CISCO-SWITCH-FABRIC-MIB
The CISCO-SWITCH-FABRIC-MIB enables SNMP-based monitoring of internal switching fabric topology, link states, and port aggregation metrics on Cisco Catalyst and Nexus switches. It provides granular visibility into fabric-specific counters and status indicators required for troubleshooting high-speed data plane connectivity and hardware-level switching anomalies.
Imported Objects
Objects
25 total| Object Name |
|---|
ciscoSwitchFabricMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.803 |
ciscoSwitchFabricMIBNotifs OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.803.0 |
csfFabricCrcErrorNotif NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.803.0.1 |
ciscoSwitchFabricMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.803.1 |
csfFabricStatistics OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.803.1.1 |
csfFabricUtilTable SEQUENCE OF CsfFabricUtilEntry .1.3.6.1.4.1.9.9.803.1.1.1 |
csfFabricUtilEntry CsfFabricUtilEntry .1.3.6.1.4.1.9.9.803.1.1.1.1 |
csfFabricUtilLinkType CsfFabricLinkType .1.3.6.1.4.1.9.9.803.1.1.1.1.1 |
csfFabricUtilIndex Unsigned32 .1.3.6.1.4.1.9.9.803.1.1.1.1.2 |
csfFabricUtilDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.803.1.1.1.1.3 |
csfFabricUtilBandwidthro Unsigned32 UNITS "gigabits per second" .1.3.6.1.4.1.9.9.803.1.1.1.1.4 |
csfFabricUtilInro CsfPercentOrMinusOne .1.3.6.1.4.1.9.9.803.1.1.1.1.5 |
csfFabricUtilInPeakro CsfPercentOrMinusOne .1.3.6.1.4.1.9.9.803.1.1.1.1.6 |
csfFabricUtilInPeakTimero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.803.1.1.1.1.7 |
csfFabricUtilOutro CsfPercentOrMinusOne .1.3.6.1.4.1.9.9.803.1.1.1.1.8 |
csfFabricUtilOutPeakro CsfPercentOrMinusOne .1.3.6.1.4.1.9.9.803.1.1.1.1.9 |
csfFabricUtilOutPeakTimero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.803.1.1.1.1.10 |
csfNotifsControl OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.803.1.2 |
csfFabricCrcErrorNotifEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.803.1.2.1 |
csfNotifsOnlyInfo OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.803.1.3 |
csfFabricCrcErrorEntPhysicalIndexro PhysicalIndex (ENTITY-MIB) .1.3.6.1.4.1.9.9.803.1.3.1 |
csfFabricCrcErrorDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.803.1.3.2 |
ciscoSwitchFabricMIBConform OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.803.2 |
csfSwitchFabricMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.803.2.1 |
csfSwitchFabricMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.803.2.2 |
CISCO-SWITCH-FABRIC-MIB Technical Reference Overview
The CISCO-SWITCH-FABRIC-MIB SNMP MIB module published by Cisco defines 25 managed OID objects, including 13 scalar/column metrics, 1 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.803. Key tabular structures include csfFabricUtilTable. Monitored SNMP traps/notifications include csfFabricCrcErrorNotif.
Key OID Definitions in CISCO-SWITCH-FABRIC-MIB
.1.3.6.1.4.1.9.9.803This MIB module defined managed objects that facilitates the management of switching fabric information in a Cisco switch.
.1.3.6.1.4.1.9.9.803.1.1.1A table containing fabric utilization information.
.1.3.6.1.4.1.9.9.803.0.1A cfsFabricCrcErrorNotif is generated when fabric CRC errors are detected by the managed system.
.1.3.6.1.4.1.9.9.803.1.2.1This object specifies whether the system generates the cfsFabricCrcErrorNotif. A value of 'false' will prevent cfsFabricCrcErrorNotif notifications from being generated by this system.
.1.3.6.1.4.1.9.9.803.1.3.1This object indicates the entPhysicalIndex of the fabric entity on which fabric CRC error happens.
.1.3.6.1.4.1.9.9.803.1.3.2This object indicates the fabric CRC error description. A zero-length string indicates that the error description is not available.
.1.3.6.1.4.1.9.9.803.1.1.1.1A conceptual row containing the fabric utilization information for a particular type of traffic utilization of a fabric entity. An entry of this table is created if a traffic utilization on a fabric entity is detected by the managed system. An entry of this table is deleted when the removal of fabric entity.
.1.3.6.1.4.1.9.9.803.1.1.1.1.1This object indicates the type of fabric link on which fabric traffic utilization is monitored.
.1.3.6.1.4.1.9.9.803.1.1.1.1.2This object indicates an arbitrary integer value which uniquely identifies the type of traffic utilization.
.1.3.6.1.4.1.9.9.803.1.1.1.1.3This object indicates the human-readable description of the type of fabric traffic utilization.
.1.3.6.1.4.1.9.9.803.1.1.1.1.4This object indicates the bandwidth of the fabric link.
.1.3.6.1.4.1.9.9.803.1.1.1.1.5This object indicates the utilization on the fabric link input.
.1.3.6.1.4.1.9.9.803.1.1.1.1.6This object indicates the peak utilization on the fabric link input.
.1.3.6.1.4.1.9.9.803.1.1.1.1.7This object indicates the time of the most recent change in the corresponding instance value of csfFabricUtilInPeak. This object contains value 0x0000010100000000 when the corresponding instance value of csfFabricUtilInPeak is '0 or '-1'.
.1.3.6.1.4.1.9.9.803.1.1.1.1.8This object indicates the utilization on the fabric link output.
.1.3.6.1.4.1.9.9.803.1.1.1.1.9This object indicates the peak utilization on the fabric link output.
.1.3.6.1.4.1.9.9.803.1.1.1.1.10This object indicates the time of the most recent change in the corresponding instance value of csfFabricUtilOutPeak. This object contains value 0x0000010100000000 when the corresponding instance value of csfFabricUtilInPeak is '0 or '-1'.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.