Home/Catalog/CISCO-UNIFIED-COMPUTING-MO-MIB

CISCO-UNIFIED-COMPUTING-MO-MIB

AI MIB Summary

The CISCO-UNIFIED-COMPUTING-MO-MIB provides the management information model for monitoring and configuring Cisco Unified Computing System (UCS) components, including blades, fabric interconnects, and service profiles. It exposes object instances representing the state, configuration, and performance attributes of these hardware and software elements within the UCS infrastructure.

MIB representation of the Cisco Unified Computing System MO management information model package
Main OID:
cucsMoObjects.1.3.6.1.4.1.9.9.719.1.96
81
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

81 total
Object Name
cucsMoObjects
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.719.1.96
cucsMoInvKvTable
SEQUENCE OF CucsMoInvKvEntry
.1.3.6.1.4.1.9.9.719.1.96.1
cucsMoInvKvEntry
CucsMoInvKvEntry
.1.3.6.1.4.1.9.9.719.1.96.1.1
cucsMoInvKvInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.1.1.1
cucsMoInvKvDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.1.1.2
cucsMoInvKvRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.1.1.3
cucsMoInvKvKeyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.1.1.4
cucsMoInvKvOwnerro
CucsMoAnnotationOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.1.1.5
cucsMoInvKvTypero
CucsMoAnnotationType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.1.1.6
cucsMoInvKvValuero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.1.1.7
cucsMoIpV4AddrKvTable
SEQUENCE OF CucsMoIpV4AddrKvEntry
.1.3.6.1.4.1.9.9.719.1.96.2
cucsMoIpV4AddrKvEntry
CucsMoIpV4AddrKvEntry
.1.3.6.1.4.1.9.9.719.1.96.2.1
cucsMoIpV4AddrKvInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.1
cucsMoIpV4AddrKvDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.2
cucsMoIpV4AddrKvRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.3
cucsMoIpV4AddrKvAddrro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.4
cucsMoIpV4AddrKvDefGwro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.5
cucsMoIpV4AddrKvKeyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.6
cucsMoIpV4AddrKvOperPoolNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.7
cucsMoIpV4AddrKvOwnerro
CucsMoAnnotationOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.8
cucsMoIpV4AddrKvPoolNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.9
cucsMoIpV4AddrKvPrimDnsro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.10
cucsMoIpV4AddrKvSecDnsro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.11
cucsMoIpV4AddrKvSubnetro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.12
cucsMoIpV4AddrKvTargetro
CucsMoAnnotationTarget (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.13
cucsMoIpV4AddrKvTypero
CucsMoIpV4AddrKvType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.14
cucsMoIpV4AddrKvValuero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.2.1.15
cucsMoIpV6AddrKvTable
SEQUENCE OF CucsMoIpV6AddrKvEntry
.1.3.6.1.4.1.9.9.719.1.96.3
cucsMoIpV6AddrKvEntry
CucsMoIpV6AddrKvEntry
.1.3.6.1.4.1.9.9.719.1.96.3.1
cucsMoIpV6AddrKvInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.1
cucsMoIpV6AddrKvDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.2
cucsMoIpV6AddrKvRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.3
cucsMoIpV6AddrKvAddrro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.4
cucsMoIpV6AddrKvDefGwro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.5
cucsMoIpV6AddrKvKeyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.6
cucsMoIpV6AddrKvOperPoolNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.7
cucsMoIpV6AddrKvOwnerro
CucsMoAnnotationOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.8
cucsMoIpV6AddrKvPoolNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.9
cucsMoIpV6AddrKvPrefixro
Gauge32
.1.3.6.1.4.1.9.9.719.1.96.3.1.10
cucsMoIpV6AddrKvPrimDnsro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.11
cucsMoIpV6AddrKvSecDnsro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.12
cucsMoIpV6AddrKvTargetro
CucsMoAnnotationTarget (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.13
cucsMoIpV6AddrKvTypero
CucsMoIpV6AddrKvType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.14
cucsMoIpV6AddrKvValuero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.3.1.15
cucsMoKvTable
SEQUENCE OF CucsMoKvEntry
.1.3.6.1.4.1.9.9.719.1.96.4
cucsMoKvEntry
CucsMoKvEntry
.1.3.6.1.4.1.9.9.719.1.96.4.1
cucsMoKvInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.4.1.1
cucsMoKvDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.4.1.2
cucsMoKvRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.4.1.3
cucsMoKvKeyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.4.1.4
cucsMoKvOverridero
CucsMoAnnotationOverride (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.4.1.5
cucsMoKvOwnerro
CucsMoAnnotationOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.4.1.6
cucsMoKvTargetro
CucsMoAnnotationTarget (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.4.1.7
cucsMoKvTypero
CucsMoKvType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.4.1.8
cucsMoKvValuero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.4.1.9
cucsMoKvCfgHolderTable
SEQUENCE OF CucsMoKvCfgHolderEntry
.1.3.6.1.4.1.9.9.719.1.96.5
cucsMoKvCfgHolderEntry
CucsMoKvCfgHolderEntry
.1.3.6.1.4.1.9.9.719.1.96.5.1
cucsMoKvCfgHolderInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.5.1.1
cucsMoKvCfgHolderDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.5.1.2
cucsMoKvCfgHolderRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.5.1.3
cucsMoKvCfgHolderFileTxAdminStatero
CucsMoFileTxAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.5.1.4
cucsMoKvCfgHolderOperStatero
CucsMoAnnotationOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.5.1.5
cucsMoKvInvHolderTable
SEQUENCE OF CucsMoKvInvHolderEntry
.1.3.6.1.4.1.9.9.719.1.96.6
cucsMoKvInvHolderEntry
CucsMoKvInvHolderEntry
.1.3.6.1.4.1.9.9.719.1.96.6.1
cucsMoKvInvHolderInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.6.1.1
cucsMoKvInvHolderDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.6.1.2
cucsMoKvInvHolderRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.6.1.3
cucsMoKvInvHolderEndpointro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.6.1.4
cucsMoKvInvHolderLastUpdatero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.96.6.1.5
cucsMoVnicKvTable
SEQUENCE OF CucsMoVnicKvEntry
.1.3.6.1.4.1.9.9.719.1.96.7
cucsMoVnicKvEntry
CucsMoVnicKvEntry
.1.3.6.1.4.1.9.9.719.1.96.7.1
cucsMoVnicKvInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.7.1.1
cucsMoVnicKvDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.96.7.1.2
cucsMoVnicKvRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.7.1.3
cucsMoVnicKvKeyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.7.1.4
cucsMoVnicKvOwnerro
CucsMoAnnotationOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.7.1.5
cucsMoVnicKvTargetro
CucsMoAnnotationTarget (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.7.1.6
cucsMoVnicKvTypero
CucsMoVnicKvType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.96.7.1.7
cucsMoVnicKvValuero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.7.1.8
cucsMoVnicKvVnicEtherDnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.7.1.9
cucsMoVnicKvVnicNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.96.7.1.10

CISCO-UNIFIED-COMPUTING-MO-MIB Technical Reference Overview

The CISCO-UNIFIED-COMPUTING-MO-MIB SNMP MIB module published by Cisco defines 81 managed OID objects, including 66 scalar/column metrics, 7 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.719.1.96. Key tabular structures include cucsMoInvKvTable, cucsMoIpV4AddrKvTable, cucsMoIpV6AddrKvTable, cucsMoKvTable, cucsMoKvCfgHolderTable, cucsMoKvInvHolderTable.

Key OID Definitions in CISCO-UNIFIED-COMPUTING-MO-MIB

cucsMoObjectsMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.719.1.96

MIB representation of the Cisco Unified Computing System MO management information model package

cucsMoInvKvTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.96.1

Cisco UCS mo:InvKv managed object table

cucsMoIpV4AddrKvTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.96.2

Cisco UCS mo:IpV4AddrKv managed object table

cucsMoIpV6AddrKvTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.96.3

Cisco UCS mo:IpV6AddrKv managed object table

cucsMoKvTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.96.4

Cisco UCS mo:Kv managed object table

cucsMoKvCfgHolderTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.96.5

Cisco UCS mo:KvCfgHolder managed object table

cucsMoKvInvHolderTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.96.6

Cisco UCS mo:KvInvHolder managed object table

cucsMoVnicKvTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.96.7

Cisco UCS mo:VnicKv managed object table

cucsMoInvKvEntryCucsMoInvKvEntrynot-accessible
.1.3.6.1.4.1.9.9.719.1.96.1.1

Entry for the cucsMoInvKvTable table.

cucsMoInvKvInstanceIdCucsManagedObjectIdnot-accessible
.1.3.6.1.4.1.9.9.719.1.96.1.1.1

Instance identifier of the managed object.

cucsMoInvKvDnCucsManagedObjectDnread-only
.1.3.6.1.4.1.9.9.719.1.96.1.1.2

Cisco UCS mo:InvKv:dn managed object property

cucsMoInvKvRnSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.96.1.1.3

Cisco UCS mo:InvKv:rn managed object property

cucsMoInvKvKeySnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.96.1.1.4

Cisco UCS mo:InvKv:key managed object property

cucsMoInvKvOwnerCucsMoAnnotationOwnerread-only
.1.3.6.1.4.1.9.9.719.1.96.1.1.5

Cisco UCS mo:InvKv:owner managed object property

cucsMoInvKvTypeCucsMoAnnotationTyperead-only
.1.3.6.1.4.1.9.9.719.1.96.1.1.6

Cisco UCS mo:InvKv:type managed object property

cucsMoInvKvValueSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.96.1.1.7

Cisco UCS mo:InvKv:value managed object property

cucsMoIpV4AddrKvEntryCucsMoIpV4AddrKvEntrynot-accessible
.1.3.6.1.4.1.9.9.719.1.96.2.1

Entry for the cucsMoIpV4AddrKvTable table.

cucsMoIpV4AddrKvInstanceIdCucsManagedObjectIdnot-accessible
.1.3.6.1.4.1.9.9.719.1.96.2.1.1

Instance identifier of the managed object.

cucsMoIpV4AddrKvDnCucsManagedObjectDnread-only
.1.3.6.1.4.1.9.9.719.1.96.2.1.2

Cisco UCS mo:IpV4AddrKv:dn managed object property

cucsMoIpV4AddrKvRnSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.96.2.1.3

Cisco UCS mo:IpV4AddrKv:rn managed object property

cucsMoIpV4AddrKvAddrInetAddressIPv4read-only
.1.3.6.1.4.1.9.9.719.1.96.2.1.4

Cisco UCS mo:IpV4AddrKv:addr managed object property

cucsMoIpV4AddrKvDefGwInetAddressIPv4read-only
.1.3.6.1.4.1.9.9.719.1.96.2.1.5

Cisco UCS mo:IpV4AddrKv:defGw managed object property

cucsMoIpV4AddrKvKeySnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.96.2.1.6

Cisco UCS mo:IpV4AddrKv:key managed object property

cucsMoIpV4AddrKvOperPoolNameSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.96.2.1.7

Cisco UCS mo:IpV4AddrKv:operPoolName managed object property

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→