Home/Catalog/CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB

CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB

AI MIB Summary

The CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB facilitates the monitoring and management of Universally Unique Identifier (UUID) pool configurations within Cisco Unified Computing System (UCS) environments. It exposes metrics related to UUID pool allocation, reservation status, and range definitions to ensure unique identifier assignment for server blades and virtual machines.

MIB representation of the Cisco Unified Computing System UUIDPOOL management information model package
Main OID:
cucsUuidpoolObjects.1.3.6.1.4.1.9.9.719.1.51
62
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

62 total
Object Name
cucsUuidpoolObjects
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.719.1.51
cucsUuidpoolAddrTable
SEQUENCE OF CucsUuidpoolAddrEntry
.1.3.6.1.4.1.9.9.719.1.51.1
cucsUuidpoolAddrEntry
CucsUuidpoolAddrEntry
.1.3.6.1.4.1.9.9.719.1.51.1.1
cucsUuidpoolAddrInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.1.1.1
cucsUuidpoolAddrDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.1.1.2
cucsUuidpoolAddrRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.1.1.3
cucsUuidpoolAddrAssignedro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.51.1.1.4
cucsUuidpoolAddrAssignedToDnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.1.1.5
cucsUuidpoolAddrIdro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.1.1.6
cucsUuidpoolAddrOwnerro
CucsPoolElementOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.51.1.1.7
cucsUuidpoolAddrGlobalAssignedCntro
Gauge32
.1.3.6.1.4.1.9.9.719.1.51.1.1.8
cucsUuidpoolAddrGlobalDefinedCntro
Gauge32
.1.3.6.1.4.1.9.9.719.1.51.1.1.9
cucsUuidpoolBlockTable
SEQUENCE OF CucsUuidpoolBlockEntry
.1.3.6.1.4.1.9.9.719.1.51.2
cucsUuidpoolBlockEntry
CucsUuidpoolBlockEntry
.1.3.6.1.4.1.9.9.719.1.51.2.1
cucsUuidpoolBlockInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.2.1.1
cucsUuidpoolBlockDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.2.1.2
cucsUuidpoolBlockRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.2.1.3
cucsUuidpoolBlockFromro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.51.2.1.4
cucsUuidpoolBlockToro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.51.2.1.5
cucsUuidpoolFormatTable
SEQUENCE OF CucsUuidpoolFormatEntry
.1.3.6.1.4.1.9.9.719.1.51.3
cucsUuidpoolFormatEntry
CucsUuidpoolFormatEntry
.1.3.6.1.4.1.9.9.719.1.51.3.1
cucsUuidpoolFormatInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.3.1.1
cucsUuidpoolFormatDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.3.1.2
cucsUuidpoolFormatRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.3.1.3
cucsUuidpoolFormatFormatro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.51.3.1.4
cucsUuidpoolFormatMaskro
CucsAddressUIDSuffxMask (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.51.3.1.5
cucsUuidpoolPoolTable
SEQUENCE OF CucsUuidpoolPoolEntry
.1.3.6.1.4.1.9.9.719.1.51.4
cucsUuidpoolPoolEntry
CucsUuidpoolPoolEntry
.1.3.6.1.4.1.9.9.719.1.51.4.1
cucsUuidpoolPoolInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.4.1.1
cucsUuidpoolPoolDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.4.1.2
cucsUuidpoolPoolRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.4.1.3
cucsUuidpoolPoolAssignedro
Gauge32
.1.3.6.1.4.1.9.9.719.1.51.4.1.4
cucsUuidpoolPoolDescrro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.4.1.5
cucsUuidpoolPoolIntIdro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.4.1.6
cucsUuidpoolPoolNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.4.1.7
cucsUuidpoolPoolPrefixro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.51.4.1.8
cucsUuidpoolPoolSizero
Gauge32
.1.3.6.1.4.1.9.9.719.1.51.4.1.9
cucsUuidpoolPoolAssignmentOrderro
CucsUuidpoolPoolAssignmentOrder (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.51.4.1.10
cucsUuidpoolPoolPolicyLevelro
Gauge32
.1.3.6.1.4.1.9.9.719.1.51.4.1.11
cucsUuidpoolPoolPolicyOwnerro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.51.4.1.12
cucsUuidpoolPoolableTable
SEQUENCE OF CucsUuidpoolPoolableEntry
.1.3.6.1.4.1.9.9.719.1.51.5
cucsUuidpoolPoolableEntry
CucsUuidpoolPoolableEntry
.1.3.6.1.4.1.9.9.719.1.51.5.1
cucsUuidpoolPoolableInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.5.1.1
cucsUuidpoolPoolableDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.5.1.2
cucsUuidpoolPoolableRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.5.1.3
cucsUuidpoolPoolableIdro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.51.5.1.4
cucsUuidpoolPoolablePoolDnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.5.1.5
cucsUuidpoolPooledTable
SEQUENCE OF CucsUuidpoolPooledEntry
.1.3.6.1.4.1.9.9.719.1.51.6
cucsUuidpoolPooledEntry
CucsUuidpoolPooledEntry
.1.3.6.1.4.1.9.9.719.1.51.6.1
cucsUuidpoolPooledInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.6.1.1
cucsUuidpoolPooledDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.6.1.2
cucsUuidpoolPooledRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.6.1.3
cucsUuidpoolPooledAssignedro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.51.6.1.4
cucsUuidpoolPooledAssignedToDnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.6.1.5
cucsUuidpoolPooledIdro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.51.6.1.6
cucsUuidpoolPooledPoolableDnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.6.1.7
cucsUuidpoolPooledPrevAssignedToDnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.6.1.8
cucsUuidpoolUniverseTable
SEQUENCE OF CucsUuidpoolUniverseEntry
.1.3.6.1.4.1.9.9.719.1.51.7
cucsUuidpoolUniverseEntry
CucsUuidpoolUniverseEntry
.1.3.6.1.4.1.9.9.719.1.51.7.1
cucsUuidpoolUniverseInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.7.1.1
cucsUuidpoolUniverseDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.51.7.1.2
cucsUuidpoolUniverseRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.51.7.1.3

CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB Technical Reference Overview

The CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB SNMP MIB module published by Cisco defines 62 managed OID objects, including 47 scalar/column metrics, 7 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.719.1.51. Key tabular structures include cucsUuidpoolAddrTable, cucsUuidpoolBlockTable, cucsUuidpoolFormatTable, cucsUuidpoolPoolTable, cucsUuidpoolPoolableTable, cucsUuidpoolPooledTable.

Key OID Definitions in CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB

cucsUuidpoolObjectsMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.719.1.51

MIB representation of the Cisco Unified Computing System UUIDPOOL management information model package

cucsUuidpoolAddrTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.51.1

Cisco UCS uuidpool:Addr managed object table

cucsUuidpoolBlockTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.51.2

Cisco UCS uuidpool:Block managed object table

cucsUuidpoolFormatTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.51.3

Cisco UCS uuidpool:Format managed object table

cucsUuidpoolPoolTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.51.4

Cisco UCS uuidpool:Pool managed object table

cucsUuidpoolPoolableTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.51.5

Cisco UCS uuidpool:Poolable managed object table

cucsUuidpoolPooledTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.51.6

Cisco UCS uuidpool:Pooled managed object table

cucsUuidpoolUniverseTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.51.7

Cisco UCS uuidpool:Universe managed object table

cucsUuidpoolAddrEntryCucsUuidpoolAddrEntrynot-accessible
.1.3.6.1.4.1.9.9.719.1.51.1.1

Entry for the cucsUuidpoolAddrTable table.

cucsUuidpoolAddrInstanceIdCucsManagedObjectIdnot-accessible
.1.3.6.1.4.1.9.9.719.1.51.1.1.1

Instance identifier of the managed object.

cucsUuidpoolAddrDnCucsManagedObjectDnread-only
.1.3.6.1.4.1.9.9.719.1.51.1.1.2

Cisco UCS uuidpool:Addr:dn managed object property

cucsUuidpoolAddrRnSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.51.1.1.3

Cisco UCS uuidpool:Addr:rn managed object property

cucsUuidpoolAddrAssignedTruthValueread-only
.1.3.6.1.4.1.9.9.719.1.51.1.1.4

Cisco UCS uuidpool:Addr:assigned managed object property

cucsUuidpoolAddrAssignedToDnSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.51.1.1.5

Cisco UCS uuidpool:Addr:assignedToDn managed object property

cucsUuidpoolAddrIdSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.51.1.1.6

Cisco UCS uuidpool:Addr:id managed object property

cucsUuidpoolAddrOwnerCucsPoolElementOwnerread-only
.1.3.6.1.4.1.9.9.719.1.51.1.1.7

Cisco UCS uuidpool:Addr:owner managed object property

cucsUuidpoolAddrGlobalAssignedCntGauge32read-only
.1.3.6.1.4.1.9.9.719.1.51.1.1.8

Cisco UCS uuidpool:Addr:globalAssignedCnt managed object property

cucsUuidpoolAddrGlobalDefinedCntGauge32read-only
.1.3.6.1.4.1.9.9.719.1.51.1.1.9

Cisco UCS uuidpool:Addr:globalDefinedCnt managed object property

cucsUuidpoolBlockEntryCucsUuidpoolBlockEntrynot-accessible
.1.3.6.1.4.1.9.9.719.1.51.2.1

Entry for the cucsUuidpoolBlockTable table.

cucsUuidpoolBlockInstanceIdCucsManagedObjectIdnot-accessible
.1.3.6.1.4.1.9.9.719.1.51.2.1.1

Instance identifier of the managed object.

cucsUuidpoolBlockDnCucsManagedObjectDnread-only
.1.3.6.1.4.1.9.9.719.1.51.2.1.2

Cisco UCS uuidpool:Block:dn managed object property

cucsUuidpoolBlockRnSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.51.2.1.3

Cisco UCS uuidpool:Block:rn managed object property

cucsUuidpoolBlockFromUnsigned64read-only
.1.3.6.1.4.1.9.9.719.1.51.2.1.4

Cisco UCS uuidpool:Block:from managed object property

cucsUuidpoolBlockToUnsigned64read-only
.1.3.6.1.4.1.9.9.719.1.51.2.1.5

Cisco UCS uuidpool:Block:to managed object property

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→