Home/Catalog/CISCO-ISNS-CLIENT-MIB

CISCO-ISNS-CLIENT-MIB

AI MIB Summary

The CISCO-ISNS-CLIENT-MIB enables the monitoring and configuration of Cisco iSNS client entities to manage Fibre Channel over Ethernet (FCoE) storage discovery, registration, and session state parameters. It provides visibility into critical iSNS client metrics, including registered storage nodes, active discovery sessions, and client registration status within the storage area network.

MIB module for monitoring and configuring Internet Storage Name Service (iSNS) client.
Main OID:
ciscoIsnsClientMIB.1.3.6.1.4.1.9.9.372
15
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

15 total
Object Name
ciscoIsnsClientMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.372
ciscoIsnsClientMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.372.0
ciscoIsnsClientMIBMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.372.1
cIsnsClientConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.372.1.1
cIsnsClntServerProfileTable
SEQUENCE OF CIsnsClntServerProfileEntry
.1.3.6.1.4.1.9.9.372.1.1.1
cIsnsClntServerProfileEntry
CIsnsClntServerProfileEntry
.1.3.6.1.4.1.9.9.372.1.1.1.1
cIsnsClntServerProfileName
SnmpAdminString
.1.3.6.1.4.1.9.9.372.1.1.1.1.1
cIsnsClntServerIndex
Unsigned32
.1.3.6.1.4.1.9.9.372.1.1.1.1.2
cIsnsClntServerProfileAddrTyperw
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.372.1.1.1.1.3
cIsnsClntServerProfileAddrrw
InetAddress (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.372.1.1.1.1.4
cIsnsClntServerProfilePortrw
CiscoPort (CISCO-TC)
.1.3.6.1.4.1.9.9.372.1.1.1.1.5
cIsnsClntServerProfileStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.372.1.1.1.1.6
ciscoIsnsClientMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.372.2
ciscoiIsnsClientMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.372.2.1
ciscoIsnsClientMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.372.2.2

CISCO-ISNS-CLIENT-MIB Technical Reference Overview

The CISCO-ISNS-CLIENT-MIB SNMP MIB module published by Cisco defines 15 managed OID objects, including 6 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.372. Key tabular structures include cIsnsClntServerProfileTable.

Key OID Definitions in CISCO-ISNS-CLIENT-MIB

ciscoIsnsClientMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.372

MIB module for monitoring and configuring Internet Storage Name Service (iSNS) client.

cIsnsClntServerProfileTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.372.1.1.1

This table lists iSNS server profile configured on the local device.

cIsnsClntServerProfileEntryCIsnsClntServerProfileEntrynot-accessible
.1.3.6.1.4.1.9.9.372.1.1.1.1

An entry representing an iSNS server profile.

cIsnsClntServerProfileNameSnmpAdminStringnot-accessible
.1.3.6.1.4.1.9.9.372.1.1.1.1.1

An arbitrary string value, which identifies an iSNS server profile.

cIsnsClntServerIndexUnsigned32not-accessible
.1.3.6.1.4.1.9.9.372.1.1.1.1.2

An arbitrary integer value, which identifies an iSNS server for this profile.

cIsnsClntServerProfileAddrTypeInetAddressTyperead-create
.1.3.6.1.4.1.9.9.372.1.1.1.1.3

The address type of the iSNS server.

cIsnsClntServerProfileAddrInetAddressread-create
.1.3.6.1.4.1.9.9.372.1.1.1.1.4

The address of the iSNS server.

cIsnsClntServerProfilePortCiscoPortread-create
.1.3.6.1.4.1.9.9.372.1.1.1.1.5

The port of the iSNS server.

cIsnsClntServerProfileStatusRowStatusread-create
.1.3.6.1.4.1.9.9.372.1.1.1.1.6

Status of this row.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→