CISCO-FICON-MIB
AI MIB Summary
The CISCO-FICON-MIB enables monitoring and management of FICON channel connectivity, session states, and link statistics on Cisco MDS SAN switches acting as FICON Directors. It provides visibility into mainframe-to-device transport mechanisms, including error counters and port status, to ensure reliable enterprise data center storage traffic.
This is the FICON (FIber CONnection) MIB module.
FICON is an IBM standard of transport mechanism for communication between the mainframes and devices and is a major consideration for enterprise data centers.
The Cisco MDS Storage Area Network (SAN) switches provide the functionality of a FICON Director to the customers.
Main OID:
ciscoFiconMIB.1.3.6.1.4.1.9.9.375
140
Objects
Active
Status
8
Dependencies
Imported Objects
Objects
140 total| Object Name |
|---|
ciscoFiconMIBThis is the FICON (FIber CONnection) MIB module.
FICON is an IBM standard of transport mechanism
for communication between the mainframes and
devices and is a major consideration
for enterprise data centers.
The Cisco MDS Storage Area Network (SAN) switches
provide the functionality of a FICON Director to
the customers. MODULE-IDENTITY .1.3.6.1.4.1.9.9.375 |
IMPORTSThis is the FICON (FIber CONnection) MIB module.
FICON is an IBM standard of transport mechanism
for communication between the mainframes and
devices and is a major consideration
for enterprise data centers.
The Cisco MDS Storage Area Network (SAN) switches
provide the functionality of a FICON Director to
the customers. Unknown .1.3.6.1.4.1.9.9.375 |
ciscoFiconMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.375.0 |
cficonPortInfoChangeA FICON Port Change notification is
generated whenever the unit type of
the port changes. NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.375.0.1 |
ciscoFiconMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.375.1 |
ciscoFiconConfig OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.375.1.1 |
cficonPortSwapTableA table to issue the port swap command.
In FICON, lots of configuration in the host is associated
with a port-address. If the FICON port connecting the host
to the switch has some problem and the user
wants to connect the host to a different port in the
switch, one needs to swap the configuration of the
two ports. This command transparently swaps the
configuration of two ports without affecting the
host. SEQUENCE OF CficonPortSwapEntry .1.3.6.1.4.1.9.9.375.1.1.1 |
cficonPortSwapEntryA cficonPortSwapTable entry.
A management station wishing to create an entry should
first generate a pseudo-random serial number to be used
as the index to this sparse table. The station should
then create the associated instance of the row status
object. It must also, in the same PDU create the
associated instance of the cficonSwapPortNumberFirst
and cficonSwapPortNumberSecond objects.
Note that when creating a row in this table, the
cficonSwapPortEntryStatus, cficonSwapPortNumberFirst
and cficonSwapPortNumberSecond are all required.
Once the operation completes, the management station
should delete the entry. CficonPortSwapEntry .1.3.6.1.4.1.9.9.375.1.1.1.1 |
cficonPortSwapIndexAn arbitrary index for the swap command. Integer32 .1.3.6.1.4.1.9.9.375.1.1.1.1.1 |
cficonSwapPortNumberFirstThe first port number that needs to be swapped .rw CficonPortNumOrAddr .1.3.6.1.4.1.9.9.375.1.1.1.1.2 |
cficonSwapPortNumberSecondThe second port number that needs to be swapped.rw CficonPortNumOrAddr .1.3.6.1.4.1.9.9.375.1.1.1.1.3 |
cficonSwapPortEntryStatusIf this object is set to 'createAndGo(4)' then
the port configurations of the ports specified
by objects cficonSwapPortNumberFirst and
cficonSwapPortNumberSecond will be swapped.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.1.1.4 |
cficonVsanTableA table containing the objects to manage FICON
functionality in a VSAN. SEQUENCE OF CficonVsanEntry .1.3.6.1.4.1.9.9.375.1.1.2 |
cficonVsanEntryA cficonVsanTable entry. Each entry, identified
by vsanIndex, provides the objects to manage
FICON functionality in this VSAN,
identified by vsanIndex.
To create a vsan, only the
cficonVsanEntryStatus needs to be set
in the PDU. A vsan will be created with default
values for all the objects in the entry.
Once the vsan is created, the values of all
the writable objects within a row can be
modified. CficonVsanEntry .1.3.6.1.4.1.9.9.375.1.1.2.1 |
cficonVsanHostControlThe object indicates whether the host is allowed to
alter FICON Director connectivity parameters.
If 'true' the host is allowed to alter the parameters,
else it cannot.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.2.1.1 |
cficonVsanHostControlSwOfflineThe object specifying whether the host can put the VSAN
offline.
If 'true' it allows the host to put the VSAN offline,
else it cannot.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.2.1.2 |
cficonVsanHostControlClkAlrtModeThe object indicates whether director clock alert mode
is enabled or disabled.
If 'true', the mode is enabled, else it is disabled.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.2.1.3 |
cficonVsanSnmpControlThe object indicates whether network management system
is allowed to alter FICON director connectivity
parameters. If 'true', the network management system
is allowed to alter FICON director connectivity
parameters, else, it cannot.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.2.1.4 |
cficonVsanAutoSavePortAddrCfgThe object indicating whether the configuration will be
saved in the configuration file for this VSAN.
When an operator modifies a configuration, the running
configuration is modified. If this object is 'true', then
the configuration is saved in the configuration file as
well. If this object is 'false', then the running
configuration is not saved in the configuration
file.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.2.1.5 |
cficonVsanEnableCupThe object indicating Control Unit Port (CUP) is enabled.
If 'true', CUP is enabled, else it is disabled.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.2.1.6 |
cficonVsanCodePageThe EBCDIC Code page used for the exchange of
information with the host in this VSAN.rw Enumeration .1.3.6.1.4.1.9.9.375.1.1.2.1.7 |
cficonVsanCharSetThe Character Set used for the exchange of
of information with the host in this VSAN.rw Enumeration .1.3.6.1.4.1.9.9.375.1.1.2.1.8 |
cficonVsanKeyCounterA counter that is incremented every time there
is a configuration change.
This counter is used by the Host to keep track
of the number of configuration changes that
have taken place.ro Integer32 .1.3.6.1.4.1.9.9.375.1.1.2.1.9 |
cficonVsanUserAlertModeThe object indicating whether director user alert
mode is enabled or disabled.
If 'true', the mode is enabled. else it is
disabled.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.2.1.10 |
cficonVsanDeviceAllegienceThe object indicating whether CUP is in a allegiance
state. If it is in allegiance state with a channel,
it cannot accept any commands from any logical paths.
A CUP goes in an allegiance state when it accepts
command from a channel and forms 'an allegiance'
with it until the successful completion of the
channel program, at which point the CUP goes in
a an 'unlocked' mode.ro Enumeration .1.3.6.1.4.1.9.9.375.1.1.2.1.11 |
cficonVsanTimeThe system time in the VSAN. This could be set
either by the host or be the default global time
in the FICON Director. The default global time
is the local time in the FICON Director.
The format is as follows -
Wed Nov 5 18:53:52.172485 2003ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.2.1.12 |
cficonVsanHostOrDefaultTimeThe object indicating whether VSAN time is set by
the host or the time is global time within a FICON
Director. If 'true', the time was set by the host,
else it is same as the FICON Director's global time.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.2.1.13 |
cficonVsanCupNameThe name of CUP.rw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.375.1.1.2.1.14 |
cficonSetHostTimeControlThe object indicating whether VSAN time can be
set by the host.
If 'true', the host can set the time, else it
can not.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.2.1.15 |
cficonVsanClearAllegienceThe object used to clear a CUP allegiance.
If this object is set with value, 'clear(1)'
the CUP goes in a 'non-allegiance' or
'unlocked' mode as described in the description
of cficonVsanDeviceAllegience object above.rw Enumeration .1.3.6.1.4.1.9.9.375.1.1.2.1.16 |
cficonVsanEntryStatusThe status of this table entry.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.2.1.17 |
cficonVsanFiconStateThe object used to control the state of
the ports belonging to a vsan in the context
of the FICON functionality.
If this object is set to 'offline(1)'
all the ports belonging to the vsan, specified
by the vsanIndex are put in the suspended state.
If this object is set to 'online(2)'
all the ports belonging to the vsan, specified
by the vsanIndex are put in the operational state.rw Enumeration .1.3.6.1.4.1.9.9.375.1.1.2.1.18 |
cficonVsanSerialNumThe serial number of the FICON director.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.375.1.1.2.1.19 |
cficonPortTableA table listing the port information as
stored in the configuration file. SEQUENCE OF CficonPortEntry .1.3.6.1.4.1.9.9.375.1.1.3 |
cficonPortEntryA cficonPortTable entry. Each entry provides the
information about a port, identified by cficonPortAddr,
in the configuration file, identified by
cficonPortFilename, on this VSAN, identified by
vsanIndex. CficonPortEntry .1.3.6.1.4.1.9.9.375.1.1.3.1 |
cficonPortAddrThe Port Address of this port. CficonPortNumOrAddr .1.3.6.1.4.1.9.9.375.1.1.3.1.1 |
cficonPortBlockThe object indicates whether to block or unblock this
port. This is one of the port-connectivity parameters.
If 'true' this port is blocked, else it is unblocked.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.3.1.2 |
cficonPortNameThe name of this port.rw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.375.1.1.3.1.3 |
cficonProhibitPortNumbersThe list of ports that will be prohibited from
communication.
Each octet within the value of an object of this type,
specifies a set of eight ports, with the first
octet specifying ports 1 through 8, the second
octet specifying ports 9 through 16, etc.
Within each octet, the most significant bit represents
the lowest numbered port and the least significant
bit represents the highest numbered port.rw OCTET STRING .1.3.6.1.4.1.9.9.375.1.1.3.1.4 |
cficonPortRunCfgTableA table listing the port information as
stored in the running configuration.
Each port is identified by the port
address in the context of its vsan Index. SEQUENCE OF CficonPortRunCfgEntry .1.3.6.1.4.1.9.9.375.1.1.4 |
cficonPortRunCfgEntryA cficonPortRunCfgTable entry. Each entry provides the
information about a port (identified by cficonPortAddr),
on this VSAN (identified by vsanIndex), for the
running configuration. CficonPortRunCfgEntry .1.3.6.1.4.1.9.9.375.1.1.4.1 |
cficonPortRunCfgAddrThe address of this port. CficonPortNumOrAddr .1.3.6.1.4.1.9.9.375.1.1.4.1.1 |
cficonPortRunCfgBlockThe object indicating whether to block or unblock this
port.
If 'true' this port is blocked, else it is unblocked.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.4.1.2 |
cficonPortRunCfgNameThe port name of this port.rw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.375.1.1.4.1.3 |
cficonRunCfgProhibitPrtNumsThe list of ports that will be prohibited.
Each octet within the value of an object of this
type specifies a set of eight ports, with the first
octet specifying ports 1 through 8, the second
octet specifying ports 9 through 16, etc.
Within each octet, the most significant bit represents
the lowest numbered port and the least significant bit
represents the highest numbered port.rw OCTET STRING .1.3.6.1.4.1.9.9.375.1.1.4.1.4 |
cficonRunCfgTypeNumberThe type number for this FICON Director.ro DisplayString .1.3.6.1.4.1.9.9.375.1.1.4.1.5 |
cficonRunCfgModelNumberThe model number for this FICON Director. It is in the
form of ASCII characters.ro DisplayString .1.3.6.1.4.1.9.9.375.1.1.4.1.6 |
cficonRunCfgManufacturerThe name of the the company that
manufactured this FICON Director.ro DisplayString .1.3.6.1.4.1.9.9.375.1.1.4.1.7 |
cficonRunCfgPlantOfMfgThe plant code that identifies the plant
of manufacture of this FICON Director.ro DisplayString .1.3.6.1.4.1.9.9.375.1.1.4.1.8 |
cficonRunCfgSerialNumberThe sequence number assigned to this FICON
Director during manufacturing.ro DisplayString .1.3.6.1.4.1.9.9.375.1.1.4.1.9 |
cficonRunCfgUnitTypeThe peer type of the port that this port
is communicating.
channel - Host
controlUnit - Disk
fabric - Another SAN switchro Enumeration .1.3.6.1.4.1.9.9.375.1.1.4.1.10 |
cficonRunCfgPortIdThis is the identifier of the peer port.
If the peer port is channel, as described
by the instance of cficonRunCfgUnitType, then
cficonRunCfgPortId will be the CHPID (Channel
Path Identifier) of the channel path that
contains this peer port.
If the peer port is controlUnit, then
cficonRunCfgPortId will be 0.
If the peer port is fabric, then
cficonRunCfgPortId will be port address of the
interface on the peer switch.ro Integer32 .1.3.6.1.4.1.9.9.375.1.1.4.1.11 |
cficonRunCfgStatusThis object specifies the status of the row,
whether some specific columns in this row are
valid, invalid or old. These specific columns
are - cficonRunCfgProhibitPrtNums,
cficonRunCfgTypeNumber,
cficonRunCfgModelNumber,
cficonRunCfgManufacturer,
cficonRunCfgPlantOfMfg,
cficonRunCfgSerialNumber and
cficonRunCfgUnitType.
The only value that can be assigned by the Network
Management System(NMS) is 'invalid'. The NMS
cannot set this object to any other value (i.e 'valid'
or 'old').
valid - The information ( values of the other columns)
is guaranteed to be correct.
old - The information was valid before the port went
down. Although the information has not vanished,
it cannot be guaranteed.
invalid - When the port does not have the information
at all. (i.e. when the port comes up for the
first time or the NMS clears the information.rw Enumeration .1.3.6.1.4.1.9.9.375.1.1.4.1.12 |
cficonCfgFileTableA table listing the configuration files for each vsan. SEQUENCE OF CficonCfgFileEntry .1.3.6.1.4.1.9.9.375.1.1.5 |
cficonCfgFileEntryA cficonCfgFileTable entry. Each entry provides the
configuration file for a vsan (identified by vsanIndex)
and a file (identified by cficonCfgFilename).
Each entry lists the file status, the time the file
was last updated etc.
The cficonCfgFileRowStatus object is used to
create or delete a configuration file. For
creation or deletion, only the cficonCfgFileRowStatus
object needs to be set in the PDU.
cficonCfgFileCmd object is used to apply this
configuration file to the vsan specified by the
vsanIndex.
For example,
To create a configuration file 'cfg' for vsan 1,
the management application must do the
following -
cficonCfgFileRowStatus.1.cfg = createAndGo;
To delete the configuration file,
cficonCfgFileRowStatus.1.cfg = destroy;
To apply this configuration file,
cficonCfgFileCmd.1.cfg = apply; CficonCfgFileEntry .1.3.6.1.4.1.9.9.375.1.1.5.1 |
cficonCfgFilenameThe name of the configuration file. SnmpAdminString .1.3.6.1.4.1.9.9.375.1.1.5.1.1 |
cficonCfgFileDescrThe description of the configuration file.rw SnmpAdminString .1.3.6.1.4.1.9.9.375.1.1.5.1.2 |
cficonCfgFileStatusThe status of filename containing these ports.
Network Management station must check this object
before it can read the contents of the
configuration file. If it is 'locked', it means
that the host or the CLI or the network management
station is in the process of writing the contents
of this file. If it is 'locked' the the file cannot
be read. If it is 'unlocked', then the file
is ready to be read.ro Enumeration .1.3.6.1.4.1.9.9.375.1.1.5.1.3 |
cficonCfgFileLastUpdatedThe time this file was last updated.
The format is as follows -
Wed Nov 5 18:53:52.172485 2003ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.375.1.1.5.1.4 |
cficonCfgFileCmdThe object to apply this configuration file to the
VSAN identified by the vsanIndex. When reading this
object, a noOp(2) is returned.
open(3) opens this file for modifying.
close(4) closes this file.rw Enumeration .1.3.6.1.4.1.9.9.375.1.1.5.1.5 |
cficonCfgFileRowStatusThe rowStatus of this row.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.5.1.6 |
cficonCfgFileCmdStatusThe object to describe the status of the last 'apply'
command.
success - The last apply command was successful.
inProgress - The last apply command is still in the
process of execution.
failed - The last apply command failed.
notApplicable - The last apply command status is not
available.ro Enumeration .1.3.6.1.4.1.9.9.375.1.1.5.1.7 |
cficonCfgFileCmdErrorStringThe string describing the reason the the last 'apply'
command failed. This string needs to be polled only
in the case when the value of the cficonCfgFileCmdStatus
is 'failed'.ro SnmpAdminString .1.3.6.1.4.1.9.9.375.1.1.5.1.8 |
cficonPortNumIfTableA table listing the association of Port number to
its interface index. SEQUENCE OF CficonPortNumIfEntry .1.3.6.1.4.1.9.9.375.1.1.6 |
cficonPortNumIfEntryA cficonPortNumIfTable entry. Each entry provides
a mapping between the port number and its
interface index. CficonPortNumIfEntry .1.3.6.1.4.1.9.9.375.1.1.6.1 |
cficonPortNumberThe port number of this port. CficonPortNumOrAddr .1.3.6.1.4.1.9.9.375.1.1.6.1.1 |
cficonPortIfIndexThe interface index of this port. For ports that
are not installed, this object would be zero.rw InterfaceIndex (IF-MIB) .1.3.6.1.4.1.9.9.375.1.1.6.1.2 |
cficonPortAddrNumTableA table listing the association of Port address
to port number. SEQUENCE OF CficonPortAddrNumEntry .1.3.6.1.4.1.9.9.375.1.1.7 |
cficonPortAddrNumEntryA cficonPortAddrNumTable entry. Each entry
provides the port address to port number
mapping. CficonPortAddrNumEntry .1.3.6.1.4.1.9.9.375.1.1.7.1 |
cficonPortAddrPortAddrThe port address of this port. CficonPortNumOrAddr .1.3.6.1.4.1.9.9.375.1.1.7.1.1 |
cficonPortAddrPortNumberThe port number of this port.ro CficonPortNumOrAddr .1.3.6.1.4.1.9.9.375.1.1.7.1.2 |
cficonPortNumAddrTableA table listing the association of Port number to
its port number. SEQUENCE OF CficonPortNumAddrEntry .1.3.6.1.4.1.9.9.375.1.1.8 |
cficonPortNumAddrEntryA cficonPortNumAddrTable entry. Each entry provides
a mapping between the port number and its
port number. CficonPortNumAddrEntry .1.3.6.1.4.1.9.9.375.1.1.8.1 |
portAddrPortNumberThe port number of this port. CficonPortNumOrAddr .1.3.6.1.4.1.9.9.375.1.1.8.1.1 |
portAddressThe port address of this port.ro CficonPortNumOrAddr .1.3.6.1.4.1.9.9.375.1.1.8.1.2 |
cficonDirHistTableA table listing the director history buffer.
Director History Buffer is a mechanism to
determine those ports that have changed
their configuration for a particular
value of a key counter.
The FICON Director maintains a change vector
of 256 bits (32 bytes) and an associated
key counter. This table lists this vector
for a given key counter. SEQUENCE OF CficonDirHistEntry .1.3.6.1.4.1.9.9.375.1.1.9 |
cficonDirHistEntryA row in the cficonDirHistTable, identified
by the vsanIndex and the key counter. CficonDirHistEntry .1.3.6.1.4.1.9.9.375.1.1.9.1 |
cficonDirHistKeyCounterThe key counter. Integer32 .1.3.6.1.4.1.9.9.375.1.1.9.1.1 |
cficonDirHistPortNumbersThe list of ports that have configuration change for
a value of cficonDirHistKeyCounter. If a port has
configuration change, its bit position will be 1.
Each octet within the value of an object of this type,
specifies a set of eight ports, with the first
octet specifying ports 1 through 8, the second
octet specifying ports 9 through 16, etc.
Within each octet, the most significant bit represents
the lowest numbered port and the least significant bit
represents the highest numbered port.ro OCTET STRING .1.3.6.1.4.1.9.9.375.1.1.9.1.2 |
cficonStatsTableA table listing the FICON Statistics . SEQUENCE OF CficonStatsEntry .1.3.6.1.4.1.9.9.375.1.1.10 |
cficonStatsEntryAn entry listing the FICON statistics for
FICON port. CficonStatsEntry .1.3.6.1.4.1.9.9.375.1.1.10.1 |
cfStatsFramePacingTimeNumber of 2.5 microsecond units that frame
transmission is blocked due to zero credit.ro Counter32 .1.3.6.1.4.1.9.9.375.1.1.10.1.1 |
cfStatsDispErrorsInFrameNumber of frames with disparity errors.ro Counter32 .1.3.6.1.4.1.9.9.375.1.1.10.1.2 |
cfStatsEOFErrsNumber of frames with EOF errors.ro Counter32 .1.3.6.1.4.1.9.9.375.1.1.10.1.3 |
cfStatsDispErrsOutOfFrameNumber of frames with OOF errors.ro Counter32 .1.3.6.1.4.1.9.9.375.1.1.10.1.4 |
cfStatsInvalidOrderSetsNumber of invalid or unrecognizable Order
Sets outside of frames.ro Counter32 .1.3.6.1.4.1.9.9.375.1.1.10.1.5 |
cfStatsErrorSummaryThis counter contains a sum of the errors
counted by a set of the other defined error
counters.ro Counter32 .1.3.6.1.4.1.9.9.375.1.1.10.1.6 |
cficonShowPortsAn object to control which ports are displayed.
If set to all(1), all the ports, regardless whether
they are installed or not are displayed in the
cficonPortTable and cificonPortRunCfgTable.
If set to 'installed', only the ports that are
installed ports are displayed in the
cficonPortTable and cificonPortRunCfgTable.rw Enumeration .1.3.6.1.4.1.9.9.375.1.1.11 |
cficonLinkIncidentTableA table listing the link incidents in a FICON
interface. A Link incident is an event when
the interface experiences the conditions described
in the cficonLinkIncident object. SEQUENCE OF CficonLinkIncidentEntry .1.3.6.1.4.1.9.9.375.1.1.12 |
cficonLinkIncidentEntryAn entry listing the cficonLinkIncidentTable. CficonLinkIncidentEntry .1.3.6.1.4.1.9.9.375.1.1.12.1 |
cficonLinkIncidentThe type of link incident that occurred on an interface.
bitErrThreshExceeded - Bit Error Threshold exceeded.
lossOfSignalOrSync - Loss of Signal or Sync message.
nosReceived - NOS msg Received
NOS - Non Operational State
primitiveSeqTimeOut - Primitive Timeout
invalidPrimitiveSeq - Invalid Primitive sequencero Enumeration .1.3.6.1.4.1.9.9.375.1.1.12.1.1 |
cficonLinkIncidentTimeThe time at which the link incident happened.
The format is as follows -
Wed Nov 5 18:53:52.172485 2003ro DisplayString .1.3.6.1.4.1.9.9.375.1.1.12.1.2 |
cficonLinkIncidentClearThe object used to clear the link incident
for an interface.rw Enumeration .1.3.6.1.4.1.9.9.375.1.1.12.1.3 |
cficonCfgFileCupNameTableA table listing the CUP names for each vsan
in a configuration file. SEQUENCE OF CficonCfgFileCupNameEntry .1.3.6.1.4.1.9.9.375.1.1.13 |
cficonCfgFileCupNameEntryA cficonCfgFileCupNameTable entry. Each entry
provides the CUP name for a VSAN
(identified by vsanIndex)
and a file (identified by cficonCfgFilename). CficonCfgFileCupNameEntry .1.3.6.1.4.1.9.9.375.1.1.13.1 |
cficonCfgFileCupNameThe name of CUP.rw SnmpAdminString .1.3.6.1.4.1.9.9.375.1.1.13.1.1 |
cficonConfigCopyTableA table of config-copy requests. SEQUENCE OF CficonConfigCopyEntry .1.3.6.1.4.1.9.9.375.1.1.14 |
cficonConfigCopyEntryA config-copy request.
A management station wishing to create an entry should
first generate a random serial number to be used
as the index to this sparse table. The station should
then create the associated instance of the row status
object.
This config-copy operation is only to copy the running
configuration to startup configuration for FICON.
Once the appropriate instance of all the configuration
objects have been created, either by an explicit SNMP
set request or by default, the row status should be set
to active to initiate the request. Note that this entire
procedure may be initiated via a single set request
which specifies a row status of createAndGo.
Once the config-copy request has been created (i.e. the
cfCopyEntryRowStatus has been made active), the entry
cannot be modified - the only operation possible
after this is to delete the row.
Once the request completes, the management station
should retrieve the value of the status object
and should then delete the entry. In order
to prevent old entries from clogging the table,
entries will be aged out, but an entry will never be
deleted within 5 minutes of completing. CficonConfigCopyEntry .1.3.6.1.4.1.9.9.375.1.1.14.1 |
cficonConfigCopyIndexObject which specifies a unique entry in the
cficonConfigCopyTable. A management station wishing
to initiate a config-copy operation should use a
random value for this object when creating
an instance of a cficonConfigCopyEntry. Unsigned32 .1.3.6.1.4.1.9.9.375.1.1.14.1.1 |
cficonCopyStateSpecifies the result of this config-copy request.
This value of this object is instantiated only after
the row has been instantiated, i.e. after the
cficonCopyEntryRowStatus has been made active.ro Enumeration .1.3.6.1.4.1.9.9.375.1.1.14.1.2 |
cficonCopyFailReasonAn error string describing the reason the copy
failed.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.375.1.1.14.1.3 |
cficonCopyEntryRowStatusThe status of this table entry. Once the entry
status is set to active, the associated entry cannot
be modified until the request completes
(cficonCopyState transitions to successful or
failed state).rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.14.1.4 |
cficonAutoSaveStateThe object indicates whether auto save state is
enabled or disabled.
Enabling the auto save state, saves the configuration
to the configuration file whenever a configuration
change is made.
If the cficonAutoSaveState is disabled (false), the
configuration change is not saved to the configuration
file.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.15 |
ciscoFiconPortMap OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.375.1.1.16 |
cficonPortMap1The port map1.
This object contains information specific to
third party vendor and the usage is vendor
specific.
Each record is 6 bytes long and there can be up to
42 records in this object.
Each record consists of the following -
0-3 bytes - IfIndex
byte 4 - Port Address
byte 5 - Unit Typerodeprecated OCTET STRING .1.3.6.1.4.1.9.9.375.1.1.16.1 |
cficonPortMap2The port map2.
This object contains information specific to
third party vendor and the usage is vendor
specific.
Each record is 6 bytes long and there can be up to
42 records in this object.
Each record consists of the following -
0-3 bytes - IfIndex
byte 4 - Port Address
byte 5 - Unit Typerodeprecated OCTET STRING .1.3.6.1.4.1.9.9.375.1.1.16.2 |
cficonPortMap3The port map3.
This object contains information specific to
third party vendor and the usage is vendor
specific.
Each record is 6 bytes long and there can be up to
42 records in this object.
Each record consists of the following -
0-3 bytes - IfIndex
byte 4 - Port Address
byte 5 - Unit Typerodeprecated OCTET STRING .1.3.6.1.4.1.9.9.375.1.1.16.3 |
cficonPortMap4The port map4.
This object contains information specific to
third party vendor and the usage is vendor
specific.
Each record is 6 bytes long and there can be up to
42 records in this object.
Each record consists of the following -
0-3 bytes - IfIndex
byte 4 - Port Address
byte 5 - Unit Typerodeprecated OCTET STRING .1.3.6.1.4.1.9.9.375.1.1.16.4 |
cficonPortMap5The port map5.
This object contains information specific to
third party vendor and the usage is vendor
specific.
Each record is 6 bytes long and there can be up to
42 records in this object.
Each record consists of the following -
0-3 bytes - IfIndex
byte 4 - Port Address
byte 5 - Unit Typerodeprecated OCTET STRING .1.3.6.1.4.1.9.9.375.1.1.16.5 |
cficonPortMap6The port map6.
This object contains information specific to
third party vendor and the usage is vendor
specific.
Each record is 6 bytes long and there can be up to
42 records in this object.
Each record consists of the following -
0-3 bytes - IfIndex
byte 4 - Port Address
byte 5 - Unit Typerodeprecated OCTET STRING .1.3.6.1.4.1.9.9.375.1.1.16.6 |
cficonPortMapMaxNumber of port map objects.ro Integer32 .1.3.6.1.4.1.9.9.375.1.1.16.7 |
cficonPortMapTableThe port map table.
This table contains the list of port map objects
to carry the information of IfIndex, port Address,
unit Type and Port Number for all ports. SEQUENCE OF CficonPortMapEntry .1.3.6.1.4.1.9.9.375.1.1.16.8 |
cficonPortMapEntryThe port map entry.
This entry consists of a index number indicating
a set of ports and a port map object carrying
certain port attributes for these ports. CficonPortMapEntry .1.3.6.1.4.1.9.9.375.1.1.16.8.1 |
cficonPortMapIndexThe port map index.
This number indicates the group of ports
described by the port map object. Integer32 .1.3.6.1.4.1.9.9.375.1.1.16.8.1.1 |
cficonPortMapObjThe port map object.
This object contains information specific to
third party vendor and the usage is vendor
specific.
Each record is 7 bytes long and there can be up to
36 records in this object.
Each record consists of the following -
0-3 bytes - IfIndex
byte 4 - Port Address
byte 5 - Unit Type
byte 6 - Port Numberro OCTET STRING .1.3.6.1.4.1.9.9.375.1.1.16.8.1.2 |
cficonSlotPortNumTableChassis slot port number table.
This table contains the list of all reserved
port numbers for all slots of the chassis. SEQUENCE OF CficonSlotPortNumEntry .1.3.6.1.4.1.9.9.375.1.1.17 |
cficonSlotPortNumEntryChassis slot port number entry.
This entry has the slot number and reserved
port numbers for this slot. CficonSlotPortNumEntry .1.3.6.1.4.1.9.9.375.1.1.17.1 |
cficonSlotIndexThe chassis slot number. Integer32 .1.3.6.1.4.1.9.9.375.1.1.17.1.1 |
cficonSlotReservedPNChassis slot port numbers.
Reserved port numbers for one chassis slot.
There can be up to 64 port numbers reserved
for each slot in the chassis.rw OCTET STRING .1.3.6.1.4.1.9.9.375.1.1.17.1.2 |
cficonLogicReservedPNReserved port numbers for logical ports.
There can be up to 256 port numbers reserved
for logical ports.rw OCTET STRING .1.3.6.1.4.1.9.9.375.1.1.18 |
cficonRlirErlTableA table of Nx_Ports that have registered to
receive RLIRs on all VSANs on the local
switch. SEQUENCE OF CficonRlirErlEntry .1.3.6.1.4.1.9.9.375.1.1.19 |
cficonRlirErlEntryAn entry (conceptual row) containing
information about an Nx_Port which has registered
to receive RLIRs on the VSAN indicated by
vsanIndex. CficonRlirErlEntry .1.3.6.1.4.1.9.9.375.1.1.19.1 |
cficonRlirErlFcIdThe Fibre Channel Identifier (FC-ID) of the
subscribing Nx_Port. FcAddressId (CISCO-ST-TC) .1.3.6.1.4.1.9.9.375.1.1.19.1.1 |
cficonRlirErlFormatIndicates the device type for which the Nx_Port
is interested in receiving RLIR ELS. Unsigned32 .1.3.6.1.4.1.9.9.375.1.1.19.1.2 |
cficonRlirErlRegTypeThis object indicates the type of registration
desired by the subscriber.
conditionalRx(1) - the Nx_Port is registered as
a valid recipient of
subsequent RLIRs. But such an
Nx_Port is chosen as the
recipient of a link incident
record only if no other
recipients from the ERL on
this VSAN have been chosen.
alwaysRx(2) - the Nx_Port is registered as
a valid recipient of
subsequent RLIRs. Such an
Nx_Port is always chosen as a
recipient of a link incident
record.ro Enumeration .1.3.6.1.4.1.9.9.375.1.1.19.1.3 |
cficonInterfaceSwapTableThis table provides a management application with the
capability to swap the configuration of two specified
interfaces.
In FICON, a host associates a great deal of configuration
data with a port-address. If the FICON port connecting
the host to the switch has some problem and the user
wants to connect the host to a different port in the
switch, one needs to swap the configuration of the
two ports. This command transparently swaps the
configuration of two ports without affecting the
host. SEQUENCE OF CficonInterfaceSwapEntry .1.3.6.1.4.1.9.9.375.1.1.20 |
cficonInterfaceSwapEntryA cficonInterfaceSwapTable entry contains 2 interface
indices to be swapped among other objects.
A management station wishing to create an entry should
first obtain a unique serial number, e.g. get the
cficonInterfaceSwapNextIndex scalar as the index
to this sparse table. The station should
then create the associated instance of the row status
object.
Note that when creating a row in this table, the
cficonSwapPortEntryStatus, cficonSwapInterfaceIndexFirst
and cficonSwapInterfaceIndexSecond are all required.
The values of cficonSwapInterfaceIndexFirst and
cficonSwapInterfaceIndexSecond should be different.
If for any reason the new row can not be created,
no swap action will be performed.
If the table entry creation is successful, the value of
cficonSwapInterfaceActionStatus will be pending(1) first
and the SNMP response will be returned as success.
When the swap starts, the value will be executing(2).
After the swap action is done, the value will be either
success(3) or failure(4). cficonSwapInterfaceFailReason
contains the failure reason to indicate where the failure
is from. cficonSwapInterfaceSystemError is a user
readable description given by the failure causing
sub-module.
The management station should delete the entry after
the value of cficonSwapInterfaceActionStatus being either
success(3) or failure(4). CficonInterfaceSwapEntry .1.3.6.1.4.1.9.9.375.1.1.20.1 |
cficonInterfaceSwapIndexAn arbitrary index for the swap command. Integer32 .1.3.6.1.4.1.9.9.375.1.1.20.1.1 |
cficonSwapInterfaceIndexFirstThe first port number that needs to be swapped .rw InterfaceIndex (IF-MIB) .1.3.6.1.4.1.9.9.375.1.1.20.1.2 |
cficonSwapInterfaceIndexSecondThe second port number that needs to be swapped.rw InterfaceIndex (IF-MIB) .1.3.6.1.4.1.9.9.375.1.1.20.1.3 |
cficonSwapInterfaceActionStatusThe status of the port swap request.
pending - the request is waiting to be processed by
the device.
executing - the request is currently being processed
by the device.
success - the request has been completed successfully by
the device.
failure - the request failed.ro Enumeration .1.3.6.1.4.1.9.9.375.1.1.20.1.4 |
cficonSwapInterfaceFailReasonThe reason of failed port swap request
other - the failure is caused by other sub-module.
none - no failure.
dmFailure - the failure is caused by Domain Manager.
ficonFailure - the failure is caused by FICON Manager.
pmFailure - the failure is caused by Port Manager.
psmFailure - the failure is caused by Port Security
Manager.
qosFailure - the failure is caused by QOS sub-module.
spanFailure - the failure is caused by SPAN sub-module.
zsFailure - the failure is caused by Zone Server.ro Enumeration .1.3.6.1.4.1.9.9.375.1.1.20.1.5 |
cficonSwapInterfaceSystemErrorA system error string readable by user for the failed
swap action.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.375.1.1.20.1.6 |
cficonSwapInterfaceEntryStatusIf this object is set to 'active(1)' then
the port configurations of the ports specified
by objects cficonSwapInterfaceIndexFirst and
cficonSwapInterfaceIndexSecond will be swapped.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.1.20.1.7 |
cficonInterfaceSwapNextIndexNext unique index available for creating new entry
in the FICON interface swap table.ro Integer32 .1.3.6.1.4.1.9.9.375.1.1.21 |
ciscoFiconGlobal OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.375.1.2 |
cficonDefaultPortBlockThis object indicates the default state which whether
to prohibit traffic or allow traffic among all External
Ports of a new FICON VSAN.
If 'true' the default state is prohibit all traffic,
else the default state is allow all traffic.
The default values of the cficonProhibitPortNumbers
and the cficonRunCfgProhibitPrtNums in a newly created
FICON VSAN are consistent with the state of this object.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.375.1.2.1 |
ciscoFiconMIBConform OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.375.2 |
ciscoFiconCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.375.2.1 |
ciscoFiconGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.375.2.2 |