CISCO-UNIFIED-COMPUTING-IPPOOL-MIB
The CISCO-UNIFIED-COMPUTING-IPPOOL-MIB enables SNMP-based monitoring and configuration of IP address pool objects, including pool definitions, address ranges, and utilization statistics, within the Cisco Unified Computing System (UCS) fabric interconnects. This module facilitates the management of dynamic IP assignment resources for UCS blade servers and virtual interfaces by exposing specific pool capacity, lease status, and allocation counters.
Imported Objects
Objects
107 total| Object Name |
|---|
cucsIppoolObjectsMIB representation of the Cisco Unified Computing System
IPPOOL management information model package MODULE-IDENTITY .1.3.6.1.4.1.9.9.719.1.24 |
cucsIppoolAddrTableCisco UCS ippool:Addr managed object table SEQUENCE OF CucsIppoolAddrEntry .1.3.6.1.4.1.9.9.719.1.24.1 |
cucsIppoolAddrEntryEntry for the cucsIppoolAddrTable table. CucsIppoolAddrEntry .1.3.6.1.4.1.9.9.719.1.24.1.1 |
cucsIppoolAddrInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.1.1.1 |
cucsIppoolAddrDnCisco UCS ippool:Addr:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.1.1.2 |
cucsIppoolAddrRnCisco UCS ippool:Addr:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.1.1.3 |
cucsIppoolAddrAssignedCisco UCS ippool:Addr:assigned managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.24.1.1.4 |
cucsIppoolAddrAssignedToDnCisco UCS ippool:Addr:assignedToDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.1.1.5 |
cucsIppoolAddrIdCisco UCS ippool:Addr:id managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.1.1.6 |
cucsIppoolAddrOwnerCisco UCS ippool:Addr:owner managed object propertyro CucsPoolElementOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.24.1.1.7 |
cucsIppoolAddrGlobalAssignedCntCisco UCS ippool:Addr:globalAssignedCnt managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.1.1.8 |
cucsIppoolAddrGlobalDefinedCntCisco UCS ippool:Addr:globalDefinedCnt managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.1.1.9 |
cucsIppoolBlockTableCisco UCS ippool:Block managed object table SEQUENCE OF CucsIppoolBlockEntry .1.3.6.1.4.1.9.9.719.1.24.2 |
cucsIppoolBlockEntryEntry for the cucsIppoolBlockTable table. CucsIppoolBlockEntry .1.3.6.1.4.1.9.9.719.1.24.2.1 |
cucsIppoolBlockInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.2.1.1 |
cucsIppoolBlockDnCisco UCS ippool:Block:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.2.1.2 |
cucsIppoolBlockRnCisco UCS ippool:Block:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.2.1.3 |
cucsIppoolBlockDefGwCisco UCS ippool:Block:defGw managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.2.1.4 |
cucsIppoolBlockFromCisco UCS ippool:Block:from managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.2.1.5 |
cucsIppoolBlockSubnetCisco UCS ippool:Block:subnet managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.2.1.6 |
cucsIppoolBlockToCisco UCS ippool:Block:to managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.2.1.7 |
cucsIppoolBlockPrimDnsCisco UCS ippool:Block:primDns managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.2.1.8 |
cucsIppoolBlockSecDnsCisco UCS ippool:Block:secDns managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.2.1.9 |
cucsIppoolPoolTableCisco UCS ippool:Pool managed object table SEQUENCE OF CucsIppoolPoolEntry .1.3.6.1.4.1.9.9.719.1.24.3 |
cucsIppoolPoolEntryEntry for the cucsIppoolPoolTable table. CucsIppoolPoolEntry .1.3.6.1.4.1.9.9.719.1.24.3.1 |
cucsIppoolPoolInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.3.1.1 |
cucsIppoolPoolDnCisco UCS ippool:Pool:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.3.1.2 |
cucsIppoolPoolRnCisco UCS ippool:Pool:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.3.1.3 |
cucsIppoolPoolAssignedCisco UCS ippool:Pool:assigned managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.3.1.4 |
cucsIppoolPoolDescrCisco UCS ippool:Pool:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.3.1.5 |
cucsIppoolPoolIntIdCisco UCS ippool:Pool:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.3.1.6 |
cucsIppoolPoolNameCisco UCS ippool:Pool:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.3.1.7 |
cucsIppoolPoolSizeCisco UCS ippool:Pool:size managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.3.1.8 |
cucsIppoolPoolAssignmentOrderCisco UCS ippool:Pool:assignmentOrder managed object propertyro CucsIppoolPoolAssignmentOrder (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.24.3.1.9 |
cucsIppoolPoolPolicyLevelCisco UCS ippool:Pool:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.3.1.10 |
cucsIppoolPoolPolicyOwnerCisco UCS ippool:Pool:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.24.3.1.11 |
cucsIppoolPoolExtManagedCisco UCS ippool:Pool:extManaged managed object propertyro CucsIppoolManagementMode (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.24.3.1.12 |
cucsIppoolPoolGuidCisco UCS ippool:Pool:guid managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.3.1.13 |
cucsIppoolPoolIsNetBIOSEnabledCisco UCS ippool:Pool:isNetBIOSEnabled managed object propertyro CucsIppoolNetBIOSMode (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.24.3.1.14 |
cucsIppoolPoolSupportsDHCPCisco UCS ippool:Pool:supportsDHCP managed object propertyro CucsIppoolDHCPMode (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.24.3.1.15 |
cucsIppoolPoolV4AssignedCisco UCS ippool:Pool:v4Assigned managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.3.1.16 |
cucsIppoolPoolV4SizeCisco UCS ippool:Pool:v4Size managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.3.1.17 |
cucsIppoolPoolV6AssignedCisco UCS ippool:Pool:v6Assigned managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.3.1.18 |
cucsIppoolPoolV6SizeCisco UCS ippool:Pool:v6Size managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.3.1.19 |
cucsIppoolPoolPropAclCisco UCS ippool:Pool:propAcl managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.24.3.1.20 |
cucsIppoolPoolableTableCisco UCS ippool:Poolable managed object table SEQUENCE OF CucsIppoolPoolableEntry .1.3.6.1.4.1.9.9.719.1.24.4 |
cucsIppoolPoolableEntryEntry for the cucsIppoolPoolableTable table. CucsIppoolPoolableEntry .1.3.6.1.4.1.9.9.719.1.24.4.1 |
cucsIppoolPoolableInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.4.1.1 |
cucsIppoolPoolableDnCisco UCS ippool:Poolable:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.4.1.2 |
cucsIppoolPoolableRnCisco UCS ippool:Poolable:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.4.1.3 |
cucsIppoolPoolableIdCisco UCS ippool:Poolable:id managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.24.4.1.4 |
cucsIppoolPoolablePoolDnCisco UCS ippool:Poolable:poolDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.4.1.5 |
cucsIppoolPooledTableCisco UCS ippool:Pooled managed object table SEQUENCE OF CucsIppoolPooledEntry .1.3.6.1.4.1.9.9.719.1.24.5 |
cucsIppoolPooledEntryEntry for the cucsIppoolPooledTable table. CucsIppoolPooledEntry .1.3.6.1.4.1.9.9.719.1.24.5.1 |
cucsIppoolPooledInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.5.1.1 |
cucsIppoolPooledDnCisco UCS ippool:Pooled:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.5.1.2 |
cucsIppoolPooledRnCisco UCS ippool:Pooled:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.5.1.3 |
cucsIppoolPooledAssignedCisco UCS ippool:Pooled:assigned managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.24.5.1.4 |
cucsIppoolPooledAssignedToDnCisco UCS ippool:Pooled:assignedToDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.5.1.5 |
cucsIppoolPooledDefGwCisco UCS ippool:Pooled:defGw managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.5.1.6 |
cucsIppoolPooledIdCisco UCS ippool:Pooled:id managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.5.1.7 |
cucsIppoolPooledPoolableDnCisco UCS ippool:Pooled:poolableDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.5.1.8 |
cucsIppoolPooledPrevAssignedToDnCisco UCS ippool:Pooled:prevAssignedToDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.5.1.9 |
cucsIppoolPooledSubnetCisco UCS ippool:Pooled:subnet managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.5.1.10 |
cucsIppoolPooledPrimDnsCisco UCS ippool:Pooled:primDns managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.5.1.11 |
cucsIppoolPooledSecDnsCisco UCS ippool:Pooled:secDns managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.5.1.12 |
cucsIppoolUniverseTableCisco UCS ippool:Universe managed object table SEQUENCE OF CucsIppoolUniverseEntry .1.3.6.1.4.1.9.9.719.1.24.6 |
cucsIppoolUniverseEntryEntry for the cucsIppoolUniverseTable table. CucsIppoolUniverseEntry .1.3.6.1.4.1.9.9.719.1.24.6.1 |
cucsIppoolUniverseInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.6.1.1 |
cucsIppoolUniverseDnCisco UCS ippool:Universe:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.6.1.2 |
cucsIppoolUniverseRnCisco UCS ippool:Universe:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.6.1.3 |
cucsIppoolIpV6AddrTableCisco UCS ippool:IpV6Addr managed object table SEQUENCE OF CucsIppoolIpV6AddrEntry .1.3.6.1.4.1.9.9.719.1.24.7 |
cucsIppoolIpV6AddrEntryEntry for the cucsIppoolIpV6AddrTable table. CucsIppoolIpV6AddrEntry .1.3.6.1.4.1.9.9.719.1.24.7.1 |
cucsIppoolIpV6AddrInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.7.1.1 |
cucsIppoolIpV6AddrDnCisco UCS ippool:IpV6Addr:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.7.1.2 |
cucsIppoolIpV6AddrRnCisco UCS ippool:IpV6Addr:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.7.1.3 |
cucsIppoolIpV6AddrAssignedCisco UCS ippool:IpV6Addr:assigned managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.24.7.1.4 |
cucsIppoolIpV6AddrAssignedToDnCisco UCS ippool:IpV6Addr:assignedToDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.7.1.5 |
cucsIppoolIpV6AddrIdCisco UCS ippool:IpV6Addr:id managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.7.1.6 |
cucsIppoolIpV6AddrOwnerCisco UCS ippool:IpV6Addr:owner managed object propertyro CucsPoolElementOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.24.7.1.7 |
cucsIppoolIpV6AddrGlobalAssignedCntCisco UCS ippool:IpV6Addr:globalAssignedCnt managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.7.1.8 |
cucsIppoolIpV6AddrGlobalDefinedCntCisco UCS ippool:IpV6Addr:globalDefinedCnt managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.7.1.9 |
cucsIppoolIpV6BlockTableCisco UCS ippool:IpV6Block managed object table SEQUENCE OF CucsIppoolIpV6BlockEntry .1.3.6.1.4.1.9.9.719.1.24.8 |
cucsIppoolIpV6BlockEntryEntry for the cucsIppoolIpV6BlockTable table. CucsIppoolIpV6BlockEntry .1.3.6.1.4.1.9.9.719.1.24.8.1 |
cucsIppoolIpV6BlockInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.8.1.1 |
cucsIppoolIpV6BlockDnCisco UCS ippool:IpV6Block:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.8.1.2 |
cucsIppoolIpV6BlockRnCisco UCS ippool:IpV6Block:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.8.1.3 |
cucsIppoolIpV6BlockDefGwCisco UCS ippool:IpV6Block:defGw managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.8.1.4 |
cucsIppoolIpV6BlockFromCisco UCS ippool:IpV6Block:from managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.8.1.5 |
cucsIppoolIpV6BlockPrefixCisco UCS ippool:IpV6Block:prefix managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.8.1.6 |
cucsIppoolIpV6BlockPrimDnsCisco UCS ippool:IpV6Block:primDns managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.8.1.7 |
cucsIppoolIpV6BlockSecDnsCisco UCS ippool:IpV6Block:secDns managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.8.1.8 |
cucsIppoolIpV6BlockToCisco UCS ippool:IpV6Block:to managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.8.1.9 |
cucsIppoolIpV6PooledTableCisco UCS ippool:IpV6Pooled managed object table SEQUENCE OF CucsIppoolIpV6PooledEntry .1.3.6.1.4.1.9.9.719.1.24.9 |
cucsIppoolIpV6PooledEntryEntry for the cucsIppoolIpV6PooledTable table. CucsIppoolIpV6PooledEntry .1.3.6.1.4.1.9.9.719.1.24.9.1 |
cucsIppoolIpV6PooledInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.9.1.1 |
cucsIppoolIpV6PooledDnCisco UCS ippool:IpV6Pooled:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.24.9.1.2 |
cucsIppoolIpV6PooledRnCisco UCS ippool:IpV6Pooled:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.9.1.3 |
cucsIppoolIpV6PooledAssignedCisco UCS ippool:IpV6Pooled:assigned managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.24.9.1.4 |
cucsIppoolIpV6PooledAssignedToDnCisco UCS ippool:IpV6Pooled:assignedToDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.9.1.5 |
cucsIppoolIpV6PooledDefGwCisco UCS ippool:IpV6Pooled:defGw managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.9.1.6 |
cucsIppoolIpV6PooledIdCisco UCS ippool:IpV6Pooled:id managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.9.1.7 |
cucsIppoolIpV6PooledPoolableDnCisco UCS ippool:IpV6Pooled:poolableDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.9.1.8 |
cucsIppoolIpV6PooledPrefixCisco UCS ippool:IpV6Pooled:prefix managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.24.9.1.9 |
cucsIppoolIpV6PooledPrevAssignedToDnCisco UCS ippool:IpV6Pooled:prevAssignedToDn managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.24.9.1.10 |
cucsIppoolIpV6PooledPrimDnsCisco UCS ippool:IpV6Pooled:primDns managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.9.1.11 |
cucsIppoolIpV6PooledSecDnsCisco UCS ippool:IpV6Pooled:secDns managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.24.9.1.12 |
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-ENTITY-VENDORTYPE-OID-MIB maps Cisco-specific hardware component identifiers to the ENTITY-MIB's entPhysicalTable, enabling precise differentiation of physical device types such as line cards, power supplies, and fans within Cisco infrastructure. This mapping ensures that SNMP management systems can accurately correlate physical inventory entries with vendor-specific component definitions for accurate device discovery and monitoring.
The CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB provides SNMP-based monitoring and management of Cisco Unified Computing System (UCS) hardware components, including chassis, blades, fabric interconnects, and power supplies. It exposes critical operational metrics such as device status, port states, temperature readings, fan speeds, and power consumption data for infrastructure health assessment.
The CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB enables SNMP-based monitoring and management of physical and virtual network adapter interfaces, including link status, traffic counters, error statistics, and port configuration parameters, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers.
The CISCO-UNIFIED-COMPUTING-TC-MIB module defines standard textual conventions and data type definitions required for monitoring Cisco Unified Computing System (UCS) hardware components, including server blades, fabric interconnects, and chassis resources. These definitions enable consistent interpretation of specific UCS metrics such as power supply status, fan speeds, thermal readings, and port utilization across SNMP management applications.
The CISCO-UNIFIED-COMPUTING-FABRIC-MIB enables SNMP-based monitoring and management of the Cisco UCS Fabric Interconnects and associated fabric switching infrastructure, exposing metrics for port states, link utilization, error counters, and fabric topology status. It facilitates granular visibility into the physical and logical fabric layers, including uplink/downlink interfaces, VLAN configurations, and fabric failover conditions within the unified computing environment.
The STARENT-MIB module provides SNMP management and monitoring capabilities for Cisco ASR 5000 and ASR 5500 multimedia core platforms, specifically exposing metrics related to 2G/3G/4G and WiFi subscriber sessions, inline service states, and carrier-class high-availability status.