Home/Catalog/CISCO-VIRTUAL-NIC-MIB

CISCO-VIRTUAL-NIC-MIB

AI MIB Summary

The CISCO-VIRTUAL-NIC-MIB enables monitoring and configuration of virtual Ethernet interfaces (veths) and their associated Virtual Network Interface Cards (VNICs) within Cisco's Distributed Virtual Switch (DVS) architecture. It provides operational visibility into the mapping between virtual chassis line cards (Virtual Ethernet Modules) and connected VM instances, tracking connectivity states for VM kernel ports (VMK) and management interfaces (VSWIF) independent of VM migration events.

This MIB module defines MIB objects which provide mechanisms to manage the parameters used by or related to Virtual NIC. Virtual switch extends across one or more virtualization servers which host the VM instances. Each virtualization server is represented as a line card module and is assigned to a unique slot in the virtual chassis. All the ports on the virtual switch which can be hooked up to VM VNICs or to special hypervisor ports (e.g. vmk or vswif ports) are represented as virtual ethernet interfaces. Virtual ethernet interfaces(veths) represent the switching ports on the virtual switch which provide networking connectivity to virtual packet based interfaces such as the Virtual NIC (VNIC) interfaces defined on a Virtual Machine (VM). These interfaces are configurable and provide operational information to the network administrator. The assignment of virtual ethernet interface ports to a VM does not change when the VM is migrated. Glossary: APC - Asymmetric Port Channel DVS - Distributed Virtual switch NIC - Network Interface Card NIV - Network interface virtualization PCI - Peripheral Component Interconnect VEM - Virtual Ethernet Module VNIC - Virtual Network Interface Card VSM - Virtual Supervisor Module VM - Virtual Machine VMK - Virtual Machine Kernel VMKNIC - Virtual Machine Kernel Network Interface Card VSWIF - a virtual management port on hosts running VMware ESX. UUID - Universally Unique identifier connectee - Entity connected to a system using veth. eg: Virtual machine System Diagram : ************** * VSM * ************** ' ' ' ' ' ' ' ' ******** ******** * VEM * * VEM * ******** ******** ' ' ' ' ' ' ****** ****** ****** * VM * * VM * * VM * ****** ****** ******
Main OID:
ciscoVirtualNicMIB.1.3.6.1.4.1.9.9.710
33
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

33 total
Object Name
ciscoVirtualNicMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.710
ciscoVirtualNicMIBNotifs
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.710.0
ciscoVirtualNicMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.710.1
cvnInterfaceObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.710.1.1
cvnVethIfTable
SEQUENCE OF CvnVethIfEntry
.1.3.6.1.4.1.9.9.710.1.1.1
cvnVethIfEntry
CvnVethIfEntry
.1.3.6.1.4.1.9.9.710.1.1.1.1
cvnVethInterface
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.9.9.710.1.1.1.1.1
cvnVethAdapterro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.710.1.1.1.1.2
cvnVethOwnerro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.710.1.1.1.1.3
cvnVethHostIDro
Unsigned32
.1.3.6.1.4.1.9.9.710.1.1.1.1.4
cvnVethHostAddrTypero
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.710.1.1.1.1.5
cvnVethHostAddrro
InetAddress (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.710.1.1.1.1.6
cvnVethPortProfileUsedro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.710.1.1.1.1.7
cvnVethIfProfileAliasro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.710.1.1.1.1.8
cvnVethIfAdditionalStatero
Enumeration
.1.3.6.1.4.1.9.9.710.1.1.1.1.9
cvnVethStateReasonro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.710.1.1.1.1.10
cvnPinningTable
SEQUENCE OF CvnPinningEntry
.1.3.6.1.4.1.9.9.710.1.1.2
cvnPinningEntry
CvnPinningEntry
.1.3.6.1.4.1.9.9.710.1.1.2.1
cvnPinnedSubGrpIdrw
Integer32 (-1..2147483647)
.1.3.6.1.4.1.9.9.710.1.1.2.1.1
cvnConnecteeObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.710.1.2
cvnConnecteeTable
SEQUENCE OF CvnConnecteeEntry
.1.3.6.1.4.1.9.9.710.1.2.1
cvnConnecteeEntry
CvnConnecteeEntry
.1.3.6.1.4.1.9.9.710.1.2.1.1
cvnConnecteeAttachTypero
Enumeration
.1.3.6.1.4.1.9.9.710.1.2.1.1.1
cvnDVSPortro
Unsigned32
.1.3.6.1.4.1.9.9.710.1.2.1.1.2
cvnConnecteeNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.710.1.2.1.1.3
cvnConnecteeUuidro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.710.1.2.1.1.4
cvnConnecteeTypero
Enumeration
.1.3.6.1.4.1.9.9.710.1.2.1.1.5
cvnConnecteeMacro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.710.1.2.1.1.6
cvnConnecteeDeviceNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.710.1.2.1.1.7
cvnConnecteeDeviceTypero
Enumeration
.1.3.6.1.4.1.9.9.710.1.2.1.1.8
ciscoVirtualNicMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.710.2
ciscoVirtualNicMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.710.2.1
ciscoVirtualNicMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.710.2.2

CISCO-VIRTUAL-NIC-MIB Technical Reference Overview

The CISCO-VIRTUAL-NIC-MIB SNMP MIB module published by Cisco defines 33 managed OID objects, including 19 scalar/column metrics, 3 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.710. Key tabular structures include cvnVethIfTable, cvnPinningTable, cvnConnecteeTable.

Key OID Definitions in CISCO-VIRTUAL-NIC-MIB

ciscoVirtualNicMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.710

This MIB module defines MIB objects which provide mechanisms to manage the parameters used by or related to Virtual NIC. Virtual switch extends across one or more virtualization servers which host the VM instances. Each virtualization server is represented as a line card module and is assigned to a unique slot in the virtual chassis. All the ports on the virtual switch which can be hooked up to VM VNICs or to special hypervisor ports (e.g. vmk or vswif ports) are represented as virtual ethernet interfaces. Virtual ethernet interfaces(veths) represent the switching ports on the virtual switch which provide networking connectivity to virtual packet based interfaces such as the Virtual NIC (VNIC) interfaces defined on a Virtual Machine (VM). These interfaces are configurable and provide operational information to the network administrator. The assignment of virtual ethernet interface ports to a VM does not change when the VM is migrated. Glossary: APC - Asymmetric Port Channel DVS - Distributed Virtual switch NIC - Network Interface Card NIV - Network interface virtualization PCI - Peripheral Component Interconnect VEM - Virtual Ethernet Module VNIC - Virtual Network Interface Card VSM - Virtual Supervisor Module VM - Virtual Machine VMK - Virtual Machine Kernel VMKNIC - Virtual Machine Kernel Network Interface Card VSWIF - a virtual management port on hosts running VMware ESX. UUID - Universally Unique identifier connectee - Entity connected to a system using veth. eg: Virtual machine System Diagram : ************** * VSM * ************** ' ' ' ' ' ' ' ' ******** ******** * VEM * * VEM * ******** ******** ' ' ' ' ' ' ****** ****** ****** * VM * * VM * * VM * ****** ****** ******

cvnVethIfTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.710.1.1.1

A list of virtual ethernet interfaces managed by VSM.

cvnPinningTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.710.1.1.2

A list of virtual ethernet interfaces which supports pinning functionality in VSM. Pinning is a mechanism of directing traffic to or from a interface through a particular interface in a switch. By default, system use load balancing algorithm to pick the best possible physical interface automatically. However, user may use pinning functionality to instrument the finite control on the traffic flow between virtual ethernet interfaces and actual physical interfaces in VSM. For example, user may want to configure that packets from a particular virtual ethernet interface always go out through first interface in the port channel irrespective of load balancing policy on the switch. In order to achieve this, user can pin the virtual ethernet interface to first interface of the switch.

cvnConnecteeTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.710.1.2.1

A list of connectees which are currently attached to virtual ethernet interfaces. Virtual machine connects to a physical entity using a virtual ethernet interface. In this scenario the Virtual Machine is called connectee, physical entity is called host. Whenever a Virtual Machine is connected using virtual ethernet interface we have mapping between physical and virtual interfaces. This object gives the mapping of all virtual ehternet interfaces to their corresponding physical entities.

cvnVethIfEntryCvnVethIfEntrynot-accessible
.1.3.6.1.4.1.9.9.710.1.1.1.1

An entry containing management information for a particular virtual ethernet interface. Entries are created by the system when virtual Ethernet interfaces are registered to VSM. Entries are removed when virtual Ethernet interfaces are removed from VSM.

cvnVethInterfaceInterfaceIndexnot-accessible
.1.3.6.1.4.1.9.9.710.1.1.1.1.1

The value of ifIndex for the virtual ethernet interface.

cvnVethAdapterSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.710.1.1.1.1.2

This object indicates the network adapter used by virtual ethernet interface port. This object contains the Network Adapter ID if Virtual Machine is attached to VNIC. This object contains VMK ID if the Virtual Machine is attached to VMKNIC. This object contains value of 'vswif' if the Virtual Machine is attached to VSWIF.

cvnVethOwnerSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.710.1.1.1.1.3

The name of the Virtual Machine that owns this virtual ethernet interface. When a Virtual Machine attaches to one of the port in physical server via this virtual ethernet interface, this VM will be considered as the owner of this virtual ethernet interface. When Virtual Machine moves from one host to another, its virtual ethernet interface remains unchanged.

cvnVethHostIDUnsigned32read-only
.1.3.6.1.4.1.9.9.710.1.1.1.1.4

A unique identifier, assigned by the system, of the registered VEM. A VEM is registered and host a virtual ethernet interface when a Virtual Machine attaches to such VEM by using virtual ethernet interface. A unique identifier, logical module number, is assigned for every VEM. This object contains value of zero if VEM is directly attached to the switch.

cvnVethHostAddrTypeInetAddressTyperead-only
.1.3.6.1.4.1.9.9.710.1.1.1.1.5

The type of Internet address of the VEM which hosts the VM.

cvnVethHostAddrInetAddressread-only
.1.3.6.1.4.1.9.9.710.1.1.1.1.6

The Internet address of the VEM which hosts the VM. The type of this address is determined by the value of the cvnVethHostAddrType object. This object also indicates the management address of the VEM. Value of this object may be changed when virtual ethernet interface moves from one VEM to another VEM.

cvnVethPortProfileUsedSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.710.1.1.1.1.7

The name of port profile which has been applied to the current virtual ethernet interface. Port Profile contains a set of configuration parameters. For example, switchport mode, channel group no., channel group mode, security policy. Port profile is assigned during the registration of virtual ethernet interface.

cvnVethIfProfileAliasSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.710.1.1.1.1.8

The profile alias as seen in external virtualization server for the profile used by this virtual ethernet interface.

cvnVethIfAdditionalStateINTEGERread-only
.1.3.6.1.4.1.9.9.710.1.1.1.1.9

This object indicates the additional state of the virtual ethernet interface. none - no additional state. participating - interface is up and participating. Virtual machine is currently connected to system using this interface. suspended - interface is down and has been suspended. errDisabled - interface is down due to error disabled. nonParticipating - interface is up but not participating.

cvnVethStateReasonSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.710.1.1.1.1.10

This object indicates the reason for the additional state specified in cvnVethIfAdditionalState.

cvnPinningEntryCvnPinningEntrynot-accessible
.1.3.6.1.4.1.9.9.710.1.1.2.1

An entry containing pinning management information for a particular virtual ethernet interface. Entry is created by the system when a virtual Ethernet interface with pinning functionality is registered to VSM. Entry is removed when a virtual Ethernet interface with pinning functionality is removed from VSM.

cvnPinnedSubGrpIdInteger32read-write
.1.3.6.1.4.1.9.9.710.1.1.2.1.1

This object indicates the sub-group ID to which virtual ethernet interface is pinned. This object returns negative vlaue (-1) if subgroup id is not assigned.

cvnConnecteeEntryCvnConnecteeEntrynot-accessible
.1.3.6.1.4.1.9.9.710.1.2.1.1

An entry containing management information for a particular connectee. Entry is created when a connectee connects to VSM. Entry is deleted when a connectee has been disconnected.

cvnConnecteeAttachTypeINTEGERread-only
.1.3.6.1.4.1.9.9.710.1.2.1.1.1

This object indicates how virtual ethernet interface is attached to this system. none - virtual ethernet interface is not participating. vem - Always a dynamic attachment. For this type of attachment switching is done by host at software layer. niv - A fixed or dynamic attachment. For this type of attachment switching is done in asics

cvnDVSPortUnsigned32read-only
.1.3.6.1.4.1.9.9.710.1.2.1.1.2

This object indicates the port of DVS to which virtual ethernet interface is attached.

cvnConnecteeNameSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.710.1.2.1.1.3

This object indicates the name of the connectee attached to virtual ethernet interface. For example it will return name of virtual machine or host connected to the system

cvnConnecteeUuidSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.710.1.2.1.1.4

This object indicates the UUID of the connectee attached to this virtual ethernet interface.

cvnConnecteeTypeINTEGERread-only
.1.3.6.1.4.1.9.9.710.1.2.1.1.5

This object indicates the type of connectee attached to this virtual ethernet interface. Connectee type can be host, Virtual Machine from different vendors etc. unknown - The type of connectee is unknown. vmwareVm - Connectee is a Virtual Machine vmwareHost - Connectee is a host

cvnConnecteeMacMacAddressread-only
.1.3.6.1.4.1.9.9.710.1.2.1.1.6

This object indicates the MAC address of the connectee.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→