Home/Catalog/CISCO-UNIFIED-COMPUTING-DIAG-MIB

CISCO-UNIFIED-COMPUTING-DIAG-MIB

AI MIB Summary

The CISCO-UNIFIED-COMPUTING-DIAG-MIB facilitates the monitoring and management of diagnostic status, fault isolation, and hardware health metrics within Cisco Unified Computing System (UCS) chassis, blades, and fabric interconnects via SNMP. It exposes specific diagnostic counters, sensor states, and error logs required for troubleshooting physical layer failures and component integrity in UCS environments.

MIB representation of the Cisco Unified Computing System DIAG management information model package
Main OID:
cucsDiagObjects.1.3.6.1.4.1.9.9.719.1.12
80
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

80 total
Object Name
cucsDiagObjectsMIB representation of the Cisco Unified Computing System DIAG management information model package
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.719.1.12
cucsDiagRsltTableCisco UCS diag:Rslt managed object table
SEQUENCE OF CucsDiagRsltEntry
.1.3.6.1.4.1.9.9.719.1.12.3
cucsDiagRsltEntryEntry for the cucsDiagRsltTable table.
CucsDiagRsltEntry
.1.3.6.1.4.1.9.9.719.1.12.3.1
cucsDiagRsltInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.1
cucsDiagRsltDnCisco UCS diag:Rslt:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.2
cucsDiagRsltRnCisco UCS diag:Rslt:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.3
cucsDiagRsltDescrCisco UCS diag:Rslt:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.4
cucsDiagRsltEndTsCisco UCS diag:Rslt:endTs managed object propertyro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.12.3.1.5
cucsDiagRsltIdCisco UCS diag:Rslt:id managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.3.1.6
cucsDiagRsltResultCisco UCS diag:Rslt:result managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.3.1.7
cucsDiagRsltRsltStatusCisco UCS diag:Rslt:rsltStatus managed object propertyro
CucsDiagStatus (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.8
cucsDiagRsltStartTsCisco UCS diag:Rslt:startTs managed object propertyro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.12.3.1.9
cucsDiagRsltEstProgWeightCisco UCS diag:Rslt:estProgWeight managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.3.1.10
cucsDiagRsltProgressCisco UCS diag:Rslt:progress managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.3.1.11
cucsDiagRsltTestDnCisco UCS diag:Rslt:testDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.12
cucsDiagRsltTestTypeCisco UCS diag:Rslt:testType managed object propertyro
CucsDiagTestType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.3.1.13
cucsDiagRunPolicyTableCisco UCS diag:RunPolicy managed object table
SEQUENCE OF CucsDiagRunPolicyEntry
.1.3.6.1.4.1.9.9.719.1.12.4
cucsDiagRunPolicyEntryEntry for the cucsDiagRunPolicyTable table.
CucsDiagRunPolicyEntry
.1.3.6.1.4.1.9.9.719.1.12.4.1
cucsDiagRunPolicyInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.1
cucsDiagRunPolicyDnCisco UCS diag:RunPolicy:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.2
cucsDiagRunPolicyRnCisco UCS diag:RunPolicy:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.3
cucsDiagRunPolicyDescrCisco UCS diag:RunPolicy:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.4
cucsDiagRunPolicyFailureActionCisco UCS diag:RunPolicy:failureAction managed object propertyro
CucsDiagFailureAction (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.5
cucsDiagRunPolicyIntIdCisco UCS diag:RunPolicy:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.6
cucsDiagRunPolicyNameCisco UCS diag:RunPolicy:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.7
cucsDiagRunPolicySuccessActionCisco UCS diag:RunPolicy:successAction managed object propertyro
CucsDiagSuccessAction (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.8
cucsDiagRunPolicyPolicyLevelCisco UCS diag:RunPolicy:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.4.1.9
cucsDiagRunPolicyPolicyOwnerCisco UCS diag:RunPolicy:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.4.1.10
cucsDiagSrvCapProviderTableCisco UCS diag:SrvCapProvider managed object table
SEQUENCE OF CucsDiagSrvCapProviderEntry
.1.3.6.1.4.1.9.9.719.1.12.5
cucsDiagSrvCapProviderEntryEntry for the cucsDiagSrvCapProviderTable table.
CucsDiagSrvCapProviderEntry
.1.3.6.1.4.1.9.9.719.1.12.5.1
cucsDiagSrvCapProviderInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.1
cucsDiagSrvCapProviderDnCisco UCS diag:SrvCapProvider:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.2
cucsDiagSrvCapProviderRnCisco UCS diag:SrvCapProvider:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.3
cucsDiagSrvCapProviderDeprecatedCisco UCS diag:SrvCapProvider:deprecated managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.12.5.1.4
cucsDiagSrvCapProviderGencountCisco UCS diag:SrvCapProvider:gencount managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.5.1.5
cucsDiagSrvCapProviderMgmtPlaneVerCisco UCS diag:SrvCapProvider:mgmtPlaneVer managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.6
cucsDiagSrvCapProviderModelCisco UCS diag:SrvCapProvider:model managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.7
cucsDiagSrvCapProviderRevisionCisco UCS diag:SrvCapProvider:revision managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.8
cucsDiagSrvCapProviderVendorCisco UCS diag:SrvCapProvider:vendor managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.5.1.9
cucsDiagSrvCapProviderPromCardTypeCisco UCS diag:SrvCapProvider:promCardType managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.5.1.10
cucsDiagSrvCapProviderDeletedCisco UCS diag:SrvCapProvider:deleted managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.12.5.1.11
cucsDiagSrvCapProviderElementLoadFailuresCisco UCS diag:SrvCapProvider:elementLoadFailures managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.5.1.12
cucsDiagSrvCapProviderElementsLoadedCisco UCS diag:SrvCapProvider:elementsLoaded managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.5.1.13
cucsDiagSrvCapProviderLoadErrorsCisco UCS diag:SrvCapProvider:loadErrors managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.5.1.14
cucsDiagSrvCapProviderLoadWarningsCisco UCS diag:SrvCapProvider:loadWarnings managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.5.1.15
cucsDiagSrvCtrlTableCisco UCS diag:SrvCtrl managed object table
SEQUENCE OF CucsDiagSrvCtrlEntry
.1.3.6.1.4.1.9.9.719.1.12.6
cucsDiagSrvCtrlEntryEntry for the cucsDiagSrvCtrlTable table.
CucsDiagSrvCtrlEntry
.1.3.6.1.4.1.9.9.719.1.12.6.1
cucsDiagSrvCtrlInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.1
cucsDiagSrvCtrlDnCisco UCS diag:SrvCtrl:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.2
cucsDiagSrvCtrlRnCisco UCS diag:SrvCtrl:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.3
cucsDiagSrvCtrlAdminStateCisco UCS diag:SrvCtrl:adminState managed object propertyro
CucsDiagAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.4
cucsDiagSrvCtrlOperQualifierCisco UCS diag:SrvCtrl:operQualifier managed object propertyro
CucsDiagStatusIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.7
cucsDiagSrvCtrlOperStateCisco UCS diag:SrvCtrl:operState managed object propertyro
CucsDiagStatus (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.8
cucsDiagSrvCtrlRunPolicyNameCisco UCS diag:SrvCtrl:runPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.9
cucsDiagSrvCtrlEndTsCisco UCS diag:SrvCtrl:endTs managed object propertyro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.12.6.1.11
cucsDiagSrvCtrlEndTsMCisco UCS diag:SrvCtrl:endTsM managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.12.6.1.12
cucsDiagSrvCtrlErrorDescrCisco UCS diag:SrvCtrl:errorDescr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.6.1.13
cucsDiagSrvCtrlStartTsCisco UCS diag:SrvCtrl:startTs managed object propertyro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.12.6.1.14
cucsDiagSrvCtrlStartTsMCisco UCS diag:SrvCtrl:startTsM managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.12.6.1.15
cucsDiagSrvCtrlOverallProgressCisco UCS diag:SrvCtrl:overallProgress managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.6.1.16
cucsDiagLogEpTableCisco UCS diag:LogEp managed object table
SEQUENCE OF CucsDiagLogEpEntry
.1.3.6.1.4.1.9.9.719.1.12.7
cucsDiagLogEpEntryEntry for the cucsDiagLogEpTable table.
CucsDiagLogEpEntry
.1.3.6.1.4.1.9.9.719.1.12.7.1
cucsDiagLogEpInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.7.1.1
cucsDiagLogEpDnCisco UCS diag:LogEp:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.7.1.2
cucsDiagLogEpRnCisco UCS diag:LogEp:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.7.1.3
cucsDiagLogEpLogDnCisco UCS diag:LogEp:logDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.7.1.4
cucsDiagLogEpSwitchIdCisco UCS diag:LogEp:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.7.1.5
cucsDiagMemoryTestTableCisco UCS diag:MemoryTest managed object table
SEQUENCE OF CucsDiagMemoryTestEntry
.1.3.6.1.4.1.9.9.719.1.12.8
cucsDiagMemoryTestEntryEntry for the cucsDiagMemoryTestTable table.
CucsDiagMemoryTestEntry
.1.3.6.1.4.1.9.9.719.1.12.8.1
cucsDiagMemoryTestInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.1
cucsDiagMemoryTestDnCisco UCS diag:MemoryTest:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.2
cucsDiagMemoryTestRnCisco UCS diag:MemoryTest:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.3
cucsDiagMemoryTestCpuFilterCisco UCS diag:MemoryTest:cpuFilter managed object propertyro
CucsDiagCpuFilter (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.4
cucsDiagMemoryTestIdCisco UCS diag:MemoryTest:id managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.8.1.5
cucsDiagMemoryTestLoopCountCisco UCS diag:MemoryTest:loopCount managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.8.1.6
cucsDiagMemoryTestMemChunkSizeCisco UCS diag:MemoryTest:memChunkSize managed object propertyro
CucsDiagMemChunkSize (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.7
cucsDiagMemoryTestMemSizeCisco UCS diag:MemoryTest:memSize managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.8.1.8
cucsDiagMemoryTestOrderCisco UCS diag:MemoryTest:order managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.12.8.1.9
cucsDiagMemoryTestPatternCisco UCS diag:MemoryTest:pattern managed object propertyro
CucsDiagPattern (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.10
cucsDiagMemoryTestTypeCisco UCS diag:MemoryTest:type managed object propertyro
CucsDiagTestType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.12.8.1.11

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-ENTITY-VENDORTYPE-OID-MIB

The CISCO-ENTITY-VENDORTYPE-OID-MIB maps Cisco-specific hardware component identifiers to the ENTITY-MIB's entPhysicalTable, enabling precise differentiation of physical device types such as line cards, power supplies, and fans within Cisco infrastructure. This mapping ensures that SNMP management systems can accurately correlate physical inventory entries with vendor-specific component definitions for accurate device discovery and monitoring.

7820 objects→
CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

The CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB provides SNMP-based monitoring and management of Cisco Unified Computing System (UCS) hardware components, including chassis, blades, fabric interconnects, and power supplies. It exposes critical operational metrics such as device status, port states, temperature readings, fan speeds, and power consumption data for infrastructure health assessment.

3349 objects→
CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB

The CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB enables SNMP-based monitoring and management of physical and virtual network adapter interfaces, including link status, traffic counters, error statistics, and port configuration parameters, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers.

2840 objects→
CISCO-UNIFIED-COMPUTING-TC-MIB

The CISCO-UNIFIED-COMPUTING-TC-MIB module defines standard textual conventions and data type definitions required for monitoring Cisco Unified Computing System (UCS) hardware components, including server blades, fabric interconnects, and chassis resources. These definitions enable consistent interpretation of specific UCS metrics such as power supply status, fan speeds, thermal readings, and port utilization across SNMP management applications.

2614 objects→
CISCO-UNIFIED-COMPUTING-FABRIC-MIB

The CISCO-UNIFIED-COMPUTING-FABRIC-MIB enables SNMP-based monitoring and management of the Cisco UCS Fabric Interconnects and associated fabric switching infrastructure, exposing metrics for port states, link utilization, error counters, and fabric topology status. It facilitates granular visibility into the physical and logical fabric layers, including uplink/downlink interfaces, VLAN configurations, and fabric failover conditions within the unified computing environment.

2407 objects→
STARENT-MIB

The STARENT-MIB module provides SNMP management and monitoring capabilities for Cisco ASR 5000 and ASR 5500 multimedia core platforms, specifically exposing metrics related to 2G/3G/4G and WiFi subscriber sessions, inline service states, and carrier-class high-availability status.

2194 objects→