CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB
The CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB facilitates the monitoring and management of Universally Unique Identifier (UUID) pool configurations within Cisco Unified Computing System (UCS) environments. It exposes metrics related to UUID pool allocation, reservation status, and range definitions to ensure unique identifier assignment for server blades and virtual machines.
Imported Objects
Objects
62 total| Object Name |
|---|
cucsUuidpoolObjectsMIB representation of the Cisco Unified Computing System
UUIDPOOL management information model package MODULE-IDENTITY .1.3.6.1.4.1.9.9.719.1.51 |
cucsUuidpoolAddrTableCisco UCS uuidpool:Addr managed object table SEQUENCE OF CucsUuidpoolAddrEntry .1.3.6.1.4.1.9.9.719.1.51.1 |
cucsUuidpoolAddrEntryEntry for the cucsUuidpoolAddrTable table. CucsUuidpoolAddrEntry .1.3.6.1.4.1.9.9.719.1.51.1.1 |
cucsUuidpoolAddrInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.1.1.1 |
cucsUuidpoolAddrDnCisco UCS uuidpool:Addr:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.1.1.2 |
cucsUuidpoolAddrRnCisco UCS uuidpool:Addr:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.1.1.3 |
cucsUuidpoolAddrAssignedCisco UCS uuidpool:Addr:assigned managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.51.1.1.4 |
cucsUuidpoolAddrAssignedToDnCisco UCS uuidpool:Addr:assignedToDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.1.1.5 |
cucsUuidpoolAddrIdCisco UCS uuidpool:Addr:id managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.1.1.6 |
cucsUuidpoolAddrOwnerCisco UCS uuidpool:Addr:owner managed object propertyro CucsPoolElementOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.51.1.1.7 |
cucsUuidpoolAddrGlobalAssignedCntCisco UCS uuidpool:Addr:globalAssignedCnt managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.51.1.1.8 |
cucsUuidpoolAddrGlobalDefinedCntCisco UCS uuidpool:Addr:globalDefinedCnt managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.51.1.1.9 |
cucsUuidpoolBlockTableCisco UCS uuidpool:Block managed object table SEQUENCE OF CucsUuidpoolBlockEntry .1.3.6.1.4.1.9.9.719.1.51.2 |
cucsUuidpoolBlockEntryEntry for the cucsUuidpoolBlockTable table. CucsUuidpoolBlockEntry .1.3.6.1.4.1.9.9.719.1.51.2.1 |
cucsUuidpoolBlockInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.2.1.1 |
cucsUuidpoolBlockDnCisco UCS uuidpool:Block:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.2.1.2 |
cucsUuidpoolBlockRnCisco UCS uuidpool:Block:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.2.1.3 |
cucsUuidpoolBlockFromCisco UCS uuidpool:Block:from managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.51.2.1.4 |
cucsUuidpoolBlockToCisco UCS uuidpool:Block:to managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.51.2.1.5 |
cucsUuidpoolFormatTableCisco UCS uuidpool:Format managed object table SEQUENCE OF CucsUuidpoolFormatEntry .1.3.6.1.4.1.9.9.719.1.51.3 |
cucsUuidpoolFormatEntryEntry for the cucsUuidpoolFormatTable table. CucsUuidpoolFormatEntry .1.3.6.1.4.1.9.9.719.1.51.3.1 |
cucsUuidpoolFormatInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.3.1.1 |
cucsUuidpoolFormatDnCisco UCS uuidpool:Format:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.3.1.2 |
cucsUuidpoolFormatRnCisco UCS uuidpool:Format:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.3.1.3 |
cucsUuidpoolFormatFormatCisco UCS uuidpool:Format:format managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.51.3.1.4 |
cucsUuidpoolFormatMaskCisco UCS uuidpool:Format:mask managed object propertyro CucsAddressUIDSuffxMask (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.51.3.1.5 |
cucsUuidpoolPoolTableCisco UCS uuidpool:Pool managed object table SEQUENCE OF CucsUuidpoolPoolEntry .1.3.6.1.4.1.9.9.719.1.51.4 |
cucsUuidpoolPoolEntryEntry for the cucsUuidpoolPoolTable table. CucsUuidpoolPoolEntry .1.3.6.1.4.1.9.9.719.1.51.4.1 |
cucsUuidpoolPoolInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.1 |
cucsUuidpoolPoolDnCisco UCS uuidpool:Pool:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.2 |
cucsUuidpoolPoolRnCisco UCS uuidpool:Pool:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.3 |
cucsUuidpoolPoolAssignedCisco UCS uuidpool:Pool:assigned managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.51.4.1.4 |
cucsUuidpoolPoolDescrCisco UCS uuidpool:Pool:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.5 |
cucsUuidpoolPoolIntIdCisco UCS uuidpool:Pool:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.6 |
cucsUuidpoolPoolNameCisco UCS uuidpool:Pool:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.7 |
cucsUuidpoolPoolPrefixCisco UCS uuidpool:Pool:prefix managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.51.4.1.8 |
cucsUuidpoolPoolSizeCisco UCS uuidpool:Pool:size managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.51.4.1.9 |
cucsUuidpoolPoolAssignmentOrderCisco UCS uuidpool:Pool:assignmentOrder managed object propertyro CucsUuidpoolPoolAssignmentOrder (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.10 |
cucsUuidpoolPoolPolicyLevelCisco UCS uuidpool:Pool:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.51.4.1.11 |
cucsUuidpoolPoolPolicyOwnerCisco UCS uuidpool:Pool:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.51.4.1.12 |
cucsUuidpoolPoolableTableCisco UCS uuidpool:Poolable managed object table SEQUENCE OF CucsUuidpoolPoolableEntry .1.3.6.1.4.1.9.9.719.1.51.5 |
cucsUuidpoolPoolableEntryEntry for the cucsUuidpoolPoolableTable table. CucsUuidpoolPoolableEntry .1.3.6.1.4.1.9.9.719.1.51.5.1 |
cucsUuidpoolPoolableInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.5.1.1 |
cucsUuidpoolPoolableDnCisco UCS uuidpool:Poolable:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.5.1.2 |
cucsUuidpoolPoolableRnCisco UCS uuidpool:Poolable:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.5.1.3 |
cucsUuidpoolPoolableIdCisco UCS uuidpool:Poolable:id managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.51.5.1.4 |
cucsUuidpoolPoolablePoolDnCisco UCS uuidpool:Poolable:poolDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.5.1.5 |
cucsUuidpoolPooledTableCisco UCS uuidpool:Pooled managed object table SEQUENCE OF CucsUuidpoolPooledEntry .1.3.6.1.4.1.9.9.719.1.51.6 |
cucsUuidpoolPooledEntryEntry for the cucsUuidpoolPooledTable table. CucsUuidpoolPooledEntry .1.3.6.1.4.1.9.9.719.1.51.6.1 |
cucsUuidpoolPooledInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.6.1.1 |
cucsUuidpoolPooledDnCisco UCS uuidpool:Pooled:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.6.1.2 |
cucsUuidpoolPooledRnCisco UCS uuidpool:Pooled:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.6.1.3 |
cucsUuidpoolPooledAssignedCisco UCS uuidpool:Pooled:assigned managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.51.6.1.4 |
cucsUuidpoolPooledAssignedToDnCisco UCS uuidpool:Pooled:assignedToDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.6.1.5 |
cucsUuidpoolPooledIdCisco UCS uuidpool:Pooled:id managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.51.6.1.6 |
cucsUuidpoolPooledPoolableDnCisco UCS uuidpool:Pooled:poolableDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.6.1.7 |
cucsUuidpoolPooledPrevAssignedToDnCisco UCS uuidpool:Pooled:prevAssignedToDn managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.6.1.8 |
cucsUuidpoolUniverseTableCisco UCS uuidpool:Universe managed object table SEQUENCE OF CucsUuidpoolUniverseEntry .1.3.6.1.4.1.9.9.719.1.51.7 |
cucsUuidpoolUniverseEntryEntry for the cucsUuidpoolUniverseTable table. CucsUuidpoolUniverseEntry .1.3.6.1.4.1.9.9.719.1.51.7.1 |
cucsUuidpoolUniverseInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.7.1.1 |
cucsUuidpoolUniverseDnCisco UCS uuidpool:Universe:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.51.7.1.2 |
cucsUuidpoolUniverseRnCisco UCS uuidpool:Universe:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.51.7.1.3 |
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-ENTITY-VENDORTYPE-OID-MIB maps Cisco-specific hardware component identifiers to the ENTITY-MIB's entPhysicalTable, enabling precise differentiation of physical device types such as line cards, power supplies, and fans within Cisco infrastructure. This mapping ensures that SNMP management systems can accurately correlate physical inventory entries with vendor-specific component definitions for accurate device discovery and monitoring.
The CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB provides SNMP-based monitoring and management of Cisco Unified Computing System (UCS) hardware components, including chassis, blades, fabric interconnects, and power supplies. It exposes critical operational metrics such as device status, port states, temperature readings, fan speeds, and power consumption data for infrastructure health assessment.
The CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB enables SNMP-based monitoring and management of physical and virtual network adapter interfaces, including link status, traffic counters, error statistics, and port configuration parameters, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers.
The CISCO-UNIFIED-COMPUTING-TC-MIB module defines standard textual conventions and data type definitions required for monitoring Cisco Unified Computing System (UCS) hardware components, including server blades, fabric interconnects, and chassis resources. These definitions enable consistent interpretation of specific UCS metrics such as power supply status, fan speeds, thermal readings, and port utilization across SNMP management applications.
The CISCO-UNIFIED-COMPUTING-FABRIC-MIB enables SNMP-based monitoring and management of the Cisco UCS Fabric Interconnects and associated fabric switching infrastructure, exposing metrics for port states, link utilization, error counters, and fabric topology status. It facilitates granular visibility into the physical and logical fabric layers, including uplink/downlink interfaces, VLAN configurations, and fabric failover conditions within the unified computing environment.
The STARENT-MIB module provides SNMP management and monitoring capabilities for Cisco ASR 5000 and ASR 5500 multimedia core platforms, specifically exposing metrics related to 2G/3G/4G and WiFi subscriber sessions, inline service states, and carrier-class high-availability status.