CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB
The CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB module provides SNMP access to monitor and manage logical storage resources, including virtual disk configurations, storage pool states, and LUN mappings within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
Imported Objects
Objects
238 total| Object Name |
|---|
cucsLstorageObjects MODULE-IDENTITY .1.3.6.1.4.1.9.9.719.1.79 |
cucsLstorageDasScsiLunTable SEQUENCE OF CucsLstorageDasScsiLunEntry .1.3.6.1.4.1.9.9.719.1.79.14 |
cucsLstorageDasScsiLunEntry CucsLstorageDasScsiLunEntry .1.3.6.1.4.1.9.9.719.1.79.14.1 |
cucsLstorageDasScsiLunInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.1 |
cucsLstorageDasScsiLunDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.2 |
cucsLstorageDasScsiLunRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.3 |
cucsLstorageDasScsiLunAdminStatero CucsLstorageAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.4 |
cucsLstorageDasScsiLunAutoDeployro CucsLstorageAutoDeploy (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.5 |
cucsLstorageDasScsiLunBootDevro CucsLstorageBootDevice (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.6 |
cucsLstorageDasScsiLunConfigQualifierro CucsLstorageConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.7 |
cucsLstorageDasScsiLunConfigStatero CucsLstorageConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.8 |
cucsLstorageDasScsiLunExpandToAvailro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.79.14.1.9 |
cucsLstorageDasScsiLunLocalDiskPolicyNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.10 |
cucsLstorageDasScsiLunLunDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.11 |
cucsLstorageDasScsiLunLunMapTypero CucsLstorageLunMapType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.12 |
cucsLstorageDasScsiLunNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.13 |
cucsLstorageDasScsiLunOperLocalDiskPolicyNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.14 |
cucsLstorageDasScsiLunOperStatero CucsStorageUnitOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.15 |
cucsLstorageDasScsiLunOrderro Gauge32 .1.3.6.1.4.1.9.9.719.1.79.14.1.16 |
cucsLstorageDasScsiLunSizero Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.79.14.1.17 |
cucsLstorageDasScsiLunStorageClassro CucsLstorageDasScsiLunStorageClass (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.14.1.18 |
cucsLstorageDasScsiLunDeferredNamingro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.79.14.1.19 |
cucsLstorageDasScsiLunFractionalSizero Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.79.14.1.21 |
cucsLstorageDiskGroupConfigDefTable SEQUENCE OF CucsLstorageDiskGroupConfigDefEntry .1.3.6.1.4.1.9.9.719.1.79.15 |
cucsLstorageDiskGroupConfigDefEntry CucsLstorageDiskGroupConfigDefEntry .1.3.6.1.4.1.9.9.719.1.79.15.1 |
cucsLstorageDiskGroupConfigDefInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.15.1.1 |
cucsLstorageDiskGroupConfigDefDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.15.1.2 |
cucsLstorageDiskGroupConfigDefRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.15.1.3 |
cucsLstorageDiskGroupConfigDefDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.15.1.4 |
cucsLstorageDiskGroupConfigDefIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.15.1.5 |
cucsLstorageDiskGroupConfigDefNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.15.1.6 |
cucsLstorageDiskGroupConfigDefPolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.79.15.1.7 |
cucsLstorageDiskGroupConfigDefPolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.15.1.8 |
cucsLstorageDiskGroupConfigDefRaidLevelro CucsStorageLunType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.15.1.9 |
cucsLstorageDiskGroupConfigPolicyTable SEQUENCE OF CucsLstorageDiskGroupConfigPolicyEntry .1.3.6.1.4.1.9.9.719.1.79.16 |
cucsLstorageDiskGroupConfigPolicyEntry CucsLstorageDiskGroupConfigPolicyEntry .1.3.6.1.4.1.9.9.719.1.79.16.1 |
cucsLstorageDiskGroupConfigPolicyInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.16.1.1 |
cucsLstorageDiskGroupConfigPolicyDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.16.1.2 |
cucsLstorageDiskGroupConfigPolicyRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.16.1.3 |
cucsLstorageDiskGroupConfigPolicyDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.16.1.4 |
cucsLstorageDiskGroupConfigPolicyIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.16.1.5 |
cucsLstorageDiskGroupConfigPolicyNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.16.1.6 |
cucsLstorageDiskGroupConfigPolicyPolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.79.16.1.7 |
cucsLstorageDiskGroupConfigPolicyPolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.16.1.8 |
cucsLstorageDiskGroupConfigPolicyRaidLevelro CucsStorageLunType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.16.1.9 |
cucsLstorageDiskGroupQualifierTable SEQUENCE OF CucsLstorageDiskGroupQualifierEntry .1.3.6.1.4.1.9.9.719.1.79.17 |
cucsLstorageDiskGroupQualifierEntry CucsLstorageDiskGroupQualifierEntry .1.3.6.1.4.1.9.9.719.1.79.17.1 |
cucsLstorageDiskGroupQualifierInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.17.1.1 |
cucsLstorageDiskGroupQualifierDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.17.1.2 |
cucsLstorageDiskGroupQualifierRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.17.1.3 |
cucsLstorageDiskGroupQualifierDriveTypero CucsStorageTechnologyConfig (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.17.1.4 |
cucsLstorageDiskGroupQualifierMinDriveSizero Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.79.17.1.5 |
cucsLstorageDiskGroupQualifierNumDedHotSparesro Gauge32 .1.3.6.1.4.1.9.9.719.1.79.17.1.6 |
cucsLstorageDiskGroupQualifierNumDrivesro Gauge32 .1.3.6.1.4.1.9.9.719.1.79.17.1.7 |
cucsLstorageDiskGroupQualifierNumGlobHotSparesro Gauge32 .1.3.6.1.4.1.9.9.719.1.79.17.1.8 |
cucsLstorageDiskGroupQualifierUseRemainingDisksro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.79.17.1.9 |
cucsLstorageDiskGroupQualifierUseJbodDisksro CucsStoragePDriveConfig (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.17.1.10 |
cucsLstorageLocalDiskConfigRefTable SEQUENCE OF CucsLstorageLocalDiskConfigRefEntry .1.3.6.1.4.1.9.9.719.1.79.21 |
cucsLstorageLocalDiskConfigRefEntry CucsLstorageLocalDiskConfigRefEntry .1.3.6.1.4.1.9.9.719.1.79.21.1 |
cucsLstorageLocalDiskConfigRefInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.21.1.1 |
cucsLstorageLocalDiskConfigRefDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.21.1.2 |
cucsLstorageLocalDiskConfigRefRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.21.1.3 |
cucsLstorageLocalDiskConfigRefRolero CucsStorageDiskRole (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.21.1.4 |
cucsLstorageLocalDiskConfigRefSlotNumro Gauge32 .1.3.6.1.4.1.9.9.719.1.79.21.1.5 |
cucsLstorageLocalDiskConfigRefSpanIdro Gauge32 .1.3.6.1.4.1.9.9.719.1.79.21.1.6 |
cucsLstorageLocalDiskRefTable SEQUENCE OF CucsLstorageLocalDiskRefEntry .1.3.6.1.4.1.9.9.719.1.79.22 |
cucsLstorageLocalDiskRefEntry CucsLstorageLocalDiskRefEntry .1.3.6.1.4.1.9.9.719.1.79.22.1 |
cucsLstorageLocalDiskRefInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.22.1.1 |
cucsLstorageLocalDiskRefDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.22.1.2 |
cucsLstorageLocalDiskRefRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.22.1.3 |
cucsLstorageLocalDiskRefEnclosureIdro Gauge32 .1.3.6.1.4.1.9.9.719.1.79.22.1.4 |
cucsLstorageLocalDiskRefSlotIdro Gauge32 .1.3.6.1.4.1.9.9.719.1.79.22.1.5 |
cucsLstorageProfileTable SEQUENCE OF CucsLstorageProfileEntry .1.3.6.1.4.1.9.9.719.1.79.37 |
cucsLstorageProfileEntry CucsLstorageProfileEntry .1.3.6.1.4.1.9.9.719.1.79.37.1 |
cucsLstorageProfileInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.37.1.1 |
cucsLstorageProfileDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.37.1.2 |
cucsLstorageProfileRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.37.1.3 |
cucsLstorageProfileAssignedToDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.37.1.4 |
cucsLstorageProfileAvailabilityro CucsLstorageAvailability (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.37.1.5 |
cucsLstorageProfileDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.37.1.6 |
cucsLstorageProfileIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.37.1.7 |
cucsLstorageProfileNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.37.1.8 |
cucsLstorageProfilePolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.79.37.1.9 |
cucsLstorageProfilePolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.37.1.10 |
cucsLstorageProfileBindingTable SEQUENCE OF CucsLstorageProfileBindingEntry .1.3.6.1.4.1.9.9.719.1.79.38 |
cucsLstorageProfileBindingEntry CucsLstorageProfileBindingEntry .1.3.6.1.4.1.9.9.719.1.79.38.1 |
cucsLstorageProfileBindingInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.38.1.1 |
cucsLstorageProfileBindingDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.38.1.2 |
cucsLstorageProfileBindingRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.38.1.3 |
cucsLstorageProfileBindingAssignedToDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.38.1.4 |
cucsLstorageProfileBindingIssuesro CucsLsConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.79.38.1.5 |
cucsLstorageProfileBindingNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.38.1.6 |
cucsLstorageProfileBindingOperStorageProfileNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.38.1.7 |
cucsLstorageProfileBindingStorageProfileNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.38.1.8 |
cucsLstorageProfileDefTable SEQUENCE OF CucsLstorageProfileDefEntry .1.3.6.1.4.1.9.9.719.1.79.39 |
cucsLstorageProfileDefEntry CucsLstorageProfileDefEntry .1.3.6.1.4.1.9.9.719.1.79.39.1 |
cucsLstorageProfileDefInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.39.1.1 |
cucsLstorageProfileDefDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.79.39.1.2 |
cucsLstorageProfileDefRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.39.1.3 |
cucsLstorageProfileDefAssignedToDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.79.39.1.4 |
CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB Technical Reference Overview
The CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB SNMP MIB module published by Cisco defines 238 managed OID objects, including 189 scalar/column metrics, 24 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.719.1.79. Key tabular structures include cucsLstorageControllerDefTable, cucsLstorageControllerModeConfigTable, cucsLstorageControllerQualifierTable, cucsLstorageControllerRefTable, cucsLstorageDasScsiLunTable, cucsLstorageDiskGroupConfigDefTable.
Key OID Definitions in CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB
.1.3.6.1.4.1.9.9.719.1.79MIB representation of the Cisco Unified Computing System LSTORAGE management information model package
.1.3.6.1.4.1.9.9.719.1.79.52Cisco UCS lstorage:ControllerDef managed object table
.1.3.6.1.4.1.9.9.719.1.79.53Cisco UCS lstorage:ControllerModeConfig managed object table
.1.3.6.1.4.1.9.9.719.1.79.54Cisco UCS lstorage:ControllerQualifier managed object table
.1.3.6.1.4.1.9.9.719.1.79.57Cisco UCS lstorage:ControllerRef managed object table
.1.3.6.1.4.1.9.9.719.1.79.14Cisco UCS lstorage:DasScsiLun managed object table
.1.3.6.1.4.1.9.9.719.1.79.15Cisco UCS lstorage:DiskGroupConfigDef managed object table
.1.3.6.1.4.1.9.9.719.1.79.16Cisco UCS lstorage:DiskGroupConfigPolicy managed object table
.1.3.6.1.4.1.9.9.719.1.79.17Cisco UCS lstorage:DiskGroupQualifier managed object table
.1.3.6.1.4.1.9.9.719.1.79.58Cisco UCS lstorage:DiskSlot managed object table
.1.3.6.1.4.1.9.9.719.1.79.59Cisco UCS lstorage:DiskZoningConfigDef managed object table
.1.3.6.1.4.1.9.9.719.1.79.60Cisco UCS lstorage:DiskZoningPolicy managed object table
.1.3.6.1.4.1.9.9.719.1.79.61Cisco UCS lstorage:DriveSecurity managed object table
.1.3.6.1.4.1.9.9.719.1.79.62Cisco UCS lstorage:Local managed object table
.1.3.6.1.4.1.9.9.719.1.79.63Cisco UCS lstorage:LocalDef managed object table
.1.3.6.1.4.1.9.9.719.1.79.21Cisco UCS lstorage:LocalDiskConfigRef managed object table
.1.3.6.1.4.1.9.9.719.1.79.22Cisco UCS lstorage:LocalDiskRef managed object table
.1.3.6.1.4.1.9.9.719.1.79.64Cisco UCS lstorage:Login managed object table
.1.3.6.1.4.1.9.9.719.1.79.37Cisco UCS lstorage:Profile managed object table
.1.3.6.1.4.1.9.9.719.1.79.38Cisco UCS lstorage:ProfileBinding managed object table
.1.3.6.1.4.1.9.9.719.1.79.39Cisco UCS lstorage:ProfileDef managed object table
.1.3.6.1.4.1.9.9.719.1.79.65Cisco UCS lstorage:Remote managed object table
.1.3.6.1.4.1.9.9.719.1.79.66Cisco UCS lstorage:RemoteDef managed object table
.1.3.6.1.4.1.9.9.719.1.79.67Cisco UCS lstorage:Security managed object table
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.