CISCO-UNIFIED-COMPUTING-CPMAINT-MIB
The CISCO-UNIFIED-COMPUTING-CPMAINT-MIB enables SNMP-based monitoring and management of maintenance-related status, fault conditions, and operational events within the Cisco Unified Computing System (UCS) chassis and blade server infrastructure. This module specifically tracks CPMAINT (Chassis Platform Maintenance) state transitions, hardware component health, and scheduled maintenance window indicators to facilitate proactive infrastructure reliability.
Imported Objects
Objects
45 total| Object Name |
|---|
cucsCpmaintObjects MODULE-IDENTITY .1.3.6.1.4.1.9.9.719.1.93 |
cucsCpmaintAckTable SEQUENCE OF CucsCpmaintAckEntry .1.3.6.1.4.1.9.9.719.1.93.1 |
cucsCpmaintAckEntry CucsCpmaintAckEntry .1.3.6.1.4.1.9.9.719.1.93.1.1 |
cucsCpmaintAckInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.1 |
cucsCpmaintAckDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.2 |
cucsCpmaintAckRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.3 |
cucsCpmaintAckAckedro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.93.1.1.4 |
cucsCpmaintAckAckedByro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.5 |
cucsCpmaintAckAdminStatero CucsTrigAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.6 |
cucsCpmaintAckAutoDeletero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.93.1.1.7 |
cucsCpmaintAckChangeByro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.8 |
cucsCpmaintAckChangeDetailsro CucsCpmaintAckChangeDetails (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.9 |
cucsCpmaintAckChangeModero CucsCpmaintChangeMode (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.10 |
cucsCpmaintAckChangesro CucsCpmaintAckChanges (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.11 |
cucsCpmaintAckConfigIssuesro CucsEquipmentChassisConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.12 |
cucsCpmaintAckDeploymentModero CucsTrigChassisAckMode (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.13 |
cucsCpmaintAckDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.14 |
cucsCpmaintAckDisrro CucsCpmaintAckDisr (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.15 |
cucsCpmaintAckIgnoreCapro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.93.1.1.16 |
cucsCpmaintAckIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.17 |
cucsCpmaintAckModifiedro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.93.1.1.18 |
cucsCpmaintAckNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.19 |
cucsCpmaintAckOldChassisDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.20 |
cucsCpmaintAckOperSchedulerro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.21 |
cucsCpmaintAckOperStatero CucsTrigAckOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.22 |
cucsCpmaintAckPolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.93.1.1.23 |
cucsCpmaintAckPolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.24 |
cucsCpmaintAckPrevOperStatero CucsTrigAckPrevOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.25 |
cucsCpmaintAckSchedulerro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.26 |
cucsCpmaintAckTriggerConfigStatero CucsTrigTrigState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.1.1.27 |
cucsCpmaintAckPropAclro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.93.1.1.28 |
cucsCpmaintMaintPolicyTable SEQUENCE OF CucsCpmaintMaintPolicyEntry .1.3.6.1.4.1.9.9.719.1.93.2 |
cucsCpmaintMaintPolicyEntry CucsCpmaintMaintPolicyEntry .1.3.6.1.4.1.9.9.719.1.93.2.1 |
cucsCpmaintMaintPolicyInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.93.2.1.1 |
cucsCpmaintMaintPolicyDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.93.2.1.2 |
cucsCpmaintMaintPolicyRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.2.1.3 |
cucsCpmaintMaintPolicyDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.2.1.4 |
cucsCpmaintMaintPolicyIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.2.1.5 |
cucsCpmaintMaintPolicyNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.2.1.6 |
cucsCpmaintMaintPolicyOperSchedNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.2.1.7 |
cucsCpmaintMaintPolicyPolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.93.2.1.8 |
cucsCpmaintMaintPolicyPolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.2.1.9 |
cucsCpmaintMaintPolicySchedNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.93.2.1.10 |
cucsCpmaintMaintPolicyTriggerConfigro CucsTrigTrigger (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.2.1.11 |
cucsCpmaintMaintPolicyUptimeDisrro CucsTrigChassisAckMode (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.93.2.1.12 |
CISCO-UNIFIED-COMPUTING-CPMAINT-MIB Technical Reference Overview
The CISCO-UNIFIED-COMPUTING-CPMAINT-MIB SNMP MIB module published by Cisco defines 45 managed OID objects, including 40 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.719.1.93. Key tabular structures include cucsCpmaintAckTable, cucsCpmaintMaintPolicyTable.
Key OID Definitions in CISCO-UNIFIED-COMPUTING-CPMAINT-MIB
.1.3.6.1.4.1.9.9.719.1.93MIB representation of the Cisco Unified Computing System CPMAINT management information model package
.1.3.6.1.4.1.9.9.719.1.93.1Cisco UCS cpmaint:Ack managed object table
.1.3.6.1.4.1.9.9.719.1.93.2Cisco UCS cpmaint:MaintPolicy managed object table
.1.3.6.1.4.1.9.9.719.1.93.1.1Entry for the cucsCpmaintAckTable table.
.1.3.6.1.4.1.9.9.719.1.93.1.1.1Instance identifier of the managed object.
.1.3.6.1.4.1.9.9.719.1.93.1.1.2Cisco UCS cpmaint:Ack:dn managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.3Cisco UCS cpmaint:Ack:rn managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.4Cisco UCS cpmaint:Ack:acked managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.5Cisco UCS cpmaint:Ack:ackedBy managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.6Cisco UCS cpmaint:Ack:adminState managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.7Cisco UCS cpmaint:Ack:autoDelete managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.8Cisco UCS cpmaint:Ack:changeBy managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.9Cisco UCS cpmaint:Ack:changeDetails managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.10Cisco UCS cpmaint:Ack:changeMode managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.11Cisco UCS cpmaint:Ack:changes managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.12Cisco UCS cpmaint:Ack:configIssues managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.13Cisco UCS cpmaint:Ack:deploymentMode managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.14Cisco UCS cpmaint:Ack:descr managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.15Cisco UCS cpmaint:Ack:disr managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.16Cisco UCS cpmaint:Ack:ignoreCap managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.17Cisco UCS cpmaint:Ack:intId managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.18Cisco UCS cpmaint:Ack:modified managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.19Cisco UCS cpmaint:Ack:name managed object property
.1.3.6.1.4.1.9.9.719.1.93.1.1.20Cisco UCS cpmaint:Ack:oldChassisDn managed object property
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.