Home/Catalog/CISCO-POE-PD-MIB

CISCO-POE-PD-MIB

AI MIB Summary

The CISCO-POE-PD-MIB enables Network Management Systems to monitor and configure Power over Ethernet (PoE) power consumption, allocation, and negotiation states for Cisco Powered Devices (PDs) such as IP telephones and wireless access points. This module facilitates the tracking of critical power metrics including current power draw, available power budgets, and CDP-based power negotiation results between the PD and Power Source Equipment (PSE).

This MIB is intended for devices powered by external power sources, in particular Power Over Ethernet (PoE or formerly called inline power), to provide power usage configuration and information for NMS. For example, PoE supplies DC power over standard Category 5 unshielded twisted-pair (UTP) cable. Instead of requiring wall power, powered devices such as IP telephones can utilize power provided from power source equipments. By using Cisco Discovery Protocol (CDP), powered devices can negotiated with power source equipment to obtain optimum power supply. GLOSSARY Midspan Injector The midspan PSE sends out a signal tone down one of the unused pairs of the standard Category 5 cable and detects tone on the other unused pair when the PD loops this tone back to it through a loopback transformer. Once the midspan PSE detects this tone, it begins to provide power down the cable using the unused pairs. The midspan PSE provide no physical layer capability. Powered Device ( PD ) These are devices powered by external electrical power sources. They are, for example, IP telephones and wireless Access Points or bridges. Power Source Equipment ( PSE ) These are devices supplying electrical power to other equipments. They are, for example, inline power switches and power patch panels.
Main OID:
ciscoPoePdMIB.1.3.6.1.4.1.9.9.414
14
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

14 total
Object Name
ciscoPoePdMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.414
cpoePdMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.414.0
cpoePdMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.414.1
cpoePdInformation
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.414.1.1
cpoePdCurrentPowerLevelro
Unsigned32
.1.3.6.1.4.1.9.9.414.1.1.1
cpoePdCurrentPowerSourcero
CpoePdPowerSourceType
.1.3.6.1.4.1.9.9.414.1.1.2
cpoePdSupportedPowerLevelTable
SEQUENCE OF CpoePdSupportedPowerLevelEntry
.1.3.6.1.4.1.9.9.414.1.1.3
cpoePdSupportedPowerLevelEntry
CpoePdSupportedPowerLevelEntry
.1.3.6.1.4.1.9.9.414.1.1.3.1
cpoePdSupportedPowerLevel
Unsigned32
.1.3.6.1.4.1.9.9.414.1.1.3.1.1
cpoePdSupportedPowerro
Unsigned32
.1.3.6.1.4.1.9.9.414.1.1.3.1.2
cpoePdSupportedPowerModero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.414.1.1.3.1.3
cpoePdMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.414.2
cpoePdMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.414.2.1
cpoePdMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.414.2.2

CISCO-POE-PD-MIB Technical Reference Overview

The CISCO-POE-PD-MIB SNMP MIB module published by Cisco defines 14 managed OID objects, including 5 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.414. Key tabular structures include cpoePdSupportedPowerLevelTable.

Key OID Definitions in CISCO-POE-PD-MIB

ciscoPoePdMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.414

This MIB is intended for devices powered by external power sources, in particular Power Over Ethernet (PoE or formerly called inline power), to provide power usage configuration and information for NMS. For example, PoE supplies DC power over standard Category 5 unshielded twisted-pair (UTP) cable. Instead of requiring wall power, powered devices such as IP telephones can utilize power provided from power source equipments. By using Cisco Discovery Protocol (CDP), powered devices can negotiated with power source equipment to obtain optimum power supply. GLOSSARY Midspan Injector The midspan PSE sends out a signal tone down one of the unused pairs of the standard Category 5 cable and detects tone on the other unused pair when the PD loops this tone back to it through a loopback transformer. Once the midspan PSE detects this tone, it begins to provide power down the cable using the unused pairs. The midspan PSE provide no physical layer capability. Powered Device ( PD ) These are devices powered by external electrical power sources. They are, for example, IP telephones and wireless Access Points or bridges. Power Source Equipment ( PSE ) These are devices supplying electrical power to other equipments. They are, for example, inline power switches and power patch panels.

cpoePdSupportedPowerLevelTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.414.1.1.3

This table shows all the supported electrical power consumption levels of this agent and the corresponding modes of operation at those power levels. The mode of operation and the device capability changes as the supplied power level varies. The number of supported levels is platform and implementation dependent.

cpoePdCurrentPowerLevelUnsigned32(1..65535)read-only
.1.3.6.1.4.1.9.9.414.1.1.1

This identifies the currently how much power is consummed by the device at which this agent is running. The level shall be one of the cpoePdSupportedPowerLevel in the cpoePdSupportedPowerTable.

cpoePdCurrentPowerSourceCpoePdPowerSourceTyperead-only
.1.3.6.1.4.1.9.9.414.1.1.2

This is the current power source type obtained from device power source detection.

cpoePdSupportedPowerLevelEntryCpoePdSupportedPowerLevelEntrynot-accessible
.1.3.6.1.4.1.9.9.414.1.1.3.1

Each entry shows a supported power level and the corresponding mode of operation.

cpoePdSupportedPowerLevelUnsigned32(1..65535)not-accessible
.1.3.6.1.4.1.9.9.414.1.1.3.1.1

This index uniquely identifies the supported power consumption level.

cpoePdSupportedPowerUnsigned32(1..65535)read-only
.1.3.6.1.4.1.9.9.414.1.1.3.1.2

This is the electrical power consummed by the device operating at this supported power consumption level.

cpoePdSupportedPowerModeSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.414.1.1.3.1.3

This is a text string describing the mode of operation or capability of the device at the power consumption level. For example, the comsumption level and corresponding mode should look like these: 1 'Full power mode' 2 'Low power mode - dot11radio 0 disabled' 3 'Low power mode - dot11radio 1 disabled' 4 'Low power mode - dot11 radios disabled'.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→