CISCO-LWAPP-INTERFACE-MIB
The CISCO-LWAPP-INTERFACE-MIB provides management interfaces for Cisco Central Controllers to monitor and configure LWAPP tunnel endpoints and associated WLAN parameters for connected Lightweight Access Points. It enables the retrieval of operational status and configuration state for the specific 802.11 frame encapsulation tunnels terminating at the controller.
Imported Objects
Objects
22 total| Object Name |
|---|
ciscoLwappInterfaceMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.686 |
ciscoLwappInterfaceMIBNotifs OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.686.0 |
ciscoLwappInterfaceMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.686.1 |
ciscoLwappInterfaceConfig OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.686.1.1 |
clInterfaceConfigTable SEQUENCE OF ClInterfaceConfigEntry .1.3.6.1.4.1.9.9.686.1.1.1 |
clInterfaceConfigEntry ClInterfaceConfigEntry .1.3.6.1.4.1.9.9.686.1.1.1.1 |
clInterfaceName OCTET STRING .1.3.6.1.4.1.9.9.686.1.1.1.1.1 |
clInterfaceWiredrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.686.1.1.1.1.2 |
clInterfaceQuarantineVlanIdrw Unsigned32 .1.3.6.1.4.1.9.9.686.1.1.1.1.3 |
clInterfaceDhcpOpt82Enabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.686.1.1.1.1.4 |
clInterfaceGroupsConfigTable SEQUENCE OF ClInterfaceGroupsConfigEntry .1.3.6.1.4.1.9.9.686.1.1.2 |
clInterfaceGroupsConfigEntry ClInterfaceGroupsConfigEntry .1.3.6.1.4.1.9.9.686.1.1.2.1 |
clInterfaceGroupName SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.686.1.1.2.1.1 |
clInterfaceGroupDescrrw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.686.1.1.2.1.2 |
clInterfaceGroupIsQuarantinero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.686.1.1.2.1.3 |
clInterfaceGroupRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.686.1.1.2.1.4 |
clInterfaceGroupsMappingTable SEQUENCE OF ClInterfaceGroupsMappingEntry .1.3.6.1.4.1.9.9.686.1.1.3 |
clInterfaceGroupsMappingEntry ClInterfaceGroupsMappingEntry .1.3.6.1.4.1.9.9.686.1.1.3.1 |
clInterfaceGroupMappingRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.686.1.1.3.1.1 |
ciscoLwappInterfaceMIBConform OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.686.2 |
ciscoLwappInterfaceMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.686.2.1 |
ciscoLwappInterfaceMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.686.2.2 |
CISCO-LWAPP-INTERFACE-MIB Technical Reference Overview
The CISCO-LWAPP-INTERFACE-MIB SNMP MIB module published by Cisco defines 22 managed OID objects, including 9 scalar/column metrics, 3 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.686. Key tabular structures include clInterfaceConfigTable, clInterfaceGroupsConfigTable, clInterfaceGroupsMappingTable.
Key OID Definitions in CISCO-LWAPP-INTERFACE-MIB
.1.3.6.1.4.1.9.9.686This MIB is intended to be implemented on all those devices operating as Central Controllers (CC) that terminate the Light Weight Access Point Protocol tunnel from Cisco Light-weight LWAPP Access Points. This MIB helps to manage the WLANs on the controller. The relationship between CC and the LWAPP APs can be depicted as follows: +......+ +......+ +......+ +......+ + + + + + + + + + CC + + CC + + CC + + CC + + + + + + + + + +......+ +......+ +......+ +......+ .. . . . .. . . . . . . . . . . . . . . . . . . . . . . . +......+ +......+ +......+ +......+ +......+ + + + + + + + + + + + AP + + AP + + AP + + AP + + AP + + + + + + + + + + + +......+ +......+ +......+ +......+ +......+ . . . . . . . . . . . . . . . . . . . . . . . . +......+ +......+ +......+ +......+ +......+ + + + + + + + + + + + MN + + MN + + MN + + MN + + MN + + + + + + + + + + + +......+ +......+ +......+ +......+ +......+ The LWAPP tunnel exists between the controller and the APs. The MNs communicate with the APs through the protocol defined by the 802.11 standard. LWAPP APs, upon bootup, discover and join one of the controllers and the controller pushes the configuration, that includes the WLAN parameters, to the LWAPP APs. The APs then encapsulate all the 802.11 frames from wireless clients inside LWAPP frames and forward the LWAPP frames to the controller. GLOSSARY Access Point ( AP ) An entity that contains an 802.11 medium access control ( MAC ) and physical layer ( PHY ) interface and provides access to the distribution services via the wireless medium for associated clients. LWAPP APs encapsulate all the 802.11 frames in LWAPP frames and sends it to the controller to which it is logically connected to. Central Controller ( CC ) The central entity that terminates the LWAPP protocol tunnel from the LWAPP APs. Throughout this MIB, this entity also referred to as 'controller'. Light Weight Access Point Protocol ( LWAPP ) This is a generic protocol that defines the communication between the Access Points and the controllers. Mobile Node ( MN ) A roaming 802.11 wireless device in a wireless network associated with an access point. REFERENCE [1] Wireless LAN Medium Access Control ( MAC ) and Physical Layer ( PHY ) Specifications. [2] Draft-obara-capwap-lwapp-00.txt, IETF Light Weight Access Point Protocol
.1.3.6.1.4.1.9.9.686.1.1.1This table represents the configuration of all the interfaces, both the static and the dynamic interfaces, on the Wireless LAN Controller(WLC).
.1.3.6.1.4.1.9.9.686.1.1.2This table is used to maintain the interface groups. An interface group is a logical grouping of interfaces with unique VLAN ids.
.1.3.6.1.4.1.9.9.686.1.1.3This table represents the mapping between the interface and the interface group.
.1.3.6.1.4.1.9.9.686.1.1.1.1This represents an entry in the clInterfaceConfigTable. Each entry corresponds to an interface, indicated by clInterfaceName.
.1.3.6.1.4.1.9.9.686.1.1.1.1.1This object represents the name of the interface on the controller.
.1.3.6.1.4.1.9.9.686.1.1.1.1.2This object indicates whether the interface represented by clInterfaceName, will be used for the wireless clients that are connected to the WLC or will be used for the wired clients connected to the WLC.
.1.3.6.1.4.1.9.9.686.1.1.1.1.3This object represents the quarantine vlan id of the interface. If the value is zero,then it means the interface is non-quarantine and the client traffic through this interface need not pass through any security checks. If the value is non-zero, then it means the interface is quarantine and the client traffic through this interface should pass through the security check and there should be an access vlan mapped to this quarantine vlan id, in the security device.
.1.3.6.1.4.1.9.9.686.1.1.1.1.4This object indicates whether the interface represented by clInterfaceName, has DHCP Option 82 enabled on it or not.
.1.3.6.1.4.1.9.9.686.1.1.2.1This represents an entry in clInterfaceGroupsConfigTable. Entries can be added or deleted by explicit management action by NMS or by user console.
.1.3.6.1.4.1.9.9.686.1.1.2.1.1This object represents the name assigned to identify the interface group.
.1.3.6.1.4.1.9.9.686.1.1.2.1.2This object describes the interface group.
.1.3.6.1.4.1.9.9.686.1.1.2.1.3This object indicates whether the interface group has quarantine interfaces. A value of 'true' specifies the interface group has quarantine interfaces. A value of 'false' specifies the group has nonquarantine interfaces.
.1.3.6.1.4.1.9.9.686.1.1.2.1.4This object is used to add or delete entries in clInterfaceGroupsConfigTable
.1.3.6.1.4.1.9.9.686.1.1.3.1This represents an entry in clInterfaceGroupsMappingTable Entries can be added or deleted by explicit management action By NMS or by user console .
.1.3.6.1.4.1.9.9.686.1.1.3.1.1This object is used to add or delete entries in clInterfaceGroupsMappingTable
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.