CISCO-NETSYNC-MIB
The CISCO-NETSYNC-MIB monitors Synchronous Ethernet (SyncE) clock selection and synchronization status on Cisco network equipment, specifically tracking ESMC (Ethernet Synchronization Messaging Channel) parameters, Quality Level (QL) values, and Synchronization Status Messages (SSM) to enforce ITU-T G.781 compliance and prevent timing loops. This module provides visibility into frequency traceability and clock source health across the Ethernet PHY layer, enabling the management of Ethernet Equipment Clocks (EEC) and Stand Alone Synchronization Equipment (SASE) states.
Imported Objects
Objects
94 total| Object Name |
|---|
ciscoNetsyncMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.761 |
ciscoNetsyncMIBNotifs OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.761.0 |
ciscoNetsyncSelectedT0Clock NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.761.0.1 |
ciscoNetsyncSelectedT4Clock NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.761.0.2 |
ciscoNetsyncInputSignalFailureStatus NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.761.0.3 |
ciscoNetsyncInputAlarmStatus NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.761.0.4 |
ciscoNetsyncMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.761.1 |
ciscoNetsyncMIBTables OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.761.1.1 |
cnsClkSelGlobalTable SEQUENCE OF CnsClkSelGlobalEntry .1.3.6.1.4.1.9.9.761.1.1.1 |
cnsClkSelGlobalEntry CnsClkSelGlobalEntry .1.3.6.1.4.1.9.9.761.1.1.1.1 |
cnsClkSelGloProcIndex Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.1.1.1 |
cnsClkSelGlobProcessModero CiscoNetsyncQLMode .1.3.6.1.4.1.9.9.761.1.1.1.1.2 |
cnsClkSelGlobClockModero CiscoNetsyncClockMode .1.3.6.1.4.1.9.9.761.1.1.1.1.3 |
cnsClkSelGlobNetsyncEnablero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.1.1.4 |
cnsClkSelGlobRevertiveModero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.1.1.5 |
cnsClkSelGlobESMCModero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.1.1.6 |
cnsClkSelGlobEECOptionro CiscoNetsyncEECOption .1.3.6.1.4.1.9.9.761.1.1.1.1.7 |
cnsClkSelGlobNetworkOptionro CiscoNetsyncNetworkOption .1.3.6.1.4.1.9.9.761.1.1.1.1.8 |
cnsClkSelGlobHoldoffTimero Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.1.1.9 |
cnsClkSelGlobWtrTimero Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.1.1.10 |
cnsClkSelGlobNofSourcesro Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.1.1.11 |
cnsClkSelGlobLastHoldoverSecondsro Gauge32 UNITS "seconds" .1.3.6.1.4.1.9.9.761.1.1.1.1.12 |
cnsClkSelGlobCurrHoldoverSecondsro Gauge32 UNITS "seconds" .1.3.6.1.4.1.9.9.761.1.1.1.1.13 |
cnsSelectedInputSourceTable SEQUENCE OF CnsSelectedInputSourceEntry .1.3.6.1.4.1.9.9.761.1.1.2 |
cnsSelectedInputSourceEntry CnsSelectedInputSourceEntry .1.3.6.1.4.1.9.9.761.1.1.2.1 |
cnsSelInpSrcNetsyncIndex Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.2.1.1 |
cnsSelInpSrcNamero SnmpAdminString .1.3.6.1.4.1.9.9.761.1.1.2.1.2 |
cnsSelInpSrcIntfTypero CiscoNetsyncIfType .1.3.6.1.4.1.9.9.761.1.1.2.1.3 |
cnsSelInpSrcQualityLevelro CiscoNetsyncQualityLevel .1.3.6.1.4.1.9.9.761.1.1.2.1.4 |
cnsSelInpSrcPriorityro Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.2.1.5 |
cnsSelInpSrcTimestampro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.2.1.6 |
cnsSelInpSrcFSWro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.2.1.7 |
cnsSelInpSrcMSWro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.2.1.8 |
cnsInputSourceTable SEQUENCE OF CnsInputSourceEntry .1.3.6.1.4.1.9.9.761.1.1.3 |
cnsInputSourceEntry CnsInputSourceEntry .1.3.6.1.4.1.9.9.761.1.1.3.1 |
cnsInpSrcNetsyncIndex Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.3.1.1 |
cnsInpSrcNamero SnmpAdminString .1.3.6.1.4.1.9.9.761.1.1.3.1.2 |
cnsInpSrcIntfTypero CiscoNetsyncIfType .1.3.6.1.4.1.9.9.761.1.1.3.1.3 |
cnsInpSrcPriorityro Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.3.1.4 |
cnsInpSrcESMCCapro CiscoNetsyncESMCCap .1.3.6.1.4.1.9.9.761.1.1.3.1.5 |
cnsInpSrcSSMCapro CiscoNetsyncSSMCap .1.3.6.1.4.1.9.9.761.1.1.3.1.6 |
cnsInpSrcQualityLevelTxCfgro CiscoNetsyncQualityLevel .1.3.6.1.4.1.9.9.761.1.1.3.1.7 |
cnsInpSrcQualityLevelRxCfgro CiscoNetsyncQualityLevel .1.3.6.1.4.1.9.9.761.1.1.3.1.8 |
cnsInpSrcQualityLevelTxro CiscoNetsyncQualityLevel .1.3.6.1.4.1.9.9.761.1.1.3.1.9 |
cnsInpSrcQualityLevelRxro CiscoNetsyncQualityLevel .1.3.6.1.4.1.9.9.761.1.1.3.1.10 |
cnsInpSrcQualityLevelro CiscoNetsyncQualityLevel .1.3.6.1.4.1.9.9.761.1.1.3.1.11 |
cnsInpSrcHoldoffTimero Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.3.1.12 |
cnsInpSrcWtrTimero Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.3.1.13 |
cnsInpSrcLockoutro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.3.1.14 |
cnsInpSrcSignalFailurero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.3.1.15 |
cnsInpSrcAlarmro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.3.1.16 |
cnsInpSrcAlarmInforo CiscoNetsyncAlarmInfo .1.3.6.1.4.1.9.9.761.1.1.3.1.17 |
cnsInpSrcFSWro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.3.1.18 |
cnsInpSrcMSWro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.3.1.19 |
cnsExtOutputTable SEQUENCE OF CnsExtOutputEntry .1.3.6.1.4.1.9.9.761.1.1.4 |
cnsExtOutputEntry CnsExtOutputEntry .1.3.6.1.4.1.9.9.761.1.1.4.1 |
cnsExtOutListIndex Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.4.1.1 |
cnsExtOutSelNetsyncIndexro Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.4.1.2 |
cnsExtOutNamero SnmpAdminString .1.3.6.1.4.1.9.9.761.1.1.4.1.3 |
cnsExtOutIntfTypero CiscoNetsyncIfType .1.3.6.1.4.1.9.9.761.1.1.4.1.4 |
cnsExtOutQualityLevelro CiscoNetsyncQualityLevel .1.3.6.1.4.1.9.9.761.1.1.4.1.5 |
cnsExtOutPriorityro Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.4.1.6 |
cnsExtOutFSWro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.4.1.7 |
cnsExtOutMSWro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.4.1.8 |
cnsExtOutSquelchro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.4.1.9 |
cnsT4ClockSourceTable SEQUENCE OF CnsT4ClockSourceEntry .1.3.6.1.4.1.9.9.761.1.1.5 |
cnsT4ClockSourceEntry CnsT4ClockSourceEntry .1.3.6.1.4.1.9.9.761.1.1.5.1 |
cnsT4ClkSrcNetsyncIndex Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.5.1.1 |
cnsT4ClkSrcNamero SnmpAdminString .1.3.6.1.4.1.9.9.761.1.1.5.1.2 |
cnsT4ClkSrcIntfTypero CiscoNetsyncIfType .1.3.6.1.4.1.9.9.761.1.1.5.1.3 |
cnsT4ClkSrcPriorityro Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.5.1.4 |
cnsT4ClkSrcESMCCapro CiscoNetsyncESMCCap .1.3.6.1.4.1.9.9.761.1.1.5.1.5 |
cnsT4ClkSrcSSMCapro CiscoNetsyncSSMCap .1.3.6.1.4.1.9.9.761.1.1.5.1.6 |
cnsT4ClkSrcQualityLevelTxCfgro CiscoNetsyncQualityLevel .1.3.6.1.4.1.9.9.761.1.1.5.1.7 |
cnsT4ClkSrcQualityLevelRxCfgro CiscoNetsyncQualityLevel .1.3.6.1.4.1.9.9.761.1.1.5.1.8 |
cnsT4ClkSrcQualityLevelTxro CiscoNetsyncQualityLevel .1.3.6.1.4.1.9.9.761.1.1.5.1.9 |
cnsT4ClkSrcQualityLevelRxro CiscoNetsyncQualityLevel .1.3.6.1.4.1.9.9.761.1.1.5.1.10 |
cnsT4ClkSrcQualityLevelro CiscoNetsyncQualityLevel .1.3.6.1.4.1.9.9.761.1.1.5.1.11 |
cnsT4ClkSrcHoldoffTimero Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.5.1.12 |
cnsT4ClkSrcWtrTimero Unsigned32 .1.3.6.1.4.1.9.9.761.1.1.5.1.13 |
cnsT4ClkSrcLockoutro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.5.1.14 |
cnsT4ClkSrcSignalFailurero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.5.1.15 |
cnsT4ClkSrcAlarmro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.5.1.16 |
cnsT4ClkSrcAlarmInforo CiscoNetsyncAlarmInfo .1.3.6.1.4.1.9.9.761.1.1.5.1.17 |
cnsT4ClkSrcFSWro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.5.1.18 |
cnsT4ClkSrcMSWro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.1.5.1.19 |
cnsNotifObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.761.1.2 |
cnsInpSrcFailClearro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.2.1 |
cnsInpSrcAlarmClearro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.2.2 |
ciscoNetsyncMIBNotifControl OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.761.1.3 |
cnsMIBEnableStatusNotificationrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.761.1.3.1 |
ciscoNetsyncMIBConform OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.761.2 |
ciscoNetsyncMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.761.2.1 |
ciscoNetsyncMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.761.2.2 |
CISCO-NETSYNC-MIB Technical Reference Overview
The CISCO-NETSYNC-MIB SNMP MIB module published by Cisco defines 94 managed OID objects, including 71 scalar/column metrics, 5 SNMP tables, and 4 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.761. Key tabular structures include cnsClkSelGlobalTable, cnsSelectedInputSourceTable, cnsInputSourceTable, cnsExtOutputTable, cnsT4ClockSourceTable. Monitored SNMP traps/notifications include ciscoNetsyncSelectedT0Clock, ciscoNetsyncSelectedT4Clock, ciscoNetsyncInputSignalFailureStatus, ciscoNetsyncInputAlarmStatus.
Key OID Definitions in CISCO-NETSYNC-MIB
.1.3.6.1.4.1.9.9.761The Synchronous Ethernet (SyncE) MIB is defined for monitoring network synchronization based on ITU-T G.781 clock selection. Synchronous Ethernet (SyncE) is a standard defined for delivering timing to the remote NEs through a Packet Network. SyncE is well defined by ITU-T which included G.8261, G.8262, G.8264 and G.781. It leverages the PHY layer of Ethernet to transmit frequency to the remote sites. Its functionality and accuracy mimics that of the SONET/SDH network because of its physical layer characteristic. In order to allow best clock source traceabiliy, correctly define the timing source and helps preventing timing loop, Synchronization Status Message is required for SyncE. This is similar to SONET/SDH. However, since SONET/SDH use 4 bits from the two S bytes in the SONET/SDH overhead frame for such message, Ethernet relies on a different channel called ESMC (Ethernet Synchronization Messaging Channel) which is based on IEEE 802.3 Organization Specific Slow Protocol. Glossary: AIS: Alarm Indication Signal ATM: Asynchronous Transfer Mode EEC: Ethernet Equipment Clock ESMC: Ethernet Synchronization Messaging Channel QL: Quality Level SASE: Stand Alone Synchronization Equipment SSM: Synchronization Status Messaging
.1.3.6.1.4.1.9.9.761.1.1.1G.781 clock selection process table. This table contains the global parameters for the G.781 clock selection process.
.1.3.6.1.4.1.9.9.761.1.1.2T0 selected clock source table. This table contains the selected clock source for the input T0 clock.
.1.3.6.1.4.1.9.9.761.1.1.3T0 clock source table. This table contains a list of input sources for input T0 clock selection.
.1.3.6.1.4.1.9.9.761.1.1.4T4 external output table. This table contains a list of T4 external outputs. Each T4 external output is associated with clock source(s) to be found in cnsT4ClockSourceTable. The clock selection process considers all the available clock sources and select the T4 clock source based on the G.781 clock selection algorithm.
.1.3.6.1.4.1.9.9.761.1.1.5T4 clock source table. This table contains a list of input sources for a specific T4 external output. An entry shall be added to cnsExtOutputTable first. Then clock sources shall be added in this table for the selection process to select the appropriate T4 clock source.
.1.3.6.1.4.1.9.9.761.0.1T0 clock selection notification. This notification is generated when one of the following conditions is met: - A new clock source is selected by the T0 clock selection. - The clock quality of a T0 selected clock source is changed. - The configured priority of a T0 selected clock source is changed.
.1.3.6.1.4.1.9.9.761.0.2T4 clock selection notification. This notification is generated when one of the following conditions is met: - A new clock source is selected by the T4 clock selection. - The clock quality of a T4 selected clock source is changed. - The configured priority of a T4 selected clock source is changed.
.1.3.6.1.4.1.9.9.761.0.3Input clock source signal failure notification. This notification is generated when a signal failure event is reported on an input clock source. One of the conditions a signal failure event could be due to interface shutdown.
.1.3.6.1.4.1.9.9.761.0.4Input clock source alarm notification. This notification is generated when an alarm event is reported on an input clock source.
.1.3.6.1.4.1.9.9.761.1.2.1This object indicates the clear status of a signal failure event. A value of 'true' means a signal failure event reported on a clock source has been cleared. A value of 'false' means a signal event has been reported on a clock source.
.1.3.6.1.4.1.9.9.761.1.2.2This object indicates the clear status of an alarm event. A value of 'true' means an alarm event reported on a clock source has been cleared. A value of 'false' means an alarm event has been reported on a clock source.
.1.3.6.1.4.1.9.9.761.1.3.1A control object to enable/disable ciscoNetsyncSelectedT0Clock, ciscoNetsyncSelectedT4Clock, ciscoNetsyncInputSignalFailureStatus, ciscoNetsyncInputAlarmStatus notifications at the system level. This object should hold any of the below values. true - The notif is enabled globally for the system false- The notif is disabled globally for the system
.1.3.6.1.4.1.9.9.761.1.1.1.1An entry is added to cnsClkSelGlobalTable when G.781 clock selection is enabled in the device configuration. The entry is removed when G.781 clock selection is removed from the configuration.
.1.3.6.1.4.1.9.9.761.1.1.1.1.1An index that uniquely represents a clock selection process. This index is assigned arbitrarily by the system and may not be persistent across reboots.
.1.3.6.1.4.1.9.9.761.1.1.1.1.2This object indicates the QL mode of the network synchronization clock selection process as described in ITU-T standard G.781 section 5.12.
.1.3.6.1.4.1.9.9.761.1.1.1.1.3This object indicates the operating mode of the system clock.
.1.3.6.1.4.1.9.9.761.1.1.1.1.4This object indicates whether the G.781 clock selection is enabled or not. 'true' - G.781 clock selection is enabled 'false' - G.781 clock selection is disabled
.1.3.6.1.4.1.9.9.761.1.1.1.1.5This object indicates the revertive mode setting in the G.781 clock selection process. The switching of clock sources can be made revertive or non-revertive. In non-revertive mode, an alternate clock source is maintained even after the original clock source has recovered from the failure that caused the switch. In revertive mode, the clock selection process switches back to the original clock source after recovering from the failure.
.1.3.6.1.4.1.9.9.761.1.1.1.1.6This object indicates if global ESMC is enabled. With ESMC enabled globally, the system is capable of handling ESMC messages.
.1.3.6.1.4.1.9.9.761.1.1.1.1.7This object indicates the network synchronization EEC (Ethernet Equipment Clock) option.
.1.3.6.1.4.1.9.9.761.1.1.1.1.8This object indicates the synchronization network option.
.1.3.6.1.4.1.9.9.761.1.1.1.1.9This object indicates the global holdoff time in the G.781 clock selection process.
.1.3.6.1.4.1.9.9.761.1.1.1.1.10This object indicates the global wait-to-restore time in the G.781 clock selection process.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.