CISCO-UNIFIED-COMPUTING-SOL-MIB
The CISCO-UNIFIED-COMPUTING-SOL-MIB facilitates remote console access and out-of-band management for Cisco Unified Computing System (UCS) servers via the Serial Over LAN (SOL) protocol. It exposes management information for monitoring SOL session states, connection availability, and serial port configuration parameters across UCS blade and rack-mounted chassis.
Imported Objects
Objects
38 total| Object Name |
|---|
cucsSolObjects MODULE-IDENTITY .1.3.6.1.4.1.9.9.719.1.43 |
cucsSolConfigTable SEQUENCE OF CucsSolConfigEntry .1.3.6.1.4.1.9.9.719.1.43.1 |
cucsSolConfigEntry CucsSolConfigEntry .1.3.6.1.4.1.9.9.719.1.43.1.1 |
cucsSolConfigInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.1 |
cucsSolConfigDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.2 |
cucsSolConfigRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.3 |
cucsSolConfigAdminStatero CucsSolAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.4 |
cucsSolConfigDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.5 |
cucsSolConfigIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.6 |
cucsSolConfigNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.7 |
cucsSolConfigSpeedro CucsSolSpeed (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.8 |
cucsSolConfigPolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.43.1.1.9 |
cucsSolConfigPolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.1.1.10 |
cucsSolIfTable SEQUENCE OF CucsSolIfEntry .1.3.6.1.4.1.9.9.719.1.43.2 |
cucsSolIfEntry CucsSolIfEntry .1.3.6.1.4.1.9.9.719.1.43.2.1 |
cucsSolIfInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.1 |
cucsSolIfDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.2 |
cucsSolIfRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.3 |
cucsSolIfAdminStatero CucsSolAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.4 |
cucsSolIfDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.5 |
cucsSolIfIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.6 |
cucsSolIfNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.7 |
cucsSolIfSpeedro CucsSolSpeed (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.8 |
cucsSolIfPolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.43.2.1.9 |
cucsSolIfPolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.2.1.10 |
cucsSolPolicyTable SEQUENCE OF CucsSolPolicyEntry .1.3.6.1.4.1.9.9.719.1.43.3 |
cucsSolPolicyEntry CucsSolPolicyEntry .1.3.6.1.4.1.9.9.719.1.43.3.1 |
cucsSolPolicyInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.1 |
cucsSolPolicyDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.2 |
cucsSolPolicyRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.3 |
cucsSolPolicyAdminStatero CucsSolAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.4 |
cucsSolPolicyDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.5 |
cucsSolPolicyIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.6 |
cucsSolPolicyNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.7 |
cucsSolPolicySpeedro CucsSolSpeed (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.8 |
cucsSolPolicyPolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.43.3.1.9 |
cucsSolPolicyPolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.43.3.1.10 |
cucsSolPolicyPropAclro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.43.3.1.11 |
CISCO-UNIFIED-COMPUTING-SOL-MIB Technical Reference Overview
The CISCO-UNIFIED-COMPUTING-SOL-MIB SNMP MIB module published by Cisco defines 38 managed OID objects, including 31 scalar/column metrics, 3 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.719.1.43. Key tabular structures include cucsSolConfigTable, cucsSolIfTable, cucsSolPolicyTable.
Key OID Definitions in CISCO-UNIFIED-COMPUTING-SOL-MIB
.1.3.6.1.4.1.9.9.719.1.43MIB representation of the Cisco Unified Computing System SOL management information model package
.1.3.6.1.4.1.9.9.719.1.43.1Cisco UCS sol:Config managed object table
.1.3.6.1.4.1.9.9.719.1.43.2Cisco UCS sol:If managed object table
.1.3.6.1.4.1.9.9.719.1.43.3Cisco UCS sol:Policy managed object table
.1.3.6.1.4.1.9.9.719.1.43.1.1Entry for the cucsSolConfigTable table.
.1.3.6.1.4.1.9.9.719.1.43.1.1.1Instance identifier of the managed object.
.1.3.6.1.4.1.9.9.719.1.43.1.1.2Cisco UCS sol:Config:dn managed object property
.1.3.6.1.4.1.9.9.719.1.43.1.1.3Cisco UCS sol:Config:rn managed object property
.1.3.6.1.4.1.9.9.719.1.43.1.1.4Cisco UCS sol:Config:adminState managed object property
.1.3.6.1.4.1.9.9.719.1.43.1.1.5Cisco UCS sol:Config:descr managed object property
.1.3.6.1.4.1.9.9.719.1.43.1.1.6Cisco UCS sol:Config:intId managed object property
.1.3.6.1.4.1.9.9.719.1.43.1.1.7Cisco UCS sol:Config:name managed object property
.1.3.6.1.4.1.9.9.719.1.43.1.1.8Cisco UCS sol:Config:speed managed object property
.1.3.6.1.4.1.9.9.719.1.43.1.1.9Cisco UCS sol:Config:policyLevel managed object property
.1.3.6.1.4.1.9.9.719.1.43.1.1.10Cisco UCS sol:Config:policyOwner managed object property
.1.3.6.1.4.1.9.9.719.1.43.2.1Entry for the cucsSolIfTable table.
.1.3.6.1.4.1.9.9.719.1.43.2.1.1Instance identifier of the managed object.
.1.3.6.1.4.1.9.9.719.1.43.2.1.2Cisco UCS sol:If:dn managed object property
.1.3.6.1.4.1.9.9.719.1.43.2.1.3Cisco UCS sol:If:rn managed object property
.1.3.6.1.4.1.9.9.719.1.43.2.1.4Cisco UCS sol:If:adminState managed object property
.1.3.6.1.4.1.9.9.719.1.43.2.1.5Cisco UCS sol:If:descr managed object property
.1.3.6.1.4.1.9.9.719.1.43.2.1.6Cisco UCS sol:If:intId managed object property
.1.3.6.1.4.1.9.9.719.1.43.2.1.7Cisco UCS sol:If:name managed object property
.1.3.6.1.4.1.9.9.719.1.43.2.1.8Cisco UCS sol:If:speed managed object property
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.