CISCO-VSI-MASTER-MIB

AI MIB Summary

The CISCO-VSI-MASTER-MIB monitors and manages the master-side control plane state of Cisco ATM switches operating the Virtual Switch Interface (VSI) protocol. It exposes specific metrics for VSI session establishment, maintenance, and termination to facilitate the administration of ATM switching fabric coordination.

This MIB module contains objects related to the master side of the the Virtual Switch Interface protocol used for control of ATM switches.
76
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

76 total
Object Name
ciscoVsiMasterMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162
SNMPv2-SMI-v1
Unknown
.1.3.6.1.4.1.9.9.162
ciscoVsiMasterObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162.1
vsiMasterControllerTable
SEQUENCE OF VsiMasterControllerEntry
.1.3.6.1.4.1.9.9.162.1.1
vsiMasterControllerEntry
VsiMasterControllerEntry
.1.3.6.1.4.1.9.9.162.1.1.1
vsiControllerIndex
VsiControllerIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.1
vsiControllerIdro
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.2
vsiCrossConnectsro
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.3
vsiControllerTypero
Enumeration
.1.3.6.1.4.1.9.9.162.1.1.1.4
vsiBaseVersionSupportedro
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.5
vsiTopVersionSupportedro
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.6
vsiVersionInUsero
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.7
vsiSpecifiedVersionrw
Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.8
vsiControlInterfacero
InterfaceIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.9
vsiLogicalControlInterfacero
VsiLogicalIfIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.1.1.10
vsiSessionTable
SEQUENCE OF VsiSessionEntry
.1.3.6.1.4.1.9.9.162.1.2
vsiSessionEntry
VsiSessionEntry
.1.3.6.1.4.1.9.9.162.1.2.1
vsiSessionControllerIndex
VsiControllerIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.1
vsiSessionIndex
VsiSessionIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.2
vsiSessionVpiro
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.3
vsiSessionVciro
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.4
vsiSessionSwitchIdro
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.5
vsiSessionSwitchNamero
SnmpAdminString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.9.9.162.1.2.1.6
vsiSessionSlaveIdro
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.7
vsiSessionStatero
Enumeration
.1.3.6.1.4.1.9.9.162.1.2.1.8
vsiSessionWindowSizero
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.9
vsiSessionCmdsPendingro
Gauge32
.1.3.6.1.4.1.9.9.162.1.2.1.10
vsiSessionActiveIdro
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.11
vsiSessionPowerupIdro
Integer32
.1.3.6.1.4.1.9.9.162.1.2.1.12
vsiLogicalIfTable
SEQUENCE OF VsiLogicalIfEntry
.1.3.6.1.4.1.9.9.162.1.3
vsiLogicalIfEntry
VsiLogicalIfEntry
.1.3.6.1.4.1.9.9.162.1.3.1
vsiLogicalIfControllerIndex
VsiControllerIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.3.1.1
vsiLogicalIfIndex
VsiLogicalIfIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.3.1.2
vsiLogicalIfNamero
SnmpAdminString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.9.9.162.1.3.1.3
vsiLogicalIfOperStatero
Enumeration
.1.3.6.1.4.1.9.9.162.1.3.1.4
vsiLogicalIfAdminStatero
Enumeration
.1.3.6.1.4.1.9.9.162.1.3.1.5
vsiLogicalIfRxCellsro
Counter32
.1.3.6.1.4.1.9.9.162.1.3.1.6
vsiLogicalIfTxCellsro
Counter32
.1.3.6.1.4.1.9.9.162.1.3.1.7
vsiLogicalIfRxCellsDiscardedro
Counter32
.1.3.6.1.4.1.9.9.162.1.3.1.8
vsiLogicalIfTxCellsDiscardedro
Counter32
.1.3.6.1.4.1.9.9.162.1.3.1.9
vsiLogicalIfRxHeaderErrorsro
Counter32
.1.3.6.1.4.1.9.9.162.1.3.1.10
vsiLogicalIfRxInvalidAddrsro
Counter32
.1.3.6.1.4.1.9.9.162.1.3.1.11
vsiLogicalIfEndPointsInUsero
Gauge32
.1.3.6.1.4.1.9.9.162.1.3.1.12
vsiLogicalIfAvailIngressChnlsro
Gauge32
.1.3.6.1.4.1.9.9.162.1.3.1.13
vsiLogicalIfAvailEgressChnlsro
Gauge32
.1.3.6.1.4.1.9.9.162.1.3.1.14
vsiLogicalIfAvailIngressCellRatero
Gauge32
.1.3.6.1.4.1.9.9.162.1.3.1.15
vsiLogicalIfAvailEgressCellRatero
Gauge32
.1.3.6.1.4.1.9.9.162.1.3.1.16
vsiLogicalIfVcMergeSupportedro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.9.9.162.1.3.1.17
vsiLogicalIfMulticastSupportedro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.9.9.162.1.3.1.18
vsiLogicalIfVpiTranslatedro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.9.9.162.1.3.1.19
vsiLogicalIfStrictSigRangero
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.9.9.162.1.3.1.20
vsiLogicalIfMaxIngressCellRatero
Integer32
.1.3.6.1.4.1.9.9.162.1.3.1.21
vsiLogicalIfMaxEgressCellRatero
Integer32
.1.3.6.1.4.1.9.9.162.1.3.1.22
vsiLogicalIfMinVpiro
INTEGER
.1.3.6.1.4.1.9.9.162.1.3.1.23
vsiLogicalIfMaxVpiro
INTEGER
.1.3.6.1.4.1.9.9.162.1.3.1.24
vsiLogicalIfMinVciro
INTEGER
.1.3.6.1.4.1.9.9.162.1.3.1.25
vsiLogicalIfMaxVciro
INTEGER
.1.3.6.1.4.1.9.9.162.1.3.1.26
vsiLogicalControlIfIndexro
InterfaceIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.3.1.27
vsiLogicalIfSessionIndexro
VsiSessionIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.3.1.28
vsiXCTable
SEQUENCE OF VsiXCEntry
.1.3.6.1.4.1.9.9.162.1.4
vsiXCEntry
VsiXCEntry
.1.3.6.1.4.1.9.9.162.1.4.1
vsiXCControllerIndex
VsiControllerIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.4.1.1
vsiXCLogicalIfLow
VsiLogicalIfIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.4.1.2
vsiXCLogicalIfHi
VsiLogicalIfIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.4.1.3
vsiXCIndex
VsiXCIndex -- Rsyntax Integer32
.1.3.6.1.4.1.9.9.162.1.4.1.4
vsiXCStatero
Enumeration
.1.3.6.1.4.1.9.9.162.1.4.1.5
vsiXCVpiLowro
Integer32
.1.3.6.1.4.1.9.9.162.1.4.1.6
vsiXCVciLowro
Integer32
.1.3.6.1.4.1.9.9.162.1.4.1.7
vsiXCVpiHiro
Integer32
.1.3.6.1.4.1.9.9.162.1.4.1.8
vsiXCVciHiro
Integer32
.1.3.6.1.4.1.9.9.162.1.4.1.9
ciscoVsiMasterNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162.2
ciscoVsiMasterConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162.3
ciscoVsiMasterGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162.3.1
ciscoVsiMasterGeneralGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162.3.1.1
ciscoVsiMasterCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162.3.2
ciscoVsiMasterModuleCompliance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.162.3.2.1

CISCO-VSI-MASTER-MIB Technical Reference Overview

The CISCO-VSI-MASTER-MIB SNMP MIB module published by Cisco defines 76 managed OID objects, including 60 scalar/column metrics, 4 SNMP tables, and 0 trap/notification events. Key tabular structures include vsiMasterControllerTable, vsiSessionTable, vsiLogicalIfTable, vsiXCTable.

Key OID Definitions in CISCO-VSI-MASTER-MIB

vsiMasterControllerTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.162.1.1

A table containing a set of VSI controllers. Each controller represents an instance of the VSI Master control protocol. A controller communicates with a set of VSI Slaves across a control interface. Running the VSI protocol, the controller supports a network control application. Through VSI, such an application can control the Virtual Circuit cross-connect table inside the ATM switch, perform monitoring and statistics collection of interfaces and virtual circuits on the switch, and discover configuration information from within the switch.

vsiSessionTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.162.1.2

A table containing VSI master-slave session status information. Each VSI controller manages a set of VSI slaves, via a protocol instance called a Session. VSI slaves are entities that reside on the controlled ATM switch. Their number and characteristics are discovered by the VSI controller via the VSI protocol. This table has an entry for each slave so discovered.

vsiLogicalIfTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.162.1.3

A table containing information about logical interfaces on the slave switch controlled via VSI. Logical interfaces are an abstraction of exposed, external ATM interfaces that are available for connections. When two external interfaces, represented by two logical interfaces, are paired, they provide physical paths through the switch. These physical pathways support cross-connects.

vsiXCTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.162.1.4

A table containing information about crossconnects on the slave switch controlled via VSI. Cross connects represent virtual links across two interfaces. The participating interfaces that support these links are represented in this MIB by the vsiLogicalIfTable entries.

vsiMasterControllerEntryVsiMasterControllerEntrynot-accessible
.1.3.6.1.4.1.9.9.162.1.1.1

An entry containing management information applicable to a controller which uses the VSI protocol. Controller entries represent internally generated control structures. Therefore each row is created by the agent in response to the learning of a controller's instantiation. Instantiation of a controller is performed by the VSI Master protocol implementation under management via this MIB. These structures, once instantiated, are never deleted. Each controller manages a set of VSI slaves, via a protocol instance called a Session.

vsiControllerIndexVsiControllerIndexnot-accessible
.1.3.6.1.4.1.9.9.162.1.1.1.1

A unique value per VSI controller, greater than 0. This object gets its value from the vsiControllerId, and is used for row selection within the vsiMasterControllerTable.

vsiControllerIdInteger32(0..255)read-only
.1.3.6.1.4.1.9.9.162.1.1.1.2

The controller identifier for the VSI controller. Values are arbitrarily assigned by the VSI protocol implementation being managed via this MIB, with local significance only. These values appear in the header of all VSI protocol messages.

vsiCrossConnectsInteger32(0..2147483647)read-only
.1.3.6.1.4.1.9.9.162.1.1.1.3

This object contains a value equal to the number of cross-connects being controlled via VSI protocol via this controller.

vsiControllerTypeINTEGERread-only
.1.3.6.1.4.1.9.9.162.1.1.1.4

A VSI controller represents an instance of a service layer accessible to a network control application. This object serves to identify the type of the network control application currently being supported by this controller. other(1): the type is unspecified. mpls(2): indicates that the client is a Label Switch Controller performing Multi Protocol Label Switching. pnni(3): indicates that the client is an instance of the ATM Private Network to Network Interface. par(4): indicates that the client is an instance of ATM Portable Autoroute.

vsiBaseVersionSupportedInteger32(1..255)read-only
.1.3.6.1.4.1.9.9.162.1.1.1.5

A VSI Master protocol instance defines internally a set of versions of the protocol that it will support. These versions are numbered, by default, starting from 1. This object makes available the lowest numbered version that the VSI Master protocol supports. This object is related to the other vsiMasterControllerEntry objects, vsiTopVersionSupported and vsiVersionInUse.

vsiTopVersionSupportedInteger32(1..255)read-only
.1.3.6.1.4.1.9.9.162.1.1.1.6

A VSI Master protocol instance defines internally a set of versions of the protocol that it will support. These versions are numbered, by default, starting from 1. This object makes available the highest numbered version that the VSI Master protocol supports. This object is related to the other vsiMasterControllerEntry objects, vsiBaseVersionSupported and vsiVersionInUse.

vsiVersionInUseInteger32(1..255)read-only
.1.3.6.1.4.1.9.9.162.1.1.1.7

The number of the VSI version currently being used by this controller. Protocol selection procedures dictate that this should be the highest value of protocol version, between vsiBaseVersionSupported and vsiTopVersionSupported, that is supported by all slaves. An exception to this rule will occur when the version is constrained to a specific value indicated by the vsiSpecifiedVersion object.

vsiSpecifiedVersionInteger32(0..255)read-write
.1.3.6.1.4.1.9.9.162.1.1.1.8

When this object is written with a non-zero value, re-synchronization procedures will be initiated, if necessary, in order to constrain the master and slaves to use the indicated protocol version. When written with zero (0), the master and slaves should use the version dictated by the usual protocol version selection procedures; resynchronization procedures will be invoked, if necessary, to achieve this result.

vsiControlInterfaceInterfaceIndexread-only
.1.3.6.1.4.1.9.9.162.1.1.1.9

A VSI controller communicates with a set of VSI Slaves across a control interface. The controller is connected to the ATM switch via an ATM link called the Slave Control Link. The interface at the Master end of the link is the Master Control Port, and is described by this object; it is the ifIndex of this Master Control Port.

vsiLogicalControlInterfaceVsiLogicalIfIndexread-only
.1.3.6.1.4.1.9.9.162.1.1.1.10

This object describes the instance of a logical interface index bound to the slave end of the Slave Control Link, which is referred to in the description of vsiControlInterface.

vsiSessionEntryVsiSessionEntrynot-accessible
.1.3.6.1.4.1.9.9.162.1.2.1

A vsiSessionEntry is a set of objects that together represent the status of each instance of VSI protocol and the slave in an ATM switch to which that instance corresponds. There is one vsiSession for each slave. The number of slaves is discovered via the VSI protocol. Each slave is responsible for a subset of the total number of external interfaces on the ATM switch. Session entries refer back to their respective controllers via vsiSessionControllerIndex, and are in turn referred to by vsiLogicalIfSessionIndex in the VsiLogicalIfEntry. These entries are never deleted.

vsiSessionControllerIndexVsiControllerIndexnot-accessible
.1.3.6.1.4.1.9.9.162.1.2.1.1

The ID of the controller which controls this master-slave session. This identifies which vsiMasterControllerEntry represents the controller communicating with a slave through this Session.

vsiSessionIndexVsiSessionIndexnot-accessible
.1.3.6.1.4.1.9.9.162.1.2.1.2

A VSI controller discovers a set of slaves through VSI protocol. Each of the discovered slaves is bound to a protocol Session and each of these Sessions occupies a row in the vsiSessionTable. This object is the row selector. The value should remain constant after a VSI session is reinitialized.

vsiSessionVpiInteger32(0..4095)read-only
.1.3.6.1.4.1.9.9.162.1.2.1.3

The virtual path identifier for this VSI master-slave session. The Slave Control Link, referred to in the description of vsiLogicalControlInterface, supports an ATM control VC. This is the vpi for that link.

vsiSessionVciInteger32(0..65535)read-only
.1.3.6.1.4.1.9.9.162.1.2.1.4

The virtual channel identifier for this VSI master-slave session. The Slave Control Link, referred to in the description of vsiLogicalControlInterface, supports an ATM control VC. This is the vci for that link.

vsiSessionSwitchIdInteger32(0..255)read-only
.1.3.6.1.4.1.9.9.162.1.2.1.5

The identifier of the switch which participates in this VSI master-slave session. The switch terminates the virtual circuit identified by the vpi/vci pair referred to by vsiSessionVpi and vsiSessionVci.

vsiSessionSwitchNameSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.162.1.2.1.6

The IP hostname for the slave switch which is controlled by this session. This is an ascii string of maximum length 64 characters, learned from the ATM switch.

vsiSessionSlaveIdInteger32(0..255)read-only
.1.3.6.1.4.1.9.9.162.1.2.1.7

The identifier of the slave for this VSI master-slave session. This value is learned from the slave on the switch.

vsiSessionStateINTEGERread-only
.1.3.6.1.4.1.9.9.162.1.2.1.8

The state of the VSI session. inactive(1): communications data structures for communicating with the slave have been created, but the VSI protocol has not been started. unknown(2): slave has been queried, but its configuration data has not yet been recieved. configuring(3): configuration data has been sent to the slave, but a response has not yet been received. resyncStarting(4): a re-sync command has been sent to the slave, but a response has not yet been recieved. resyncUnderway(5): a re-sync command response has been received from the slave, but the network applications have not yet completed reasserting connections. resyncEnding(6): a command has been sent to end re-sync, but a response has not yet been received. discovery(7): a query has been sent to the slave for interface information, but a response has not yet been received. established(8): discovery has completed. shutdownStarting(9): the master has started an orderly shutdown of the slave.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→