The CISCO-SAN-BASE-SVC-MIB manages fault-tolerant service clusters on Cisco SAN switches, specifically monitoring the operational state and workload distribution of services like IO Acceleration (IOA) across Fibre Channel nodes identified by pWWN and Nx_port. It tracks cluster membership and failover status to ensure continuous service availability when a node within the switch cluster fails.

Common MIB module to manage services in Storage Area Network (SAN). Service is deployed on service nodes on multiple switches forming a cluster. Nodes in the same cluster pick up the workload of a failed node to provide fault tolerance. An example of service that can be deployed is IO Acceleration (IOA) service. Glossary: The following terms are used in this MIB: pWWN: Port World Wide Name is a identifier assigned to a port in a Fibre Channel fabric. They perform a function equivalent to the MAC address in Ethernet protocol, as it is supposed to be unique identifier in the network. Nx_port: Nx_port is a storage port in Fibre Channel fabric that belongs to host or target.
Main OID:
ciscoSanBaseSvcMIB.1.3.6.1.4.1.9.9.702
50
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

50 total
Object Name
ciscoSanBaseSvcMIBCommon MIB module to manage services in Storage Area Network (SAN). Service is deployed on service nodes on multiple switches forming a cluster. Nodes in the same cluster pick up the workload of a failed node to provide fault tolerance. An example of service that can be deployed is IO Acceleration (IOA) service. Glossary: The following terms are used in this MIB: pWWN: Port World Wide Name is a identifier assigned to a port in a Fibre Channel fabric. They perform a function equivalent to the MAC address in Ethernet protocol, as it is supposed to be unique identifier in the network. Nx_port: Nx_port is a storage port in Fibre Channel fabric that belongs to host or target.
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.702
ciscoSanBaseSvcMIBNotifs
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.0
ciscoSanBaseSvcInterfaceCreateThis notification is generated when a service interface associated with a local device is created. The generation of this notification is controlled by cSanBaseSvcNotifyEnable
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.702.0.1
ciscoSanBaseSvcInterfaceDeleteThis notification is generated when a service interface associated with a local device is deleted. The generation of this notification is controlled by cSanBaseSvcNotifyEnable
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.702.0.2
ciscoSanBaseSvcClusterNewMasterThis notification is generated when the sending device who is participating in a service cluster has transitioned to be the master of the cluster. The generation of this notification is controlled by cSanBaseSvcNotifyEnable
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.702.0.3
ciscoSanBaseSvcMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.1
cSanBaseSvcConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.1.1
cSanBaseSvcClusterTableThis table lists all the service clusters that are configured on this device. It is important that any service is provided in a fault-tolerant manner. Base Service provides this by allowing service nodes to be grouped into cluster. Nodes in the same cluster immediately pick up the work of any failed node so user does not see service disruption.
SEQUENCE OF CSanBaseSvcClusterEntry
.1.3.6.1.4.1.9.9.702.1.1.1
cSanBaseSvcClusterEntryA conceptual row in the cSanBaseSvcClusterTable. Each row represents a service cluster in the system and provides the runtime and configuration information of a cluster.
CSanBaseSvcClusterEntry
.1.3.6.1.4.1.9.9.702.1.1.1.1
cSanBaseSvcClusterIdGlobally unique index that identifies a service cluster. This index must be generated in such a way that the same value is never reused even after cluster has been deleted.
CiscoSanBaseSvcClusterIndex
.1.3.6.1.4.1.9.9.702.1.1.1.1.1
cSanBaseSvcClusterNameThe name of the service cluster.rw
SnmpAdminString
.1.3.6.1.4.1.9.9.702.1.1.1.1.2
cSanBaseSvcClusterStateThe operational state of the service cluster.ro
CiscoSanBaseSvcClusterStatus
.1.3.6.1.4.1.9.9.702.1.1.1.1.3
cSanBaseSvcClusterMasterInetAddrTypeThe type of Internet address of the service cluster master. The Internet address of service cluster master is specified by the value of the corresponding instance of cSanBaseSvcClusterMasterInetAddr.ro
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.702.1.1.1.1.4
cSanBaseSvcClusterMasterInetAddrThe Internet address of the service cluster master device. The type of this Internet address is determined by the value of the corresponding instance of cSanBaseSvcClusterMasterInetAddrType.ro
InetAddress (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.702.1.1.1.1.5
cSanBaseSvcClusterStorageTypeThis object specifies the storage type for this conceptual row.rw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.1.1.6
cSanBaseSvcClusterRowStatusThe status of this conceptual row. There is no restriction on the value of other columns before a newly created row can be made active.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.1.1.7
cSanBaseSvcClusterApplicationThis object represents the name of the application that is enabled on this cluster.rw
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.702.1.1.1.1.8
cSanBaseSvcClusterMembersTableThis table lists the information of devices, local or remote, which are members of a service cluster configured on a device.
SEQUENCE OF CSanBaseSvcClusterMembersEntry
.1.3.6.1.4.1.9.9.702.1.1.2
cSanBaseSvcClusterMembersEntryA conceptual row in the cSanBaseSvcClusterMembersTable. Each row represents a member device within a specified service Cluster.
CSanBaseSvcClusterMembersEntry
.1.3.6.1.4.1.9.9.702.1.1.2.1
cSanBaseSvcClusterMemberInetAddrTypeThe type of Internet address of a cluster member within a specified service cluster. The Internet address of this device is specified by the value of the corresponding instance of cSanBaseSvcMemberInetAddr.
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.702.1.1.2.1.1
cSanBaseSvcClusterMemberInetAddrThe Internet address of the cluster member device within a specified service cluster. The type of this Internet address is determined by the value of the corresponding instance of cSanBaseSvcClusterMemberInetAddrType.
InetAddress
.1.3.6.1.4.1.9.9.702.1.1.2.1.2
cSanBaseSvcClusterMemberFabricThis object represents the name of the physical fibre channel fabric in the SAN. A typical SAN deployment consists of a dual fabric topology which corresponds to two physical fabrics. In such a deployment, a cluster is configured in both fabrics to allow multi-pathing and redundancy. The user specifies the physical fabric to which a device belongs to when the cluster is configured.rw
SnmpAdminString
.1.3.6.1.4.1.9.9.702.1.1.2.1.3
cSanBaseSvcClusterMemberIsLocalIdentifies if the device is a local or remote member of this cluster. 'true' means this device is a local device. 'false' means this device is a remote device.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.2.1.4
cSanBaseSvcClusterMemberIsMasterIndicates if this device is currently the master of the service cluster. The value 'true' means this device is the master. The value 'false' means this device is not the master. Devices in a cluster select one of the cluster member to be a master. The master is responsible for handling cluster membership.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.2.1.5
cSanBaseSvcClusterMemberStorageTypeThis object specifies the storage type for this conceptual row.rw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.2.1.6
cSanBaseSvcClusterMemberRowStatusThe status of this conceptual row. There is no restriction on the value of other columns before a newly created row can be made active. When a cluster is deleted, all entries in this table should be purged automatically.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.2.1.7
cSanBaseSvcInterfaceTableThis table lists all service interfaces on the local device and its corresponding information.
SEQUENCE OF CSanBaseSvcInterfaceEntry
.1.3.6.1.4.1.9.9.702.1.1.3
cSanBaseSvcInterfaceEntryA conceptual row in the cSanBaseSvcInterfaceTable. Each row represents a particular service interface on a local device.
CSanBaseSvcInterfaceEntry
.1.3.6.1.4.1.9.9.702.1.1.3.1
cSanBaseSvcInterfaceIndexA unique Interface index for a service interface on this device. This is the same as ifIndex of the ifTable of RFC1213.
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.9.9.702.1.1.3.1.1
cSanBaseSvcInterfaceStateOperational state of this service interface.ro
CiscoSanBaseSvcInterfaceStatus
.1.3.6.1.4.1.9.9.702.1.1.3.1.2
cSanBaseSvcInterfaceClusterIdIdentifies the cluster to which this service interface belongs.rw
CiscoSanBaseSvcClusterIndex
.1.3.6.1.4.1.9.9.702.1.1.3.1.3
cSanBaseSvcInterfaceStorageTypeThis object specifies the storage type for this conceptual row.rw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.3.1.4
cSanBaseSvcInterfaceRowStatusThe status of this conceptual row. There is no restriction on the value of other columns before a newly created row can be made active. For example, cSanBaseSvcInterfaceClusterId column can be set independently later.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.3.1.5
cSanBaseSvcDevicePortTableThis table lists the devices that are configured to receive storage service.
SEQUENCE OF CSanBaseSvcDevicePortEntry
.1.3.6.1.4.1.9.9.702.1.1.4
cSanBaseSvcDevicePortEntryA conceptual row in the cSanBaseSvcDevicePortTable. Each row represents a particular device configured to receive storage service in a particular cluster.
CSanBaseSvcDevicePortEntry
.1.3.6.1.4.1.9.9.702.1.1.4.1
cSanBaseSvcDevicePortNameThis object represents Fibre-channel Port name (pWWN) of the Device Nx_Port.
FcNameId (CISCO-ST-TC)
.1.3.6.1.4.1.9.9.702.1.1.4.1.1
cSanBaseSvcDevicePortClusterIdThis object represents the cluster identifier of the cluster to which this port belongs.rw
CiscoSanBaseSvcClusterIndex
.1.3.6.1.4.1.9.9.702.1.1.4.1.2
cSanBaseSvcDevicePortStorageTypeThis object specifies the storage type for this conceptual row.rw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.4.1.3
cSanBaseSvcDevicePortRowStatusThe status of this conceptual row. There is no restriction on the value of other columns before a newly created row can be made active.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.4.1.4
cSanBaseSvcConfigTableLastChangedThe value of sysUpTime when a change to any Base Service MIB table other than the cSanBaseSvcDevicePortTable last occurred.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.5
cSanBaseSvcDevicePortTableLastChangedThe value of sysUpTime when a change to cSanBaseSvcDevicePortTable last occurred.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.6
cSanBaseSvcNotifyEnableThis object specifies if the service notifications should be generated or not. If the value of this object is 'true', then the notifications are generated. If the value of this object is 'false', then the notifications are not generated.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.7
cSanBaseSvcInterface
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.1.2
cSanBaseSvcClusterMemberIfTableThis table lists the information of service interfaces on all devices, local or remote, which are members of a service cluster configured on a device.
SEQUENCE OF CSanBaseSvcClusterMemberIfEntry
.1.3.6.1.4.1.9.9.702.1.2.1
cSanBaseSvcClusterMemberIfEntryA conceptual row in the cSanBaseSvcClusterMemberIfTable. Each row represents a participating interface on local/remote device member within the specified service cluster.
CSanBaseSvcClusterMemberIfEntry
.1.3.6.1.4.1.9.9.702.1.2.1.1
cSanBaseSvcClusterInterfaceIndexA unique Interface index for a service interface on a device in this cluster. This is the same as ifIndex of the ifTable of RFC1213.
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.9.9.702.1.2.1.1.1
cSanBaseSvcClusterInterfaceStateThe operational state of this service interface.ro
CiscoSanBaseSvcInterfaceStatus
.1.3.6.1.4.1.9.9.702.1.2.1.1.2
ciscoSanBaseSvcMIBConform
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.2
ciscoSanBaseSvcMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.2.1
ciscoSanBaseSvcMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.2.2