Home/Catalog/CISCO-UNIFIED-COMPUTING-CPMAINT-MIB

CISCO-UNIFIED-COMPUTING-CPMAINT-MIB

AI MIB Summary

The CISCO-UNIFIED-COMPUTING-CPMAINT-MIB enables SNMP-based monitoring and management of maintenance-related status, fault conditions, and operational events within the Cisco Unified Computing System (UCS) chassis and blade server infrastructure. This module specifically tracks CPMAINT (Chassis Platform Maintenance) state transitions, hardware component health, and scheduled maintenance window indicators to facilitate proactive infrastructure reliability.

MIB representation of the Cisco Unified Computing System CPMAINT management information model package
Main OID:
cucsCpmaintObjects.1.3.6.1.4.1.9.9.719.1.93
45
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

45 total
Object Name
cucsCpmaintObjects
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.719.1.93
cucsCpmaintAckTable
SEQUENCE OF CucsCpmaintAckEntry
.1.3.6.1.4.1.9.9.719.1.93.1
cucsCpmaintAckEntry
CucsCpmaintAckEntry
.1.3.6.1.4.1.9.9.719.1.93.1.1
cucsCpmaintAckInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.1
cucsCpmaintAckDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.2
cucsCpmaintAckRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.3
cucsCpmaintAckAckedro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.93.1.1.4
cucsCpmaintAckAckedByro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.5
cucsCpmaintAckAdminStatero
CucsTrigAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.6
cucsCpmaintAckAutoDeletero
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.93.1.1.7
cucsCpmaintAckChangeByro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.8
cucsCpmaintAckChangeDetailsro
CucsCpmaintAckChangeDetails (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.9
cucsCpmaintAckChangeModero
CucsCpmaintChangeMode (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.10
cucsCpmaintAckChangesro
CucsCpmaintAckChanges (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.11
cucsCpmaintAckConfigIssuesro
CucsEquipmentChassisConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.12
cucsCpmaintAckDeploymentModero
CucsTrigChassisAckMode (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.13
cucsCpmaintAckDescrro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.14
cucsCpmaintAckDisrro
CucsCpmaintAckDisr (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.15
cucsCpmaintAckIgnoreCapro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.93.1.1.16
cucsCpmaintAckIntIdro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.17
cucsCpmaintAckModifiedro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.93.1.1.18
cucsCpmaintAckNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.19
cucsCpmaintAckOldChassisDnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.20
cucsCpmaintAckOperSchedulerro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.21
cucsCpmaintAckOperStatero
CucsTrigAckOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.22
cucsCpmaintAckPolicyLevelro
Gauge32
.1.3.6.1.4.1.9.9.719.1.93.1.1.23
cucsCpmaintAckPolicyOwnerro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.24
cucsCpmaintAckPrevOperStatero
CucsTrigAckPrevOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.25
cucsCpmaintAckSchedulerro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.26
cucsCpmaintAckTriggerConfigStatero
CucsTrigTrigState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.1.1.27
cucsCpmaintAckPropAclro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.93.1.1.28
cucsCpmaintMaintPolicyTable
SEQUENCE OF CucsCpmaintMaintPolicyEntry
.1.3.6.1.4.1.9.9.719.1.93.2
cucsCpmaintMaintPolicyEntry
CucsCpmaintMaintPolicyEntry
.1.3.6.1.4.1.9.9.719.1.93.2.1
cucsCpmaintMaintPolicyInstanceId
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.93.2.1.1
cucsCpmaintMaintPolicyDnro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.93.2.1.2
cucsCpmaintMaintPolicyRnro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.2.1.3
cucsCpmaintMaintPolicyDescrro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.2.1.4
cucsCpmaintMaintPolicyIntIdro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.2.1.5
cucsCpmaintMaintPolicyNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.2.1.6
cucsCpmaintMaintPolicyOperSchedNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.2.1.7
cucsCpmaintMaintPolicyPolicyLevelro
Gauge32
.1.3.6.1.4.1.9.9.719.1.93.2.1.8
cucsCpmaintMaintPolicyPolicyOwnerro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.2.1.9
cucsCpmaintMaintPolicySchedNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.93.2.1.10
cucsCpmaintMaintPolicyTriggerConfigro
CucsTrigTrigger (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.2.1.11
cucsCpmaintMaintPolicyUptimeDisrro
CucsTrigChassisAckMode (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.93.2.1.12

CISCO-UNIFIED-COMPUTING-CPMAINT-MIB Technical Reference Overview

The CISCO-UNIFIED-COMPUTING-CPMAINT-MIB SNMP MIB module published by Cisco defines 45 managed OID objects, including 40 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.719.1.93. Key tabular structures include cucsCpmaintAckTable, cucsCpmaintMaintPolicyTable.

Key OID Definitions in CISCO-UNIFIED-COMPUTING-CPMAINT-MIB

cucsCpmaintObjectsMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.719.1.93

MIB representation of the Cisco Unified Computing System CPMAINT management information model package

cucsCpmaintAckTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.93.1

Cisco UCS cpmaint:Ack managed object table

cucsCpmaintMaintPolicyTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.719.1.93.2

Cisco UCS cpmaint:MaintPolicy managed object table

cucsCpmaintAckEntryCucsCpmaintAckEntrynot-accessible
.1.3.6.1.4.1.9.9.719.1.93.1.1

Entry for the cucsCpmaintAckTable table.

cucsCpmaintAckInstanceIdCucsManagedObjectIdnot-accessible
.1.3.6.1.4.1.9.9.719.1.93.1.1.1

Instance identifier of the managed object.

cucsCpmaintAckDnCucsManagedObjectDnread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.2

Cisco UCS cpmaint:Ack:dn managed object property

cucsCpmaintAckRnSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.3

Cisco UCS cpmaint:Ack:rn managed object property

cucsCpmaintAckAckedDateAndTimeread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.4

Cisco UCS cpmaint:Ack:acked managed object property

cucsCpmaintAckAckedBySnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.5

Cisco UCS cpmaint:Ack:ackedBy managed object property

cucsCpmaintAckAdminStateCucsTrigAdminStateread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.6

Cisco UCS cpmaint:Ack:adminState managed object property

cucsCpmaintAckAutoDeleteTruthValueread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.7

Cisco UCS cpmaint:Ack:autoDelete managed object property

cucsCpmaintAckChangeBySnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.8

Cisco UCS cpmaint:Ack:changeBy managed object property

cucsCpmaintAckChangeDetailsCucsCpmaintAckChangeDetailsread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.9

Cisco UCS cpmaint:Ack:changeDetails managed object property

cucsCpmaintAckChangeModeCucsCpmaintChangeModeread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.10

Cisco UCS cpmaint:Ack:changeMode managed object property

cucsCpmaintAckChangesCucsCpmaintAckChangesread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.11

Cisco UCS cpmaint:Ack:changes managed object property

cucsCpmaintAckConfigIssuesCucsEquipmentChassisConfigIssuesread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.12

Cisco UCS cpmaint:Ack:configIssues managed object property

cucsCpmaintAckDeploymentModeCucsTrigChassisAckModeread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.13

Cisco UCS cpmaint:Ack:deploymentMode managed object property

cucsCpmaintAckDescrSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.14

Cisco UCS cpmaint:Ack:descr managed object property

cucsCpmaintAckDisrCucsCpmaintAckDisrread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.15

Cisco UCS cpmaint:Ack:disr managed object property

cucsCpmaintAckIgnoreCapTruthValueread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.16

Cisco UCS cpmaint:Ack:ignoreCap managed object property

cucsCpmaintAckIntIdSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.17

Cisco UCS cpmaint:Ack:intId managed object property

cucsCpmaintAckModifiedDateAndTimeread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.18

Cisco UCS cpmaint:Ack:modified managed object property

cucsCpmaintAckNameSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.19

Cisco UCS cpmaint:Ack:name managed object property

cucsCpmaintAckOldChassisDnSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.719.1.93.1.1.20

Cisco UCS cpmaint:Ack:oldChassisDn managed object property

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→