Home/Catalog/CISCO-RF-MIB

CISCO-RF-MIB

AI MIB Summary

The CISCO-RF-MIB manages the configuration and operational status of the Cisco Redundancy Framework (RF) subsystem to enforce 1:1 software redundancy on processor cards, specifically monitoring peer synchronization states and failover readiness to ensure carrier-grade availability. This module tracks logical redundancy metrics for software function duplication while explicitly excluding hardware components such as power supplies.

This MIB provides configuration control and status for the Redundancy Framework (RF) subsystem. RF provides a mechanism for logical redundancy of software functionality and is designed to support 1:1 redundancy on processor cards. RF is not intended to solve all redundancy schemes. Nor is RF designed to support redundant hardware, such as power supplies. Redundancy is concerned with the duplication of data elements and software functions to provide an alternative in case of failure. It is a key component to meeting 99.999% availability requirements for Class 5 carrier solutions. In the scope of this MIB definition, peer software elements are redundant and redundant software elements are peers.
Main OID:
ciscoRFMIB.1.3.6.1.4.1.9.9.176
66
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

66 total
Object Name
ciscoRFMIBThis MIB provides configuration control and status for the Redundancy Framework (RF) subsystem. RF provides a mechanism for logical redundancy of software functionality and is designed to support 1:1 redundancy on processor cards. RF is not intended to solve all redundancy schemes. Nor is RF designed to support redundant hardware, such as power supplies. Redundancy is concerned with the duplication of data elements and software functions to provide an alternative in case of failure. It is a key component to meeting 99.999% availability requirements for Class 5 carrier solutions. In the scope of this MIB definition, peer software elements are redundant and redundant software elements are peers.
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.176
ciscoRFMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.176.1
cRFStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.176.1.1
cRFStatusUnitIdA unique identifier for this redundant unit. This identifier is implementation-specific but the method for selecting the id must remain consistent throughout the redundant system. Some example identifiers include: slot id, physical or logical entity id, or a unique id assigned internally by the RF subsystem.ro
RFUnitIdentifier
.1.3.6.1.4.1.9.9.176.1.1.1
cRFStatusUnitStateThe current state of RF on this unit.ro
RFState
.1.3.6.1.4.1.9.9.176.1.1.2
cRFStatusPeerUnitIdA unique identifier for the redundant peer unit. This identifier is implementation-specific but the method for selecting the id must remain consistent throughout the redundant system. Some example identifiers include: slot id, physical or logical entity id, or a unique id assigned internally by the RF subsystem.ro
RFUnitIdentifier
.1.3.6.1.4.1.9.9.176.1.1.3
cRFStatusPeerUnitStateThe current state of RF on the peer unit.ro
RFState
.1.3.6.1.4.1.9.9.176.1.1.4
cRFStatusPrimaryModeIndicates whether this is the primary redundant unit or not. If this unit is the primary unit, this object is true. If this unit is the secondary unit, this object is false. Note that the terms 'primary/secondary' are not synonymous with the terms 'active/standby'. At any given time, the primary unit may be the active unit, or the primary unit may be the standby unit. Likewise, the secondary unit, at any given time, may be the active unit, or the secondary unit may be the standby unit. The primary unit is given a higher priority or precedence over the secondary unit. In a race condition (usually at initialization time) or any situation where the redundant units are unable to successfully negotiate activity between themselves, the primary unit will always become the active unit and the secondary unit will fall back to standby. Only one redundant unit can be the primary unit at any given time. The algorithm for determining the primary unit is system dependent, such as 'the redundant unit with the lower numeric unit id is always the primary unit.'ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.176.1.1.5
cRFStatusDuplexModeIndicates whether the redundant peer unit has been detected or not. If the redundant peer unit is detected, this object is true. If the redundant peer unit is not detected, this object is false.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.176.1.1.6
cRFStatusManualSwactInhibitIndicates whether a manual switch of activity is permitted. If a manual switch of activity is allowed, this object is false. If a manual switch of activity is not allowed, this object is true. Note that the value of this object is the inverse of the status of manual SWACTs. This object does not indicate whether a switch of activity is or has occurred. This object only indicates if the user-controllable capability is enabled or not. A switch of activity is the event in which the standby redundant unit becomes active and the previously active unit becomes standby.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.176.1.1.7
cRFStatusLastSwactReasonCodeThe reason for the last switch of activity.ro
RFSwactReasonType
.1.3.6.1.4.1.9.9.176.1.1.8
cRFStatusFailoverTimeThe value of sysUpTime when the primary redundant unit took over as active. The value of this object will be 0 till the first switchover.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.176.1.1.9
cRFStatusPeerStandByEntryTimeThe value of sysUpTime when the peer redundant unit entered the standbyHot state. The value will be 0 on system initialization.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.176.1.1.10
cRFStatusRFModeCapsTableThis table containing a list of redundancy modes that can be supported on the device.
SEQUENCE OF CRFStatusRFModeCapsEntry
.1.3.6.1.4.1.9.9.176.1.1.11
cRFStatusRFModeCapsEntryAn entry containing the device implementation specific terminology associated with the redundancy mode that can be supported on the device.
CRFStatusRFModeCapsEntry
.1.3.6.1.4.1.9.9.176.1.1.11.1
cRFStatusRFModeCapsModeThe redundancy mode that can be supported on the device.
RFMode
.1.3.6.1.4.1.9.9.176.1.1.11.1.1
cRFStatusRFModeCapsModeDescrThe description of the device implementation specific terminology associated with its supported redundancy mode.ro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.176.1.1.11.1.2
cRFStatusIssuStateThe current ISSU state of the system.rodeprecated
RFIssuState
.1.3.6.1.4.1.9.9.176.1.1.12
cRFStatusIssuStateRev1The current ISSU state of the system.ro
RFIssuStateRev1
.1.3.6.1.4.1.9.9.176.1.1.13
cRFStatusIssuFromVersionThe IOS version from with the user is upgradingro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.176.1.1.14
cRFStatusIssuToVersionThe IOS version to with the user is upgradingro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.176.1.1.15
cRFCfg
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.176.1.2
cRFCfgSplitModeIndicates whether redundant units may communicate synchronization messages with each other. If communication is not permitted, this object is set to true. If communication is permitted, this object is set to false. In split mode (true), the active unit will not communicate with the standby unit. The standby unit progression will not occur. When split mode is disabled (false), the standby unit is reset to recover. Split mode (true) is useful for maintenance operations.rwdeprecated
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.176.1.2.1
cRFCfgKeepaliveThreshOn platforms that support keep-alives, the keep-alive threshold value designates the number of lost keep-alives tolerated before a failure condition is declared. If this occurs, a SWACT notification is sent. On platforms that do not support keep-alives, this object has no purpose or effect.rw
Unsigned32
.1.3.6.1.4.1.9.9.176.1.2.2
cRFCfgKeepaliveThreshMinThe minimum acceptable value for the cRFCfgKeepaliveThresh object.ro
Unsigned32
.1.3.6.1.4.1.9.9.176.1.2.3
cRFCfgKeepaliveThreshMaxThe maximum acceptable value for the cRFCfgKeepaliveThresh object.ro
Unsigned32
.1.3.6.1.4.1.9.9.176.1.2.4
cRFCfgKeepaliveTimerOn platforms that support keep-alives, the keep-alive timer value is used to guard against lost keep-alives. The RF subsystem expects to receive a keep-alive within this period. If a keep-alive is not received within this time period, a SWACT notification is sent. On platforms that do not support keep-alives, this object has no purpose or effect.rw
Unsigned32 UNITS "milliseconds"
.1.3.6.1.4.1.9.9.176.1.2.5
cRFCfgKeepaliveTimerMinThe minimum acceptable value for the cRFCfgKeepaliveTimer object.ro
Unsigned32 UNITS "milliseconds"
.1.3.6.1.4.1.9.9.176.1.2.6
cRFCfgKeepaliveTimerMaxThe maximum acceptable value for the cRFCfgKeepaliveTimer object.ro
Unsigned32 UNITS "milliseconds"
.1.3.6.1.4.1.9.9.176.1.2.7
cRFCfgNotifTimerNote that the term 'notification' here refers to an RF notification and not an SNMP notification. As the standby unit progresses to the 'standbyHot' state, asynchronous messages are sent from the active unit to the standby unit which must then be acknowledged by the standby unit. If the active unit receives the acknowledgement during the time period specified by this object, progression proceeds as normal. If the timer expires and an acknowledgement was not received by the active unit, a switch of activity occurs.rw
Unsigned32 UNITS "milliseconds"
.1.3.6.1.4.1.9.9.176.1.2.8
cRFCfgNotifTimerMinThe minimum acceptable value for the cRFCfgNotifTimer object.ro
Unsigned32 UNITS "milliseconds"
.1.3.6.1.4.1.9.9.176.1.2.9
cRFCfgNotifTimerMaxThe maximum acceptable value for the cRFCfgNotifTimer object.ro
Unsigned32 UNITS "milliseconds"
.1.3.6.1.4.1.9.9.176.1.2.10
cRFCfgAdminActionThis variable is set to invoke RF subsystem action commands. The commands are useful for maintenance and software upgrade activities.rw
RFAction
.1.3.6.1.4.1.9.9.176.1.2.11
cRFCfgNotifsEnabledAllows enabling/disabling of RF subsystem notifications.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.176.1.2.12
cRFCfgMaintenanceModeIndicates whether redundant units may communicate synchronization messages with each other. If communication is not permitted, this object is set to 'true'. If communication is permitted, this object is set to 'false'. If the value of this object is 'true', the redundant system is considered to be in a maintenance mode of operation. If the value of this object is 'false', the redundant system is considered to be in a normal (non-maintenance) mode of operation. In maintenance mode (true), the active unit will not communicate with the standby unit. The standby unit progression will not occur. When maintenance mode is disabled (false), the standby unit is reset to recover. Maintenance mode (true) is useful for maintenance-type operations.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.176.1.2.13
cRFCfgRedundancyModeIndicates the redundancy mode configured on the device.rw
RFMode
.1.3.6.1.4.1.9.9.176.1.2.14
cRFCfgRedundancyModeDescrFurther clarifies or describes the redundancy mode indicated by cRFCfgRedundancyMode. Implementation-specific terminology associated with the current redundancy mode may be presented here.ro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.176.1.2.15
cRFCfgRedundancyOperModeIndicate the operational redundancy mode of the device.ro
RFMode
.1.3.6.1.4.1.9.9.176.1.2.16
cRFHistory
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.176.1.3
cRFHistoryTableMaxLengthMaximum number of entries permissible in the history table. A value of 0 will result in no history being maintained.rw
Unsigned32 (0..50 )
.1.3.6.1.4.1.9.9.176.1.3.1
cRFHistorySwitchOverTableA table that tracks the history of all switchovers that have occurred since system initialization. The maximum number of entries permissible in this table is defined by cRFHistoryTableMaxLength. When the number of entries in the table reaches the maximum limit, the next entry would replace the oldest existing entry in the table.
SEQUENCE OF CRFHistorySwitchOverEntry
.1.3.6.1.4.1.9.9.176.1.3.2
cRFHistorySwitchOverEntryThe entries in this table contain the switchover information. Each entry in the table is indexed by cRFHistorySwitchOverIndex. The index wraps around to 1 after reaching the maximum value.
CRFHistorySwitchOverEntry
.1.3.6.1.4.1.9.9.176.1.3.2.1
cRFHistorySwitchOverIndexA monotonically increasing integer for the purpose of indexing history table. After reaching maximum value, it wraps around to 1.
Unsigned32 (1..4294967295 )
.1.3.6.1.4.1.9.9.176.1.3.2.1.1
cRFHistoryPrevActiveUnitIdIndicates the primary redundant unit that went down.ro
RFUnitIdentifier
.1.3.6.1.4.1.9.9.176.1.3.2.1.2
cRFHistoryCurrActiveUnitIdIndicates the secondary redundant unit that took over as active.ro
RFUnitIdentifier
.1.3.6.1.4.1.9.9.176.1.3.2.1.3
cRFHistorySwitchOverReasonIndicates the reason for the switchover.ro
RFSwactReasonType
.1.3.6.1.4.1.9.9.176.1.3.2.1.4
cRFHistorySwactTimeIndicates the Date & Time when switchover occurred.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.176.1.3.2.1.5
cRFHistoryColdStartsIndicates the number of system cold starts. This includes the number of system cold starts due to switchover failure and the number of manual restarts.ro
Counter32
.1.3.6.1.4.1.9.9.176.1.3.3
cRFHistoryStandByAvailTimeIndicates the cumulative time that a standby redundant unit has been available since last system initialization.ro
TimeInterval (SNMPv2-TC)
.1.3.6.1.4.1.9.9.176.1.3.4
cRFClient
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.176.1.4
cRFStatusRFClientTableThis table contains a list of RF clients that are registered on the device. RF clients are applications that have registered with the Redundancy Facility (RF) to receive RF events and notifications. The purpose of RF clients is to synchronize any relevant data with the standby unit.
SEQUENCE OF CRFStatusRFClientEntry
.1.3.6.1.4.1.9.9.176.1.4.1
cRFStatusRFClientEntryAn entry containing information on various clients registered with the Redundancy Facility (RF). Entries in this table are always created by the system. An entry is created in this table when a redundancy aware application registers with the Redundancy Facility. The entry is destroyed when that application deregisters from the Redundancy Facility.
CRFStatusRFClientEntry
.1.3.6.1.4.1.9.9.176.1.4.1.1
cRFStatusRFClientIDA unique identifier for the client which registered with the Redundancy Facility.
Unsigned32 (1..4294967295 )
.1.3.6.1.4.1.9.9.176.1.4.1.1.1
cRFStatusRFClientDescrThe description of the client which has registered with the Redundancy Facility.ro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.176.1.4.1.1.2
cRFStatusRFClientSeqThe sequence number of the client. The system assigns the sequence numbers based on the order of registration of the Redundancy Facility clients. This is used for deciding order of RF events sent to clients.ro
Unsigned32
.1.3.6.1.4.1.9.9.176.1.4.1.1.3
cRFStatusRFClientRedTimeTime taken for this client to become Redundant. This value is meaningful when the value of cRFStatusRFClientStatus is not 'noStatus'.ro
Unsigned32 UNITS "milliseconds"
.1.3.6.1.4.1.9.9.176.1.4.1.1.4
cRFStatusRFClientStatusThis object provides the status of the Redundancy Facility client.ro
RFClientStatus
.1.3.6.1.4.1.9.9.176.1.4.1.1.5
ciscoRFMIBNotificationsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.176.2
ciscoRFMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.176.2.0
ciscoRFSwactNotifA SWACT notification is sent by the newly active redundant unit whenever a switch of activity occurs. In the case where a SWACT event may be indistinguishable from a reset event, a network management station should use this notification to differentiate the activity. sysUpTime is the same sysUpTime defined in the RFC-1213 MIB.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.176.2.0.1
ciscoRFProgressionNotifA progression notification is sent by the active redundant unit whenever its RF state changes or the RF state of the peer unit changes. To avoid a flurry of notifications for all state transitions, notifications will only be sent for transitions to the following RF states: disabled (for the peer state) standbyCold standbyHot active activeExtraload
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.176.2.0.2
ciscoRFIssuStateNotifAn ISSU notification to indicate the new state of the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.176.2.0.3
ciscoRFIssuStateNotifRev1An ISSU notification to indicate the new state of the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.176.2.0.4
ciscoRFMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.176.3
ciscoRFMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.176.3.1
ciscoRFMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.176.3.2