CISCO-UNIFIED-COMPUTING-FCPOOL-MIB
The CISCO-UNIFIED-COMPUTING-FCPOOL-MIB enables monitoring and configuration of Fibre Channel storage pool resources within the Cisco Unified Computing System (UCS), specifically tracking pool capacity, allocated versus available storage, and port utilization states for SAN connectivity.
Imported Objects
Objects
82 total| Object Name |
|---|
cucsFcpoolObjects MODULE-IDENTITY .1.3.6.1.4.1.9.9.719.1.21 |
cucsFcpoolAddrTable SEQUENCE OF CucsFcpoolAddrEntry .1.3.6.1.4.1.9.9.719.1.21.1 |
cucsFcpoolAddrEntry CucsFcpoolAddrEntry .1.3.6.1.4.1.9.9.719.1.21.1.1 |
cucsFcpoolAddrInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.1.1.1 |
cucsFcpoolAddrDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.1.1.2 |
cucsFcpoolAddrRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.1.1.3 |
cucsFcpoolAddrAssignedro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.21.1.1.4 |
cucsFcpoolAddrAssignedToDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.1.1.5 |
cucsFcpoolAddrIdro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.21.1.1.6 |
cucsFcpoolAddrOwnerro CucsPoolElementOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.21.1.1.7 |
cucsFcpoolAddrGlobalAssignedCntro Gauge32 .1.3.6.1.4.1.9.9.719.1.21.1.1.8 |
cucsFcpoolAddrGlobalDefinedCntro Gauge32 .1.3.6.1.4.1.9.9.719.1.21.1.1.9 |
cucsFcpoolBlockTable SEQUENCE OF CucsFcpoolBlockEntry .1.3.6.1.4.1.9.9.719.1.21.2 |
cucsFcpoolBlockEntry CucsFcpoolBlockEntry .1.3.6.1.4.1.9.9.719.1.21.2.1 |
cucsFcpoolBlockInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.2.1.1 |
cucsFcpoolBlockDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.2.1.2 |
cucsFcpoolBlockRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.2.1.3 |
cucsFcpoolBlockFromro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.21.2.1.4 |
cucsFcpoolBlockToro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.21.2.1.5 |
cucsFcpoolBootTargetTable SEQUENCE OF CucsFcpoolBootTargetEntry .1.3.6.1.4.1.9.9.719.1.21.3 |
cucsFcpoolBootTargetEntry CucsFcpoolBootTargetEntry .1.3.6.1.4.1.9.9.719.1.21.3.1 |
cucsFcpoolBootTargetInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.3.1.1 |
cucsFcpoolBootTargetDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.3.1.2 |
cucsFcpoolBootTargetRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.3.1.3 |
cucsFcpoolBootTargetLunro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.3.1.4 |
cucsFcpoolBootTargetTypero CucsFcpoolBootTargetType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.21.3.1.5 |
cucsFcpoolBootTargetWwnro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.21.3.1.6 |
cucsFcpoolFormatTable SEQUENCE OF CucsFcpoolFormatEntry .1.3.6.1.4.1.9.9.719.1.21.4 |
cucsFcpoolFormatEntry CucsFcpoolFormatEntry .1.3.6.1.4.1.9.9.719.1.21.4.1 |
cucsFcpoolFormatInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.4.1.1 |
cucsFcpoolFormatDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.4.1.2 |
cucsFcpoolFormatRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.4.1.3 |
cucsFcpoolFormatFormatro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.21.4.1.4 |
cucsFcpoolFormatMaskro CucsAddressWWNMask (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.21.4.1.5 |
cucsFcpoolInitiatorTable SEQUENCE OF CucsFcpoolInitiatorEntry .1.3.6.1.4.1.9.9.719.1.21.5 |
cucsFcpoolInitiatorEntry CucsFcpoolInitiatorEntry .1.3.6.1.4.1.9.9.719.1.21.5.1 |
cucsFcpoolInitiatorInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.5.1.1 |
cucsFcpoolInitiatorDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.5.1.2 |
cucsFcpoolInitiatorRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.5.1.3 |
cucsFcpoolInitiatorAssignedro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.21.5.1.4 |
cucsFcpoolInitiatorAssignedToDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.5.1.5 |
cucsFcpoolInitiatorDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.5.1.6 |
cucsFcpoolInitiatorIdro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.21.5.1.7 |
cucsFcpoolInitiatorNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.5.1.8 |
cucsFcpoolInitiatorPoolableDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.5.1.9 |
cucsFcpoolInitiatorPrevAssignedToDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.5.1.10 |
cucsFcpoolInitiatorPurposero CucsFcpoolInitiatorPurpose (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.21.5.1.11 |
cucsFcpoolInitiatorsTable SEQUENCE OF CucsFcpoolInitiatorsEntry .1.3.6.1.4.1.9.9.719.1.21.6 |
cucsFcpoolInitiatorsEntry CucsFcpoolInitiatorsEntry .1.3.6.1.4.1.9.9.719.1.21.6.1 |
cucsFcpoolInitiatorsInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.6.1.1 |
cucsFcpoolInitiatorsDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.6.1.2 |
cucsFcpoolInitiatorsRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.6.1.3 |
cucsFcpoolInitiatorsAssignedro Gauge32 .1.3.6.1.4.1.9.9.719.1.21.6.1.4 |
cucsFcpoolInitiatorsDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.6.1.5 |
cucsFcpoolInitiatorsIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.6.1.6 |
cucsFcpoolInitiatorsNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.6.1.7 |
cucsFcpoolInitiatorsPurposero CucsFcpoolInitiatorsPurpose (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.21.6.1.8 |
cucsFcpoolInitiatorsSizero Gauge32 .1.3.6.1.4.1.9.9.719.1.21.6.1.9 |
cucsFcpoolInitiatorsAssignmentOrderro CucsFcpoolInitiatorsAssignmentOrder (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.21.6.1.10 |
cucsFcpoolInitiatorsMaxPortsPerNodero CucsFcpoolInitiatorsMaxPortsPerNode (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.21.6.1.11 |
cucsFcpoolInitiatorsPolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.21.6.1.12 |
cucsFcpoolInitiatorsPolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.21.6.1.13 |
cucsFcpoolPoolableTable SEQUENCE OF CucsFcpoolPoolableEntry .1.3.6.1.4.1.9.9.719.1.21.7 |
cucsFcpoolPoolableEntry CucsFcpoolPoolableEntry .1.3.6.1.4.1.9.9.719.1.21.7.1 |
cucsFcpoolPoolableInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.7.1.1 |
cucsFcpoolPoolableDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.7.1.2 |
cucsFcpoolPoolableRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.7.1.3 |
cucsFcpoolPoolableIdro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.21.7.1.4 |
cucsFcpoolPoolablePoolDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.7.1.5 |
cucsFcpoolUniverseTable SEQUENCE OF CucsFcpoolUniverseEntry .1.3.6.1.4.1.9.9.719.1.21.8 |
cucsFcpoolUniverseEntry CucsFcpoolUniverseEntry .1.3.6.1.4.1.9.9.719.1.21.8.1 |
cucsFcpoolUniverseInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.8.1.1 |
cucsFcpoolUniverseDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.8.1.2 |
cucsFcpoolUniverseRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.8.1.3 |
cucsFcpoolInitiatorEpTable SEQUENCE OF CucsFcpoolInitiatorEpEntry .1.3.6.1.4.1.9.9.719.1.21.9 |
cucsFcpoolInitiatorEpEntry CucsFcpoolInitiatorEpEntry .1.3.6.1.4.1.9.9.719.1.21.9.1 |
cucsFcpoolInitiatorEpInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.9.1.1 |
cucsFcpoolInitiatorEpDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.21.9.1.2 |
cucsFcpoolInitiatorEpRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.9.1.3 |
cucsFcpoolInitiatorEpIdro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.21.9.1.4 |
cucsFcpoolInitiatorEpInitiatorDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.21.9.1.5 |
cucsFcpoolInitiatorEpPurposero CucsFcpoolInitiatorEpPurpose (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.21.9.1.6 |
CISCO-UNIFIED-COMPUTING-FCPOOL-MIB Technical Reference Overview
The CISCO-UNIFIED-COMPUTING-FCPOOL-MIB SNMP MIB module published by Cisco defines 82 managed OID objects, including 63 scalar/column metrics, 9 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.719.1.21. Key tabular structures include cucsFcpoolAddrTable, cucsFcpoolBlockTable, cucsFcpoolBootTargetTable, cucsFcpoolFormatTable, cucsFcpoolInitiatorTable, cucsFcpoolInitiatorEpTable.
Key OID Definitions in CISCO-UNIFIED-COMPUTING-FCPOOL-MIB
.1.3.6.1.4.1.9.9.719.1.21MIB representation of the Cisco Unified Computing System FCPOOL management information model package
.1.3.6.1.4.1.9.9.719.1.21.1Cisco UCS fcpool:Addr managed object table
.1.3.6.1.4.1.9.9.719.1.21.2Cisco UCS fcpool:Block managed object table
.1.3.6.1.4.1.9.9.719.1.21.3Cisco UCS fcpool:BootTarget managed object table
.1.3.6.1.4.1.9.9.719.1.21.4Cisco UCS fcpool:Format managed object table
.1.3.6.1.4.1.9.9.719.1.21.5Cisco UCS fcpool:Initiator managed object table
.1.3.6.1.4.1.9.9.719.1.21.9Cisco UCS fcpool:InitiatorEp managed object table
.1.3.6.1.4.1.9.9.719.1.21.6Cisco UCS fcpool:Initiators managed object table
.1.3.6.1.4.1.9.9.719.1.21.7Cisco UCS fcpool:Poolable managed object table
.1.3.6.1.4.1.9.9.719.1.21.8Cisco UCS fcpool:Universe managed object table
.1.3.6.1.4.1.9.9.719.1.21.1.1Entry for the cucsFcpoolAddrTable table.
.1.3.6.1.4.1.9.9.719.1.21.1.1.1Instance identifier of the managed object.
.1.3.6.1.4.1.9.9.719.1.21.1.1.2Cisco UCS fcpool:Addr:dn managed object property
.1.3.6.1.4.1.9.9.719.1.21.1.1.3Cisco UCS fcpool:Addr:rn managed object property
.1.3.6.1.4.1.9.9.719.1.21.1.1.4Cisco UCS fcpool:Addr:assigned managed object property
.1.3.6.1.4.1.9.9.719.1.21.1.1.5Cisco UCS fcpool:Addr:assignedToDn managed object property
.1.3.6.1.4.1.9.9.719.1.21.1.1.6Cisco UCS fcpool:Addr:id managed object property
.1.3.6.1.4.1.9.9.719.1.21.1.1.7Cisco UCS fcpool:Addr:owner managed object property
.1.3.6.1.4.1.9.9.719.1.21.1.1.8Cisco UCS fcpool:Addr:globalAssignedCnt managed object property
.1.3.6.1.4.1.9.9.719.1.21.1.1.9Cisco UCS fcpool:Addr:globalDefinedCnt managed object property
.1.3.6.1.4.1.9.9.719.1.21.2.1Entry for the cucsFcpoolBlockTable table.
.1.3.6.1.4.1.9.9.719.1.21.2.1.1Instance identifier of the managed object.
.1.3.6.1.4.1.9.9.719.1.21.2.1.2Cisco UCS fcpool:Block:dn managed object property
.1.3.6.1.4.1.9.9.719.1.21.2.1.3Cisco UCS fcpool:Block:rn managed object property
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.