CISCO-SSG-MIB
The CISCO-SSG-MIB provides SNMP management capabilities for Cisco Service Selection Gateway (SSG) devices, enabling the monitoring of subscriber session states, broadband access link metrics, and the operational status of associated Service Selection Dashboard (SSD) and Subscriber Edge Service Manager (SESM) components. This module facilitates the tracking of GGSN and APN configurations to ensure reliable simultaneous intranet, extranet, and Internet connectivity for subscribers over DSL, cable, or wireless access technologies.
Imported Objects
Objects
154 total| Object Name |
|---|
ciscoSsgMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.260 |
ciscoSsgMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.260.0 |
ciscoSsgRadiusClientReboot NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.260.0.1 |
ciscoSsgRadiusAAAServerDown NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.260.0.2 |
ciscoSsgMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.260.1 |
cssgCfgObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.260.1.1 |
cssgCfgSsgEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.1 |
cssgCfgAutoDomainModerw Enumeration .1.3.6.1.4.1.9.9.260.1.1.2 |
cssgCfgLocalForwardingEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.3 |
cssgCfgAutoLogOffModerw Enumeration .1.3.6.1.4.1.9.9.260.1.1.4 |
cssgCfgRadiusProxyEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.5 |
cssgCfgTcpRedirectEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.6 |
cssgCfgAutoDomainNatEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.7 |
cssgCfgPortBundleHostKeyEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.8 |
cssgCfgTransPassThroughEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.9 |
cssgCfgAutoLogOffIntervalrw TimeInterval (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.10 |
cssgCfgAutoLogOffIcmpRetriesrw Unsigned32 .1.3.6.1.4.1.9.9.260.1.1.11 |
cssgCfgMaxServicesPerUserrw Unsigned32 .1.3.6.1.4.1.9.9.260.1.1.12 |
cssgCfgAccountingEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.13 |
cssgCfgDefaultNetworkTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.1.14 |
cssgCfgDefaultNetworkrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.1.15 |
cssgCfgRadiusAuthenPortrw CiscoPort (CISCO-TC) .1.3.6.1.4.1.9.9.260.1.1.16 |
cssgCfgRadiusAccountingPortrw CiscoPort (CISCO-TC) .1.3.6.1.4.1.9.9.260.1.1.17 |
cssgCfgRadiusFwdAcctPktsEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.18 |
cssgCfgAccountingIntervalrw Unsigned32 .1.3.6.1.4.1.9.9.260.1.1.19 |
cssgCfgTCPRedirGrpForUnAuthUsersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.20 |
cssgCfgTCPRedirGrpForUnAuthServrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.21 |
cssgCfgTcpRedirGrpForSMTPrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.22 |
cssgCfgTcpRedirGrpForInitialCaptrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.23 |
cssgCfgTcpRedirGrpForAdvCaptrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.24 |
cssgCfgRadiusClntRbtNotifEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.25 |
cssgCfgAAAServerDownNotifEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.26 |
cssgCfgTalEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.1.27 |
cssgStatsObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.260.1.2 |
cssgStatsLoginAttemptsro Counter32 .1.3.6.1.4.1.9.9.260.1.2.1 |
cssgStatsLoginsSuccessfulro Counter32 .1.3.6.1.4.1.9.9.260.1.2.2 |
cssgStatsActiveSessionsro Gauge32 .1.3.6.1.4.1.9.9.260.1.2.3 |
cssgStatsActiveHostsro Gauge32 .1.3.6.1.4.1.9.9.260.1.2.4 |
cssgStatsActiveServicesro Gauge32 .1.3.6.1.4.1.9.9.260.1.2.5 |
cssgStatsPODsro Counter32 .1.3.6.1.4.1.9.9.260.1.2.6 |
cssgService OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.260.1.3 |
cssgServiceTable SEQUENCE OF CssgServiceEntry .1.3.6.1.4.1.9.9.260.1.3.1 |
cssgServiceEntry CssgServiceEntry .1.3.6.1.4.1.9.9.260.1.3.1.1 |
cssgServiceName DisplayString .1.3.6.1.4.1.9.9.260.1.3.1.1.1 |
cssgServiceModero Enumeration .1.3.6.1.4.1.9.9.260.1.3.1.1.2 |
cssgServiceTypero Enumeration .1.3.6.1.4.1.9.9.260.1.3.1.1.3 |
cssgServiceIdleTimeoutro Unsigned32 UNITS "seconds" .1.3.6.1.4.1.9.9.260.1.3.1.1.4 |
cssgServiceSessionTimeoutro Unsigned32 UNITS "seconds" .1.3.6.1.4.1.9.9.260.1.3.1.1.5 |
cssgServiceActiveSessionsro Gauge32 .1.3.6.1.4.1.9.9.260.1.3.1.1.6 |
cssgServiceDNSPrimaryIpTypero InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.3.1.1.7 |
cssgServiceDNSPrimaryro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.3.1.1.8 |
cssgServiceDNSSecondaryIpTypero InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.3.1.1.9 |
cssgServiceDNSSecondaryro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.3.1.1.10 |
cssgServiceUpstreamQOSEnabledro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.3.1.1.11 |
cssgServiceDownStreamQOSEnabledro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.3.1.1.12 |
cssgServiceOpenGardenro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.3.1.1.13 |
cssgServicePrepaidro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.3.1.1.14 |
cssgServiceRouteTable SEQUENCE OF CssgServiceRouteEntry .1.3.6.1.4.1.9.9.260.1.3.2 |
cssgServiceRouteEntry CssgServiceRouteEntry .1.3.6.1.4.1.9.9.260.1.3.2.1 |
cssgServiceRouteType InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.3.2.1.1 |
cssgServiceRouteAddr InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.3.2.1.2 |
cssgServiceRouteMaskType InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.3.2.1.3 |
cssgServiceRouteMask InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.3.2.1.4 |
cssgServiceRoutePermissionro Enumeration .1.3.6.1.4.1.9.9.260.1.3.2.1.5 |
cssgExcludedAPN OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.260.1.4 |
cssgExcludedAPNTable SEQUENCE OF CssgExcludedAPNEntry .1.3.6.1.4.1.9.9.260.1.4.1 |
cssgExcludedAPNEntry CssgExcludedAPNEntry .1.3.6.1.4.1.9.9.260.1.4.1.1 |
cssgExcludedAPNName DisplayString .1.3.6.1.4.1.9.9.260.1.4.1.1.1 |
cssgExcludedAPNRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.4.1.1.2 |
cssgExcludedDomain OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.260.1.5 |
cssgExcludedDomainTable SEQUENCE OF CssgExcludedDomainEntry .1.3.6.1.4.1.9.9.260.1.5.1 |
cssgExcludedDomainEntry CssgExcludedDomainEntry .1.3.6.1.4.1.9.9.260.1.5.1.1 |
cssgExcludedDomainName DisplayString .1.3.6.1.4.1.9.9.260.1.5.1.1.1 |
cssgExcludedDomainRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.5.1.1.2 |
cssgTcpRedirect OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.260.1.6 |
cssgTcpRedirectGrpTable SEQUENCE OF CssgTcpRedirectGrpEntry .1.3.6.1.4.1.9.9.260.1.6.1 |
cssgTcpRedirectGrpEntry CssgTcpRedirectGrpEntry .1.3.6.1.4.1.9.9.260.1.6.1.1 |
cssgTcpRedirectGrpName DisplayString .1.3.6.1.4.1.9.9.260.1.6.1.1.1 |
cssgTcpRedirectGrpServerAddrType InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.6.1.1.2 |
cssgTcpRedirectGrpServerAddr InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.6.1.1.3 |
cssgTcpRedirectGrpServerPort CiscoPort (CISCO-TC) .1.3.6.1.4.1.9.9.260.1.6.1.1.4 |
cssgTcpRedirectGrpRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.6.1.1.5 |
cssgNetworkGrpTable SEQUENCE OF CssgNetworkGrpEntry .1.3.6.1.4.1.9.9.260.1.6.2 |
cssgNetworkGrpEntry CssgNetworkGrpEntry .1.3.6.1.4.1.9.9.260.1.6.2.1 |
cssgNetworkGrpName DisplayString .1.3.6.1.4.1.9.9.260.1.6.2.1.1 |
cssgNetworkGrpNetIpType InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.6.2.1.2 |
cssgNetworkGrpNetIpAddr InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.6.2.1.3 |
cssgNetworkGrpNetMaskType InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.6.2.1.4 |
cssgNetworkGrpNetMask InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.260.1.6.2.1.5 |
cssgNetworkGrpNetRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.6.2.1.6 |
cssgPortGrpTable SEQUENCE OF CssgPortGrpEntry .1.3.6.1.4.1.9.9.260.1.6.3 |
cssgPortGrpEntry CssgPortGrpEntry .1.3.6.1.4.1.9.9.260.1.6.3.1 |
cssgPortGrpName DisplayString .1.3.6.1.4.1.9.9.260.1.6.3.1.1 |
cssgPortGrpPortNo CiscoPort (CISCO-TC) .1.3.6.1.4.1.9.9.260.1.6.3.1.2 |
cssgPortGrpPortRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.6.3.1.3 |
cssgTcpRedirNetworkGrpMapTable SEQUENCE OF CssgTcpRedirNetworkGrpMapEntry .1.3.6.1.4.1.9.9.260.1.6.4 |
cssgTcpRedirNetworkGrpMapEntry CssgTcpRedirNetworkGrpMapEntry .1.3.6.1.4.1.9.9.260.1.6.4.1 |
cssgTcpRedirNetworkMapGrpNamerw DisplayString .1.3.6.1.4.1.9.9.260.1.6.4.1.1 |
cssgTcpRedirNetworkGrpMapRowStatrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.260.1.6.4.1.2 |
cssgTcpRedirPortGrpMapTable SEQUENCE OF CssgTcpRedirPortGrpMapEntry .1.3.6.1.4.1.9.9.260.1.6.5 |
CISCO-SSG-MIB Technical Reference Overview
The CISCO-SSG-MIB SNMP MIB module published by Cisco defines 154 managed OID objects, including 108 scalar/column metrics, 14 SNMP tables, and 2 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.260. Key tabular structures include cssgServiceTable, cssgServiceRouteTable, cssgExcludedAPNTable, cssgExcludedDomainTable, cssgServiceIfBindTable, cssgTcpRedirectGrpTable. Monitored SNMP traps/notifications include ciscoSsgRadiusClientReboot, ciscoSsgRadiusAAAServerDown.
Key OID Definitions in CISCO-SSG-MIB
.1.3.6.1.4.1.9.9.260The MIB Module manages Service Selection Gateway(SSG) devices. Service Selection Gateway(SSG) is a switching solution for service providers who offer intranet,extranet, and Internet connections to subscribers using broadband access technology such as digital subscriber lines, cable modems, or wireless to allow simultaneous access to network services. Acronyms and terms: SSD Service Selection Dashboard SESM Subscriber Edge Service Manager GGSN Gateway GPRS Support Node APN Access Point Name
.1.3.6.1.4.1.9.9.260.1.3.1A list of SSG Services which subscribers have logged onto. A Service entry in this table is transient data and gets removed when the last subscriber using this Service logs off.
.1.3.6.1.4.1.9.9.260.1.3.2A list of route entries that belong to a particular service.
.1.3.6.1.4.1.9.9.260.1.4.1A list of APNs excluded from using auto-main feature of SSG.
.1.3.6.1.4.1.9.9.260.1.5.1A list of Domain names excluded from using auto-domain feature of SSG.
.1.3.6.1.4.1.9.9.260.1.7.1In SSG, a Service can be configured to use a particular interface/ip address. This table is a list of services and the interface to which they are bound.
.1.3.6.1.4.1.9.9.260.1.6.1A list of TCP Redirect group. A TCP Redirect group is a list of one more servers that make up a captive portal group.
.1.3.6.1.4.1.9.9.260.1.6.2A list of network groups. When a network-group, a list of networks, associated with a TCP Redirect group, subscribers attempting to connect to these networks will be redirected to the TCP redirect group.
.1.3.6.1.4.1.9.9.260.1.6.3A list of port groups.
.1.3.6.1.4.1.9.9.260.1.6.4A list of Network and Server Group associations.
.1.3.6.1.4.1.9.9.260.1.6.5A list of Server and Port Group associations.
.1.3.6.1.4.1.9.9.260.1.6.6A list of Ports nos and the corresponding Server group which they are associated with.
.1.3.6.1.4.1.9.9.260.1.8.1A list of non-SSD clients to which SSG act as Radius proxy.
.1.3.6.1.4.1.9.9.260.1.9.2The list of TCP Port-maps.
.1.3.6.1.4.1.9.9.260.1.10.19A list of all the transparent users, along with their user-state.
.1.3.6.1.4.1.9.9.260.0.1The notification is sent when the connectivity to GGSN is lost.
.1.3.6.1.4.1.9.9.260.0.2The notification is sent when the connectivity to AAA is lost or when AAA Server is down.
.1.3.6.1.4.1.9.9.260.1.1.1An indication of whether SSG Service is enabled.
.1.3.6.1.4.1.9.9.260.1.1.2An indication of whether Auto-Domain feature is enabled. This feature allows a user to be automatically connected to a service based on the APN or structured username.
.1.3.6.1.4.1.9.9.260.1.1.3An indication of whether Local Forwarding is enabled. This feature enables SSG to forward packets locally between connected subscribers.
.1.3.6.1.4.1.9.9.260.1.1.4An indication of whether Auto Logoff feature is enabled. This feature enables SSG to initiate logoff if connectivity to a host is lost. Connectivity to a host is checked using ARP or ICMP ping mechanisms.
.1.3.6.1.4.1.9.9.260.1.1.5An indication of whether Radius-Proxy feature is enabled. This feature allows SSG to act as a generic Radius Proxy for non-SSD clients such as GGSN.
.1.3.6.1.4.1.9.9.260.1.1.6An indication of whether TCP redirect is enabled. This feature redirects certain TCP packets to captive portals.
.1.3.6.1.4.1.9.9.260.1.1.7An indication of whether NAT(Network Address Translation) is enabled for autodomain users. This feature determines whether the subscriber gets the autodomain service assigned IP Address.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.