Home/Catalog/CISCO-FLASH-MIB

CISCO-FLASH-MIB

AI MIB Summary

The CISCO-FLASH-MIB enables SNMP-based monitoring and management of non-volatile Flash memory devices on Cisco network hardware, exposing metrics for total capacity, available space, and file system status to facilitate storage utilization tracking and alerting.

This MIB provides for the management of Cisco Flash Devices.
117
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

117 total
Object Name
ciscoFlashMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.10
RFC1155-SMI
Unknown
.1.3.6.1.4.1.9.9.10
ciscoFlashMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.10.1
ciscoFlashDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.10.1.1
ciscoFlashDevicesSupportedro
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.1
ciscoFlashDeviceTable
SEQUENCE OF CiscoFlashDeviceEntry
.1.3.6.1.4.1.9.9.10.1.1.2
ciscoFlashDeviceEntry
CiscoFlashDeviceEntry
.1.3.6.1.4.1.9.9.10.1.1.2.1
ciscoFlashDeviceIndex
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.2.1.1
ciscoFlashDeviceSizero
INTEGER -- Units -- bytes
.1.3.6.1.4.1.9.9.10.1.1.2.1.2
ciscoFlashDeviceMinPartitionSizero
INTEGER -- Units -- bytes
.1.3.6.1.4.1.9.9.10.1.1.2.1.3
ciscoFlashDeviceMaxPartitionsro
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.2.1.4
ciscoFlashDevicePartitionsro
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.2.1.5
ciscoFlashDeviceChipCountro
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.2.1.6
ciscoFlashDeviceNamero
DisplayString
.1.3.6.1.4.1.9.9.10.1.1.2.1.7
ciscoFlashDeviceDescrro
DisplayString
.1.3.6.1.4.1.9.9.10.1.1.2.1.8
ciscoFlashDeviceControllerro
DisplayString
.1.3.6.1.4.1.9.9.10.1.1.2.1.9
ciscoFlashDeviceCardro
InstancePointer -- Rsyntax OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.10.1.1.2.1.10
ciscoFlashDeviceProgrammingJumperro
Enumeration
.1.3.6.1.4.1.9.9.10.1.1.2.1.11
ciscoFlashDeviceInitTimero
TimeStamp -- Rsyntax TimeTicks
.1.3.6.1.4.1.9.9.10.1.1.2.1.12
ciscoFlashDeviceRemovablero
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.9.9.10.1.1.2.1.13
ciscoFlashChips
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.10.1.1.3
ciscoFlashChipTable
SEQUENCE OF CiscoFlashChipEntry
.1.3.6.1.4.1.9.9.10.1.1.3.1
ciscoFlashChipEntry
CiscoFlashChipEntry
.1.3.6.1.4.1.9.9.10.1.1.3.1.1
ciscoFlashChipIndex
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.3.1.1.1
ciscoFlashChipCodero
DisplayString
.1.3.6.1.4.1.9.9.10.1.1.3.1.1.2
ciscoFlashChipDescrro
DisplayString
.1.3.6.1.4.1.9.9.10.1.1.3.1.1.3
ciscoFlashChipWriteRetriesro
Counter
.1.3.6.1.4.1.9.9.10.1.1.3.1.1.4
ciscoFlashChipEraseRetriesro
Counter
.1.3.6.1.4.1.9.9.10.1.1.3.1.1.5
ciscoFlashChipMaxWriteRetriesro
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.3.1.1.6
ciscoFlashChipMaxEraseRetriesro
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.3.1.1.7
ciscoFlashPartitions
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.10.1.1.4
ciscoFlashPartitionTable
SEQUENCE OF CiscoFlashPartitionEntry
.1.3.6.1.4.1.9.9.10.1.1.4.1
ciscoFlashPartitionEntry
CiscoFlashPartitionEntry
.1.3.6.1.4.1.9.9.10.1.1.4.1.1
ciscoFlashPartitionIndex
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.4.1.1.1
ciscoFlashPartitionStartChipro
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.4.1.1.2
ciscoFlashPartitionEndChipro
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.4.1.1.3
ciscoFlashPartitionSizero
INTEGER -- Units -- bytes
.1.3.6.1.4.1.9.9.10.1.1.4.1.1.4
ciscoFlashPartitionFreeSpacero
Gauge -- Units -- bytes
.1.3.6.1.4.1.9.9.10.1.1.4.1.1.5
ciscoFlashPartitionFileCountro
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.4.1.1.6
ciscoFlashPartitionChecksumAlgorithmro
Enumeration
.1.3.6.1.4.1.9.9.10.1.1.4.1.1.7
ciscoFlashPartitionStatusro
Enumeration
.1.3.6.1.4.1.9.9.10.1.1.4.1.1.8
ciscoFlashPartitionUpgradeMethodro
Enumeration
.1.3.6.1.4.1.9.9.10.1.1.4.1.1.9
ciscoFlashPartitionNamero
DisplayString
.1.3.6.1.4.1.9.9.10.1.1.4.1.1.10
ciscoFlashPartitionNeedErasurero
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.9.9.10.1.1.4.1.1.11
ciscoFlashPartitionFileNameLengthro
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.4.1.1.12
ciscoFlashFiles
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.10.1.1.4.2
ciscoFlashFileTable
SEQUENCE OF CiscoFlashFileEntry
.1.3.6.1.4.1.9.9.10.1.1.4.2.1
ciscoFlashFileEntry
CiscoFlashFileEntry
.1.3.6.1.4.1.9.9.10.1.1.4.2.1.1
ciscoFlashFileIndex
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.4.2.1.1.1
ciscoFlashFileSizero
INTEGER
.1.3.6.1.4.1.9.9.10.1.1.4.2.1.1.2
ciscoFlashFileChecksumro
ChecksumString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.9.9.10.1.1.4.2.1.1.3
ciscoFlashFileStatusro
Enumeration
.1.3.6.1.4.1.9.9.10.1.1.4.2.1.1.4
ciscoFlashFileNamero
DisplayString
.1.3.6.1.4.1.9.9.10.1.1.4.2.1.1.5
ciscoFlashFileTypero
FlashFileType -- Rsyntax INTEGER { -- unknown(1), -- config(2), -- image(3), -- directory(4), -- crashinfo(5) -- }
.1.3.6.1.4.1.9.9.10.1.1.4.2.1.1.6
ciscoFlashOps
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.10.1.2
ciscoFlashCopyTable
SEQUENCE OF CiscoFlashCopyEntry
.1.3.6.1.4.1.9.9.10.1.2.1
ciscoFlashCopyEntry
CiscoFlashCopyEntry
.1.3.6.1.4.1.9.9.10.1.2.1.1
ciscoFlashCopySerialNumber
INTEGER
.1.3.6.1.4.1.9.9.10.1.2.1.1.1
ciscoFlashCopyCommandrw
Enumeration
.1.3.6.1.4.1.9.9.10.1.2.1.1.2
ciscoFlashCopyProtocolrw
Enumeration
.1.3.6.1.4.1.9.9.10.1.2.1.1.3
ciscoFlashCopyServerAddressrw
IpAddress
.1.3.6.1.4.1.9.9.10.1.2.1.1.4
ciscoFlashCopySourceNamerw
DisplayString
.1.3.6.1.4.1.9.9.10.1.2.1.1.5
ciscoFlashCopyDestinationNamerw
DisplayString
.1.3.6.1.4.1.9.9.10.1.2.1.1.6
ciscoFlashCopyRemoteUserNamerw
DisplayString
.1.3.6.1.4.1.9.9.10.1.2.1.1.7
ciscoFlashCopyStatusro
Enumeration
.1.3.6.1.4.1.9.9.10.1.2.1.1.8
ciscoFlashCopyNotifyOnCompletionrw
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.9.9.10.1.2.1.1.9
ciscoFlashCopyTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.9.9.10.1.2.1.1.10
ciscoFlashCopyEntryStatusrw
RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- }
.1.3.6.1.4.1.9.9.10.1.2.1.1.11
ciscoFlashPartitioningTable
SEQUENCE OF CiscoFlashPartitioningEntry
.1.3.6.1.4.1.9.9.10.1.2.2
ciscoFlashPartitioningEntry
CiscoFlashPartitioningEntry
.1.3.6.1.4.1.9.9.10.1.2.2.1
ciscoFlashPartitioningSerialNumber
INTEGER
.1.3.6.1.4.1.9.9.10.1.2.2.1.1
ciscoFlashPartitioningCommandrw
Enumeration
.1.3.6.1.4.1.9.9.10.1.2.2.1.2
ciscoFlashPartitioningDestinationNamerw
DisplayString
.1.3.6.1.4.1.9.9.10.1.2.2.1.3
ciscoFlashPartitioningPartitionCountrw
INTEGER
.1.3.6.1.4.1.9.9.10.1.2.2.1.4
ciscoFlashPartitioningPartitionSizesrw
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.9.9.10.1.2.2.1.5
ciscoFlashPartitioningStatusro
Enumeration
.1.3.6.1.4.1.9.9.10.1.2.2.1.6
ciscoFlashPartitioningNotifyOnCompletionrw
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.9.9.10.1.2.2.1.7
ciscoFlashPartitioningTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.9.9.10.1.2.2.1.8
ciscoFlashPartitioningEntryStatusrw
RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- }
.1.3.6.1.4.1.9.9.10.1.2.2.1.9
ciscoFlashMiscOpTable
SEQUENCE OF CiscoFlashMiscOpEntry
.1.3.6.1.4.1.9.9.10.1.2.3
ciscoFlashMiscOpEntry
CiscoFlashMiscOpEntry
.1.3.6.1.4.1.9.9.10.1.2.3.1
ciscoFlashMiscOpSerialNumber
INTEGER
.1.3.6.1.4.1.9.9.10.1.2.3.1.1
ciscoFlashMiscOpCommandrw
Enumeration
.1.3.6.1.4.1.9.9.10.1.2.3.1.2
ciscoFlashMiscOpDestinationNamerw
DisplayString
.1.3.6.1.4.1.9.9.10.1.2.3.1.3
ciscoFlashMiscOpStatusro
Enumeration
.1.3.6.1.4.1.9.9.10.1.2.3.1.4
ciscoFlashMiscOpNotifyOnCompletionrw
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.9.9.10.1.2.3.1.5
ciscoFlashMiscOpTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.9.9.10.1.2.3.1.6
ciscoFlashMiscOpEntryStatusrw
RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- }
.1.3.6.1.4.1.9.9.10.1.2.3.1.7
ciscoFlashMIBTrapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.10.1.3
ciscoFlashMIBTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.10.1.3.0
ciscoFlashCopyCompletionTrap
TRAP-TYPE
.1.3.6.1.4.1.9.9.10.1.3.0.1
ciscoFlashPartitioningCompletionTrap
TRAP-TYPE
.1.3.6.1.4.1.9.9.10.1.3.0.2
ciscoFlashMiscOpCompletionTrap
TRAP-TYPE
.1.3.6.1.4.1.9.9.10.1.3.0.3
ciscoFlashDeviceChangeTrap
TRAP-TYPE
.1.3.6.1.4.1.9.9.10.1.3.0.4
ciscoFlashDeviceInsertedNotif
TRAP-TYPE
.1.3.6.1.4.1.9.9.10.1.3.0.5
ciscoFlashDeviceRemovedNotif
TRAP-TYPE
.1.3.6.1.4.1.9.9.10.1.3.0.6
ciscoFlashCfg
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.10.1.4
ciscoFlashCfgDevInsNotifEnablerw
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.9.9.10.1.4.1
ciscoFlashCfgDevRemNotifEnablerw
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.9.9.10.1.4.2
ciscoFlashMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.10.2
Showing 100 of 117 OID objects

CISCO-FLASH-MIB Technical Reference Overview

The CISCO-FLASH-MIB SNMP MIB module published by Cisco defines 117 managed OID objects, including 69 scalar/column metrics, 7 SNMP tables, and 6 trap/notification events. Key tabular structures include ciscoFlashDeviceTable, ciscoFlashChipTable, ciscoFlashPartitionTable, ciscoFlashFileTable, ciscoFlashCopyTable, ciscoFlashPartitioningTable. Monitored SNMP traps/notifications include ciscoFlashCopyCompletionTrap, ciscoFlashPartitioningCompletionTrap, ciscoFlashMiscOpCompletionTrap, ciscoFlashDeviceChangeTrap, ciscoFlashDeviceInsertedNotif, ciscoFlashDeviceRemovedNotif.

Key OID Definitions in CISCO-FLASH-MIB

ciscoFlashDeviceTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.10.1.1.2

Table of Flash device properties for each initialized Flash device. Each Flash device installed in a system is detected, sized, and initialized when the system image boots up. For removable Flash devices, the device properties will be dynamically deleted and recreated as the device is removed and inserted. Note that in this case, the newly inserted device may not be the same as the earlier removed one. The ciscoFlashDeviceInitTime object is available for a management station to determine the time at which a device was initialized, and thereby detect the change of a removable device. A removable device that has not been installed will also have an entry in this table. This is to let a management station know about a removable device that has been removed. Since a removed device obviously cannot be sized and initialized, the table entry for such a device will have ciscoFlashDeviceSize equal to zero, and the following objects will have an indeterminate value: ciscoFlashDeviceMinPartitionSize, ciscoFlashDeviceMaxPartitions, ciscoFlashDevicePartitions, and ciscoFlashDeviceChipCount. ciscoFlashDeviceRemovable will be true to indicate it is removable.

ciscoFlashChipTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.10.1.1.3.1

Table of Flash device chip properties for each initialized Flash device. This table is meant primarily for aiding error diagnosis.

ciscoFlashPartitionTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.10.1.1.4.1

Table of flash device partition properties for each initialized flash partition. Whenever there is no explicit partitioning done, a single partition spanning the entire device will be assumed to exist. There will therefore always be atleast one partition on a device.

ciscoFlashFileTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.10.1.1.4.2.1

Table of information for files in a Flash partition.

ciscoFlashCopyTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.10.1.2.1

A table of Flash copy operation entries. Each entry represents a Flash copy operation (to or from Flash) that has been initiated.

ciscoFlashPartitioningTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.10.1.2.2

A table of Flash partitioning operation entries. Each entry represents a Flash partitioning operation that has been initiated.

ciscoFlashMiscOpTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.10.1.2.3

A table of misc Flash operation entries. Each entry represents a Flash operation that has been initiated.

ciscoFlashCopyCompletionTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.9.9.10.1.3.0.1

A ciscoFlashCopyCompletionTrap is sent at the completion of a flash copy operation if such a trap was requested when the operation was initiated.

ciscoFlashPartitioningCompletionTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.9.9.10.1.3.0.2

A ciscoFlashPartitioningCompletionTrap is sent at the completion of a partitioning operation if such a trap was requested when the operation was initiated.

ciscoFlashMiscOpCompletionTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.9.9.10.1.3.0.3

A ciscoFlashMiscOpCompletionTrap is sent at the completion of a miscellaneous flash operation (enumerated in ciscoFlashMiscOpCommand) if such a trap was requested when the operation was initiated.

ciscoFlashDeviceChangeTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.9.9.10.1.3.0.4

A ciscoFlashDeviceChangeTrap is sent whenever a removable Flash device is inserted or removed.

ciscoFlashDeviceInsertedNotifTRAP-TYPEnot-accessible
.1.3.6.1.4.1.9.9.10.1.3.0.5

A ciscoFlashDeviceInsertedNotif notification is sent whenever a removable Flash device is inserted.

ciscoFlashDeviceRemovedNotifTRAP-TYPEnot-accessible
.1.3.6.1.4.1.9.9.10.1.3.0.6

A ciscoFlashDeviceRemovedNotif notification is sent whenever a removable Flash device is removed.

ciscoFlashDevicesSupportedINTEGER(1..32)read-only
.1.3.6.1.4.1.9.9.10.1.1.1

Number of Flash devices supported by the system. If the system does not support any Flash devices, this MIB will not be loaded on that system. The value of this object will therefore be atleast 1.

ciscoFlashCfgDevInsNotifEnableTruthValueread-write
.1.3.6.1.4.1.9.9.10.1.4.1

Specifies whether or not a notification should be generated on the insertion of a Flash device. If the value of this object is 'true' then the ciscoFlashDeviceInsertedNotif notification will be generated. If the value of this object is 'false' then the ciscoFlashDeviceInsertedNotif notification will not be generated. It is the responsibility of the management entity to ensure that the SNMP administrative model is configured in such a way as to allow the notification to be delivered.

ciscoFlashCfgDevRemNotifEnableTruthValueread-write
.1.3.6.1.4.1.9.9.10.1.4.2

Specifies whether or not a notification should be generated on the removal of a Flash device. If the value of this object is 'true' then the ciscoFlashDeviceRemovedNotif notification will be generated. If the value of this object is 'false' then the ciscoFlashDeviceRemovedNotif notification will not be generated. It is the responsibility of the management entity to ensure that the SNMP administrative model is configured in such a way as to allow the notification to be delivered.

ciscoFlashDeviceEntryCiscoFlashDeviceEntrynot-accessible
.1.3.6.1.4.1.9.9.10.1.1.2.1

An entry in the table of flash device properties for each initialized flash device. Each entry can be randomly accessed by using ciscoFlashDeviceIndex as an index into the table. Note that removable devices will have an entry in the table even when they have been removed. However, a non-removable device that has not been installed will not have an entry in the table.

ciscoFlashDeviceIndexINTEGER(1..32)not-accessible
.1.3.6.1.4.1.9.9.10.1.1.2.1.1

Flash device sequence number to index within the table of initialized flash devices. The lowest value should be 1. The highest should be less than or equal to the value of the ciscoFlashDevicesSupported object.

ciscoFlashDeviceSizeINTEGERread-only
.1.3.6.1.4.1.9.9.10.1.1.2.1.2

Total size of the Flash device. For a removable device, the size will be zero if the device has been removed.

ciscoFlashDeviceMinPartitionSizeINTEGERread-only
.1.3.6.1.4.1.9.9.10.1.1.2.1.3

This object will give the minimum partition size supported for this device. For systems that execute code directly out of Flash, the minimum partition size needs to be the bank size. (Bank size is equal to the size of a chip multiplied by the width of the device. In most cases, the device width is 4 bytes, and so the bank size would be four times the size of a chip). This has to be so because all programming commands affect the operation of an entire chip (in our case, an entire bank because all operations are done on the entire width of the device) even though the actual command may be localized to a small portion of each chip. So when executing code out of Flash, one needs to be able to write and erase some portion of Flash without affecting the code execution. For systems that execute code out of DRAM or ROM, it is possible to partition Flash with a finer granularity (for eg., at erase sector boundaries) if the system code supports such granularity. This object will let a management entity know the minimum partition size as defined by the system. If the system does not support partitioning, the value will be equal to the device size in ciscoFlashDeviceSize. The maximum number of partitions that could be configured will be equal to the minimum of ciscoFlashDeviceMaxPartitions and (ciscoFlashDeviceSize / ciscoFlashDeviceMinPartitionSize).

ciscoFlashDeviceMaxPartitionsINTEGER(1..8)read-only
.1.3.6.1.4.1.9.9.10.1.1.2.1.4

Max number of partitions supported by the system for this Flash device. Default will be 1, which actually means that partitioning is not supported. Note that this value will be defined by system limitations, not by the flash device itself (for eg., the system may impose a limit of 2 partitions even though the device may be large enough to be partitioned into 4 based on the smallest partition unit supported). On systems that execute code out of Flash, partitioning is a way of creating multiple file systems in the Flash device so that writing into or erasing of one file system can be done while executing code residing in another file system. For systems executing code out of DRAM, partitioning gives a way of sub-dividing a large Flash device for easier management of files.

ciscoFlashDevicePartitionsINTEGERread-only
.1.3.6.1.4.1.9.9.10.1.1.2.1.5

Flash device partitions actually present. Number of partitions cannot exceed the minimum of ciscoFlashDeviceMaxPartitions and (ciscoFlashDeviceSize / ciscoFlashDeviceMinPartitionSize). Will be equal to at least 1, the case where the partition spans the entire device (actually no partitioning). A partition will contain one or more minimum partition units (where a minimum partition unit is defined by ciscoFlashDeviceMinPartitionSize).

ciscoFlashDeviceChipCountINTEGER(1..64)read-only
.1.3.6.1.4.1.9.9.10.1.1.2.1.6

Total number of chips within the Flash device. The purpose of this object is to provide information upfront to a management station on how much chip info to expect and possibly help double check the chip index against an upper limit when randomly retrieving chip info for a partition.

ciscoFlashDeviceNameDisplayString(SIZE(0..16))read-only
.1.3.6.1.4.1.9.9.10.1.1.2.1.7

Flash device name. This name is used to refer to the device within the system. Flash operations get directed to a device based on this name. The system has a concept of a default device. This would be the primary or most used device in case of multiple devices. The system directs an operation to the default device whenever a device name is not specified. The device name is therefore mandatory except when the operation is being done on the default device, or, the system supports only a single Flash device. The device name will always be available for a removable device, even when the device has been removed.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→