CISCO-NDE-MIB
The CISCO-NDE-MIB enables configuration and monitoring of Cisco NetFlow Data Export parameters, specifically managing UDP packet transmission to collectors and defining flow identification criteria based on source/destination IP addresses, transport ports, IP protocol types, Type of Service, and input interface identifiers.
Imported Objects
Objects
15 total| Object Name |
|---|
ciscoNDEMIBThe Netflow Data Export (NDE) MIB provides instrumentation for
configuration and operation of the Netflow Data Export feature.
A network flow is defined as an unidirectional sequence of
packets between a given source and destination endpoints.
Network flows are highly granular; flow endpoints are
identified both by IP address as well as by transport layer
application port numbers. NetFlow also utilizes the IP
Protocol type, Type of Service (ToS) and the input interface
identifier to uniquely identify flows.
Netflow Data Export refers to the export of Netflow Data using
UDP packets to Netflow Data Collector(s). A NetFlow Data
Collector (NDC) captures, filters, aggregates, and stores the
data from multiple NetFlow enabled devices. NDCs provide fast,
scalable, and economical Netflow data. MODULE-IDENTITY .1.3.6.1.4.1.9.9.226 |
cndeMIBNotifs OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.226.0 |
ciscoNDEMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.226.1 |
cndeCollectorConfiguration OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.226.1.1 |
cndeMaxCollectorsMaximum number of entries allowed in the cndeCollectorTable.
A zero indicates unlimitted number of entries.
The agent should set this value during initialization, and
the vaule for this object cannot be changed during the
system's operationro Unsigned32 .1.3.6.1.4.1.9.9.226.1.1.1 |
cndeCollectorTableA control table to configure the NDE collectors.
The maximum number of entries is limited by cndeMaxCollectors.
The agent sends the NDE packets to each address configured
in this table. SEQUENCE OF CndeCollectorEntry .1.3.6.1.4.1.9.9.226.1.1.2 |
cndeCollectorEntryA conceptual row in the cndeCollectorEntry. CndeCollectorEntry .1.3.6.1.4.1.9.9.226.1.1.2.1 |
cndeCollectorAddressTypeThe type of Internet address used by this entry InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.226.1.1.2.1.1 |
cndeCollectorAddressThe Internet address of the collector. This is the
address which the Netflow data is exported to. InetAddress .1.3.6.1.4.1.9.9.226.1.1.2.1.2 |
cndeCollectorPortThe transport port of the collector which the
Netflow data is exported to. Integer32 .1.3.6.1.4.1.9.9.226.1.1.2.1.3 |
cndeCollectorStatusThe status object used to manage the rows in this table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.226.1.1.2.1.4 |
cndeMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.226.2 |
cndeMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.226.3 |
cndeMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.226.3.1 |
cndeMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.226.3.2 |
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-ENTITY-VENDORTYPE-OID-MIB maps Cisco-specific hardware component identifiers to the ENTITY-MIB's entPhysicalTable, enabling precise differentiation of physical device types such as line cards, power supplies, and fans within Cisco infrastructure. This mapping ensures that SNMP management systems can accurately correlate physical inventory entries with vendor-specific component definitions for accurate device discovery and monitoring.
The CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB provides SNMP-based monitoring and management of Cisco Unified Computing System (UCS) hardware components, including chassis, blades, fabric interconnects, and power supplies. It exposes critical operational metrics such as device status, port states, temperature readings, fan speeds, and power consumption data for infrastructure health assessment.
The CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB enables SNMP-based monitoring and management of physical and virtual network adapter interfaces, including link status, traffic counters, error statistics, and port configuration parameters, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers.
The CISCO-UNIFIED-COMPUTING-TC-MIB module defines standard textual conventions and data type definitions required for monitoring Cisco Unified Computing System (UCS) hardware components, including server blades, fabric interconnects, and chassis resources. These definitions enable consistent interpretation of specific UCS metrics such as power supply status, fan speeds, thermal readings, and port utilization across SNMP management applications.
The CISCO-UNIFIED-COMPUTING-FABRIC-MIB enables SNMP-based monitoring and management of the Cisco UCS Fabric Interconnects and associated fabric switching infrastructure, exposing metrics for port states, link utilization, error counters, and fabric topology status. It facilitates granular visibility into the physical and logical fabric layers, including uplink/downlink interfaces, VLAN configurations, and fabric failover conditions within the unified computing environment.
The STARENT-MIB module provides SNMP management and monitoring capabilities for Cisco ASR 5000 and ASR 5500 multimedia core platforms, specifically exposing metrics related to 2G/3G/4G and WiFi subscriber sessions, inline service states, and carrier-class high-availability status.