AI MIB Summary

The CISCO-LPTS-MIB monitors the Local Packet Transport Services subsystem on Cisco routers to track per-protocol flow classifications, trust levels, and associated policer rate limits (PPS) that govern the ingress traffic volume destined for the control plane. It provides visibility into how specific protocols are segmented into distinct flows across line cards and nodes, enabling the verification of traffic policing policies that protect the router's CPU from excessive packet processing.

The MIB module for Local Packet Transport Services(LPTS) related information like the flows and the policer values related to various flows present in the system. The number of packets coming into the system is controlled by the policer values associated with the protocol. Each protocol is classified into different flows and a rate limit is associated with the flows. Policer is a numerical value controlling the number of packets entering the box. The flows represent individual, specific protocols. Flow types also represent the degree of trust for a given packet. Ex: BGP packets coming from established session is assigned one flow, packets from configured BGP peer are assigned different flow . Other BGP packets are assigned a third flow. Definitions: LPTS - Local Packet Transport Services. It is a network infrastructure subsystem that provides a common facility for transport of packets which are destined towards the router (for-us packets), to the exact applications. In addtion to that, it also provides policing of for-us packets FlowType - Represents individual, specific protocols. Flow also represents the degree of trust for a given packet. LC - Line Cards. Policer - Index to FlowType. CurrentRate - Number of packets allowed into the box in PPS (Packets Per Second). Type - Defines the scope of the flow applicable at a specific node or Line card. Precedence - Precedence is the selection mechanism for a specific Type if more than one Type is configured for the same flow. 'local' FlowType has higher precedence over 'global' and 'static' FlowTypes. 'global' FlowType has higher precedence over 'static' FlowType. nodeID - The line card for which the flow configuration is made.
Main OID:
ciscoLptsMIB.1.3.6.1.4.1.9.9.812
20
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

20 total
Object Name
ciscoLptsMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.812
ciscoLptsMIBNotifs
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.812.0
ciscoLptsMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.812.1
clGlobalFlowTable
SEQUENCE OF ClGlobalFlowEntry
.1.3.6.1.4.1.9.9.812.1.1
clGlobalFlowEntry
ClGlobalFlowEntry
.1.3.6.1.4.1.9.9.812.1.1.1
clGlobalFlowIndex
Unsigned32
.1.3.6.1.4.1.9.9.812.1.1.1.1
clGlobalFlowTypero
SnmpAdminString
.1.3.6.1.4.1.9.9.812.1.1.1.2
clGlobalTypero
ClFlowType
.1.3.6.1.4.1.9.9.812.1.1.1.3
clGlobalCurrentRaterw
Unsigned32 UNITS "PPS"
.1.3.6.1.4.1.9.9.812.1.1.1.4
clLocalFlowTable
SEQUENCE OF ClLocalFlowEntry
.1.3.6.1.4.1.9.9.812.1.2
clLocalFlowEntry
ClLocalFlowEntry
.1.3.6.1.4.1.9.9.812.1.2.1
clLocalNodeID
Unsigned32
.1.3.6.1.4.1.9.9.812.1.2.1.1
clLocalTypero
ClFlowType
.1.3.6.1.4.1.9.9.812.1.2.1.2
clLocalCurrentRatero
Unsigned32 UNITS "PPS"
.1.3.6.1.4.1.9.9.812.1.2.1.3
clLocalAcceptedro
Counter64
.1.3.6.1.4.1.9.9.812.1.2.1.4
clLocalDroppedro
Counter64
.1.3.6.1.4.1.9.9.812.1.2.1.5
clLocalTosValuero
Unsigned32
.1.3.6.1.4.1.9.9.812.1.2.1.6
ciscoLptsMIBConform
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.812.2
ciscoLptsMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.812.2.1
ciscoLptsMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.812.2.2

CISCO-LPTS-MIB Technical Reference Overview

The CISCO-LPTS-MIB SNMP MIB module published by Cisco defines 20 managed OID objects, including 10 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.812. Key tabular structures include clGlobalFlowTable, clLocalFlowTable.

Key OID Definitions in CISCO-LPTS-MIB

ciscoLptsMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.812

The MIB module for Local Packet Transport Services(LPTS) related information like the flows and the policer values related to various flows present in the system. The number of packets coming into the system is controlled by the policer values associated with the protocol. Each protocol is classified into different flows and a rate limit is associated with the flows. Policer is a numerical value controlling the number of packets entering the box. The flows represent individual, specific protocols. Flow types also represent the degree of trust for a given packet. Ex: BGP packets coming from established session is assigned one flow, packets from configured BGP peer are assigned different flow . Other BGP packets are assigned a third flow. Definitions: LPTS - Local Packet Transport Services. It is a network infrastructure subsystem that provides a common facility for transport of packets which are destined towards the router (for-us packets), to the exact applications. In addtion to that, it also provides policing of for-us packets FlowType - Represents individual, specific protocols. Flow also represents the degree of trust for a given packet. LC - Line Cards. Policer - Index to FlowType. CurrentRate - Number of packets allowed into the box in PPS (Packets Per Second). Type - Defines the scope of the flow applicable at a specific node or Line card. Precedence - Precedence is the selection mechanism for a specific Type if more than one Type is configured for the same flow. 'local' FlowType has higher precedence over 'global' and 'static' FlowTypes. 'global' FlowType has higher precedence over 'static' FlowType. nodeID - The line card for which the flow configuration is made.

clGlobalFlowTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.812.1.1

This table respresents the flows configured globally and the configuration will be reflected across all the linecards

clLocalFlowTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.812.1.2

This table represents the configurations for the local flow types & affects a particular nodeID for which config is applied. When local flow type is not configured & we have a global configuration then the clLocalFlowTable has global flow value. If neither local flow nor the global flows are configured, then clLocalFlowTable will have static values derived from the config file. If both the local flow and global flow is configured, then the local flow information takes precedence over the global flow information.

clGlobalFlowEntryClGlobalFlowEntrynot-accessible
.1.3.6.1.4.1.9.9.812.1.1.1

An entry will be added into clGlobalFlowTable when LPTS flows configured without any location specific details. Similarly when the global LPTS flow config is removed, then type and rate retained as per Static config file. The entries in this table can be of Type either 'global' or 'static'.

clGlobalFlowIndexUnsigned32not-accessible
.1.3.6.1.4.1.9.9.812.1.1.1.1

An unique value used to represent a row in the clGlobalFlowTable

clGlobalFlowTypeSnmpAdminStringread-only
.1.3.6.1.4.1.9.9.812.1.1.1.2

This object indicates the flow type name associated with every flow. Eg. FlowType could be BGP-Known, BGP-configured BGP-default.

clGlobalTypeClFlowTyperead-only
.1.3.6.1.4.1.9.9.812.1.1.1.3

This object indicates an enumeration which indicates whether LPTS flow configured across all the linecards are 'global' or 'static' depending on the predecedence

clGlobalCurrentRateUnsigned32read-write
.1.3.6.1.4.1.9.9.812.1.1.1.4

This object specifies the rate associated with the flow type which is configured globally.

clLocalFlowEntryClLocalFlowEntrynot-accessible
.1.3.6.1.4.1.9.9.812.1.2.1

An entry in clLocalFlowTable will be added when LPTS flows are configured specific to a location. This table is indexed based on nodeID and clGlobalFlowIndex. When NMS polls for flow in clLocalFlowTable, the flow name is retrieved from the clGlobalFlowTable. When a local configuration is removed for a flow, then clGlobalCurrentRate will be applied if it is present, else static rate will be applied.

clLocalNodeIDUnsigned32not-accessible
.1.3.6.1.4.1.9.9.812.1.2.1.1

The linecard for which the flow configuration is made.

clLocalTypeClFlowTyperead-only
.1.3.6.1.4.1.9.9.812.1.2.1.2

This object indicates an enumeration which indicates LPTS flows configured specific to a linecard

clLocalCurrentRateUnsigned32read-only
.1.3.6.1.4.1.9.9.812.1.2.1.3

This object indicates the packet rate associated with the flow type with which packets are accepted or dropped specific to a linecard.

clLocalAcceptedCounter64read-only
.1.3.6.1.4.1.9.9.812.1.2.1.4

This object indicates the total number of packets accepted on a linecard for a specific flow.

clLocalDroppedCounter64read-only
.1.3.6.1.4.1.9.9.812.1.2.1.5

This object indicates the total number of packets dropped on a linecard for a specific flow.

clLocalTosValueUnsigned32read-only
.1.3.6.1.4.1.9.9.812.1.2.1.6

This object indicates the type of service.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→