CISCO-IETF-VDSL-LINE-MIB
The CISCO-IETF-VDSL-LINE-MIB enables monitoring and control of VDSL modem pairs by exposing physical layer performance metrics—including SNR margins, attenuation, and error counters (ES, LOS, LOF)—across physical, Fast, and Interleaved channel interfaces within the ifTable. It facilitates the management of VDSL line states and protocol parameters without requiring inter-agent communication, utilizing specific naming conventions (Vtur, Vtuc, Curr, Prev) to track transient and historical line statistics.
Imported Objects
Objects
87 total| Object Name |
|---|
ciscoIetfVdslMIB MODULE-IDENTITY .1.3.6.1.4.1.9.10.87 |
cvdslLineMib OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.87.1 |
cvdslNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.87.1.0 |
cvdslInitFailureNotification NOTIFICATION-TYPE .1.3.6.1.4.1.9.10.87.1.0.1 |
cvdslMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.87.1.1 |
cvdslLineTable SEQUENCE OF CvdslLineEntry .1.3.6.1.4.1.9.10.87.1.1.1 |
cvdslLineEntry CvdslLineEntry .1.3.6.1.4.1.9.10.87.1.1.1.1 |
cvdslLineCodingro CVdslLineCodingType .1.3.6.1.4.1.9.10.87.1.1.1.1.1 |
cvdslLineTypero Enumeration .1.3.6.1.4.1.9.10.87.1.1.1.1.2 |
cvdslLineConfProfilerw Integer32 .1.3.6.1.4.1.9.10.87.1.1.1.1.3 |
cvdslLineAlarmConfProfilerw Integer32 .1.3.6.1.4.1.9.10.87.1.1.1.1.4 |
cvdslPhysTable SEQUENCE OF CvdslPhysEntry .1.3.6.1.4.1.9.10.87.1.1.2 |
cvdslPhysEntry CvdslPhysEntry .1.3.6.1.4.1.9.10.87.1.1.2.1 |
cvdslPhysSide CVdslLineEntity .1.3.6.1.4.1.9.10.87.1.1.2.1.1 |
cvdslInvSerialNumberro SnmpAdminString .1.3.6.1.4.1.9.10.87.1.1.2.1.2 |
cvdslInvVendorIDro SnmpAdminString .1.3.6.1.4.1.9.10.87.1.1.2.1.3 |
cvdslInvVersionNumberro SnmpAdminString .1.3.6.1.4.1.9.10.87.1.1.2.1.4 |
cvdslCurrSnrMgnro INTEGER(-640..640) UNITS "tenth dB" .1.3.6.1.4.1.9.10.87.1.1.2.1.5 |
cvdslCurrAtnro Gauge32 .1.3.6.1.4.1.9.10.87.1.1.2.1.6 |
cvdslCurrStatusro Bits .1.3.6.1.4.1.9.10.87.1.1.2.1.7 |
cvdslCurrOutputPwrro INTEGER (-310..310) UNITS "tenth dBm" .1.3.6.1.4.1.9.10.87.1.1.2.1.8 |
cvdslCurrAttainableRatero Gauge32 UNITS "bps" .1.3.6.1.4.1.9.10.87.1.1.2.1.9 |
cvdslChanTable SEQUENCE OF CvdslChanEntry .1.3.6.1.4.1.9.10.87.1.1.3 |
cvdslChanEntry CvdslChanEntry .1.3.6.1.4.1.9.10.87.1.1.3.1 |
cvdslChanInterleaveDelayro Gauge32 UNITS "milli-seconds" .1.3.6.1.4.1.9.10.87.1.1.3.1.1 |
cvdslChanCrcBlockLengthro Gauge32 UNITS "byte" .1.3.6.1.4.1.9.10.87.1.1.3.1.2 |
cvdslLineConfProfileTable SEQUENCE OF CvdslLineConfProfileEntry .1.3.6.1.4.1.9.10.87.1.1.8 |
cvdslLineConfProfileEntry CvdslLineConfProfileEntry .1.3.6.1.4.1.9.10.87.1.1.8.1 |
cvdslLineConfProfileIndex Integer32 .1.3.6.1.4.1.9.10.87.1.1.8.1.1 |
cvdslLineConfProfileNamerw SnmpAdminString .1.3.6.1.4.1.9.10.87.1.1.8.1.2 |
cvdslLineConfTargetSnrMgnrw INTEGER .1.3.6.1.4.1.9.10.87.1.1.8.1.3 |
cvdslLineConfTxSpeedrw INTEGER .1.3.6.1.4.1.9.10.87.1.1.8.1.4 |
cvdslLineConfRxSpeedrw INTEGER .1.3.6.1.4.1.9.10.87.1.1.8.1.5 |
cvdslLineConfProfileRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.10.87.1.1.8.1.6 |
cvdslLineMCMConfProfileTable SEQUENCE OF CvdslLineMCMConfProfileEntry .1.3.6.1.4.1.9.10.87.1.1.9 |
cvdslLineMCMConfProfileEntry CvdslLineMCMConfProfileEntry .1.3.6.1.4.1.9.10.87.1.1.9.1 |
cvdslMCMConfProfileTxWindowLengthrw INTEGER .1.3.6.1.4.1.9.10.87.1.1.9.1.1 |
cvdslMCMConfProfileRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.10.87.1.1.9.1.2 |
cvdslLineMCMConfProfileTxBandTable SEQUENCE OF CvdslLineMCMConfProfileTxBandEntry .1.3.6.1.4.1.9.10.87.1.1.10 |
cvdslLineMCMConfProfileTxBandEntry CvdslLineMCMConfProfileTxBandEntry .1.3.6.1.4.1.9.10.87.1.1.10.1 |
cvdslMCMConfProfileTxBandNumber INTEGER .1.3.6.1.4.1.9.10.87.1.1.10.1.1 |
cvdslMCMConfProfileTxBandStartrw INTEGER .1.3.6.1.4.1.9.10.87.1.1.10.1.2 |
cvdslMCMConfProfileTxBandStoprw INTEGER .1.3.6.1.4.1.9.10.87.1.1.10.1.3 |
cvdslMCMConfProfileTxBandRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.10.87.1.1.10.1.4 |
cvdslLineMCMConfProfileRxBandTable SEQUENCE OF CvdslLineMCMConfProfileRxBandEntry .1.3.6.1.4.1.9.10.87.1.1.11 |
cvdslLineMCMConfProfileRxBandEntry CvdslLineMCMConfProfileRxBandEntry .1.3.6.1.4.1.9.10.87.1.1.11.1 |
cvdslMCMConfProfileRxBandNumber INTEGER .1.3.6.1.4.1.9.10.87.1.1.11.1.1 |
cvdslMCMConfProfileRxBandStartrw INTEGER .1.3.6.1.4.1.9.10.87.1.1.11.1.2 |
cvdslMCMConfProfileRxBandStoprw INTEGER .1.3.6.1.4.1.9.10.87.1.1.11.1.3 |
cvdslMCMConfProfileRxBandRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.10.87.1.1.11.1.4 |
cvdslLineMCMConfProfileTxPSDTable SEQUENCE OF CvdslLineMCMConfProfileTxPSDEntry .1.3.6.1.4.1.9.10.87.1.1.12 |
cvdslLineMCMConfProfileTxPSDEntry CvdslLineMCMConfProfileTxPSDEntry .1.3.6.1.4.1.9.10.87.1.1.12.1 |
cvdslMCMConfProfileTxPSDNumber INTEGER .1.3.6.1.4.1.9.10.87.1.1.12.1.1 |
cvdslMCMConfProfileTxPSDTonerw INTEGER .1.3.6.1.4.1.9.10.87.1.1.12.1.2 |
cvdslMCMConfProfileTxPSDPSDrw INTEGER .1.3.6.1.4.1.9.10.87.1.1.12.1.3 |
cvdslMCMConfProfileTxPSDRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.10.87.1.1.12.1.4 |
cvdslLineMCMConfProfileMaxTxPSDTable SEQUENCE OF CvdslLineMCMConfProfileMaxTxPSDEntry .1.3.6.1.4.1.9.10.87.1.1.13 |
cvdslLineMCMConfProfileMaxTxPSDEntry CvdslLineMCMConfProfileMaxTxPSDEntry .1.3.6.1.4.1.9.10.87.1.1.13.1 |
cvdslMCMConfProfileMaxTxPSDNumber INTEGER .1.3.6.1.4.1.9.10.87.1.1.13.1.1 |
cvdslMCMConfProfileMaxTxPSDTonerw INTEGER .1.3.6.1.4.1.9.10.87.1.1.13.1.2 |
cvdslMCMConfProfileMaxTxPSDPSDrw INTEGER .1.3.6.1.4.1.9.10.87.1.1.13.1.3 |
cvdslMCMConfProfileMaxTxPSDRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.10.87.1.1.13.1.4 |
cvdslLineMCMConfProfileMaxRxPSDTable SEQUENCE OF CvdslLineMCMConfProfileMaxRxPSDEntry .1.3.6.1.4.1.9.10.87.1.1.14 |
cvdslLineMCMConfProfileMaxRxPSDEntry CvdslLineMCMConfProfileMaxRxPSDEntry .1.3.6.1.4.1.9.10.87.1.1.14.1 |
cvdslMCMConfProfileMaxRxPSDNumber INTEGER .1.3.6.1.4.1.9.10.87.1.1.14.1.1 |
cvdslMCMConfProfileMaxRxPSDTonerw INTEGER .1.3.6.1.4.1.9.10.87.1.1.14.1.2 |
cvdslMCMConfProfileMaxRxPSDPSDrw INTEGER .1.3.6.1.4.1.9.10.87.1.1.14.1.3 |
cvdslMCMConfProfileMaxRxPSDRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.10.87.1.1.14.1.4 |
cvdslLineSCMConfProfileTable SEQUENCE OF CvdslLineSCMConfProfileEntry .1.3.6.1.4.1.9.10.87.1.1.15 |
cvdslLineSCMConfProfileEntry CvdslLineSCMConfProfileEntry .1.3.6.1.4.1.9.10.87.1.1.15.1 |
cvdslSCMConfProfileInterleaveDepthrw INTEGER .1.3.6.1.4.1.9.10.87.1.1.15.1.1 |
cvdslSCMConfProfileFastCodewordSizerw INTEGER .1.3.6.1.4.1.9.10.87.1.1.15.1.2 |
cvdslSCMConfProfileTransmitPSDMaskrw Bits .1.3.6.1.4.1.9.10.87.1.1.15.1.3 |
cvdslSCMConfProfileTransmitPSDLevelrw INTEGER .1.3.6.1.4.1.9.10.87.1.1.15.1.4 |
cvdslSCMConfProfileSymbolRateProfilerw INTEGER .1.3.6.1.4.1.9.10.87.1.1.15.1.5 |
cvdslSCMConfProfileConstellationSizerw INTEGER .1.3.6.1.4.1.9.10.87.1.1.15.1.6 |
cvdslSCMConfProfileCenterFrequencyrw INTEGER .1.3.6.1.4.1.9.10.87.1.1.15.1.7 |
cvdslSCMConfProfileRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.10.87.1.1.15.1.8 |
cvdslLineAlarmConfProfileTable SEQUENCE OF CvdslLineAlarmConfProfileEntry .1.3.6.1.4.1.9.10.87.1.1.16 |
cvdslLineAlarmConfProfileEntry CvdslLineAlarmConfProfileEntry .1.3.6.1.4.1.9.10.87.1.1.16.1 |
cvdslLineAlarmConfProfileIndex Integer32 .1.3.6.1.4.1.9.10.87.1.1.16.1.1 |
cvdslLineAlarmConfProfileNamerw SnmpAdminString .1.3.6.1.4.1.9.10.87.1.1.16.1.2 |
cvdslInitFailureNotificationEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.10.87.1.1.16.1.3 |
cvdslLineAlarmConfProfileRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.10.87.1.1.16.1.4 |
cvdslConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.87.1.3 |
cvdslGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.87.1.3.1 |
cvdslCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.87.1.3.2 |
CISCO-IETF-VDSL-LINE-MIB Technical Reference Overview
The CISCO-IETF-VDSL-LINE-MIB SNMP MIB module published by Cisco defines 87 managed OID objects, including 55 scalar/column metrics, 12 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.9.10.87. Key tabular structures include cvdslLineTable, cvdslPhysTable, cvdslChanTable, cvdslLineConfProfileTable, cvdslLineMCMConfProfileTable, cvdslLineMCMConfProfileTxBandTable. Monitored SNMP traps/notifications include cvdslInitFailureNotification.
Key OID Definitions in CISCO-IETF-VDSL-LINE-MIB
.1.3.6.1.4.1.9.10.87The MIB module defining objects for the management of a pair of VDSL modems at each end of the VDSL line. Each VDSL line has an entry in an ifTable. An agent may reside at either end of the VDSL line however the MIB is designed to require no management communication between them beyond that inherent in the low-level VDSL line protocol. The agent may monitor and control this protocol for its needs. VDSL lines may support optional Fast or Interleaved channels. If these are supported, additional entries corresponding to the supported channels must be created in the ifTable. Thus a VDSL line that supports both channels will have three entries in the ifTable, one for each physical, fast, and interleaved, whose ifType values are equal to vdsl(97), fast(125), and interleaved(124), respectively. The ifStackTable is used to represent the relationship between the entries. Naming Conventions: Vtuc Vtur Vtu Curr Prev Atn ES LCS Lof Lol Los Lpr xyzs (e.g., xyz=Lof, Los, Lpr) Max Mgn Min Psd Snr Tx Blks
.1.3.6.1.4.1.9.10.87.1.1.1This table includes common attributes describing both ends of the line. It is required for all VDSL physical interfaces. VDSL physical interfaces are those ifEntries where ifType is equal to vdsl(97).
.1.3.6.1.4.1.9.10.87.1.1.2This table provides one row for each Vtu. Each row contains the Physical Layer Parameters table for that Vtu. VDSL physical interfaces are those ifEntries where ifType is equal to vdsl(97).
.1.3.6.1.4.1.9.10.87.1.1.3This table provides one row for each Vtu channel. VDSL channel interfaces are those ifEntries where ifType is equal to interleave(124) or fast(125).
.1.3.6.1.4.1.9.10.87.1.1.8This table contains information on the VDSL line configuration. One entry in this table reflects a profile defined by a manager which can be used to configure the VDSL line.
.1.3.6.1.4.1.9.10.87.1.1.9This table contains information on the VDSL line configuration. One entry in this table reflects a profile defined by a manager which can be used to configure the VDSL line.
.1.3.6.1.4.1.9.10.87.1.1.10This table contains transmit band descriptor configuration information for a VDSL line. Each entry in this table reflects the configuration for one of possibly many bands with a multiple carrier modulation (MCM) VDSL line. These entries are defined by a manager and can be used to configure the VDSL line.
.1.3.6.1.4.1.9.10.87.1.1.11This table contains receive band descriptor configuration information for a VDSL line. Each entry in this table reflects the configuration for one of possibly many bands with a multiple carrier modulation (MCM) VDSL line. These entries are defined by a manager and can be used to configure the VDSL line.
.1.3.6.1.4.1.9.10.87.1.1.12This table contains transmit PSD mask descriptor configuration information for a VDSL line. Each entry in this table reflects the configuration for one tone within a multiple carrier modulation (MCM) VDSL line. These entries are defined by a manager and can be used to configure the VDSL line.
.1.3.6.1.4.1.9.10.87.1.1.13This table contains transmit maximum PSD mask descriptor configuration information for a VDSL line. Each entry in this table reflects the configuration for one tone within a multiple carrier modulation (MCM) VDSL modem. These entries are defined by a manager and can be used to configure the VDSL line.
.1.3.6.1.4.1.9.10.87.1.1.14This table contains maximum receive PSD mask descriptor configuration information for a VDSL line. Each entry in this table reflects the configuration for one tone within a multiple carrier modulation (MCM) VDSL modem. These entries are defined by a manager and can be used to configure the VDSL line.
.1.3.6.1.4.1.9.10.87.1.1.15This table contains information on the VDSL line configuration. One entry in this table reflects a profile defined by a manager which can be used to configure the VDSL line.
.1.3.6.1.4.1.9.10.87.1.1.16This table contains information on the VDSL line alarm configuration. One entry in this table reflects a profile defined by a manager which can be used to configure the VDSL line alarm thresholds.
.1.3.6.1.4.1.9.10.87.1.0.1Vtu initialization failed. See cvdslCurrStatus for potential reasons.
.1.3.6.1.4.1.9.10.87.1.1.1.1An entry in the cvdslLineTable.
.1.3.6.1.4.1.9.10.87.1.1.1.1.1Specifies the VDSL coding type used on this line.
.1.3.6.1.4.1.9.10.87.1.1.1.1.2Defines the type of VDSL physical line entity that exists, by defining whether and how the line is channelized. If the line is channelized, the value will be other than noChannel(1). This object defines which channel type(s) are supported. In the case that the line is channelized, the manager can use the ifStackTable to determine the ifIndex for the associated channel(s).
.1.3.6.1.4.1.9.10.87.1.1.1.1.3The value of this object identifies the rows in the VDSL Line Configuration Profile Table, ( cvdslLineConfProfileTable ), which apply for this VDSL line, and channels if applicable.
.1.3.6.1.4.1.9.10.87.1.1.1.1.4The value of this object identifies the rows in the VDSL Line Alarm Configuration Profile Table, ( cvdslLineAlarmConfProfileTable ), which apply to this VDSL line, and channels if applicable.
.1.3.6.1.4.1.9.10.87.1.1.2.1An entry in the cvdslPhysTable.
.1.3.6.1.4.1.9.10.87.1.1.2.1.1Identifies whether the modem is the Vtuc or Vtur.
.1.3.6.1.4.1.9.10.87.1.1.2.1.2The vendor specific string that identifies the vendor equipment.
.1.3.6.1.4.1.9.10.87.1.1.2.1.3The vendor ID code is a copy of the binary vendor identification field defined by the PHY[10] and expressed as readable characters.
.1.3.6.1.4.1.9.10.87.1.1.2.1.4The vendor specific version number sent by this Vtu as part of the initialization messages. It is a copy of the binary version number field defined by the PHY[10] and expressed as readable characters.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.