CISCO-UNIFIED-COMPUTING-TOP-MIB
The CISCO-UNIFIED-COMPUTING-TOP-MIB provides SNMP access to the Cisco Unified Computing System (UCS) Topology Management Information Model, enabling the monitoring of physical and logical component relationships, including server blades, fabric interconnects, and chassis hierarchies. This module facilitates the discovery and tracking of device connectivity states, port mappings, and topology integrity within the UCS fabric infrastructure.
Imported Objects
Objects
49 total| Object Name |
|---|
cucsTopObjectsMIB representation of the Cisco Unified Computing System
TOP management information model package MODULE-IDENTITY .1.3.6.1.4.1.9.9.719.1.49 |
cucsTopMetaInfTableCisco UCS top:MetaInf managed object table SEQUENCE OF CucsTopMetaInfEntry .1.3.6.1.4.1.9.9.719.1.49.1 |
cucsTopMetaInfEntryEntry for the cucsTopMetaInfTable table. CucsTopMetaInfEntry .1.3.6.1.4.1.9.9.719.1.49.1.1 |
cucsTopMetaInfInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.49.1.1.1 |
cucsTopMetaInfDnCisco UCS top:MetaInf:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.49.1.1.2 |
cucsTopMetaInfRnCisco UCS top:MetaInf:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.1.1.3 |
cucsTopMetaInfEcodeCisco UCS top:MetaInf:ecode managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.1.1.4 |
cucsTopMetaInfNameCisco UCS top:MetaInf:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.1.1.5 |
cucsTopRootTableCisco UCS top:Root managed object table SEQUENCE OF CucsTopRootEntry .1.3.6.1.4.1.9.9.719.1.49.2 |
cucsTopRootEntryEntry for the cucsTopRootTable table. CucsTopRootEntry .1.3.6.1.4.1.9.9.719.1.49.2.1 |
cucsTopRootInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.49.2.1.1 |
cucsTopRootDnCisco UCS top:Root:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.49.2.1.2 |
cucsTopRootRnCisco UCS top:Root:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.2.1.3 |
cucsTopSystemTableCisco UCS top:System managed object table SEQUENCE OF CucsTopSystemEntry .1.3.6.1.4.1.9.9.719.1.49.3 |
cucsTopSystemEntryEntry for the cucsTopSystemTable table. CucsTopSystemEntry .1.3.6.1.4.1.9.9.719.1.49.3.1 |
cucsTopSystemInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.49.3.1.1 |
cucsTopSystemDnCisco UCS top:System:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.49.3.1.2 |
cucsTopSystemRnCisco UCS top:System:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.3.1.3 |
cucsTopSystemAddressCisco UCS top:System:address managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.49.3.1.4 |
cucsTopSystemCurrentTimeCisco UCS top:System:currentTime managed object propertyro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.49.3.1.5 |
cucsTopSystemModeCisco UCS top:System:mode managed object propertyro CucsTopMode (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.49.3.1.6 |
cucsTopSystemNameCisco UCS top:System:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.3.1.7 |
cucsTopSystemSystemUpTimeCisco UCS top:System:systemUpTime managed object propertyro TimeIntervalSec (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.49.3.1.8 |
cucsTopSystemDescrCisco UCS top:System:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.3.1.9 |
cucsTopSystemOwnerCisco UCS top:System:owner managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.3.1.10 |
cucsTopSystemSiteCisco UCS top:System:site managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.3.1.11 |
cucsTopSystemIpv6AddrCisco UCS top:System:ipv6Addr managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.49.3.1.12 |
cucsTopSysDefaultsTableCisco UCS top:SysDefaults managed object table SEQUENCE OF CucsTopSysDefaultsEntry .1.3.6.1.4.1.9.9.719.1.49.4 |
cucsTopSysDefaultsEntryEntry for the cucsTopSysDefaultsTable table. CucsTopSysDefaultsEntry .1.3.6.1.4.1.9.9.719.1.49.4.1 |
cucsTopSysDefaultsInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.49.4.1.1 |
cucsTopSysDefaultsDnCisco UCS top:SysDefaults:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.49.4.1.2 |
cucsTopSysDefaultsRnCisco UCS top:SysDefaults:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.4.1.3 |
cucsTopInfoPolicyTableCisco UCS top:InfoPolicy managed object table SEQUENCE OF CucsTopInfoPolicyEntry .1.3.6.1.4.1.9.9.719.1.49.5 |
cucsTopInfoPolicyEntryEntry for the cucsTopInfoPolicyTable table. CucsTopInfoPolicyEntry .1.3.6.1.4.1.9.9.719.1.49.5.1 |
cucsTopInfoPolicyInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.49.5.1.1 |
cucsTopInfoPolicyDnCisco UCS top:InfoPolicy:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.49.5.1.2 |
cucsTopInfoPolicyRnCisco UCS top:InfoPolicy:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.5.1.3 |
cucsTopInfoPolicyStateCisco UCS top:InfoPolicy:state managed object propertyro CucsTopInfoPolicyState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.49.5.1.4 |
cucsTopInfoSyncPolicyTableCisco UCS top:InfoSyncPolicy managed object table SEQUENCE OF CucsTopInfoSyncPolicyEntry .1.3.6.1.4.1.9.9.719.1.49.6 |
cucsTopInfoSyncPolicyEntryEntry for the cucsTopInfoSyncPolicyTable table. CucsTopInfoSyncPolicyEntry .1.3.6.1.4.1.9.9.719.1.49.6.1 |
cucsTopInfoSyncPolicyInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.49.6.1.1 |
cucsTopInfoSyncPolicyDnCisco UCS top:InfoSyncPolicy:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.49.6.1.2 |
cucsTopInfoSyncPolicyRnCisco UCS top:InfoSyncPolicy:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.6.1.3 |
cucsTopInfoSyncPolicyDescrCisco UCS top:InfoSyncPolicy:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.6.1.4 |
cucsTopInfoSyncPolicyIntIdCisco UCS top:InfoSyncPolicy:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.6.1.5 |
cucsTopInfoSyncPolicyNameCisco UCS top:InfoSyncPolicy:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.49.6.1.6 |
cucsTopInfoSyncPolicyPolicyLevelCisco UCS top:InfoSyncPolicy:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.49.6.1.7 |
cucsTopInfoSyncPolicyPolicyOwnerCisco UCS top:InfoSyncPolicy:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.49.6.1.8 |
cucsTopInfoSyncPolicyStateCisco UCS top:InfoSyncPolicy:state managed object propertyro CucsTopInfoSyncPolicyState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.49.6.1.9 |
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-ENTITY-VENDORTYPE-OID-MIB maps Cisco-specific hardware component identifiers to the ENTITY-MIB's entPhysicalTable, enabling precise differentiation of physical device types such as line cards, power supplies, and fans within Cisco infrastructure. This mapping ensures that SNMP management systems can accurately correlate physical inventory entries with vendor-specific component definitions for accurate device discovery and monitoring.
The CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB provides SNMP-based monitoring and management of Cisco Unified Computing System (UCS) hardware components, including chassis, blades, fabric interconnects, and power supplies. It exposes critical operational metrics such as device status, port states, temperature readings, fan speeds, and power consumption data for infrastructure health assessment.
The CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB enables SNMP-based monitoring and management of physical and virtual network adapter interfaces, including link status, traffic counters, error statistics, and port configuration parameters, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers.
The CISCO-UNIFIED-COMPUTING-TC-MIB module defines standard textual conventions and data type definitions required for monitoring Cisco Unified Computing System (UCS) hardware components, including server blades, fabric interconnects, and chassis resources. These definitions enable consistent interpretation of specific UCS metrics such as power supply status, fan speeds, thermal readings, and port utilization across SNMP management applications.
The CISCO-UNIFIED-COMPUTING-FABRIC-MIB enables SNMP-based monitoring and management of the Cisco UCS Fabric Interconnects and associated fabric switching infrastructure, exposing metrics for port states, link utilization, error counters, and fabric topology status. It facilitates granular visibility into the physical and logical fabric layers, including uplink/downlink interfaces, VLAN configurations, and fabric failover conditions within the unified computing environment.
The STARENT-MIB module provides SNMP management and monitoring capabilities for Cisco ASR 5000 and ASR 5500 multimedia core platforms, specifically exposing metrics related to 2G/3G/4G and WiFi subscriber sessions, inline service states, and carrier-class high-availability status.