CISCO-NS-MIB
The CISCO-NS-MIB provides management capabilities for Cisco Fibre Channel Name Servers to monitor FC-GS3 compliant service discovery parameters, including registered domain identifiers, port state transitions, and active fabric service bindings.
Imported Objects
Objects
50 total| Object Name |
|---|
ciscoNsMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.293 |
ciscoNameServerMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.293.1 |
fcNameServerConfiguration OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.293.1.1 |
fcNameServerProxyPortTable SEQUENCE OF FcNameServerProxyPortEntry .1.3.6.1.4.1.9.9.293.1.1.1 |
fcNameServerProxyPortEntry FcNameServerProxyPortEntry .1.3.6.1.4.1.9.9.293.1.1.1.1 |
fcNameServerProxyPortNamerw FcNameIdOrZero (CISCO-ST-TC) .1.3.6.1.4.1.9.9.293.1.1.1.1.1 |
fcNameServerTableLastChangero TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.9.9.293.1.1.2 |
fcNameServerNumRowsro Integer32 .1.3.6.1.4.1.9.9.293.1.1.3 |
fcNameServerTable SEQUENCE OF FcNameServerEntry .1.3.6.1.4.1.9.9.293.1.1.4 |
fcNameServerEntry FcNameServerEntry .1.3.6.1.4.1.9.9.293.1.1.4.1 |
fcNameServerPortIdentifier FcAddressId (CISCO-ST-TC) .1.3.6.1.4.1.9.9.293.1.1.4.1.1 |
fcNameServerPortNamero FcNameId (CISCO-ST-TC) .1.3.6.1.4.1.9.9.293.1.1.4.1.2 |
fcNameServerNodeNamero FcNameId (CISCO-ST-TC) .1.3.6.1.4.1.9.9.293.1.1.4.1.3 |
fcNameServerClassOfSvcro FcClassOfServices (CISCO-ST-TC) .1.3.6.1.4.1.9.9.293.1.1.4.1.4 |
fcNameServerNodeIpAddressrw OCTET STRING .1.3.6.1.4.1.9.9.293.1.1.4.1.5 |
fcNameServerProcAssocro OCTET STRING .1.3.6.1.4.1.9.9.293.1.1.4.1.6 |
fcNameServerFC4Typerw OCTET STRING .1.3.6.1.4.1.9.9.293.1.1.4.1.7 |
fcNameServerPortTypero Enumeration .1.3.6.1.4.1.9.9.293.1.1.4.1.8 |
fcNameServerPortIpAddressrw OCTET STRING .1.3.6.1.4.1.9.9.293.1.1.4.1.9 |
fcNameServerFabricPortNamero FcNameId (CISCO-ST-TC) .1.3.6.1.4.1.9.9.293.1.1.4.1.10 |
fcNameServerHardAddressro FcAddressId (CISCO-ST-TC) .1.3.6.1.4.1.9.9.293.1.1.4.1.11 |
fcNameServerSymbolicPortNamerw SnmpAdminString .1.3.6.1.4.1.9.9.293.1.1.4.1.12 |
fcNameServerSymbolicNodeNamerw SnmpAdminString .1.3.6.1.4.1.9.9.293.1.1.4.1.13 |
fcNameServerFC4Featuresrw OCTET STRING .1.3.6.1.4.1.9.9.293.1.1.4.1.14 |
fcNameServerPortFunctionrodeprecated Bits .1.3.6.1.4.1.9.9.293.1.1.4.1.15 |
fcNameServerPermanentPortNamero FcNameId (CISCO-ST-TC) .1.3.6.1.4.1.9.9.293.1.1.4.1.16 |
fcNameServerRejReqNotifyEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.293.1.1.5 |
fcNameServerStats OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.293.1.2 |
fcNameServerTotalRejectsro Counter32 .1.3.6.1.4.1.9.9.293.1.2.1 |
fcNameServerStatsTable SEQUENCE OF FcNameServerStatsEntry .1.3.6.1.4.1.9.9.293.1.2.2 |
fcNameServerStatsEntry FcNameServerStatsEntry .1.3.6.1.4.1.9.9.293.1.2.2.1 |
fcNameServerInGetReqsro Counter32 .1.3.6.1.4.1.9.9.293.1.2.2.1.1 |
fcNameServerOutGetReqsro Counter32 .1.3.6.1.4.1.9.9.293.1.2.2.1.2 |
fcNameServerInRegReqsro Counter32 .1.3.6.1.4.1.9.9.293.1.2.2.1.3 |
fcNameServerInDeRegReqsro Counter32 .1.3.6.1.4.1.9.9.293.1.2.2.1.4 |
fcNameServerInRscnsro Counter32 .1.3.6.1.4.1.9.9.293.1.2.2.1.5 |
fcNameServerOutRscnsro Counter32 .1.3.6.1.4.1.9.9.293.1.2.2.1.6 |
fcNameServerRejectsro Counter32 .1.3.6.1.4.1.9.9.293.1.2.2.1.7 |
fcNameServerInformation OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.293.1.3 |
fcNameServerRejectReasonCodero FcGs3RejectReasonCode .1.3.6.1.4.1.9.9.293.1.3.1 |
fcNameServerRejReasonCodeExpro FcNameServerRejReasonExpl .1.3.6.1.4.1.9.9.293.1.3.2 |
fcNameServerNotification OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.293.1.4 |
fcNameServerNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.293.1.4.0 |
fcNameServerRejectRegNotify NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.293.1.4.0.1 |
fcNameServerDatabaseFull NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.293.1.4.0.2 |
fcNameServerEntryAdd NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.293.1.4.0.3 |
fcNameServerEntryDelete NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.293.1.4.0.4 |
fcNameServerMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.293.2 |
fcNameServerMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.293.2.1 |
fcNameServerMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.293.2.2 |
CISCO-NS-MIB Technical Reference Overview
The CISCO-NS-MIB SNMP MIB module published by Cisco defines 50 managed OID objects, including 30 scalar/column metrics, 3 SNMP tables, and 4 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.293. Key tabular structures include fcNameServerProxyPortTable, fcNameServerTable, fcNameServerStatsTable. Monitored SNMP traps/notifications include fcNameServerRejectRegNotify, fcNameServerDatabaseFull, fcNameServerEntryAdd, fcNameServerEntryDelete.
Key OID Definitions in CISCO-NS-MIB
.1.3.6.1.4.1.9.9.293The MIB module for the management of the Cisco Name Server which realizes the FC-GS3 requirements for Name Server (NS).
.1.3.6.1.4.1.9.9.293.1.1.1This table contains a list of proxy ports on all configured VSANs on the local switch. Only one proxy port is allowed on a VSAN.
.1.3.6.1.4.1.9.9.293.1.1.4This table contains entries for all Nx_Ports registered with Fx_Ports on all the VSANs configured on the local switch.
.1.3.6.1.4.1.9.9.293.1.2.2This table contains statistic counters which are maintained by the Name Server. These counters are maintained per VSAN.
.1.3.6.1.4.1.9.9.293.1.4.0.1This notification is generated by the Name Server whenever it rejects a registration request. The Name Server should update the 'fcNameServerRejectReasonCode' and 'fcNameServerRejReasonCodeExp' objects with the corresponding reason code and reason code explanation before sending the notification. These two objects are also included along with the notification to provide the reason for the reject.
.1.3.6.1.4.1.9.9.293.1.4.0.2This notification is generated by the Name Server when the Name Server cannot allocate space for a new entry.
.1.3.6.1.4.1.9.9.293.1.4.0.3This notification is generated by the Name Server when a new entry gets added to the Name Server database.
.1.3.6.1.4.1.9.9.293.1.4.0.4This notification is generated by the Name Server when an existing entry is deleted from the Name Server database.
.1.3.6.1.4.1.9.9.293.1.1.2The value of sysUpTime at the time of the last update to the fcNameServerTable. This includes creation of an entry, deletion of an entry and modification of an existing entry. If no updates have taken place since the last re-initialization of the local network management subsystem, then this object contains a zero value.
.1.3.6.1.4.1.9.9.293.1.1.3The number of Nx_Ports currently registered with this device fabric wide.
.1.3.6.1.4.1.9.9.293.1.2.1The total number of requests rejected by the local switch across all VSANs.
.1.3.6.1.4.1.9.9.293.1.3.1The registration reject reason code. This object contains the reason code corresponding to the most recent Name Server Registration request failure.
.1.3.6.1.4.1.9.9.293.1.3.2The registration reject reason code explanation. This object contains the reason code explanation if the above object has a reason code corresponding to 'Unable to perform command request'. This object like the one above, corresponds to the most recent Name Server Registration request rejection.
.1.3.6.1.4.1.9.9.293.1.1.5This object specifies if the Name Server should generate 'fcNameServerRejectRegNotify' notifications. If value of this object is 'true', then the notification is generated when a request is rejected. If it is 'false', the notification is not generated.
.1.3.6.1.4.1.9.9.293.1.1.1.1An entry (conceptual row) in this table.
.1.3.6.1.4.1.9.9.293.1.1.1.1.1Name of the proxy port which can register/deregister for other ports on this VSAN. Users can enable third party registrations by setting this object. In order to disable third party registrations, this object should be set to ''H.
.1.3.6.1.4.1.9.9.293.1.1.4.1An entry (conceptual row) in the fcNameServerTable. This contains information about an Nx_Port represented by fcNameServerPortIdentifier for a particular VSAN identified by vsanIndex.
.1.3.6.1.4.1.9.9.293.1.1.4.1.1The Fibre Channel Identifier (FC-ID) of this Nx_Port.
.1.3.6.1.4.1.9.9.293.1.1.4.1.2The fibre channel Port_Name (WWN) of this Nx_port. If this object is not set, then it will contain the null value '0000000000000000'h.
.1.3.6.1.4.1.9.9.293.1.1.4.1.3The fibre channel Node_Name (WWN) of this Nx_port. If this object is not set, then it will contain the null value '0000000000000000'h.
.1.3.6.1.4.1.9.9.293.1.1.4.1.4The class of service indicator. This object is a array of bits that contain a bit map of the classes of service supported by the associated port. If a bit in this object is 1, it indicates that the class of service is supported by the associated port. When a bit is set to 0, it indicates that no class of service is supported by this Nx_port.
.1.3.6.1.4.1.9.9.293.1.1.4.1.5The IP address of the node of this Nx_port, as indicated by the Nx_Port in a GS3 message that it transmitted. The GS3 format specifies a 32-bit IPv4 address or a 128-bit IPv6 address. For the former, the leftmost 96 bits (12 bytes) are set to x'00 00 00 00 00 00 00 00 00 00 FF FF' and the rightmost 32 bits are supposed to contain the IPv4 address.
.1.3.6.1.4.1.9.9.293.1.1.4.1.6The Fibre Channel initial process associator (IPA).
.1.3.6.1.4.1.9.9.293.1.1.4.1.7The FC-4 protocol types supported by this Nx_port. This is an array of 256-bits. Each bit in the array corresponds to a Type value as defined by the fibre channel standards and contained in the Type field of the frame header.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.