CISCO-UNIFIED-COMPUTING-SOL-MIB
The CISCO-UNIFIED-COMPUTING-SOL-MIB facilitates remote console access and out-of-band management for Cisco Unified Computing System (UCS) servers via the Serial Over LAN (SOL) protocol. It exposes management information for monitoring SOL session states, connection availability, and serial port configuration parameters across UCS blade and rack-mounted chassis.
Imported Objects
Objects
38 total| Object Name |
|---|
cucsSolObjectsMIB representation of the Cisco Unified Computing System
SOL management information model package MODULE-IDENTITY .1.3.6.1.4.1.9.9.719.1.43 |
cucsSolConfigTableCisco UCS sol:Config managed object table SEQUENCE OF CucsSolConfigEntry .1.3.6.1.4.1.9.9.719.1.43.1 |
cucsSolConfigEntryEntry for the cucsSolConfigTable table. CucsSolConfigEntry .1.3.6.1.4.1.9.9.719.1.43.1.1 |
cucsSolConfigInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.1 |
cucsSolConfigDnCisco UCS sol:Config:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.2 |
cucsSolConfigRnCisco UCS sol:Config:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.3 |
cucsSolConfigAdminStateCisco UCS sol:Config:adminState managed object propertyro CucsSolAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.4 |
cucsSolConfigDescrCisco UCS sol:Config:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.5 |
cucsSolConfigIntIdCisco UCS sol:Config:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.6 |
cucsSolConfigNameCisco UCS sol:Config:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.7 |
cucsSolConfigSpeedCisco UCS sol:Config:speed managed object propertyro CucsSolSpeed (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.8 |
cucsSolConfigPolicyLevelCisco UCS sol:Config:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.43.1.1.9 |
cucsSolConfigPolicyOwnerCisco UCS sol:Config:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.10 |
cucsSolIfTableCisco UCS sol:If managed object table SEQUENCE OF CucsSolIfEntry .1.3.6.1.4.1.9.9.719.1.43.2 |
cucsSolIfEntryEntry for the cucsSolIfTable table. CucsSolIfEntry .1.3.6.1.4.1.9.9.719.1.43.2.1 |
cucsSolIfInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.1 |
cucsSolIfDnCisco UCS sol:If:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.2 |
cucsSolIfRnCisco UCS sol:If:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.3 |
cucsSolIfAdminStateCisco UCS sol:If:adminState managed object propertyro CucsSolAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.4 |
cucsSolIfDescrCisco UCS sol:If:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.5 |
cucsSolIfIntIdCisco UCS sol:If:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.6 |
cucsSolIfNameCisco UCS sol:If:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.7 |
cucsSolIfSpeedCisco UCS sol:If:speed managed object propertyro CucsSolSpeed (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.8 |
cucsSolIfPolicyLevelCisco UCS sol:If:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.43.2.1.9 |
cucsSolIfPolicyOwnerCisco UCS sol:If:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.10 |
cucsSolPolicyTableCisco UCS sol:Policy managed object table SEQUENCE OF CucsSolPolicyEntry .1.3.6.1.4.1.9.9.719.1.43.3 |
cucsSolPolicyEntryEntry for the cucsSolPolicyTable table. CucsSolPolicyEntry .1.3.6.1.4.1.9.9.719.1.43.3.1 |
cucsSolPolicyInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.1 |
cucsSolPolicyDnCisco UCS sol:Policy:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.2 |
cucsSolPolicyRnCisco UCS sol:Policy:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.3 |
cucsSolPolicyAdminStateCisco UCS sol:Policy:adminState managed object propertyro CucsSolAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.4 |
cucsSolPolicyDescrCisco UCS sol:Policy:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.5 |
cucsSolPolicyIntIdCisco UCS sol:Policy:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.6 |
cucsSolPolicyNameCisco UCS sol:Policy:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.7 |
cucsSolPolicySpeedCisco UCS sol:Policy:speed managed object propertyro CucsSolSpeed (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.8 |
cucsSolPolicyPolicyLevelCisco UCS sol:Policy:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.43.3.1.9 |
cucsSolPolicyPolicyOwnerCisco UCS sol:Policy:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.10 |
cucsSolPolicyPropAclCisco UCS sol:Policy:propAcl managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.43.3.1.11 |
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-ENTITY-VENDORTYPE-OID-MIB maps Cisco-specific hardware component identifiers to the ENTITY-MIB's entPhysicalTable, enabling precise differentiation of physical device types such as line cards, power supplies, and fans within Cisco infrastructure. This mapping ensures that SNMP management systems can accurately correlate physical inventory entries with vendor-specific component definitions for accurate device discovery and monitoring.
The CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB provides SNMP-based monitoring and management of Cisco Unified Computing System (UCS) hardware components, including chassis, blades, fabric interconnects, and power supplies. It exposes critical operational metrics such as device status, port states, temperature readings, fan speeds, and power consumption data for infrastructure health assessment.
The CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB enables SNMP-based monitoring and management of physical and virtual network adapter interfaces, including link status, traffic counters, error statistics, and port configuration parameters, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers.
The CISCO-UNIFIED-COMPUTING-TC-MIB module defines standard textual conventions and data type definitions required for monitoring Cisco Unified Computing System (UCS) hardware components, including server blades, fabric interconnects, and chassis resources. These definitions enable consistent interpretation of specific UCS metrics such as power supply status, fan speeds, thermal readings, and port utilization across SNMP management applications.
The CISCO-UNIFIED-COMPUTING-FABRIC-MIB enables SNMP-based monitoring and management of the Cisco UCS Fabric Interconnects and associated fabric switching infrastructure, exposing metrics for port states, link utilization, error counters, and fabric topology status. It facilitates granular visibility into the physical and logical fabric layers, including uplink/downlink interfaces, VLAN configurations, and fabric failover conditions within the unified computing environment.
The STARENT-MIB module provides SNMP management and monitoring capabilities for Cisco ASR 5000 and ASR 5500 multimedia core platforms, specifically exposing metrics related to 2G/3G/4G and WiFi subscriber sessions, inline service states, and carrier-class high-availability status.