Home/Catalog/CISCO-P2P-IF-MIB

CISCO-P2P-IF-MIB

AI MIB Summary

The CISCO-P2P-IF-MIB monitors and manages Cisco serial, SONET, and SDH point-to-point interfaces utilizing PPP, HDLC, or cHDLC encapsulations. It tracks critical link-layer integrity metrics including Frame Check Sequence (FCS) errors and Cyclic Redundancy Check (CRC) failures to validate data transmission accuracy across these specific physical and data link layers.

The Point to Point Interface MIB module. This MIB manages the generic objects for Serial link or SONET/SDH like point to point network interfaces with the encapsulations of PPP (Point to Point Protocol), HDLC (High Level Data Link Control) or cHDLC (CIsco extension to High Level Data Link Control) framing. Acronyms and terms: FCS - Frame Check Sequence. The frame check sequence is used to ensure that the data received is actually the data sent. CRC - Cyclic Redundancy Check. The transmitting system processes the frame check sequence portion of the frame through an algorithm called a CRC (Cyclic Redundancy Check). One of the usages of CRC is in the following PPP/HLDC over SONET/SDH example. ++ | PPP| FCS Bit SONET/SDH |HDLC|=> Generation => Stuffing => Scrambling => Framing ++ CRC 16,32
Main OID:
ciscoP2PIfMIB.1.3.6.1.4.1.9.9.668
15
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

15 total
Object Name
ciscoP2PIfMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.668
ciscoP2PIfMIBNotifs
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.668.0
ciscoP2PIfMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.668.1
cp2pIfGeneralObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.668.1.1
cp2pIfCfgTable
SEQUENCE OF Cp2pIfCfgEntry
.1.3.6.1.4.1.9.9.668.1.1.1
cp2pIfCfgEntry
Cp2pIfCfgEntry
.1.3.6.1.4.1.9.9.668.1.1.1.1
cp2pIfCfgCrcModerw
Cp2pIfCrcMode
.1.3.6.1.4.1.9.9.668.1.1.1.1.1
cp2pIfCfgScramblingModerw
Cp2pIfScramblingMode
.1.3.6.1.4.1.9.9.668.1.1.1.1.2
cp2pIfCfgTransmitDelayrw
Unsigned32
.1.3.6.1.4.1.9.9.668.1.1.1.1.3
cp2pIfStatsTable
SEQUENCE OF Cp2pIfStatsEntry
.1.3.6.1.4.1.9.9.668.1.1.2
cp2pIfStatsEntry
Cp2pIfStatsEntry
.1.3.6.1.4.1.9.9.668.1.1.2.1
cp2pIfStatsInCrcErrorsro
Counter32
.1.3.6.1.4.1.9.9.668.1.1.2.1.1
ciscoP2PIfMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.668.3
ciscoP2PIfMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.668.3.1
ciscoP2PIfMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.668.3.2

CISCO-P2P-IF-MIB Technical Reference Overview

The CISCO-P2P-IF-MIB SNMP MIB module published by Cisco defines 15 managed OID objects, including 5 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.668. Key tabular structures include cp2pIfCfgTable, cp2pIfStatsTable.

Key OID Definitions in CISCO-P2P-IF-MIB

ciscoP2PIfMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.668

The Point to Point Interface MIB module. This MIB manages the generic objects for Serial link or SONET/SDH like point to point network interfaces with the encapsulations of PPP (Point to Point Protocol), HDLC (High Level Data Link Control) or cHDLC (CIsco extension to High Level Data Link Control) framing. Acronyms and terms: FCS - Frame Check Sequence. The frame check sequence is used to ensure that the data received is actually the data sent. CRC - Cyclic Redundancy Check. The transmitting system processes the frame check sequence portion of the frame through an algorithm called a CRC (Cyclic Redundancy Check). One of the usages of CRC is in the following PPP/HLDC over SONET/SDH example. ++ | PPP| FCS Bit SONET/SDH |HDLC|=> Generation => Stuffing => Scrambling => Framing ++ CRC 16,32

cp2pIfCfgTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.668.1.1.1

The Point to Point generic Configuration Table. It contains the standard configuration information of the Point to Point interface.

cp2pIfStatsTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.668.1.1.2

The Point to Point Interface Statistics Table. It contains statistics information of a Point to Point interface including the error statistics.

cp2pIfStatsEntryCp2pIfStatsEntrynot-accessible
.1.3.6.1.4.1.9.9.668.1.1.2.1

An entry in the statistics table for each Point to Point interface.

cp2pIfStatsInCrcErrorsCounter32read-only
.1.3.6.1.4.1.9.9.668.1.1.2.1.1

Accumulated number of CRC errors that are detected on the received packets via the Point to Point interface since system startup.

cp2pIfCfgEntryCp2pIfCfgEntrynot-accessible
.1.3.6.1.4.1.9.9.668.1.1.1.1

An entry in the configuration table for each Point to Point interface. The entry is created when the Point to Point related interface is created in ifTable. The possible ifType of point to point interface are listed as follows: [1] ppp(23) [2] hdlc(118) [3] propPointToPointSerial(22)

cp2pIfCfgCrcModeCp2pIfCrcModeread-write
.1.3.6.1.4.1.9.9.668.1.1.1.1.1

Specifies the CRC mode for the FCS generation of a packet sending via the Point to point interface.

cp2pIfCfgScramblingModeCp2pIfScramblingModeread-write
.1.3.6.1.4.1.9.9.668.1.1.1.1.2

Specifies the scrambling encryption mode of the point to point interface.

cp2pIfCfgTransmitDelayUnsigned32read-write
.1.3.6.1.4.1.9.9.668.1.1.1.1.3

Specified the minimum delay after sending a packet via the point to point interface. The value of '0' indicates the transmit delay of packet is disabled.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→