CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB
The CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB facilitates the monitoring and management of Universally Unique Identifier (UUID) pool configurations within Cisco Unified Computing System (UCS) environments. It exposes metrics related to UUID pool allocation, reservation status, and range definitions to ensure unique identifier assignment for server blades and virtual machines.
Imported Objects
Objects
62 total| Object Name |
|---|
cucsUuidpoolObjects MODULE-IDENTITY .1.3.6.1.4.1.9.9.719.1.51 |
cucsUuidpoolAddrTable SEQUENCE OF CucsUuidpoolAddrEntry .1.3.6.1.4.1.9.9.719.1.51.1 |
cucsUuidpoolAddrEntry CucsUuidpoolAddrEntry .1.3.6.1.4.1.9.9.719.1.51.1.1 |
cucsUuidpoolAddrInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.1.1.1 |
cucsUuidpoolAddrDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.1.1.2 |
cucsUuidpoolAddrRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.1.1.3 |
cucsUuidpoolAddrAssignedro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.51.1.1.4 |
cucsUuidpoolAddrAssignedToDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.1.1.5 |
cucsUuidpoolAddrIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.1.1.6 |
cucsUuidpoolAddrOwnerro CucsPoolElementOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.51.1.1.7 |
cucsUuidpoolAddrGlobalAssignedCntro Gauge32 .1.3.6.1.4.1.9.9.719.1.51.1.1.8 |
cucsUuidpoolAddrGlobalDefinedCntro Gauge32 .1.3.6.1.4.1.9.9.719.1.51.1.1.9 |
cucsUuidpoolBlockTable SEQUENCE OF CucsUuidpoolBlockEntry .1.3.6.1.4.1.9.9.719.1.51.2 |
cucsUuidpoolBlockEntry CucsUuidpoolBlockEntry .1.3.6.1.4.1.9.9.719.1.51.2.1 |
cucsUuidpoolBlockInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.2.1.1 |
cucsUuidpoolBlockDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.2.1.2 |
cucsUuidpoolBlockRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.2.1.3 |
cucsUuidpoolBlockFromro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.51.2.1.4 |
cucsUuidpoolBlockToro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.51.2.1.5 |
cucsUuidpoolFormatTable SEQUENCE OF CucsUuidpoolFormatEntry .1.3.6.1.4.1.9.9.719.1.51.3 |
cucsUuidpoolFormatEntry CucsUuidpoolFormatEntry .1.3.6.1.4.1.9.9.719.1.51.3.1 |
cucsUuidpoolFormatInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.3.1.1 |
cucsUuidpoolFormatDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.3.1.2 |
cucsUuidpoolFormatRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.3.1.3 |
cucsUuidpoolFormatFormatro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.51.3.1.4 |
cucsUuidpoolFormatMaskro CucsAddressUIDSuffxMask (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.51.3.1.5 |
cucsUuidpoolPoolTable SEQUENCE OF CucsUuidpoolPoolEntry .1.3.6.1.4.1.9.9.719.1.51.4 |
cucsUuidpoolPoolEntry CucsUuidpoolPoolEntry .1.3.6.1.4.1.9.9.719.1.51.4.1 |
cucsUuidpoolPoolInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.1 |
cucsUuidpoolPoolDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.2 |
cucsUuidpoolPoolRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.3 |
cucsUuidpoolPoolAssignedro Gauge32 .1.3.6.1.4.1.9.9.719.1.51.4.1.4 |
cucsUuidpoolPoolDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.5 |
cucsUuidpoolPoolIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.6 |
cucsUuidpoolPoolNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.7 |
cucsUuidpoolPoolPrefixro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.51.4.1.8 |
cucsUuidpoolPoolSizero Gauge32 .1.3.6.1.4.1.9.9.719.1.51.4.1.9 |
cucsUuidpoolPoolAssignmentOrderro CucsUuidpoolPoolAssignmentOrder (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.10 |
cucsUuidpoolPoolPolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.51.4.1.11 |
cucsUuidpoolPoolPolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.12 |
cucsUuidpoolPoolableTable SEQUENCE OF CucsUuidpoolPoolableEntry .1.3.6.1.4.1.9.9.719.1.51.5 |
cucsUuidpoolPoolableEntry CucsUuidpoolPoolableEntry .1.3.6.1.4.1.9.9.719.1.51.5.1 |
cucsUuidpoolPoolableInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.5.1.1 |
cucsUuidpoolPoolableDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.5.1.2 |
cucsUuidpoolPoolableRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.5.1.3 |
cucsUuidpoolPoolableIdro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.51.5.1.4 |
cucsUuidpoolPoolablePoolDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.5.1.5 |
cucsUuidpoolPooledTable SEQUENCE OF CucsUuidpoolPooledEntry .1.3.6.1.4.1.9.9.719.1.51.6 |
cucsUuidpoolPooledEntry CucsUuidpoolPooledEntry .1.3.6.1.4.1.9.9.719.1.51.6.1 |
cucsUuidpoolPooledInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.6.1.1 |
cucsUuidpoolPooledDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.6.1.2 |
cucsUuidpoolPooledRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.6.1.3 |
cucsUuidpoolPooledAssignedro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.51.6.1.4 |
cucsUuidpoolPooledAssignedToDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.6.1.5 |
cucsUuidpoolPooledIdro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.51.6.1.6 |
cucsUuidpoolPooledPoolableDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.6.1.7 |
cucsUuidpoolPooledPrevAssignedToDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.6.1.8 |
cucsUuidpoolUniverseTable SEQUENCE OF CucsUuidpoolUniverseEntry .1.3.6.1.4.1.9.9.719.1.51.7 |
cucsUuidpoolUniverseEntry CucsUuidpoolUniverseEntry .1.3.6.1.4.1.9.9.719.1.51.7.1 |
cucsUuidpoolUniverseInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.7.1.1 |
cucsUuidpoolUniverseDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.7.1.2 |
cucsUuidpoolUniverseRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.7.1.3 |
CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB Technical Reference Overview
The CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB SNMP MIB module published by Cisco defines 62 managed OID objects, including 47 scalar/column metrics, 7 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.719.1.51. Key tabular structures include cucsUuidpoolAddrTable, cucsUuidpoolBlockTable, cucsUuidpoolFormatTable, cucsUuidpoolPoolTable, cucsUuidpoolPoolableTable, cucsUuidpoolPooledTable.
Key OID Definitions in CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB
.1.3.6.1.4.1.9.9.719.1.51MIB representation of the Cisco Unified Computing System UUIDPOOL management information model package
.1.3.6.1.4.1.9.9.719.1.51.1Cisco UCS uuidpool:Addr managed object table
.1.3.6.1.4.1.9.9.719.1.51.2Cisco UCS uuidpool:Block managed object table
.1.3.6.1.4.1.9.9.719.1.51.3Cisco UCS uuidpool:Format managed object table
.1.3.6.1.4.1.9.9.719.1.51.4Cisco UCS uuidpool:Pool managed object table
.1.3.6.1.4.1.9.9.719.1.51.5Cisco UCS uuidpool:Poolable managed object table
.1.3.6.1.4.1.9.9.719.1.51.6Cisco UCS uuidpool:Pooled managed object table
.1.3.6.1.4.1.9.9.719.1.51.7Cisco UCS uuidpool:Universe managed object table
.1.3.6.1.4.1.9.9.719.1.51.1.1Entry for the cucsUuidpoolAddrTable table.
.1.3.6.1.4.1.9.9.719.1.51.1.1.1Instance identifier of the managed object.
.1.3.6.1.4.1.9.9.719.1.51.1.1.2Cisco UCS uuidpool:Addr:dn managed object property
.1.3.6.1.4.1.9.9.719.1.51.1.1.3Cisco UCS uuidpool:Addr:rn managed object property
.1.3.6.1.4.1.9.9.719.1.51.1.1.4Cisco UCS uuidpool:Addr:assigned managed object property
.1.3.6.1.4.1.9.9.719.1.51.1.1.5Cisco UCS uuidpool:Addr:assignedToDn managed object property
.1.3.6.1.4.1.9.9.719.1.51.1.1.6Cisco UCS uuidpool:Addr:id managed object property
.1.3.6.1.4.1.9.9.719.1.51.1.1.7Cisco UCS uuidpool:Addr:owner managed object property
.1.3.6.1.4.1.9.9.719.1.51.1.1.8Cisco UCS uuidpool:Addr:globalAssignedCnt managed object property
.1.3.6.1.4.1.9.9.719.1.51.1.1.9Cisco UCS uuidpool:Addr:globalDefinedCnt managed object property
.1.3.6.1.4.1.9.9.719.1.51.2.1Entry for the cucsUuidpoolBlockTable table.
.1.3.6.1.4.1.9.9.719.1.51.2.1.1Instance identifier of the managed object.
.1.3.6.1.4.1.9.9.719.1.51.2.1.2Cisco UCS uuidpool:Block:dn managed object property
.1.3.6.1.4.1.9.9.719.1.51.2.1.3Cisco UCS uuidpool:Block:rn managed object property
.1.3.6.1.4.1.9.9.719.1.51.2.1.4Cisco UCS uuidpool:Block:from managed object property
.1.3.6.1.4.1.9.9.719.1.51.2.1.5Cisco UCS uuidpool:Block:to managed object property
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.