CISCO-SAN-BASE-SVC-MIB

AI MIB Summary

The CISCO-SAN-BASE-SVC-MIB manages fault-tolerant service clusters on Cisco SAN switches, specifically monitoring the operational state and workload distribution of services like IO Acceleration (IOA) across Fibre Channel nodes identified by pWWN and Nx_port. It tracks cluster membership and failover status to ensure continuous service availability when a node within the switch cluster fails.

Common MIB module to manage services in Storage Area Network (SAN). Service is deployed on service nodes on multiple switches forming a cluster. Nodes in the same cluster pick up the workload of a failed node to provide fault tolerance. An example of service that can be deployed is IO Acceleration (IOA) service. Glossary: The following terms are used in this MIB: pWWN: Port World Wide Name is a identifier assigned to a port in a Fibre Channel fabric. They perform a function equivalent to the MAC address in Ethernet protocol, as it is supposed to be unique identifier in the network. Nx_port: Nx_port is a storage port in Fibre Channel fabric that belongs to host or target.
Main OID:
ciscoSanBaseSvcMIB.1.3.6.1.4.1.9.9.702
50
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

50 total
Object Name
ciscoSanBaseSvcMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.702
ciscoSanBaseSvcMIBNotifs
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.0
ciscoSanBaseSvcInterfaceCreate
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.702.0.1
ciscoSanBaseSvcInterfaceDelete
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.702.0.2
ciscoSanBaseSvcClusterNewMaster
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.702.0.3
ciscoSanBaseSvcMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.1
cSanBaseSvcConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.1.1
cSanBaseSvcClusterTable
SEQUENCE OF CSanBaseSvcClusterEntry
.1.3.6.1.4.1.9.9.702.1.1.1
cSanBaseSvcClusterEntry
CSanBaseSvcClusterEntry
.1.3.6.1.4.1.9.9.702.1.1.1.1
cSanBaseSvcClusterId
CiscoSanBaseSvcClusterIndex
.1.3.6.1.4.1.9.9.702.1.1.1.1.1
cSanBaseSvcClusterNamerw
SnmpAdminString
.1.3.6.1.4.1.9.9.702.1.1.1.1.2
cSanBaseSvcClusterStatero
CiscoSanBaseSvcClusterStatus
.1.3.6.1.4.1.9.9.702.1.1.1.1.3
cSanBaseSvcClusterMasterInetAddrTypero
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.702.1.1.1.1.4
cSanBaseSvcClusterMasterInetAddrro
InetAddress (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.702.1.1.1.1.5
cSanBaseSvcClusterStorageTyperw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.1.1.6
cSanBaseSvcClusterRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.1.1.7
cSanBaseSvcClusterApplicationrw
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.702.1.1.1.1.8
cSanBaseSvcClusterMembersTable
SEQUENCE OF CSanBaseSvcClusterMembersEntry
.1.3.6.1.4.1.9.9.702.1.1.2
cSanBaseSvcClusterMembersEntry
CSanBaseSvcClusterMembersEntry
.1.3.6.1.4.1.9.9.702.1.1.2.1
cSanBaseSvcClusterMemberInetAddrType
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.702.1.1.2.1.1
cSanBaseSvcClusterMemberInetAddr
InetAddress
.1.3.6.1.4.1.9.9.702.1.1.2.1.2
cSanBaseSvcClusterMemberFabricrw
SnmpAdminString
.1.3.6.1.4.1.9.9.702.1.1.2.1.3
cSanBaseSvcClusterMemberIsLocalro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.2.1.4
cSanBaseSvcClusterMemberIsMasterro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.2.1.5
cSanBaseSvcClusterMemberStorageTyperw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.2.1.6
cSanBaseSvcClusterMemberRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.2.1.7
cSanBaseSvcInterfaceTable
SEQUENCE OF CSanBaseSvcInterfaceEntry
.1.3.6.1.4.1.9.9.702.1.1.3
cSanBaseSvcInterfaceEntry
CSanBaseSvcInterfaceEntry
.1.3.6.1.4.1.9.9.702.1.1.3.1
cSanBaseSvcInterfaceIndex
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.9.9.702.1.1.3.1.1
cSanBaseSvcInterfaceStatero
CiscoSanBaseSvcInterfaceStatus
.1.3.6.1.4.1.9.9.702.1.1.3.1.2
cSanBaseSvcInterfaceClusterIdrw
CiscoSanBaseSvcClusterIndex
.1.3.6.1.4.1.9.9.702.1.1.3.1.3
cSanBaseSvcInterfaceStorageTyperw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.3.1.4
cSanBaseSvcInterfaceRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.3.1.5
cSanBaseSvcDevicePortTable
SEQUENCE OF CSanBaseSvcDevicePortEntry
.1.3.6.1.4.1.9.9.702.1.1.4
cSanBaseSvcDevicePortEntry
CSanBaseSvcDevicePortEntry
.1.3.6.1.4.1.9.9.702.1.1.4.1
cSanBaseSvcDevicePortName
FcNameId (CISCO-ST-TC)
.1.3.6.1.4.1.9.9.702.1.1.4.1.1
cSanBaseSvcDevicePortClusterIdrw
CiscoSanBaseSvcClusterIndex
.1.3.6.1.4.1.9.9.702.1.1.4.1.2
cSanBaseSvcDevicePortStorageTyperw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.4.1.3
cSanBaseSvcDevicePortRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.4.1.4
cSanBaseSvcConfigTableLastChangedro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.5
cSanBaseSvcDevicePortTableLastChangedro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.6
cSanBaseSvcNotifyEnablerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.702.1.1.7
cSanBaseSvcInterface
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.1.2
cSanBaseSvcClusterMemberIfTable
SEQUENCE OF CSanBaseSvcClusterMemberIfEntry
.1.3.6.1.4.1.9.9.702.1.2.1
cSanBaseSvcClusterMemberIfEntry
CSanBaseSvcClusterMemberIfEntry
.1.3.6.1.4.1.9.9.702.1.2.1.1
cSanBaseSvcClusterInterfaceIndex
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.9.9.702.1.2.1.1.1
cSanBaseSvcClusterInterfaceStatero
CiscoSanBaseSvcInterfaceStatus
.1.3.6.1.4.1.9.9.702.1.2.1.1.2
ciscoSanBaseSvcMIBConform
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.2
ciscoSanBaseSvcMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.2.1
ciscoSanBaseSvcMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.702.2.2

CISCO-SAN-BASE-SVC-MIB Technical Reference Overview

The CISCO-SAN-BASE-SVC-MIB SNMP MIB module published by Cisco defines 50 managed OID objects, including 29 scalar/column metrics, 5 SNMP tables, and 3 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.702. Key tabular structures include cSanBaseSvcClusterTable, cSanBaseSvcClusterMembersTable, cSanBaseSvcInterfaceTable, cSanBaseSvcDevicePortTable, cSanBaseSvcClusterMemberIfTable. Monitored SNMP traps/notifications include ciscoSanBaseSvcInterfaceCreate, ciscoSanBaseSvcInterfaceDelete, ciscoSanBaseSvcClusterNewMaster.

Key OID Definitions in CISCO-SAN-BASE-SVC-MIB

ciscoSanBaseSvcMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.702

Common MIB module to manage services in Storage Area Network (SAN). Service is deployed on service nodes on multiple switches forming a cluster. Nodes in the same cluster pick up the workload of a failed node to provide fault tolerance. An example of service that can be deployed is IO Acceleration (IOA) service. Glossary: The following terms are used in this MIB: pWWN: Port World Wide Name is a identifier assigned to a port in a Fibre Channel fabric. They perform a function equivalent to the MAC address in Ethernet protocol, as it is supposed to be unique identifier in the network. Nx_port: Nx_port is a storage port in Fibre Channel fabric that belongs to host or target.

cSanBaseSvcClusterTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.702.1.1.1

This table lists all the service clusters that are configured on this device. It is important that any service is provided in a fault-tolerant manner. Base Service provides this by allowing service nodes to be grouped into cluster. Nodes in the same cluster immediately pick up the work of any failed node so user does not see service disruption.

cSanBaseSvcClusterMembersTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.702.1.1.2

This table lists the information of devices, local or remote, which are members of a service cluster configured on a device.

cSanBaseSvcInterfaceTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.702.1.1.3

This table lists all service interfaces on the local device and its corresponding information.

cSanBaseSvcDevicePortTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.702.1.1.4

This table lists the devices that are configured to receive storage service.

cSanBaseSvcClusterMemberIfTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.702.1.2.1

This table lists the information of service interfaces on all devices, local or remote, which are members of a service cluster configured on a device.

ciscoSanBaseSvcInterfaceCreateNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.702.0.1

This notification is generated when a service interface associated with a local device is created. The generation of this notification is controlled by cSanBaseSvcNotifyEnable

ciscoSanBaseSvcInterfaceDeleteNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.702.0.2

This notification is generated when a service interface associated with a local device is deleted. The generation of this notification is controlled by cSanBaseSvcNotifyEnable

ciscoSanBaseSvcClusterNewMasterNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.702.0.3

This notification is generated when the sending device who is participating in a service cluster has transitioned to be the master of the cluster. The generation of this notification is controlled by cSanBaseSvcNotifyEnable

cSanBaseSvcConfigTableLastChangedTimeStampread-only
.1.3.6.1.4.1.9.9.702.1.1.5

The value of sysUpTime when a change to any Base Service MIB table other than the cSanBaseSvcDevicePortTable last occurred.

cSanBaseSvcDevicePortTableLastChangedTimeStampread-only
.1.3.6.1.4.1.9.9.702.1.1.6

The value of sysUpTime when a change to cSanBaseSvcDevicePortTable last occurred.

cSanBaseSvcNotifyEnableTruthValueread-write
.1.3.6.1.4.1.9.9.702.1.1.7

This object specifies if the service notifications should be generated or not. If the value of this object is 'true', then the notifications are generated. If the value of this object is 'false', then the notifications are not generated.

cSanBaseSvcClusterEntryCSanBaseSvcClusterEntrynot-accessible
.1.3.6.1.4.1.9.9.702.1.1.1.1

A conceptual row in the cSanBaseSvcClusterTable. Each row represents a service cluster in the system and provides the runtime and configuration information of a cluster.

cSanBaseSvcClusterIdCiscoSanBaseSvcClusterIndexnot-accessible
.1.3.6.1.4.1.9.9.702.1.1.1.1.1

Globally unique index that identifies a service cluster. This index must be generated in such a way that the same value is never reused even after cluster has been deleted.

cSanBaseSvcClusterNameSnmpAdminStringread-create
.1.3.6.1.4.1.9.9.702.1.1.1.1.2

The name of the service cluster.

cSanBaseSvcClusterStateCiscoSanBaseSvcClusterStatusread-only
.1.3.6.1.4.1.9.9.702.1.1.1.1.3

The operational state of the service cluster.

cSanBaseSvcClusterMasterInetAddrTypeInetAddressTyperead-only
.1.3.6.1.4.1.9.9.702.1.1.1.1.4

The type of Internet address of the service cluster master. The Internet address of service cluster master is specified by the value of the corresponding instance of cSanBaseSvcClusterMasterInetAddr.

cSanBaseSvcClusterMasterInetAddrInetAddressread-only
.1.3.6.1.4.1.9.9.702.1.1.1.1.5

The Internet address of the service cluster master device. The type of this Internet address is determined by the value of the corresponding instance of cSanBaseSvcClusterMasterInetAddrType.

cSanBaseSvcClusterStorageTypeStorageTyperead-create
.1.3.6.1.4.1.9.9.702.1.1.1.1.6

This object specifies the storage type for this conceptual row.

cSanBaseSvcClusterRowStatusRowStatusread-create
.1.3.6.1.4.1.9.9.702.1.1.1.1.7

The status of this conceptual row. There is no restriction on the value of other columns before a newly created row can be made active.

cSanBaseSvcClusterApplicationSnmpAdminStringread-create
.1.3.6.1.4.1.9.9.702.1.1.1.1.8

This object represents the name of the application that is enabled on this cluster.

cSanBaseSvcClusterMembersEntryCSanBaseSvcClusterMembersEntrynot-accessible
.1.3.6.1.4.1.9.9.702.1.1.2.1

A conceptual row in the cSanBaseSvcClusterMembersTable. Each row represents a member device within a specified service Cluster.

cSanBaseSvcClusterMemberInetAddrTypeInetAddressTypenot-accessible
.1.3.6.1.4.1.9.9.702.1.1.2.1.1

The type of Internet address of a cluster member within a specified service cluster. The Internet address of this device is specified by the value of the corresponding instance of cSanBaseSvcMemberInetAddr.

cSanBaseSvcClusterMemberInetAddrInetAddressnot-accessible
.1.3.6.1.4.1.9.9.702.1.1.2.1.2

The Internet address of the cluster member device within a specified service cluster. The type of this Internet address is determined by the value of the corresponding instance of cSanBaseSvcClusterMemberInetAddrType.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→