CISCO-UNIFIED-COMPUTING-DIAG-MIB
The CISCO-UNIFIED-COMPUTING-DIAG-MIB facilitates the monitoring and management of diagnostic status, fault isolation, and hardware health metrics within Cisco Unified Computing System (UCS) chassis, blades, and fabric interconnects via SNMP. It exposes specific diagnostic counters, sensor states, and error logs required for troubleshooting physical layer failures and component integrity in UCS environments.
Imported Objects
Objects
80 total| Object Name |
|---|
cucsDiagObjects MODULE-IDENTITY .1.3.6.1.4.1.9.9.719.1.12 |
cucsDiagRsltTable SEQUENCE OF CucsDiagRsltEntry .1.3.6.1.4.1.9.9.719.1.12.3 |
cucsDiagRsltEntry CucsDiagRsltEntry .1.3.6.1.4.1.9.9.719.1.12.3.1 |
cucsDiagRsltInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.12.3.1.1 |
cucsDiagRsltDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.12.3.1.2 |
cucsDiagRsltRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.3.1.3 |
cucsDiagRsltDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.3.1.4 |
cucsDiagRsltEndTsro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.12.3.1.5 |
cucsDiagRsltIdro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.3.1.6 |
cucsDiagRsltResultro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.3.1.7 |
cucsDiagRsltRsltStatusro CucsDiagStatus (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.3.1.8 |
cucsDiagRsltStartTsro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.12.3.1.9 |
cucsDiagRsltEstProgWeightro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.3.1.10 |
cucsDiagRsltProgressro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.3.1.11 |
cucsDiagRsltTestDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.3.1.12 |
cucsDiagRsltTestTypero CucsDiagTestType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.3.1.13 |
cucsDiagRunPolicyTable SEQUENCE OF CucsDiagRunPolicyEntry .1.3.6.1.4.1.9.9.719.1.12.4 |
cucsDiagRunPolicyEntry CucsDiagRunPolicyEntry .1.3.6.1.4.1.9.9.719.1.12.4.1 |
cucsDiagRunPolicyInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.12.4.1.1 |
cucsDiagRunPolicyDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.12.4.1.2 |
cucsDiagRunPolicyRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.4.1.3 |
cucsDiagRunPolicyDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.4.1.4 |
cucsDiagRunPolicyFailureActionro CucsDiagFailureAction (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.4.1.5 |
cucsDiagRunPolicyIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.4.1.6 |
cucsDiagRunPolicyNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.4.1.7 |
cucsDiagRunPolicySuccessActionro CucsDiagSuccessAction (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.4.1.8 |
cucsDiagRunPolicyPolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.4.1.9 |
cucsDiagRunPolicyPolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.4.1.10 |
cucsDiagSrvCapProviderTable SEQUENCE OF CucsDiagSrvCapProviderEntry .1.3.6.1.4.1.9.9.719.1.12.5 |
cucsDiagSrvCapProviderEntry CucsDiagSrvCapProviderEntry .1.3.6.1.4.1.9.9.719.1.12.5.1 |
cucsDiagSrvCapProviderInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.12.5.1.1 |
cucsDiagSrvCapProviderDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.12.5.1.2 |
cucsDiagSrvCapProviderRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.5.1.3 |
cucsDiagSrvCapProviderDeprecatedro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.12.5.1.4 |
cucsDiagSrvCapProviderGencountro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.5.1.5 |
cucsDiagSrvCapProviderMgmtPlaneVerro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.5.1.6 |
cucsDiagSrvCapProviderModelro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.5.1.7 |
cucsDiagSrvCapProviderRevisionro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.5.1.8 |
cucsDiagSrvCapProviderVendorro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.5.1.9 |
cucsDiagSrvCapProviderPromCardTypero Gauge32 .1.3.6.1.4.1.9.9.719.1.12.5.1.10 |
cucsDiagSrvCapProviderDeletedro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.12.5.1.11 |
cucsDiagSrvCapProviderElementLoadFailuresro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.5.1.12 |
cucsDiagSrvCapProviderElementsLoadedro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.5.1.13 |
cucsDiagSrvCapProviderLoadErrorsro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.5.1.14 |
cucsDiagSrvCapProviderLoadWarningsro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.5.1.15 |
cucsDiagSrvCtrlTable SEQUENCE OF CucsDiagSrvCtrlEntry .1.3.6.1.4.1.9.9.719.1.12.6 |
cucsDiagSrvCtrlEntry CucsDiagSrvCtrlEntry .1.3.6.1.4.1.9.9.719.1.12.6.1 |
cucsDiagSrvCtrlInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.12.6.1.1 |
cucsDiagSrvCtrlDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.12.6.1.2 |
cucsDiagSrvCtrlRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.6.1.3 |
cucsDiagSrvCtrlAdminStatero CucsDiagAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.6.1.4 |
cucsDiagSrvCtrlOperQualifierro CucsDiagStatusIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.6.1.7 |
cucsDiagSrvCtrlOperStatero CucsDiagStatus (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.6.1.8 |
cucsDiagSrvCtrlRunPolicyNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.6.1.9 |
cucsDiagSrvCtrlEndTsro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.12.6.1.11 |
cucsDiagSrvCtrlEndTsMro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.12.6.1.12 |
cucsDiagSrvCtrlErrorDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.6.1.13 |
cucsDiagSrvCtrlStartTsro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.12.6.1.14 |
cucsDiagSrvCtrlStartTsMro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.12.6.1.15 |
cucsDiagSrvCtrlOverallProgressro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.6.1.16 |
cucsDiagLogEpTable SEQUENCE OF CucsDiagLogEpEntry .1.3.6.1.4.1.9.9.719.1.12.7 |
cucsDiagLogEpEntry CucsDiagLogEpEntry .1.3.6.1.4.1.9.9.719.1.12.7.1 |
cucsDiagLogEpInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.12.7.1.1 |
cucsDiagLogEpDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.12.7.1.2 |
cucsDiagLogEpRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.7.1.3 |
cucsDiagLogEpLogDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.7.1.4 |
cucsDiagLogEpSwitchIdro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.7.1.5 |
cucsDiagMemoryTestTable SEQUENCE OF CucsDiagMemoryTestEntry .1.3.6.1.4.1.9.9.719.1.12.8 |
cucsDiagMemoryTestEntry CucsDiagMemoryTestEntry .1.3.6.1.4.1.9.9.719.1.12.8.1 |
cucsDiagMemoryTestInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.12.8.1.1 |
cucsDiagMemoryTestDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.12.8.1.2 |
cucsDiagMemoryTestRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.12.8.1.3 |
cucsDiagMemoryTestCpuFilterro CucsDiagCpuFilter (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.8.1.4 |
cucsDiagMemoryTestIdro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.8.1.5 |
cucsDiagMemoryTestLoopCountro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.8.1.6 |
cucsDiagMemoryTestMemChunkSizero CucsDiagMemChunkSize (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.8.1.7 |
cucsDiagMemoryTestMemSizero Gauge32 .1.3.6.1.4.1.9.9.719.1.12.8.1.8 |
cucsDiagMemoryTestOrderro Gauge32 .1.3.6.1.4.1.9.9.719.1.12.8.1.9 |
cucsDiagMemoryTestPatternro CucsDiagPattern (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.8.1.10 |
cucsDiagMemoryTestTypero CucsDiagTestType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.12.8.1.11 |
CISCO-UNIFIED-COMPUTING-DIAG-MIB Technical Reference Overview
The CISCO-UNIFIED-COMPUTING-DIAG-MIB SNMP MIB module published by Cisco defines 80 managed OID objects, including 67 scalar/column metrics, 6 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.719.1.12. Key tabular structures include cucsDiagLogEpTable, cucsDiagMemoryTestTable, cucsDiagRsltTable, cucsDiagRunPolicyTable, cucsDiagSrvCapProviderTable, cucsDiagSrvCtrlTable.
Key OID Definitions in CISCO-UNIFIED-COMPUTING-DIAG-MIB
.1.3.6.1.4.1.9.9.719.1.12MIB representation of the Cisco Unified Computing System DIAG management information model package
.1.3.6.1.4.1.9.9.719.1.12.7Cisco UCS diag:LogEp managed object table
.1.3.6.1.4.1.9.9.719.1.12.8Cisco UCS diag:MemoryTest managed object table
.1.3.6.1.4.1.9.9.719.1.12.3Cisco UCS diag:Rslt managed object table
.1.3.6.1.4.1.9.9.719.1.12.4Cisco UCS diag:RunPolicy managed object table
.1.3.6.1.4.1.9.9.719.1.12.5Cisco UCS diag:SrvCapProvider managed object table
.1.3.6.1.4.1.9.9.719.1.12.6Cisco UCS diag:SrvCtrl managed object table
.1.3.6.1.4.1.9.9.719.1.12.7.1Entry for the cucsDiagLogEpTable table.
.1.3.6.1.4.1.9.9.719.1.12.7.1.1Instance identifier of the managed object.
.1.3.6.1.4.1.9.9.719.1.12.7.1.2Cisco UCS diag:LogEp:dn managed object property
.1.3.6.1.4.1.9.9.719.1.12.7.1.3Cisco UCS diag:LogEp:rn managed object property
.1.3.6.1.4.1.9.9.719.1.12.7.1.4Cisco UCS diag:LogEp:logDn managed object property
.1.3.6.1.4.1.9.9.719.1.12.7.1.5Cisco UCS diag:LogEp:switchId managed object property
.1.3.6.1.4.1.9.9.719.1.12.8.1Entry for the cucsDiagMemoryTestTable table.
.1.3.6.1.4.1.9.9.719.1.12.8.1.1Instance identifier of the managed object.
.1.3.6.1.4.1.9.9.719.1.12.8.1.2Cisco UCS diag:MemoryTest:dn managed object property
.1.3.6.1.4.1.9.9.719.1.12.8.1.3Cisco UCS diag:MemoryTest:rn managed object property
.1.3.6.1.4.1.9.9.719.1.12.8.1.4Cisco UCS diag:MemoryTest:cpuFilter managed object property
.1.3.6.1.4.1.9.9.719.1.12.8.1.5Cisco UCS diag:MemoryTest:id managed object property
.1.3.6.1.4.1.9.9.719.1.12.8.1.6Cisco UCS diag:MemoryTest:loopCount managed object property
.1.3.6.1.4.1.9.9.719.1.12.8.1.7Cisco UCS diag:MemoryTest:memChunkSize managed object property
.1.3.6.1.4.1.9.9.719.1.12.8.1.8Cisco UCS diag:MemoryTest:memSize managed object property
.1.3.6.1.4.1.9.9.719.1.12.8.1.9Cisco UCS diag:MemoryTest:order managed object property
.1.3.6.1.4.1.9.9.719.1.12.8.1.10Cisco UCS diag:MemoryTest:pattern managed object property
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.