Home/Catalog/CISCO-UNIFIED-COMPUTING-DIAG-MIB

CISCO-UNIFIED-COMPUTING-DIAG-MIB

AI MIB Summary

The CISCO-UNIFIED-COMPUTING-DIAG-MIB facilitates the monitoring and management of diagnostic status, fault isolation, and hardware health metrics within Cisco Unified Computing System (UCS) chassis, blades, and fabric interconnects via SNMP. It exposes specific diagnostic counters, sensor states, and error logs required for troubleshooting physical layer failures and component integrity in UCS environments.

MIB representation of the Cisco Unified Computing System DIAG management information model package
Main OID:
cucsDiagObjects.1.3.6.1.4.1.9.9.719.1.12
80
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

80 total
Object Name
cucsDiagObjects
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.719.1.12
cucsDiagRsltTable
SEQUENCE OF CucsDiagRsltEntry
.1.3.6.1.4.1.9.9.719.1.12.3
cucsDiagRsltEntry
CucsDiagRsltEntry
.1.3.6.1.4.1.9.9.719.1.12.3.1
cucsDiagRsltInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.1
cucsDiagRsltDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.2
cucsDiagRsltRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.3
cucsDiagRsltDescrro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.4
cucsDiagRsltEndTsro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.12.3.1.5
cucsDiagRsltIdro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.3.1.6
cucsDiagRsltResultro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.3.1.7
cucsDiagRsltRsltStatusro
CucsDiagStatus (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.8
cucsDiagRsltStartTsro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.12.3.1.9
cucsDiagRsltEstProgWeightro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.3.1.10
cucsDiagRsltProgressro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.3.1.11
cucsDiagRsltTestDnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.12
cucsDiagRsltTestTypero
CucsDiagTestType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.13
cucsDiagRunPolicyTable
SEQUENCE OF CucsDiagRunPolicyEntry
.1.3.6.1.4.1.9.9.719.1.12.4
cucsDiagRunPolicyEntry
CucsDiagRunPolicyEntry
.1.3.6.1.4.1.9.9.719.1.12.4.1
cucsDiagRunPolicyInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.1
cucsDiagRunPolicyDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.2
cucsDiagRunPolicyRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.3
cucsDiagRunPolicyDescrro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.4
cucsDiagRunPolicyFailureActionro
CucsDiagFailureAction (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.5
cucsDiagRunPolicyIntIdro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.6
cucsDiagRunPolicyNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.7
cucsDiagRunPolicySuccessActionro
CucsDiagSuccessAction (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.8
cucsDiagRunPolicyPolicyLevelro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.4.1.9
cucsDiagRunPolicyPolicyOwnerro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.10
cucsDiagSrvCapProviderTable
SEQUENCE OF CucsDiagSrvCapProviderEntry
.1.3.6.1.4.1.9.9.719.1.12.5
cucsDiagSrvCapProviderEntry
CucsDiagSrvCapProviderEntry
.1.3.6.1.4.1.9.9.719.1.12.5.1
cucsDiagSrvCapProviderInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.1
cucsDiagSrvCapProviderDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.2
cucsDiagSrvCapProviderRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.3
cucsDiagSrvCapProviderDeprecatedro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.12.5.1.4
cucsDiagSrvCapProviderGencountro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.5.1.5
cucsDiagSrvCapProviderMgmtPlaneVerro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.6
cucsDiagSrvCapProviderModelro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.7
cucsDiagSrvCapProviderRevisionro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.8
cucsDiagSrvCapProviderVendorro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.9
cucsDiagSrvCapProviderPromCardTypero
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.5.1.10
cucsDiagSrvCapProviderDeletedro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.12.5.1.11
cucsDiagSrvCapProviderElementLoadFailuresro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.5.1.12
cucsDiagSrvCapProviderElementsLoadedro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.5.1.13
cucsDiagSrvCapProviderLoadErrorsro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.5.1.14
cucsDiagSrvCapProviderLoadWarningsro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.5.1.15
cucsDiagSrvCtrlTable
SEQUENCE OF CucsDiagSrvCtrlEntry
.1.3.6.1.4.1.9.9.719.1.12.6
cucsDiagSrvCtrlEntry
CucsDiagSrvCtrlEntry
.1.3.6.1.4.1.9.9.719.1.12.6.1
cucsDiagSrvCtrlInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.1
cucsDiagSrvCtrlDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.2
cucsDiagSrvCtrlRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.3
cucsDiagSrvCtrlAdminStatero
CucsDiagAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.4
cucsDiagSrvCtrlOperQualifierro
CucsDiagStatusIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.7
cucsDiagSrvCtrlOperStatero
CucsDiagStatus (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.8
cucsDiagSrvCtrlRunPolicyNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.9
cucsDiagSrvCtrlEndTsro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.12.6.1.11
cucsDiagSrvCtrlEndTsMro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.12.6.1.12
cucsDiagSrvCtrlErrorDescrro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.13
cucsDiagSrvCtrlStartTsro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.12.6.1.14
cucsDiagSrvCtrlStartTsMro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.12.6.1.15
cucsDiagSrvCtrlOverallProgressro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.6.1.16
cucsDiagLogEpTable
SEQUENCE OF CucsDiagLogEpEntry
.1.3.6.1.4.1.9.9.719.1.12.7
cucsDiagLogEpEntry
CucsDiagLogEpEntry
.1.3.6.1.4.1.9.9.719.1.12.7.1
cucsDiagLogEpInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.7.1.1
cucsDiagLogEpDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.7.1.2
cucsDiagLogEpRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.7.1.3
cucsDiagLogEpLogDnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.7.1.4
cucsDiagLogEpSwitchIdro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.7.1.5
cucsDiagMemoryTestTable
SEQUENCE OF CucsDiagMemoryTestEntry
.1.3.6.1.4.1.9.9.719.1.12.8
cucsDiagMemoryTestEntry
CucsDiagMemoryTestEntry
.1.3.6.1.4.1.9.9.719.1.12.8.1
cucsDiagMemoryTestInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.1
cucsDiagMemoryTestDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.2
cucsDiagMemoryTestRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.3
cucsDiagMemoryTestCpuFilterro
CucsDiagCpuFilter (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.4
cucsDiagMemoryTestIdro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.8.1.5
cucsDiagMemoryTestLoopCountro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.8.1.6
cucsDiagMemoryTestMemChunkSizero
CucsDiagMemChunkSize (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.7
cucsDiagMemoryTestMemSizero
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.8.1.8
cucsDiagMemoryTestOrderro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.8.1.9
cucsDiagMemoryTestPatternro
CucsDiagPattern (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.10
cucsDiagMemoryTestTypero
CucsDiagTestType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.11

CISCO-UNIFIED-COMPUTING-DIAG-MIB Technical Reference Overview

The CISCO-UNIFIED-COMPUTING-DIAG-MIB SNMP MIB module published by Cisco defines 80 managed OID objects, including 67 scalar/column metrics, 6 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.719.1.12. Key tabular structures include cucsDiagLogEpTable, cucsDiagMemoryTestTable, cucsDiagRsltTable, cucsDiagRunPolicyTable, cucsDiagSrvCapProviderTable, cucsDiagSrvCtrlTable.

Key OID Definitions in CISCO-UNIFIED-COMPUTING-DIAG-MIB

cucsDiagObjectsMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.719.1.12

MIB representation of the Cisco Unified Computing System DIAG management information model package

cucsDiagLogEpTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.12.7

Cisco UCS diag:LogEp managed object table

cucsDiagMemoryTestTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.12.8

Cisco UCS diag:MemoryTest managed object table

cucsDiagRsltTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.12.3

Cisco UCS diag:Rslt managed object table

cucsDiagRunPolicyTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.12.4

Cisco UCS diag:RunPolicy managed object table

cucsDiagSrvCapProviderTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.12.5

Cisco UCS diag:SrvCapProvider managed object table

cucsDiagSrvCtrlTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.12.6

Cisco UCS diag:SrvCtrl managed object table

cucsDiagLogEpEntryCucsDiagLogEpEntrynot-accessible
.1.3.6.1.4.1.9.9.719.1.12.7.1

Entry for the cucsDiagLogEpTable table.

cucsDiagLogEpInstanceIdCucsManagedObjectIdnot-accessible
.1.3.6.1.4.1.9.9.719.1.12.7.1.1

Instance identifier of the managed object.

cucsDiagLogEpDnCucsManagedObjectDnread-only
.1.3.6.1.4.1.9.9.719.1.12.7.1.2

Cisco UCS diag:LogEp:dn managed object property

cucsDiagLogEpRnSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.12.7.1.3

Cisco UCS diag:LogEp:rn managed object property

cucsDiagLogEpLogDnSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.12.7.1.4

Cisco UCS diag:LogEp:logDn managed object property

cucsDiagLogEpSwitchIdCucsNetworkSwitchIdread-only
.1.3.6.1.4.1.9.9.719.1.12.7.1.5

Cisco UCS diag:LogEp:switchId managed object property

cucsDiagMemoryTestEntryCucsDiagMemoryTestEntrynot-accessible
.1.3.6.1.4.1.9.9.719.1.12.8.1

Entry for the cucsDiagMemoryTestTable table.

cucsDiagMemoryTestInstanceIdCucsManagedObjectIdnot-accessible
.1.3.6.1.4.1.9.9.719.1.12.8.1.1

Instance identifier of the managed object.

cucsDiagMemoryTestDnCucsManagedObjectDnread-only
.1.3.6.1.4.1.9.9.719.1.12.8.1.2

Cisco UCS diag:MemoryTest:dn managed object property

cucsDiagMemoryTestRnSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.12.8.1.3

Cisco UCS diag:MemoryTest:rn managed object property

cucsDiagMemoryTestCpuFilterCucsDiagCpuFilterread-only
.1.3.6.1.4.1.9.9.719.1.12.8.1.4

Cisco UCS diag:MemoryTest:cpuFilter managed object property

cucsDiagMemoryTestIdGauge32read-only
.1.3.6.1.4.1.9.9.719.1.12.8.1.5

Cisco UCS diag:MemoryTest:id managed object property

cucsDiagMemoryTestLoopCountGauge32read-only
.1.3.6.1.4.1.9.9.719.1.12.8.1.6

Cisco UCS diag:MemoryTest:loopCount managed object property

cucsDiagMemoryTestMemChunkSizeCucsDiagMemChunkSizeread-only
.1.3.6.1.4.1.9.9.719.1.12.8.1.7

Cisco UCS diag:MemoryTest:memChunkSize managed object property

cucsDiagMemoryTestMemSizeGauge32read-only
.1.3.6.1.4.1.9.9.719.1.12.8.1.8

Cisco UCS diag:MemoryTest:memSize managed object property

cucsDiagMemoryTestOrderGauge32read-only
.1.3.6.1.4.1.9.9.719.1.12.8.1.9

Cisco UCS diag:MemoryTest:order managed object property

cucsDiagMemoryTestPatternCucsDiagPatternread-only
.1.3.6.1.4.1.9.9.719.1.12.8.1.10

Cisco UCS diag:MemoryTest:pattern managed object property

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→