CISCO-IF-MONITOR-NOTIF-MIB
The CISCO-IF-MONITOR-NOTIF-MIB module enables Cisco IOS and IOS-XE devices to generate SNMP traps when interface error counters exceed defined thresholds over a specified interval, signaling severe link degradation or failure conditions.
Imported Objects
Objects
16 total| Object Name |
|---|
ciscoIfMonitorNotifMIB MODULE-IDENTITY .1.3.6.1.4.1.9.10.999 |
cIfMonNotifMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.999.0 |
cIfMonNotifEvent NOTIFICATION-TYPE .1.3.6.1.4.1.9.10.999.0.1 |
cIfMonNotifMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.999.1 |
cIfMonNotifCountro Unsigned32 .1.3.6.1.4.1.9.10.999.1.1 |
cIfMonNotifTable SEQUENCE OF CIfMonNotifEntry .1.3.6.1.4.1.9.10.999.1.2 |
cIfMonNotifEntry CIfMonNotifEntry .1.3.6.1.4.1.9.10.999.1.2.1 |
cIfMonNotifLastChangero TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.9.10.999.1.2.1.1 |
cIfMonNotifSeverityro Enumeration .1.3.6.1.4.1.9.10.999.1.2.1.2 |
cIfMonNotifCausero Enumeration .1.3.6.1.4.1.9.10.999.1.2.1.3 |
cIfMonNotifValuero Unsigned32 .1.3.6.1.4.1.9.10.999.1.2.1.4 |
cIfMonNotifThresholdro Unsigned32 .1.3.6.1.4.1.9.10.999.1.2.1.5 |
cIfMonNotifIntervalro Unsigned32 .1.3.6.1.4.1.9.10.999.1.2.1.6 |
cIfMonNotifMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.999.2 |
cIfMonNotifMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.999.2.1 |
cIfMonNotifMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.999.2.2 |
CISCO-IF-MONITOR-NOTIF-MIB Technical Reference Overview
The CISCO-IF-MONITOR-NOTIF-MIB SNMP MIB module published by Cisco defines 16 managed OID objects, including 7 scalar/column metrics, 1 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.9.10.999. Key tabular structures include cIfMonNotifTable. Monitored SNMP traps/notifications include cIfMonNotifEvent.
Key OID Definitions in CISCO-IF-MONITOR-NOTIF-MIB
.1.3.6.1.4.1.9.10.999Interface Monitor Notification MIB This MIB module defines the objects for sending notifications when certain errors over an interval have reached/exceeded a threshold, causing a severe condition.
.1.3.6.1.4.1.9.10.999.1.2This table contains information about the last notification that was sent for a particular interface.
.1.3.6.1.4.1.9.10.999.0.1The agent generates this notification when certain errors over an interval have reached/exceeded a threshold, causing a severe condition. The SNMP Notifications can be logged using the NOTIFICATION-LOG-MIB.
.1.3.6.1.4.1.9.10.999.1.1This object will be incremented and included in the varbind list of the cIfMonNotifEvent notification. This object is guaranteed to increase once per notification originated from the MIB. NMSes should track the value of this object received in each notification. If the difference in the value of this object across two consecutive notifications is more than one, a notification has been delayed, dropped, lost or routed out of sequence. The only reliable way to recover such notifications is via the NOTIFICATION-LOG-MIB. The NMS should preferably configure/create a log in the NOTIFICATION-LOG-MIB to capture cIfMonNotifEvent notifications. If possible, a named log should be created. When a notification loss is detected, the NMS can then poll the log to determine which notification was lost. The reader can look up RFC 3014 for more information on the NOTIFICATION-LOG-MIB. In addition to tracking the value of this object in each notification, the NMS should periodically poll this object. If the polled value of this object is two or more counts greater than the value from the last received notification, a notification has likely been dropped, and the NMS must use the NOTIFICATION-LOG-MIB to poll for the dropped notification.
.1.3.6.1.4.1.9.10.999.1.2.1Each entry contains information about the last notification sent for this interface.
.1.3.6.1.4.1.9.10.999.1.2.1.1This object specifies the value of sysUpTime at the last time a notification was sent for this interface.
.1.3.6.1.4.1.9.10.999.1.2.1.2The severity of the condition on the link when the notification is sent. A smaller enumerated integer value indicates that the exceeded condition is more severe. When a red severity notification is sent, it signifies that a severe event has occured, in which certain errors over an interval have reached/exceeded a high threshold . When a yellow severity notification is sent it signifies that an event has occured, in which certain errors over an interval have reached/exceeded a low threshold.
.1.3.6.1.4.1.9.10.999.1.2.1.3The link errors over an interval which caused the severe condition on the link. aborts number of packet aborted crc number of crc errors in packets received drops number of input packet dropped flaps number of link flaps frame-reject number of HDLC frames rejected runts number of frame runts dropped (X.25 Parameters) sabm number of SABMS commands received frmr number of Frame Rejects disc number of disconnect command received.
.1.3.6.1.4.1.9.10.999.1.2.1.4The value of the link errors over an interval that reached/exceeded the threshold, causing a severe condition.
.1.3.6.1.4.1.9.10.999.1.2.1.5The threshold which was reached/exceeded by the link errors over an interval, causing a severe condition.
.1.3.6.1.4.1.9.10.999.1.2.1.6The interval over which the link errors reached/exceeded the threshold, causing a severe condition.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.