CISCO-IP-URPF-MIB
The CISCO-IP-URPF-MIB monitors Cisco IOS devices to track Unicast Reverse Path Forwarding (URPF) enforcement events, specifically counting spoofed packets dropped by strict or loose source address validation checks. It provides visibility into URPF violation counters and interface-specific routing validity states to detect and mitigate IP address spoofing attacks.
Imported Objects
Objects
41 total| Object Name |
|---|
ciscoIpUrpfMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.451 |
ciscoIpUrpfMIBNotifs OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.451.0 |
cipUrpfIfDropRateNotify NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.451.0.1 |
ciscoIpUrpfMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.451.1 |
cipUrpfScalar OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.451.1.1 |
cipUrpfDropRateWindowrw Integer32 .1.3.6.1.4.1.9.9.451.1.1.1 |
cipUrpfComputeIntervalrw Integer32 .1.3.6.1.4.1.9.9.451.1.1.2 |
cipUrpfDropNotifyHoldDownTimerw Integer32 .1.3.6.1.4.1.9.9.451.1.1.3 |
cipUrpfStatistics OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.451.1.2 |
cipUrpfTable SEQUENCE OF CipUrpfEntry .1.3.6.1.4.1.9.9.451.1.2.1 |
cipUrpfEntry CipUrpfEntry .1.3.6.1.4.1.9.9.451.1.2.1.1 |
cipUrpfIpVersion Enumeration .1.3.6.1.4.1.9.9.451.1.2.1.1.1 |
cipUrpfDropsro Counter32 UNITS "packets" .1.3.6.1.4.1.9.9.451.1.2.1.1.2 |
cipUrpfDropRatero Gauge32 UNITS "packets per second" .1.3.6.1.4.1.9.9.451.1.2.1.1.3 |
cipUrpfIfMonTable SEQUENCE OF CipUrpfIfMonEntry .1.3.6.1.4.1.9.9.451.1.2.2 |
cipUrpfIfMonEntry CipUrpfIfMonEntry .1.3.6.1.4.1.9.9.451.1.2.2.1 |
cipUrpfIfIpVersion Enumeration .1.3.6.1.4.1.9.9.451.1.2.2.1.1 |
cipUrpfIfDropsro Counter32 UNITS "packets" .1.3.6.1.4.1.9.9.451.1.2.2.1.2 |
cipUrpfIfSuppressedDropsro Counter32 UNITS "packets" .1.3.6.1.4.1.9.9.451.1.2.2.1.3 |
cipUrpfIfDropRatero Gauge32 UNITS "packets/second" .1.3.6.1.4.1.9.9.451.1.2.2.1.4 |
cipUrpfIfDiscontinuityTimero TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.9.9.451.1.2.2.1.5 |
cipUrpfVrfIfTable SEQUENCE OF CipUrpfVrfIfEntry .1.3.6.1.4.1.9.9.451.1.2.3 |
cipUrpfVrfIfEntry CipUrpfVrfIfEntry .1.3.6.1.4.1.9.9.451.1.2.3.1 |
cipUrpfVrfIfDropsro Counter32 UNITS "packets" .1.3.6.1.4.1.9.9.451.1.2.3.1.2 |
cipUrpfVrfIfDiscontinuityTimero TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.9.9.451.1.2.3.1.3 |
cipUrpfInterfaceConfig OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.451.1.3 |
cipUrpfIfConfTable SEQUENCE OF CipUrpfIfConfEntry .1.3.6.1.4.1.9.9.451.1.3.1 |
cipUrpfIfConfEntry CipUrpfIfConfEntry .1.3.6.1.4.1.9.9.451.1.3.1.1 |
cipUrpfIfDropRateNotifyEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.451.1.3.1.1.1 |
cipUrpfIfNotifyDropRateThresholdrw Unsigned32 UNITS "packets/second" .1.3.6.1.4.1.9.9.451.1.3.1.1.2 |
cipUrpfIfNotifyDrHoldDownResetrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.451.1.3.1.1.3 |
cipUrpfIfCheckStrictro Enumeration .1.3.6.1.4.1.9.9.451.1.3.1.1.4 |
cipUrpfIfWhichRouteTableIDro Enumeration .1.3.6.1.4.1.9.9.451.1.3.1.1.5 |
cipUrpfIfVrfNamero SnmpAdminString .1.3.6.1.4.1.9.9.451.1.3.1.1.6 |
cipUrpfVrf OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.451.1.4 |
cipUrpfVrfTable SEQUENCE OF CipUrpfVrfEntry .1.3.6.1.4.1.9.9.451.1.4.1 |
cipUrpfVrfEntry CipUrpfVrfEntry .1.3.6.1.4.1.9.9.451.1.4.1.1 |
cipUrpfVrfNamero SnmpAdminString .1.3.6.1.4.1.9.9.451.1.4.1.1.1 |
ciscoIpUrpfMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.451.2 |
ciscoIpUrpfMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.451.2.1 |
ciscoIpUrpfMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.451.2.2 |
CISCO-IP-URPF-MIB Technical Reference Overview
The CISCO-IP-URPF-MIB SNMP MIB module published by Cisco defines 41 managed OID objects, including 21 scalar/column metrics, 5 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.451. Key tabular structures include cipUrpfTable, cipUrpfIfMonTable, cipUrpfIfConfTable, cipUrpfVrfTable, cipUrpfVrfIfTable. Monitored SNMP traps/notifications include cipUrpfIfDropRateNotify.
Key OID Definitions in CISCO-IP-URPF-MIB
.1.3.6.1.4.1.9.9.451Unicast Reverse Path Forwarding (URPF) is a function that checks the validity of the source address of IP packets received on an interface. This in an attempt to prevent Denial of Service attacks based on IP address spoofing. URPF checks validity of a source address by determining whether the packet would be successfully routed as a destination address. Based on configuration, the check made can be for existence of any route for the address, or more strictly for a route out the interface on which the packet was received by the device. When a violating packet is detected, it can be dropped. This MIB allows detection of spoofingevents.
.1.3.6.1.4.1.9.9.451.1.2.1This table contains summary information for the managed device on URPF dropping.
.1.3.6.1.4.1.9.9.451.1.2.2This table contains information on URPF dropping on an interface.
.1.3.6.1.4.1.9.9.451.1.3.1This table contains statistics information on URPF on an interface.
.1.3.6.1.4.1.9.9.451.1.4.1This table enables indexing URPF drop statistics by Virtual Routing and Forwarding instances.
.1.3.6.1.4.1.9.9.451.1.2.3This table contains statistics information for interfaces performing URPF using VRF table to determine reachability.
.1.3.6.1.4.1.9.9.451.0.1This notification is generated when cipUrpfIfDropRateNotifyEnable is set to true and the calculated URPF drop rate (cipUrpfIfDropRate) exceeds the notification threshold drop rate (cipUrpfIfNotifyDropRateThreshold). Note the exceptional value of 0 for threshold allows notification generation if any drop events occur in an interval. After generating this notification, another such notification will not be sent out for a minimum of five minutes (note the exception to this provided by cipUrpfIfNotifyDrHoldDownReset). The object value present in the notification is the the drop rate that exceeded the threshold.
.1.3.6.1.4.1.9.9.451.1.1.1The window of time in the recent past over which the drop count used in the drop rate computation is collected. This global value applies for the computation of all URPF rates, global and per-interface. Once the period over which computations have been performed exceeds cipUrpfDropRateWindow, every time a computation is performed, the window slides up to end at the current time and start at cipUrpfDropRateWindow seconds before. The cipUrpfDropRateWindow must be greater than or equal to the interval between computations (cipUrpfComputeInterval). Since the agent must save the drop count values for each compute interval in order to slide the window, the number of counts saved is the quotient of cipUrpfDropRateWindow divided by cipUrpfComputeInterval.
.1.3.6.1.4.1.9.9.451.1.1.2The time between rate computations. This global value applies for the computation of all URPF rates, global and per-interface. When the value of cipUrpfComputeInterval is changed, the interval in-progress proceeds as though the value had not changed. The change will apply to the length of subsequent intervals. The cipUrpfComputeInterval must be less than or equal to the cipUrpfDropRateWindow.
.1.3.6.1.4.1.9.9.451.1.1.3The minimum time between issuance of cipUrpfIfDropRateNotify notifications for a particular interface and packet forwarding type. Notifications are generated for each interface and packet forwarding type that exceeds the drop-rate. When a Notify is sent because the drop-rate is exceeded for a particular interface and forwarding type, the time specified by this object is used to specify the minimum time that must elapse before another Notify can be sent for that interface and forwarding type. The time is specified globally but used individually.
.1.3.6.1.4.1.9.9.451.1.3.1.1A row exists in this table if a row exists in cipUrpfIfMonTable.
.1.3.6.1.4.1.9.9.451.1.3.1.1.1This object specifies whether the system produces the cipUrpfIfDropRateNotify notification as a result of URPF dropping of version cipUrpfIfIpVersion IP packets on this interface. A false value prevents such notifications from being generated by this system.
.1.3.6.1.4.1.9.9.451.1.3.1.1.2When the calculated rate of URPF packet drops (cipUrpfIfDropRate) meets or exceeds the value specified by this object, a cipUrpfIfDropRateNotify notification is sent if cipUrpfIfDropRateNotifyEnable is set to true, and no such notification for the IP version has been sent for this interface for the hold-down period. Note that due to the calculation used for drop rate, if there are less than n drop events in an n-second period the notification will not be generated. To allow for the detection of a small number of drop events, the value 0 (zero) is used to indicate that if any drop events occur during the interval, a notification is generated.
.1.3.6.1.4.1.9.9.451.1.3.1.1.3Setting this object to true causes the five-minute hold-down timer for emitting URPF drop rate notifications for IP version cipUrpfIfIpVersion on the interface to be short-circuited. If a notification is due and would be emitted for the interface if the five-minutes elapsed, setting this object will cause the notification to be sent. This is a trigger, and doesn't hold information. It is set and an action is performed. Therefore a get for this object always returns false.
.1.3.6.1.4.1.9.9.451.1.3.1.1.4Interface configuration indicating the strictness of the reachability check performed on the interface. - strict: check that source addr is reachable via the interface it came in on. - loose : check that source addr is reachable via some interface on the device.
.1.3.6.1.4.1.9.9.451.1.3.1.1.5Interface configuration indicating the routing table consulted for the reachability check: - default: the non-private routing table for of the managed system. - vrf : a particular VPN routing table.
.1.3.6.1.4.1.9.9.451.1.3.1.1.6If the value of cipUrpfIfWhichRouteTableID is 'vrf', the name of the VRF Table. Otherwise a zero-length string.
.1.3.6.1.4.1.9.9.451.1.2.1.1If the managed device supports URPF dropping, a row exists for each IP version type (v4 and v6). A row contains summary information on URPF dropping over the entire managed device.
.1.3.6.1.4.1.9.9.451.1.2.1.1.1Specifies the version of IP forwarding on an interface to which the table row URPF counts, rates, and configuration apply.
.1.3.6.1.4.1.9.9.451.1.2.1.1.2Sum of dropped IP version cipUrpfIpVersion packets failing a URPF check. This value is the sum of drops of packets received on all interfaces of the managed device.
.1.3.6.1.4.1.9.9.451.1.2.1.1.3The rate of packet drops of IP version cipUrpfIpVersion packets due to URPF for the managed device. The per-interface drop rate notification is issued on rates exceeding a limit (rising rate). This dropping may indicate an security attack on the network. To determine whether the attack/event is over, the NMS must consult the managed device. This object can be polled to determine the recent drop rate for the managed device as a whole, in addition to querying particular interface objects. This object is the average rate of dropping over the most recent window of time. The rate is computed by dividing the number of packets dropped over a window by the window time in seconds. The window time is specified by cipUrpfDropRateWindow. Each time the drop rate is computed, and at system startup, a snapshot is taken of the latest value of cipUrpfDrops. Subtracting from this the snapshot of cipUrpfDrops at the start of the current window of time gives the number of packets dropped. The drop rate is computed every cipUrpfComputeInterval seconds. As an example, let cipUrpfDropRateWindow be 300 seconds, and cipUrpfComputeInterval 30 seconds. Every 30 seconds, the drop count five minutes previous is subtracted from the current drop count, and the result is divided by 300 to arrive at the drop rate. At device start-up, until the device has been up more than cipUrpfDropRateWindow, when drop rate is computed, the value of cipUrpfDrops is divided by the time the device has been up. After the device has been up for cipUrpfDropRateWindow, when drop rate is computed, the number of packet drops counted from interval start time to the computation time is divided by cipUrpfDropRateWindow. Changes to cipUrpfDropRateWindow are not reflected in this object until the next computation time. The rate from the most recent computation is the value fetched until the subsequent computation is performed.
.1.3.6.1.4.1.9.9.451.1.2.2.1If IPv4 packet forwarding is configured on an interface, and is configured to perform URPF checking, a row appears in this table with indices [ifIndex][ipv4]. If IPv4 packet forwarding is deconfigured, or URPF checking is deconfigured, the row disappears. If IPv6 packet forwarding is configured on an interface, and is configured to perform URPF checking, a row appears in the table with indices [ifIndex][ipv6]. If IPv6 packet forwarding is deconfigured, or URPF checking is deconfigured, the row disappears.
.1.3.6.1.4.1.9.9.451.1.2.2.1.1Specifies the version of IP forwarding on an interface to which the table row URPF counts, rates, and configuration apply.
.1.3.6.1.4.1.9.9.451.1.2.2.1.2The number of IP packets of version cipUrpfIfIpVersion failing the URPF check and dropped by the managed device on a particular interface. Discontinuities in the value of this variable can occur at re-initialization of the management system, and at other times as indicated by the values of cipUrpfIfDiscontinuityTime.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.