CISCO-L2-DEV-MONITORING-MIB
The CISCO-L2-DEV-MONITORING-MIB enables Cisco hot standby Layer 2 devices to monitor the operational status of active Layer 2 peers and configure failover parameters for switch-over events.
Imported Objects
Objects
18 total| Object Name |
|---|
ciscoL2DevMonMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.271 |
ciscoL2DevMonMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.271.0 |
cl2DevMonSwitchover NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.271.0.1 |
ciscoL2DevMonMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.271.1 |
cl2DevMonConfig OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.271.1.1 |
cl2DevMonInStandbyModerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.271.1.1.1 |
cl2DevMonNotifEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.271.1.1.2 |
cl2DevMonActiveTable SEQUENCE OF Cl2DevMonActiveEntry .1.3.6.1.4.1.9.9.271.1.1.3 |
cl2DevMonActiveEntry Cl2DevMonActiveEntry .1.3.6.1.4.1.9.9.271.1.1.3.1 |
cl2DevMonActiveMacAddress MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.9.271.1.1.3.1.1 |
cl2DevMonActivePollingFrequencyrw Unsigned32 .1.3.6.1.4.1.9.9.271.1.1.3.1.2 |
cl2DevMonActivePollingTimeOutrw Unsigned32 .1.3.6.1.4.1.9.9.271.1.1.3.1.3 |
cl2DevMonActiveRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.271.1.1.3.1.4 |
cl2DevMonActiveRadioMacTyperw Enumeration .1.3.6.1.4.1.9.9.271.1.1.3.1.5 |
cl2DevMonActiveLocalRadioIndexrw InterfaceIndex (IF-MIB) .1.3.6.1.4.1.9.9.271.1.1.3.1.6 |
ciscoL2DevMonMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.271.2 |
ciscoL2DevMonMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.271.2.1 |
ciscoL2DevMonMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.271.2.2 |
CISCO-L2-DEV-MONITORING-MIB Technical Reference Overview
The CISCO-L2-DEV-MONITORING-MIB SNMP MIB module published by Cisco defines 18 managed OID objects, including 8 scalar/column metrics, 1 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.271. Key tabular structures include cl2DevMonActiveTable. Monitored SNMP traps/notifications include cl2DevMonSwitchover.
Key OID Definitions in CISCO-L2-DEV-MONITORING-MIB
.1.3.6.1.4.1.9.9.271This MIB module is for monitoring of active layer 2 devices by hot standby layer 2 devices and the configuration of hot standby switch-over parameters.
.1.3.6.1.4.1.9.9.271.1.1.3The table for active devices on the network being monitored by the hot standby monitoring unit. This table is on the hot standby monitoring unit. All entries on this table will only be added, deleted, modified using command user interface or SNMP request.
.1.3.6.1.4.1.9.9.271.0.1This cl2DevMonSwitchover notification will only be sent when this device changes its cl2DevMonInStandbyMode to FALSE and becomes an active unit. The sending of these notifications can be enabled/disabled via the cl2DevMonNotifEnabled object.
.1.3.6.1.4.1.9.9.271.1.1.1If the value of this variable is TRUE, this device is in monitoring or standby mode and it will poll for the health of the devices on the cl2DevMonActiveTable. If the value of cl2DevMonInStandbyMode is FALSE, it only can be set back to TRUE using command line interface or SNMP request. The value can be set to FALSE only by the device itself because force switch over from standby mode to active mode is not allowed.
.1.3.6.1.4.1.9.9.271.1.1.2Indicates whether cl2DevMonSwitchover notifications will or will not be sent by the device when it changes its cl2DevMonInStandbyMode to FALSE and becomes an active unit.
.1.3.6.1.4.1.9.9.271.1.1.3.1An entry in the cl2DevMonActiveTable table.
.1.3.6.1.4.1.9.9.271.1.1.3.1.1Mac address of the active unit to be monitored by this hot standby monitoring unit.
.1.3.6.1.4.1.9.9.271.1.1.3.1.2The frequency, in seconds, the active unit specified by cl2DevMonActiveMacAddress is polled for its health.
.1.3.6.1.4.1.9.9.271.1.1.3.1.3The total time, in seconds, the standby monitoring unit can tolerate the failure of polling of the active unit. After this duration, one more failure of the polling will trigger this hot standby monitoring unit to take over and become an active unit. It then will stop monitoring other active units and set value of cl2DevMonInStandbyMode to FALSE.
.1.3.6.1.4.1.9.9.271.1.1.3.1.4The status column used for creating, modifying, and deleting instances of the columnar objects in the cl2DevMonActiveTable table. Creation of rows must be done via 'createAndGo' and all columns are mandatory. This object will become 'active' if the NMS performs a multivarbind set including this object. Any object in a row can be modified any time when the row is in the 'active' state. Removal of a row can be done via setting this object to 'destroy'.
.1.3.6.1.4.1.9.9.271.1.1.3.1.5If the device being monitored is a IEEE 802.11 Wireless device, cl2DevMonActiveMacAddress is the remote device radio MAC address and this is the type of IEEE 802.11 Standard applies that radio: ieee802dot11a(1) - IEEE 802.11a Standard, ieee802dot11b(2) - IEEE 802.11b Standard, ieee802dot11g(3) - IEEE 802.11g Standard. If the device being monitored is not a IEEE 802.11 Wireless device, the default value for this object is '0'.
.1.3.6.1.4.1.9.9.271.1.1.3.1.6If the device being monitored is a IEEE 802.11 Wireless LAN device, this is the ifIndex of a local radio of ifType ieee80211(71) used for the monitoring. If the local radio only supports to monitor only one remote radio, adding or updating multiple rows to the same ifIndex is not allowed.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.