.8
vsiVSITrapEnablerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.162.1.9
ciscoVsiMasterNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162.2
vsiControllerAdded
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.162.2.1
vsiControllerDeleted
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.162.2.2
vsiSessionUp
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.162.2.3
vsiSessionDown
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.162.2.4
vsiLogicalIfUp
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.162.2.5
vsiLogicalIfDown
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.162.2.6
vsiXCFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.162.2.7
vsiLcnExhaustionNotice
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.162.2.8
ciscoVsiMasterConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162.3
ciscoVsiMasterGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162.3.1
ciscoVsiMasterCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162.3.2

CISCO-VSIMASTER-MIB Technical Reference Overview

The CISCO-VSIMASTER-MIB SNMP MIB module published by Cisco defines 90 managed OID objects, including 68 scalar/column metrics, 4 SNMP tables, and 8 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.162. Key tabular structures include vsiMasterControllerTable, vsiSessionTable, vsiLogicalIfTable, vsiXCTable. Monitored SNMP traps/notifications include vsiControllerAdded, vsiControllerDeleted, vsiSessionUp, vsiSessionDown, vsiLogicalIfUp, vsiLogicalIfDown.

Key OID Definitions in CISCO-VSIMASTER-MIB

ciscoVsiMasterMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.162

This MIB module contains objects related to the master side of the Virtual Switch Interface protocol used for control of ATM switches.

vsiMasterControllerTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.162.1.1

A table containing a set of VSI controllers. Each controller represents an instance of the VSI Master control protocol. A controller communicates with a set of VSI Slaves across a control interface. Running the VSI protocol, the controller supports a network control application. Through VSI, such an application can control the Virtual Circuit cross-connect table inside the ATM switch, perform monitoring and statistics collection of interfaces and virtual circuits on the switch, and discover configuration information from within the switch.

vsiSessionTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.162.1.2

A table containing VSI master-slave session status information. Each VSI controller manages a set of VSI slaves, via a protocol instance called a Session. VSI slaves are entities that reside on the controlled ATM switch. Their number and characteristics are discovered by the VSI controller via the VSI protocol. This table has an entry for each slave so discovered.

vsiLogicalIfTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.162.1.3

A table containing information about logical interfaces on the slave switch controlled via VSI. Logical interfaces are an abstraction of exposed, external ATM interfaces that are available for connections. When two external interfaces, represented by two logical interfaces, are paired, they provide physical paths through the switch. These physical pathways support cross-connects.

vsiXCTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.162.1.4

A table containing information about cross-connects on the slave switch controlled via VSI. cross-connects represent virtual links across two interfaces. The participating interfaces that support these links are represented in this MIB by the vsiLogicalIfTable entries.

vsiControllerAddedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.162.2.1

This notification is generated when a vsiMasterControllerEntry is added to the vsiMasterControllerTable. The vsiControllerType object identifies the type and instance of the entry that was added. The agent will not generate this notification if the vsiControllerTrapEnable object is equal to 'false'.

vsiControllerDeletedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.162.2.2

This notification is generated when a vsiMasterControllerEntry is deleted from the vsiMasterControllerTable. The vsiControllerType object identifies the type and instance of the entry that was deleted. The agent will not generate this notification if the vsiControllerTrapEnable object is equal to 'false'.

vsiSessionUpNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.162.2.3

This notification is generated when the vsiSessionState object transitions to the established(8) state. The vsiSessionState object identifies the state and instance of the session, after the session has made the transition that caused the notification to be generated. The agent will not generate this notification if the vsiSessionTrapEnable object is equal to 'false'.

vsiSessionDownNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.162.2.4

This notification is generated when the vsiSessionState object transitions from any of unknown(1), configuring(2), or established(8) state to shutdownStarting(9) states. This notification is also generated when the vsiSessionState transitions from configuring(2) or established(8) state to the unknown(1) state. The vsiSessionState object identifies the state and instance of the session, after the session has made the transition that caused the notification to be generated. The agent will not generate this notification if the vsiSessionTrapEnable object is equal to 'false'.

vsiLogicalIfUpNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.162.2.5

This notification is generated when the vsiLogicalIfOperState object transitions to the active(2) state. The vsiLogicalIfOperState object identifies the state and instance of the logical interface, after the logical interface has made the transition that caused the notification to be generated. The agent will not generate this notification if the vsiLogicalIfTrapEnable object is equal to 'false'.

vsiLogicalIfDownNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.162.2.6

This notification is generated when the vsiLogicalIfOperState object transitions from the active(2) state to either the failedExternal(3) or failedInternal(4) state. The vsiLogicalIfOperState object identifies the state and instance of the logical interface, after the logical interface has made the transition that caused the notification to be generated. The agent will not generate this notification if the vsiLogicalIfTrapEnable object is equal to 'false'.

vsiXCFailedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.162.2.7

This notification is generated when an attempt to create a cross-connect fails. Failure means the slave has answered a connect command with a nak, reject, or error response. The vsiXCControllerIndex object identifies the VsiControllerIndex of the VSI controller through which the cross-connect was attempted. The vsiXCLogicalIfLow object provides the lower valued VsiLogicalIfIndex of the logical interface on which the cross-connect was attempted. The vsiXCLogicalIfHi object provides the higher valued VsiLogicalIfIndex of the logical interface on which the cross-connect was attempted. The agent will not generate this notification if the vsiXCTrapEnable object is equal to 'false'.

vsiLcnExhaustionNoticeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.162.2.8

As cross-connects on logical interfaces are instantiated or released, and available channel counts are respectively diminished or augmented, there is a potential for the available channel counts to cross a threshold. The threshold value may be crossed in the positive direction as the available channel count is rising, or in a negative direction as the available channel count is falling. The threshold values are described as the vsiAvailableChnlWarnThreshold and the vsiAvailableChnlAlarmThreshold objects. The vsiControllerIndex identifies the controller domain in which the threshold event took place. The vsiAvailableChnlThresholdStatus indicates the particular kind of threshold crossing that occurred. When comparison with vsiAvailableChnlWarnThreshold indicates a negative crossing, this notification, with vsiAvailableChnlThresholdStatus:warning(1) is emitted. When comparison with vsiAvailableChnlAlarmThreshold indicates a negative threshold violation, this notification, with vsiAvailableChnlThresholdStatus:alarm(2) is emitted. When comparison with vsiAvailableChnlWarnThreshold indicates a positive threshold crossing, and if the preceeding vsiLcnExhaustionNotice had been sent with the vsiAvailableChnlThresholdStatus:alarm(2) parameter, this notification, with vsiAvailableChnlThresholdStatus:recovery(3) is emitted. The agent will not generate this notification if the vsiXCTrapEnable is equal to 'false'.

vsiControllerTrapEnableTruthValueread-write
.1.3.6.1.4.1.9.9.162.1.5

If this object is true, both vsiControllerAdded and vsiControllerDeleted notifications are enabled.

vsiSessionTrapEnableTruthValueread-write
.1.3.6.1.4.1.9.9.162.1.6

If this object is true, both vsiSessionUp and vsiSessionDown notifications are enabled.

vsiLogicalIfTrapEnableTruthValueread-write
.1.3.6.1.4.1.9.9.162.1.7

If this object is true, both vsiLogicalIfUp and vsiLogicalIfDown notifications are enabled.

vsiXCTrapEnableTruthValueread-write
.1.3.6.1.4.1.9.9.162.1.8

If this object is true, both vsiXCFailed and vsiLcnExhaustionNotice notifications are enabled.

vsiVSITrapEnableTruthValueread-write
.1.3.6.1.4.1.9.9.162.1.9

If this object is true, all of vsiControllerTrapEnable, vsiSessionTrapEnable, vsiLogicalIfTrapEnable, and vsiXCTrapEnable are also set to true. This allows for enabling and disabling all notifications as a group.

vsiMasterControllerEntryVsiMasterControllerEntrynot-accessible
.1.3.6.1.4.1.9.9.162.1.1.1

An entry containing management information applicable to a controller which uses the VSI protocol. Controller entries represent internally generated control structures. Therefore each row is created by the agent in response to the learning of a controller's instantiation. Instantiation of a controller is performed by the VSI Master protocol implementation under management via this MIB. These structures, once instantiated, are never deleted. Each controller manages a set of VSI slaves, via a protocol instance called a Session.

vsiControllerIndexVsiControllerIndexread-only
.1.3.6.1.4.1.9.9.162.1.1.1.1

A unique value per VSI controller, greater than 0. This object gets its value from the vsiControllerId, and is used for row selection within the vsiMasterControllerTable.

vsiControllerIdInteger32read-only
.1.3.6.1.4.1.9.9.162.1.1.1.2

The controller identifier for the VSI controller. Values are arbitrarily assigned by the VSI protocol implementation being managed via this MIB, with local significance only. These values appear in the header of all VSI protocol messages.

vsiCrossConnectsInteger32read-only
.1.3.6.1.4.1.9.9.162.1.1.1.3

This object contains a value equal to the number of cross-connects being controlled via VSI protocol via this controller.

vsiControllerTypeINTEGERread-only
.1.3.6.1.4.1.9.9.162.1.1.1.4

A VSI controller represents an instance of a service layer accessible to a network control application. This object serves to identify the type of the network control application currently being supported by this controller. other(1): the type is unspecified. mpls(2): indicates that the client is a Label Switch Controller performing Multi Protocol Label Switching. pnni(3): indicates that the client is an instance of the ATM Private Network to Network Interface. par(4): indicates that the client is an instance of ATM Portable Autoroute.

vsiBaseVersionSupportedInteger32read-only
.1.3.6.1.4.1.9.9.162.1.1.1.5

A VSI Master protocol instance defines internally a set of versions of the protocol that it will support. These versions are numbered, by default, starting from 1. This object makes available the lowest numbered version that the VSI Master protocol supports. This object is related to the other vsiMasterControllerEntry objects, vsiTopVersionSupported and vsiVersionInUse.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→