Home/Catalog/CISCO-UNIFIED-COMPUTING-LSMAINT-MIB

CISCO-UNIFIED-COMPUTING-LSMAINT-MIB

AI MIB Summary

The CISCO-UNIFIED-COMPUTING-LSMAINT-MIB facilitates SNMP-based monitoring and maintenance operations for Cisco UCS Local Service Modules (LSM), specifically tracking service state transitions, fault conditions, and operational health metrics within the UCS fabric interconnect environment.

MIB representation of the Cisco Unified Computing System LSMAINT management information model package
Main OID:
cucsLsmaintObjects.1.3.6.1.4.1.9.9.719.1.28
50
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

50 total
Object Name
cucsLsmaintObjects
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.719.1.28
cucsLsmaintAckTable
SEQUENCE OF CucsLsmaintAckEntry
.1.3.6.1.4.1.9.9.719.1.28.1
cucsLsmaintAckEntry
CucsLsmaintAckEntry
.1.3.6.1.4.1.9.9.719.1.28.1.1
cucsLsmaintAckInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.1
cucsLsmaintAckDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.2
cucsLsmaintAckRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.3
cucsLsmaintAckAckedro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.28.1.1.4
cucsLsmaintAckAckedByro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.5
cucsLsmaintAckAdminStatero
CucsTrigAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.6
cucsLsmaintAckChangeByro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.7
cucsLsmaintAckChangesro
CucsLsmaintAckChanges (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.8
cucsLsmaintAckDescrro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.9
cucsLsmaintAckDisrro
CucsLsmaintAckDisr (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.10
cucsLsmaintAckIntIdro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.11
cucsLsmaintAckModifiedro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.28.1.1.12
cucsLsmaintAckNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.13
cucsLsmaintAckOperStatero
CucsTrigAckOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.14
cucsLsmaintAckSchedulerro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.15
cucsLsmaintAckChangeDetailsro
CucsLsmaintAckChangeDetails (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.16
cucsLsmaintAckChangeModero
CucsLsmaintChangeMode (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.17
cucsLsmaintAckConfigIssuesro
CucsLsConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.18
cucsLsmaintAckOldPnDnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.19
cucsLsmaintAckDeploymentModero
CucsTrigAckMode (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.20
cucsLsmaintAckAutoDeletero
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.28.1.1.21
cucsLsmaintAckIgnoreCapro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.28.1.1.22
cucsLsmaintAckOperSchedulerro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.23
cucsLsmaintAckPolicyLevelro
Gauge32
.1.3.6.1.4.1.9.9.719.1.28.1.1.24
cucsLsmaintAckPolicyOwnerro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.25
cucsLsmaintAckPrevOperStatero
CucsTrigAckPrevOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.26
cucsLsmaintAckPropAclro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.28.1.1.27
cucsLsmaintAckTriggerConfigStatero
CucsTrigTrigState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.28
cucsLsmaintAckAnalyzeImpactChangeDetailsro
CucsTrigAckChangeDetails (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.29
cucsLsmaintAckAnalyzeImpactChangesro
CucsTrigAckChanges (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.30
cucsLsmaintAckCheckApplyConfigCookiero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.1.1.31
cucsLsmaintMaintPolicyTable
SEQUENCE OF CucsLsmaintMaintPolicyEntry
.1.3.6.1.4.1.9.9.719.1.28.2
cucsLsmaintMaintPolicyEntry
CucsLsmaintMaintPolicyEntry
.1.3.6.1.4.1.9.9.719.1.28.2.1
cucsLsmaintMaintPolicyInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.28.2.1.1
cucsLsmaintMaintPolicyDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.28.2.1.2
cucsLsmaintMaintPolicyRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.2.1.3
cucsLsmaintMaintPolicyUptimeDisrro
CucsTrigAckMode (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.2.1.4
cucsLsmaintMaintPolicySchedNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.2.1.5
cucsLsmaintMaintPolicyDescrro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.2.1.6
cucsLsmaintMaintPolicyNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.2.1.7
cucsLsmaintMaintPolicyIntIdro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.2.1.8
cucsLsmaintMaintPolicyOperSchedNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.28.2.1.9
cucsLsmaintMaintPolicyPolicyLevelro
Gauge32
.1.3.6.1.4.1.9.9.719.1.28.2.1.10
cucsLsmaintMaintPolicyPolicyOwnerro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.2.1.11
cucsLsmaintMaintPolicyTriggerConfigro
CucsTrigTrigger (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.2.1.12
cucsLsmaintMaintPolicySoftShutdownTimerro
TimeIntervalSec (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.28.2.1.13
cucsLsmaintMaintPolicyDataDisrro
CucsTrigStorageAckMode (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.28.2.1.14

CISCO-UNIFIED-COMPUTING-LSMAINT-MIB Technical Reference Overview

The CISCO-UNIFIED-COMPUTING-LSMAINT-MIB SNMP MIB module published by Cisco defines 50 managed OID objects, including 45 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.719.1.28. Key tabular structures include cucsLsmaintAckTable, cucsLsmaintMaintPolicyTable.

Key OID Definitions in CISCO-UNIFIED-COMPUTING-LSMAINT-MIB

cucsLsmaintObjectsMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.719.1.28

MIB representation of the Cisco Unified Computing System LSMAINT management information model package

cucsLsmaintAckTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.28.1

Cisco UCS lsmaint:Ack managed object table

cucsLsmaintMaintPolicyTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.28.2

Cisco UCS lsmaint:MaintPolicy managed object table

cucsLsmaintAckEntryCucsLsmaintAckEntrynot-accessible
.1.3.6.1.4.1.9.9.719.1.28.1.1

Entry for the cucsLsmaintAckTable table.

cucsLsmaintAckInstanceIdCucsManagedObjectIdnot-accessible
.1.3.6.1.4.1.9.9.719.1.28.1.1.1

Instance identifier of the managed object.

cucsLsmaintAckDnCucsManagedObjectDnread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.2

Cisco UCS lsmaint:Ack:dn managed object property

cucsLsmaintAckRnSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.3

Cisco UCS lsmaint:Ack:rn managed object property

cucsLsmaintAckAckedDateAndTimeread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.4

Cisco UCS lsmaint:Ack:acked managed object property

cucsLsmaintAckAckedBySnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.5

Cisco UCS lsmaint:Ack:ackedBy managed object property

cucsLsmaintAckAdminStateCucsTrigAdminStateread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.6

Cisco UCS lsmaint:Ack:adminState managed object property

cucsLsmaintAckChangeBySnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.7

Cisco UCS lsmaint:Ack:changeBy managed object property

cucsLsmaintAckChangesCucsLsmaintAckChangesread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.8

Cisco UCS lsmaint:Ack:changes managed object property

cucsLsmaintAckDescrSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.9

Cisco UCS lsmaint:Ack:descr managed object property

cucsLsmaintAckDisrCucsLsmaintAckDisrread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.10

Cisco UCS lsmaint:Ack:disr managed object property

cucsLsmaintAckIntIdSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.11

Cisco UCS lsmaint:Ack:intId managed object property

cucsLsmaintAckModifiedDateAndTimeread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.12

Cisco UCS lsmaint:Ack:modified managed object property

cucsLsmaintAckNameSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.13

Cisco UCS lsmaint:Ack:name managed object property

cucsLsmaintAckOperStateCucsTrigAckOperStateread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.14

Cisco UCS lsmaint:Ack:operState managed object property

cucsLsmaintAckSchedulerSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.15

Cisco UCS lsmaint:Ack:scheduler managed object property

cucsLsmaintAckChangeDetailsCucsLsmaintAckChangeDetailsread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.16

Cisco UCS lsmaint:Ack:changeDetails managed object property

cucsLsmaintAckChangeModeCucsLsmaintChangeModeread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.17

Cisco UCS lsmaint:Ack:changeMode managed object property

cucsLsmaintAckConfigIssuesCucsLsConfigIssuesread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.18

Cisco UCS lsmaint:Ack:configIssues managed object property

cucsLsmaintAckOldPnDnSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.19

Cisco UCS lsmaint:Ack:oldPnDn managed object property

cucsLsmaintAckDeploymentModeCucsTrigAckModeread-only
.1.3.6.1.4.1.9.9.719.1.28.1.1.20

Cisco UCS lsmaint:Ack:deploymentMode managed object property

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→