CISCO-FLASH-MIB
The CISCO-FLASH-MIB enables SNMP-based monitoring and management of non-volatile Flash memory devices on Cisco network hardware, exposing metrics for total capacity, available space, and file system status to facilitate storage utilization tracking and alerting.
Imported Objects
Objects
117 total| Object Name |
|---|
ciscoFlashMIB OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.10 |
RFC1155-SMI Unknown .1.3.6.1.4.1.9.9.10 |
ciscoFlashMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.10.1 |
ciscoFlashDevice OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.10.1.1 |
ciscoFlashDevicesSupportedro INTEGER .1.3.6.1.4.1.9.9.10.1.1.1 |
ciscoFlashDeviceTable SEQUENCE OF CiscoFlashDeviceEntry .1.3.6.1.4.1.9.9.10.1.1.2 |
ciscoFlashDeviceEntry CiscoFlashDeviceEntry .1.3.6.1.4.1.9.9.10.1.1.2.1 |
ciscoFlashDeviceIndex INTEGER .1.3.6.1.4.1.9.9.10.1.1.2.1.1 |
ciscoFlashDeviceSizero INTEGER -- Units -- bytes .1.3.6.1.4.1.9.9.10.1.1.2.1.2 |
ciscoFlashDeviceMinPartitionSizero INTEGER -- Units -- bytes .1.3.6.1.4.1.9.9.10.1.1.2.1.3 |
ciscoFlashDeviceMaxPartitionsro INTEGER .1.3.6.1.4.1.9.9.10.1.1.2.1.4 |
ciscoFlashDevicePartitionsro INTEGER .1.3.6.1.4.1.9.9.10.1.1.2.1.5 |
ciscoFlashDeviceChipCountro INTEGER .1.3.6.1.4.1.9.9.10.1.1.2.1.6 |
ciscoFlashDeviceNamero DisplayString .1.3.6.1.4.1.9.9.10.1.1.2.1.7 |
ciscoFlashDeviceDescrro DisplayString .1.3.6.1.4.1.9.9.10.1.1.2.1.8 |
ciscoFlashDeviceControllerro DisplayString .1.3.6.1.4.1.9.9.10.1.1.2.1.9 |
ciscoFlashDeviceCardro InstancePointer -- Rsyntax OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.10.1.1.2.1.10 |
ciscoFlashDeviceProgrammingJumperro Enumeration .1.3.6.1.4.1.9.9.10.1.1.2.1.11 |
ciscoFlashDeviceInitTimero TimeStamp -- Rsyntax TimeTicks .1.3.6.1.4.1.9.9.10.1.1.2.1.12 |
ciscoFlashDeviceRemovablero TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } .1.3.6.1.4.1.9.9.10.1.1.2.1.13 |
ciscoFlashChips OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.10.1.1.3 |
ciscoFlashChipTable SEQUENCE OF CiscoFlashChipEntry .1.3.6.1.4.1.9.9.10.1.1.3.1 |
ciscoFlashChipEntry CiscoFlashChipEntry .1.3.6.1.4.1.9.9.10.1.1.3.1.1 |
ciscoFlashChipIndex INTEGER .1.3.6.1.4.1.9.9.10.1.1.3.1.1.1 |
ciscoFlashChipCodero DisplayString .1.3.6.1.4.1.9.9.10.1.1.3.1.1.2 |
ciscoFlashChipDescrro DisplayString .1.3.6.1.4.1.9.9.10.1.1.3.1.1.3 |
ciscoFlashChipWriteRetriesro Counter .1.3.6.1.4.1.9.9.10.1.1.3.1.1.4 |
ciscoFlashChipEraseRetriesro Counter .1.3.6.1.4.1.9.9.10.1.1.3.1.1.5 |
ciscoFlashChipMaxWriteRetriesro INTEGER .1.3.6.1.4.1.9.9.10.1.1.3.1.1.6 |
ciscoFlashChipMaxEraseRetriesro INTEGER .1.3.6.1.4.1.9.9.10.1.1.3.1.1.7 |
ciscoFlashPartitions OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.10.1.1.4 |
ciscoFlashPartitionTable SEQUENCE OF CiscoFlashPartitionEntry .1.3.6.1.4.1.9.9.10.1.1.4.1 |
ciscoFlashPartitionEntry CiscoFlashPartitionEntry .1.3.6.1.4.1.9.9.10.1.1.4.1.1 |
ciscoFlashPartitionIndex INTEGER .1.3.6.1.4.1.9.9.10.1.1.4.1.1.1 |
ciscoFlashPartitionStartChipro INTEGER .1.3.6.1.4.1.9.9.10.1.1.4.1.1.2 |
ciscoFlashPartitionEndChipro INTEGER .1.3.6.1.4.1.9.9.10.1.1.4.1.1.3 |
ciscoFlashPartitionSizero INTEGER -- Units -- bytes .1.3.6.1.4.1.9.9.10.1.1.4.1.1.4 |
ciscoFlashPartitionFreeSpacero Gauge -- Units -- bytes .1.3.6.1.4.1.9.9.10.1.1.4.1.1.5 |
ciscoFlashPartitionFileCountro INTEGER .1.3.6.1.4.1.9.9.10.1.1.4.1.1.6 |
ciscoFlashPartitionChecksumAlgorithmro Enumeration .1.3.6.1.4.1.9.9.10.1.1.4.1.1.7 |
ciscoFlashPartitionStatusro Enumeration .1.3.6.1.4.1.9.9.10.1.1.4.1.1.8 |
ciscoFlashPartitionUpgradeMethodro Enumeration .1.3.6.1.4.1.9.9.10.1.1.4.1.1.9 |
ciscoFlashPartitionNamero DisplayString .1.3.6.1.4.1.9.9.10.1.1.4.1.1.10 |
ciscoFlashPartitionNeedErasurero TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } .1.3.6.1.4.1.9.9.10.1.1.4.1.1.11 |
ciscoFlashPartitionFileNameLengthro INTEGER .1.3.6.1.4.1.9.9.10.1.1.4.1.1.12 |
ciscoFlashFiles OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.10.1.1.4.2 |
ciscoFlashFileTable SEQUENCE OF CiscoFlashFileEntry .1.3.6.1.4.1.9.9.10.1.1.4.2.1 |
ciscoFlashFileEntry CiscoFlashFileEntry .1.3.6.1.4.1.9.9.10.1.1.4.2.1.1 |
ciscoFlashFileIndex INTEGER .1.3.6.1.4.1.9.9.10.1.1.4.2.1.1.1 |
ciscoFlashFileSizero INTEGER .1.3.6.1.4.1.9.9.10.1.1.4.2.1.1.2 |
ciscoFlashFileChecksumro ChecksumString -- Rsyntax OCTET STRING .1.3.6.1.4.1.9.9.10.1.1.4.2.1.1.3 |
ciscoFlashFileStatusro Enumeration .1.3.6.1.4.1.9.9.10.1.1.4.2.1.1.4 |
ciscoFlashFileNamero DisplayString .1.3.6.1.4.1.9.9.10.1.1.4.2.1.1.5 |
ciscoFlashFileTypero FlashFileType -- Rsyntax INTEGER { -- unknown(1), -- config(2), -- image(3), -- directory(4), -- crashinfo(5) -- } .1.3.6.1.4.1.9.9.10.1.1.4.2.1.1.6 |
ciscoFlashOps OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.10.1.2 |
ciscoFlashCopyTable SEQUENCE OF CiscoFlashCopyEntry .1.3.6.1.4.1.9.9.10.1.2.1 |
ciscoFlashCopyEntry CiscoFlashCopyEntry .1.3.6.1.4.1.9.9.10.1.2.1.1 |
ciscoFlashCopySerialNumber INTEGER .1.3.6.1.4.1.9.9.10.1.2.1.1.1 |
ciscoFlashCopyCommandrw Enumeration .1.3.6.1.4.1.9.9.10.1.2.1.1.2 |
ciscoFlashCopyProtocolrw Enumeration .1.3.6.1.4.1.9.9.10.1.2.1.1.3 |
ciscoFlashCopyServerAddressrw IpAddress .1.3.6.1.4.1.9.9.10.1.2.1.1.4 |
ciscoFlashCopySourceNamerw DisplayString .1.3.6.1.4.1.9.9.10.1.2.1.1.5 |
ciscoFlashCopyDestinationNamerw DisplayString .1.3.6.1.4.1.9.9.10.1.2.1.1.6 |
ciscoFlashCopyRemoteUserNamerw DisplayString .1.3.6.1.4.1.9.9.10.1.2.1.1.7 |
ciscoFlashCopyStatusro Enumeration .1.3.6.1.4.1.9.9.10.1.2.1.1.8 |
ciscoFlashCopyNotifyOnCompletionrw TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } .1.3.6.1.4.1.9.9.10.1.2.1.1.9 |
ciscoFlashCopyTimero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.9.9.10.1.2.1.1.10 |
ciscoFlashCopyEntryStatusrw RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } .1.3.6.1.4.1.9.9.10.1.2.1.1.11 |
ciscoFlashPartitioningTable SEQUENCE OF CiscoFlashPartitioningEntry .1.3.6.1.4.1.9.9.10.1.2.2 |
ciscoFlashPartitioningEntry CiscoFlashPartitioningEntry .1.3.6.1.4.1.9.9.10.1.2.2.1 |
ciscoFlashPartitioningSerialNumber INTEGER .1.3.6.1.4.1.9.9.10.1.2.2.1.1 |
ciscoFlashPartitioningCommandrw Enumeration .1.3.6.1.4.1.9.9.10.1.2.2.1.2 |
ciscoFlashPartitioningDestinationNamerw DisplayString .1.3.6.1.4.1.9.9.10.1.2.2.1.3 |
ciscoFlashPartitioningPartitionCountrw INTEGER .1.3.6.1.4.1.9.9.10.1.2.2.1.4 |
ciscoFlashPartitioningPartitionSizesrw DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.9.9.10.1.2.2.1.5 |
ciscoFlashPartitioningStatusro Enumeration .1.3.6.1.4.1.9.9.10.1.2.2.1.6 |
ciscoFlashPartitioningNotifyOnCompletionrw TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } .1.3.6.1.4.1.9.9.10.1.2.2.1.7 |
ciscoFlashPartitioningTimero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.9.9.10.1.2.2.1.8 |
ciscoFlashPartitioningEntryStatusrw RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } .1.3.6.1.4.1.9.9.10.1.2.2.1.9 |
ciscoFlashMiscOpTable SEQUENCE OF CiscoFlashMiscOpEntry .1.3.6.1.4.1.9.9.10.1.2.3 |
ciscoFlashMiscOpEntry CiscoFlashMiscOpEntry .1.3.6.1.4.1.9.9.10.1.2.3.1 |
ciscoFlashMiscOpSerialNumber INTEGER .1.3.6.1.4.1.9.9.10.1.2.3.1.1 |
ciscoFlashMiscOpCommandrw Enumeration .1.3.6.1.4.1.9.9.10.1.2.3.1.2 |
ciscoFlashMiscOpDestinationNamerw DisplayString .1.3.6.1.4.1.9.9.10.1.2.3.1.3 |
ciscoFlashMiscOpStatusro Enumeration .1.3.6.1.4.1.9.9.10.1.2.3.1.4 |
ciscoFlashMiscOpNotifyOnCompletionrw TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } .1.3.6.1.4.1.9.9.10.1.2.3.1.5 |
ciscoFlashMiscOpTimero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.9.9.10.1.2.3.1.6 |
ciscoFlashMiscOpEntryStatusrw RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } .1.3.6.1.4.1.9.9.10.1.2.3.1.7 |
ciscoFlashMIBTrapPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.10.1.3 |
ciscoFlashMIBTraps OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.10.1.3.0 |
ciscoFlashCopyCompletionTrap TRAP-TYPE .1.3.6.1.4.1.9.9.10.1.3.0.1 |
ciscoFlashPartitioningCompletionTrap TRAP-TYPE .1.3.6.1.4.1.9.9.10.1.3.0.2 |
ciscoFlashMiscOpCompletionTrap TRAP-TYPE .1.3.6.1.4.1.9.9.10.1.3.0.3 |
ciscoFlashDeviceChangeTrap TRAP-TYPE .1.3.6.1.4.1.9.9.10.1.3.0.4 |
ciscoFlashDeviceInsertedNotif TRAP-TYPE .1.3.6.1.4.1.9.9.10.1.3.0.5 |
ciscoFlashDeviceRemovedNotif TRAP-TYPE .1.3.6.1.4.1.9.9.10.1.3.0.6 |
ciscoFlashCfg OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.10.1.4 |
ciscoFlashCfgDevInsNotifEnablerw TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } .1.3.6.1.4.1.9.9.10.1.4.1 |
ciscoFlashCfgDevRemNotifEnablerw TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } .1.3.6.1.4.1.9.9.10.1.4.2 |
ciscoFlashMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.10.2 |
CISCO-FLASH-MIB Technical Reference Overview
The CISCO-FLASH-MIB SNMP MIB module published by Cisco defines 117 managed OID objects, including 69 scalar/column metrics, 7 SNMP tables, and 6 trap/notification events. Key tabular structures include ciscoFlashDeviceTable, ciscoFlashChipTable, ciscoFlashPartitionTable, ciscoFlashFileTable, ciscoFlashCopyTable, ciscoFlashPartitioningTable. Monitored SNMP traps/notifications include ciscoFlashCopyCompletionTrap, ciscoFlashPartitioningCompletionTrap, ciscoFlashMiscOpCompletionTrap, ciscoFlashDeviceChangeTrap, ciscoFlashDeviceInsertedNotif, ciscoFlashDeviceRemovedNotif.
Key OID Definitions in CISCO-FLASH-MIB
.1.3.6.1.4.1.9.9.10.1.1.2Table of Flash device properties for each initialized Flash device. Each Flash device installed in a system is detected, sized, and initialized when the system image boots up. For removable Flash devices, the device properties will be dynamically deleted and recreated as the device is removed and inserted. Note that in this case, the newly inserted device may not be the same as the earlier removed one. The ciscoFlashDeviceInitTime object is available for a management station to determine the time at which a device was initialized, and thereby detect the change of a removable device. A removable device that has not been installed will also have an entry in this table. This is to let a management station know about a removable device that has been removed. Since a removed device obviously cannot be sized and initialized, the table entry for such a device will have ciscoFlashDeviceSize equal to zero, and the following objects will have an indeterminate value: ciscoFlashDeviceMinPartitionSize, ciscoFlashDeviceMaxPartitions, ciscoFlashDevicePartitions, and ciscoFlashDeviceChipCount. ciscoFlashDeviceRemovable will be true to indicate it is removable.
.1.3.6.1.4.1.9.9.10.1.1.3.1Table of Flash device chip properties for each initialized Flash device. This table is meant primarily for aiding error diagnosis.
.1.3.6.1.4.1.9.9.10.1.1.4.1Table of flash device partition properties for each initialized flash partition. Whenever there is no explicit partitioning done, a single partition spanning the entire device will be assumed to exist. There will therefore always be atleast one partition on a device.
.1.3.6.1.4.1.9.9.10.1.1.4.2.1Table of information for files in a Flash partition.
.1.3.6.1.4.1.9.9.10.1.2.1A table of Flash copy operation entries. Each entry represents a Flash copy operation (to or from Flash) that has been initiated.
.1.3.6.1.4.1.9.9.10.1.2.2A table of Flash partitioning operation entries. Each entry represents a Flash partitioning operation that has been initiated.
.1.3.6.1.4.1.9.9.10.1.2.3A table of misc Flash operation entries. Each entry represents a Flash operation that has been initiated.
.1.3.6.1.4.1.9.9.10.1.3.0.1A ciscoFlashCopyCompletionTrap is sent at the completion of a flash copy operation if such a trap was requested when the operation was initiated.
.1.3.6.1.4.1.9.9.10.1.3.0.2A ciscoFlashPartitioningCompletionTrap is sent at the completion of a partitioning operation if such a trap was requested when the operation was initiated.
.1.3.6.1.4.1.9.9.10.1.3.0.3A ciscoFlashMiscOpCompletionTrap is sent at the completion of a miscellaneous flash operation (enumerated in ciscoFlashMiscOpCommand) if such a trap was requested when the operation was initiated.
.1.3.6.1.4.1.9.9.10.1.3.0.4A ciscoFlashDeviceChangeTrap is sent whenever a removable Flash device is inserted or removed.
.1.3.6.1.4.1.9.9.10.1.3.0.5A ciscoFlashDeviceInsertedNotif notification is sent whenever a removable Flash device is inserted.
.1.3.6.1.4.1.9.9.10.1.3.0.6A ciscoFlashDeviceRemovedNotif notification is sent whenever a removable Flash device is removed.
.1.3.6.1.4.1.9.9.10.1.1.1Number of Flash devices supported by the system. If the system does not support any Flash devices, this MIB will not be loaded on that system. The value of this object will therefore be atleast 1.
.1.3.6.1.4.1.9.9.10.1.4.1Specifies whether or not a notification should be generated on the insertion of a Flash device. If the value of this object is 'true' then the ciscoFlashDeviceInsertedNotif notification will be generated. If the value of this object is 'false' then the ciscoFlashDeviceInsertedNotif notification will not be generated. It is the responsibility of the management entity to ensure that the SNMP administrative model is configured in such a way as to allow the notification to be delivered.
.1.3.6.1.4.1.9.9.10.1.4.2Specifies whether or not a notification should be generated on the removal of a Flash device. If the value of this object is 'true' then the ciscoFlashDeviceRemovedNotif notification will be generated. If the value of this object is 'false' then the ciscoFlashDeviceRemovedNotif notification will not be generated. It is the responsibility of the management entity to ensure that the SNMP administrative model is configured in such a way as to allow the notification to be delivered.
.1.3.6.1.4.1.9.9.10.1.1.2.1An entry in the table of flash device properties for each initialized flash device. Each entry can be randomly accessed by using ciscoFlashDeviceIndex as an index into the table. Note that removable devices will have an entry in the table even when they have been removed. However, a non-removable device that has not been installed will not have an entry in the table.
.1.3.6.1.4.1.9.9.10.1.1.2.1.1Flash device sequence number to index within the table of initialized flash devices. The lowest value should be 1. The highest should be less than or equal to the value of the ciscoFlashDevicesSupported object.
.1.3.6.1.4.1.9.9.10.1.1.2.1.2Total size of the Flash device. For a removable device, the size will be zero if the device has been removed.
.1.3.6.1.4.1.9.9.10.1.1.2.1.3This object will give the minimum partition size supported for this device. For systems that execute code directly out of Flash, the minimum partition size needs to be the bank size. (Bank size is equal to the size of a chip multiplied by the width of the device. In most cases, the device width is 4 bytes, and so the bank size would be four times the size of a chip). This has to be so because all programming commands affect the operation of an entire chip (in our case, an entire bank because all operations are done on the entire width of the device) even though the actual command may be localized to a small portion of each chip. So when executing code out of Flash, one needs to be able to write and erase some portion of Flash without affecting the code execution. For systems that execute code out of DRAM or ROM, it is possible to partition Flash with a finer granularity (for eg., at erase sector boundaries) if the system code supports such granularity. This object will let a management entity know the minimum partition size as defined by the system. If the system does not support partitioning, the value will be equal to the device size in ciscoFlashDeviceSize. The maximum number of partitions that could be configured will be equal to the minimum of ciscoFlashDeviceMaxPartitions and (ciscoFlashDeviceSize / ciscoFlashDeviceMinPartitionSize).
.1.3.6.1.4.1.9.9.10.1.1.2.1.4Max number of partitions supported by the system for this Flash device. Default will be 1, which actually means that partitioning is not supported. Note that this value will be defined by system limitations, not by the flash device itself (for eg., the system may impose a limit of 2 partitions even though the device may be large enough to be partitioned into 4 based on the smallest partition unit supported). On systems that execute code out of Flash, partitioning is a way of creating multiple file systems in the Flash device so that writing into or erasing of one file system can be done while executing code residing in another file system. For systems executing code out of DRAM, partitioning gives a way of sub-dividing a large Flash device for easier management of files.
.1.3.6.1.4.1.9.9.10.1.1.2.1.5Flash device partitions actually present. Number of partitions cannot exceed the minimum of ciscoFlashDeviceMaxPartitions and (ciscoFlashDeviceSize / ciscoFlashDeviceMinPartitionSize). Will be equal to at least 1, the case where the partition spans the entire device (actually no partitioning). A partition will contain one or more minimum partition units (where a minimum partition unit is defined by ciscoFlashDeviceMinPartitionSize).
.1.3.6.1.4.1.9.9.10.1.1.2.1.6Total number of chips within the Flash device. The purpose of this object is to provide information upfront to a management station on how much chip info to expect and possibly help double check the chip index against an upper limit when randomly retrieving chip info for a partition.
.1.3.6.1.4.1.9.9.10.1.1.2.1.7Flash device name. This name is used to refer to the device within the system. Flash operations get directed to a device based on this name. The system has a concept of a default device. This would be the primary or most used device in case of multiple devices. The system directs an operation to the default device whenever a device name is not specified. The device name is therefore mandatory except when the operation is being done on the default device, or, the system supports only a single Flash device. The device name will always be available for a removable device, even when the device has been removed.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.