CISCO-IF-THRESHOLD-MIB

AI MIB Summary

The CISCO-IF-THRESHOLD-MIB enables Cisco network devices to centrally configure and monitor interface traffic thresholds via reusable templates applied to specific interface subsets. It facilitates granular alerting for bandwidth utilization or error rates across selected ports, serving as a scalable alternative to per-interface or global monitoring when managing large-scale network segments.

This MIB module defines the managed objects that support monitoring of thresholds on interfaces. Configuration and monitoring of the thresholds is done through threshold templates that can be assigned to any subset of interfaces on the network element. More than one threshold template can be assigned to a given interface. This MIB module should be used when it is desired to apply a common set of thresholds to a subset of the available interfaces. If a threshold is to be applied to only one interface, then the EVENT-MIB or the RMON-MIB may be used as simpler alternatives. If a threshold is to be applied to all available interfaces, then the EVENT-MIB may be used as a simpler alternative.
Main OID:
ciscoIfThresholdMIB.1.3.6.1.4.1.9.9.218
52
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

52 total
Object Name
ciscoIfThresholdMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.218
cIfThresholdMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.218.1
cifthTemplateGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.218.1.1
cifthTemplateIndexNextro
CifthTemplateIndexOrZero
.1.3.6.1.4.1.9.9.218.1.1.1
cifthTemplateLastChangero
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.218.1.1.2
cifthTemplateTable
SEQUENCE OF CifthTemplateEntry
.1.3.6.1.4.1.9.9.218.1.1.3
cifthTemplateEntry
CifthTemplateEntry
.1.3.6.1.4.1.9.9.218.1.1.3.1
cifthTemplateIndex
CifthTemplateIndex
.1.3.6.1.4.1.9.9.218.1.1.3.1.1
cifthTemplateNamerw
SnmpAdminString
.1.3.6.1.4.1.9.9.218.1.1.3.1.2
cifthTemplateNotifyHoldDownTyperw
Enumeration
.1.3.6.1.4.1.9.9.218.1.1.3.1.3
cifthTemplateNotifyHoldDownTimerw
Unsigned32
.1.3.6.1.4.1.9.9.218.1.1.3.1.4
cifthTemplateRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.218.1.1.3.1.5
cifthThresholdLastChangero
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.218.1.1.4
cifthThresholdTable
SEQUENCE OF CifthThresholdEntry
.1.3.6.1.4.1.9.9.218.1.1.5
cifthThresholdEntry
CifthThresholdEntry
.1.3.6.1.4.1.9.9.218.1.1.5.1
cifthThresholdIndex
CifthThresholdIndex
.1.3.6.1.4.1.9.9.218.1.1.5.1.1
cifthThresholdDescrrw
SnmpAdminString
.1.3.6.1.4.1.9.9.218.1.1.5.1.2
cifthThresholdObjectrw
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.218.1.1.5.1.3
cifthThresholdSeverityrw
CifthThresholdSeverity
.1.3.6.1.4.1.9.9.218.1.1.5.1.4
cifthThresholdTyperw
Enumeration
.1.3.6.1.4.1.9.9.218.1.1.5.1.5
cifthThresholdDirectionrw
Enumeration
.1.3.6.1.4.1.9.9.218.1.1.5.1.6
cifthThresholdFiredValuerw
Integer32 (-2147483648..2147483647)
.1.3.6.1.4.1.9.9.218.1.1.5.1.7
cifthThresholdClearedValuerw
Integer32 (-2147483648..2147483647)
.1.3.6.1.4.1.9.9.218.1.1.5.1.8
cifthThresholdSampleIntervalrw
Unsigned32
.1.3.6.1.4.1.9.9.218.1.1.5.1.9
cifthThresholdApsSwitchoverrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.218.1.1.5.1.10
cifthThresholdRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.218.1.1.5.1.11
cifthTemplateIfAssignGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.218.1.2
cifthTemplateIfLastChangero
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.218.1.2.1
cifthTemplateIfAssignTable
SEQUENCE OF CifthTemplateIfAssignEntry
.1.3.6.1.4.1.9.9.218.1.2.2
cifthTemplateIfAssignEntry
CifthTemplateIfAssignEntry
.1.3.6.1.4.1.9.9.218.1.2.2.1
cifthTemplateIfAssignInterface
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.9.9.218.1.2.2.1.1
cifthTemplateIfAssignOperStatusro
Enumeration
.1.3.6.1.4.1.9.9.218.1.2.2.1.2
cifthTemplateIfAssignRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.218.1.2.2.1.3
cifthIfThresholdFiredGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.218.1.3
cifthThresholdFiredNotifyEnablerw
CifthThresholdSeverityOrZero
.1.3.6.1.4.1.9.9.218.1.3.1
cifthThresholdFiredLastChangero
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.218.1.3.2
cifthIfThresholdFiredTable
SEQUENCE OF CifthIfThresholdFiredEntry
.1.3.6.1.4.1.9.9.218.1.3.3
cifthIfThresholdFiredEntry
CifthIfThresholdFiredEntry
.1.3.6.1.4.1.9.9.218.1.3.3.1
cifthIfThresholdFiredTemplate
CifthTemplateIndex
.1.3.6.1.4.1.9.9.218.1.3.3.1.1
cifthIfThresholdsFiredro
CifthThresholdList
.1.3.6.1.4.1.9.9.218.1.3.3.1.2
cifthIfLastThresholdFiredro
CifthThresholdIndex
.1.3.6.1.4.1.9.9.218.1.3.3.1.3
cifthIfThresholdFiredLstChangero
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.218.1.3.3.1.4
cifthIfThresholdFiredLstSeverityro
CifthThresholdSeverity
.1.3.6.1.4.1.9.9.218.1.3.3.1.5
cifthIfThresholdFiredMaxSeverityro
CifthThresholdSeverity
.1.3.6.1.4.1.9.9.218.1.3.3.1.6
cIfThresholdMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.218.2
cifthMIBNotificationsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.218.2.0
cifthIfThresholdFired
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.218.2.0.1
cifthIfThresholdCleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.218.2.0.2
cifthTemplateIfStatusChange
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.218.2.0.3
cIfThresholdMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.218.3
cIfThresholdMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.218.3.1
cIfThresholdMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.218.3.2

CISCO-IF-THRESHOLD-MIB Technical Reference Overview

The CISCO-IF-THRESHOLD-MIB SNMP MIB module published by Cisco defines 52 managed OID objects, including 31 scalar/column metrics, 4 SNMP tables, and 3 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.218. Key tabular structures include cifthTemplateTable, cifthThresholdTable, cifthTemplateIfAssignTable, cifthIfThresholdFiredTable. Monitored SNMP traps/notifications include cifthIfThresholdFired, cifthIfThresholdCleared, cifthTemplateIfStatusChange.

Key OID Definitions in CISCO-IF-THRESHOLD-MIB

ciscoIfThresholdMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.218

This MIB module defines the managed objects that support monitoring of thresholds on interfaces. Configuration and monitoring of the thresholds is done through threshold templates that can be assigned to any subset of interfaces on the network element. More than one threshold template can be assigned to a given interface. This MIB module should be used when it is desired to apply a common set of thresholds to a subset of the available interfaces. If a threshold is to be applied to only one interface, then the EVENT-MIB or the RMON-MIB may be used as simpler alternatives. If a threshold is to be applied to all available interfaces, then the EVENT-MIB may be used as a simpler alternative.

cifthTemplateTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.218.1.1.3

This table is used to create threshold templates. Each template includes one or more thresholds (defined in the cifthThresholdTable), and can be assigned to multiple interfaces. An interface may be associated with more than one template. The assignment of templates to interfaces is done in the cifthTemplateIfAssignTable.

cifthThresholdTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.218.1.1.5

This table specifies the interface thresholds used in each template.

cifthTemplateIfAssignTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.218.1.2.2

This table specifies the assignment of threshold templates to specific interfaces. Each threshold template may be assigned to multiple interfaces. Each interface may have multiple threshold templates assigned to it.

cifthIfThresholdFiredTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.218.1.3.3

This table indicates the interfaces that currently have threshold fired conditions.

cifthIfThresholdFiredNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.218.2.0.1

The agent generates this notification when a threshold defined in a template is asserted on an interface. If a threshold is asserted for a given interface and template, cifthTemplateNotifyHoldDownTime is set to 'holdDownTimer' for that template, and this notification has recently been sent for the same threshold on the same interface, then this notification may be suppressed.

cifthIfThresholdClearedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.218.2.0.2

The agent generates this notification when a threshold, that has previously fired, is cleared on an interface. If a threshold is cleared for a given interface and template, cifthTemplateNotifyHoldDownTime is set to 'holdDownTimer' for that template, and this notification has recently been sent for the same threshold on the same interface, then this notification may be suppressed.

cifthTemplateIfStatusChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.218.2.0.3

The agent generates this notification when a template comes up or goes down on an interface to which it is assigned, i.e., when the value of cifthTemplateIfAssignOperStatus changes. If a template becomes operationally down on an interface upon activation of a new entry in the cifthTemplateIfAssignTable, the agent generates this notification. The agent need not generate this notification when a new entry in the cifthTemplateIfAssignTable is activated, if the template becomes operational on the interface. The agent need not generate this notification when an entry in the cifthTemplateIfAssignTable is destroyed.

cifthTemplateIndexNextCifthTemplateIndexOrZeroread-only
.1.3.6.1.4.1.9.9.218.1.1.1

This object contains an appropriate value to be used for cifthTemplateIndex when creating entries in the cifthTemplateTable. The distinguished value 0 indicates that no unassigned entries are available. To obtain a suggested cifthTemplateIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. The manager may ignore this object and use alternative mechanisms for choosing an unused value of cifthTemplateIndex for a new entry. The agent will modify the value to the next unassigned index, when a new entry is created in cifthTemplateTable with the current value of this object. After deletion of an entry in cifthTemplateTable the agent will determine through its local policy when its index value will be made available for reuse.

cifthTemplateLastChangeTimeStampread-only
.1.3.6.1.4.1.9.9.218.1.1.2

This object specifies the value of sysUpTime at the last time there was either a change to any object in any entry in cifthTemplateTable, or an entry was created or destroyed in cifthTemplateTable. If no change to cifthTemplateTable has occurred since the last re-initialization of the local network management subsystem, then this object contains a zero value.

cifthThresholdLastChangeTimeStampread-only
.1.3.6.1.4.1.9.9.218.1.1.4

This object specifies the value of sysUpTime at the last time there was either a change to any object in any entry in cifthThresholdTable, or an entry was created or destroyed in cifthThresholdTable. If no change to cifthThresholdTable has occurred since the last re-initialization of the local network management subsystem, then this object contains a zero value.

cifthTemplateIfLastChangeTimeStampread-only
.1.3.6.1.4.1.9.9.218.1.2.1

This object specifies the value of sysUpTime at the last time there was either a change to any object in any entry in cifthTemplateIfAssignTable, or an entry was created or destroyed in cifthTemplateIfAssignTable. If no change to cifthTemplateIfAssignTable has occurred since the last re-initialization of the local network management subsystem, then this object contains a zero value.

cifthThresholdFiredNotifyEnableCifthThresholdSeverityOrZeroread-write
.1.3.6.1.4.1.9.9.218.1.3.1

This object specifies the minimum severity threshold governing the generation of cifthIfThresholdFired and cifthIfThresholdCleared notifications. For example, if the value of this object is set to 'degrade', then the agent generates these notifications if and only if the severity of the threshold being exceeded is 'degrade' or 'fail'. When the value is other than '0', the generation of cifthTemplateIfStatusChange notifications is also enabled. The value of '0' disables the generation of all notifications. By default, the value of this object is set to '0'.

cifthThresholdFiredLastChangeTimeStampread-only
.1.3.6.1.4.1.9.9.218.1.3.2

This object specifies the value of sysUpTime at the last time there was either a change to any object in any entry in cifthIfThresholdFiredTable, or an entry was added or deleted in cifthIfThresholdFiredTable. If no change to cifthIfThresholdFiredTable has occurred since the last re-initialization of the local network management subsystem, then this object contains a zero value.

cifthTemplateEntryCifthTemplateEntrynot-accessible
.1.3.6.1.4.1.9.9.218.1.1.3.1

An entry describing the general properties of a threshold template. The template is created using the cifthTemplateRowStatus object. Prior to creating an entry in the table, the manager should obtain a unique value of cifthTemplateIndex by reading the cifthTemplateIndexNext object. The values of cifthTemplateName and cifthTemplateNotifyHoldDownType must be provided before activating the entry. After creating an entry, thresholds can be defined for the template by creating entries with the same value of cifthTemplateIndex in the cifthThresholdTable. The template can then be assigned to one or more interfaces using the cifthTemplateIfAssignTable. Once an entry has been activated, the value of cifthTemplateName cannot be modified. In order to use a new value of cifthTemplateName, a new template must be defined. The values of cifthTemplateNotifyHoldDownType and cifthTemplateNotifyHoldDownTime may be modified when the entry is active. See the description clause of cifthTemplateNotifyHoldDownType for further caveats on modification of that object.

cifthTemplateIndexCifthTemplateIndexnot-accessible
.1.3.6.1.4.1.9.9.218.1.1.3.1.1

An arbitrary integer that uniquely identifies a threshold template. The value for each threshold template must remain constant at least from one re-initialization of the agent's network management system to the next re-initialization. The value may change when the agent's network management system is rebooted or re-initialized.

cifthTemplateNameSnmpAdminStringread-create
.1.3.6.1.4.1.9.9.218.1.1.3.1.2

This object specifies a unique name associated with the threshold template by the management client, and provides a non-volatile 'handle' for the template. The name must not include whitespace characters. After this value has been written to the startup configuration, the agent must retain the value until a management client deletes it. The level of retention must span reboots and re-initializations of the agent, including those that result in different assignments to the value of cifthTemplateIndex associated with this template. Once an entry has been activated, this value cannot be modified. In order to use a new value of cifthTemplateName, a new template must be defined.

cifthTemplateNotifyHoldDownTypeINTEGERread-create
.1.3.6.1.4.1.9.9.218.1.1.3.1.3

This object specifies the method used to prevent an excess of notifications from being generated when operation fluctuates around a threshold level. The value 'holdDownTimer' indicates that notifications for a given threshold and interface are suppressed for a short amount of time after each notification. The time value is specified in cifthTemplateNotifyHoldDownTime, which is instantiated only when this object is set to 'holdDownTimer'. After a notification is received for a given threshold and interface, the next notification for that threshold and interface will be generated after at least cifthTemplateNotifyHoldDownTime amount of time has passed, only when the threshold is next fired or cleared. The value 'fireAndClearThresholds' indicates that hysteresis is used. The management client configures two values for each threshold: one for asserting that the threshold has been exceeded (see cifthThresholdFiredValue), and a second value for asserting that the threshold is no longer being exceeded (see cifthThresholdClearedValue, which is instantiated only when this object is set to 'fireAndClearThresholds'). When this entry in cifthTemplateTable is active, this object may only be modified if there are no active entries in cifthThresholdTable with the same value of cifthTemplateIndex.

cifthTemplateNotifyHoldDownTimeUnsigned32read-create
.1.3.6.1.4.1.9.9.218.1.1.3.1.4

The minimum amount of time between successive cifthIfThresholdFired or cifthIfThresholdCleared notifications for a given interface and template. This object is instantiated only when cifthTemplateNotifyHoldDownType is set to 'holdDownTimer'.

cifthTemplateRowStatusRowStatusread-create
.1.3.6.1.4.1.9.9.218.1.1.3.1.5

This object is used to create and delete threshold templates. The values of cifthTemplateName and cifthTemplateNotifyHoldDownType must be provided before activating the entry. An entry can only be deleted when there are no active entries in the cifthTemplateIfAssignTable with the same value of cifthTemplateIndex. When an entry is deleted, all associated entries in the cifthThresholdTable are also deleted. After the entry has been activated, this object cannot be set to any value other than 'destroy'. The row status never changes to 'notInService' after reaching the value 'active'.

cifthThresholdEntryCifthThresholdEntrynot-accessible
.1.3.6.1.4.1.9.9.218.1.1.5.1

An entry specifying an interface threshold used in a threshold template. The entry is created using the cifthThresholdRowStatus object. The values of cifthThresholdObject, cifthThresholdSeverity, cifthThresholdType, and cifthThresholdFiredValue must be provided before activating the entry. If the value of cifthTemplateNotifyHoldDownType in the cifthTemplateEntry with the same value of cifthTemplateIndex is 'fireAndClearThresholds', then the value of cifthThresholdClearedValue must also be provided before activating the entry. If the value of cifthThresholdType is other than 'rateOfIncreaseExponentXIfSpeed', then the value of cifthThresholdSampleInterval must also be provided before activating the entry. The agent should not allow creation of two entries in the table with the same values of cifthTemplateIndex, cifthThresholdObject, cifthThresholdSeverity, and cifthThresholdDirection. Once an entry has been activated, the values of cifthThresholdObject, cifthThresholdSeverity, cifthThresholdType, and cifthThresholdDirection cannot be modified. In order to use new values of these objects, a new threshold must be defined. The values of cifthThresholdDescr, cifthThresholdFiredValue, cifthThresholdClearedValue, cifthThresholdSampleInterval, and cifthThresholdApsSwitchover may be modified when the entry is active.

cifthThresholdIndexCifthThresholdIndexnot-accessible
.1.3.6.1.4.1.9.9.218.1.1.5.1.1

An arbitrary integer that uniquely identifies a threshold in a threshold template. The value for each threshold must remain constant when the agent's network management system is rebooted or re-initialized.

cifthThresholdDescrSnmpAdminStringread-create
.1.3.6.1.4.1.9.9.218.1.1.5.1.2

A description of the threshold's function and use. The description must not include carriage returns.

cifthThresholdObjectOBJECTread-create
.1.3.6.1.4.1.9.9.218.1.1.5.1.3

The object to be compared against the threshold values. The object must be defined in a table indexed only by ifIndex. All of the instance portion of the object identifier is truncated, since the instance(s) to be compared against the threshold are identified using the cifthTemplateIfAssignTable. If the object has syntax 'Integer32', 'Unsigned32', or 'Gauge32', then cifthThresholdType should be set to 'absoluteValue'. If the object has syntax 'Counter32' or 'Counter64', then cifthThresholdType should be set to 'deltaValue' or 'rateOfIncreaseExponentXIfSpeed'.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→