CISCO-FC-MULTICAST-MIB
The CISCO-FC-MULTICAST-MIB enables monitoring and configuration of Fibre Channel multicast groups, membership states, and traffic statistics on Cisco SAN switches. It provides visibility into multicast session parameters and group membership to ensure reliable data replication and storage fabric operations.
Imported Objects
Objects
13 total| Object Name |
|---|
ciscoFcMulticastMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.435 |
ciscoFcMulticastNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.435.0 |
ciscoFcMulticastMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.435.1 |
cfmConfiguration OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.435.1.1 |
cfmMulticastRootTable SEQUENCE OF CfmMulticastRootEntry .1.3.6.1.4.1.9.9.435.1.1.1 |
cfmMulticastRootEntry CfmMulticastRootEntry .1.3.6.1.4.1.9.9.435.1.1.1.1 |
cfmMulticastRootConfigModerw CfmMulticastRootMode .1.3.6.1.4.1.9.9.435.1.1.1.1.1 |
cfmMulticastRootOperModero CfmMulticastRootMode .1.3.6.1.4.1.9.9.435.1.1.1.1.2 |
cfmMulticastRootDomainIdro DomainIdOrZero (CISCO-ST-TC) .1.3.6.1.4.1.9.9.435.1.1.1.1.3 |
cfmMulticastRootRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.435.1.1.1.1.4 |
ciscoFcMulticaseConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.435.2 |
ciscoFcMulticastMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.435.2.1 |
ciscoFcMulticastMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.435.2.2 |
CISCO-FC-MULTICAST-MIB Technical Reference Overview
The CISCO-FC-MULTICAST-MIB SNMP MIB module published by Cisco defines 13 managed OID objects, including 4 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.435. Key tabular structures include cfmMulticastRootTable.
Key OID Definitions in CISCO-FC-MULTICAST-MIB
.1.3.6.1.4.1.9.9.435MIB module for monitoring and configuring Fibre Channel Multicast feature.
.1.3.6.1.4.1.9.9.435.1.1.1This table allows the users to configure and monitor the FC Multicast parameters on all the VSANs configured on the local switch. An entry is automatically created in this table if there is an entry in the fspfTable (defined in CISCO-FSPF-MIB) and fspfOperStatus (defined in CISCO-FSPF-MIB) for that entry is 'up'. An entry is automatically deleted from this table if either : a) the fspfOperStatus in the fspfTable entry for the corresponding VSAN changes to 'down'. or b) the fspfTable entry for the corresponding VSAN is deleted. Entries in this table can be created via cfmMulticastRootRowStatus only as the means to specify non-default parameter values for a VSAN either because the VSAN is suspended or fspfOperStatus (defined in CISCO-FSPF-MIB) for that VSAN is 'down' (VSAN state is indicated by object vsanOperState which is defined in CISCO-VSAN-MIB). So an entry in this table exists when one or both of these conditions holds: - one or more configuration parameters have non-default values for a VSAN which is either suspended or the fspfOperStatus for that VSAN is down. - the fspfOperStatus for VSAN is 'up'. This has a number of consequences: - an entry exists for a suspended VSAN whenever that VSAN has non-default parameters. - an entry cannot be created (via cfmMulticastRootRowStatus) for a VSAN with default parameters; instead, the agent creates/deletes an entry for a VSAN with default parameters according to whether the fspfOperStatus is 'up' or 'down'. - an entry can not be created via cfmMulticastRootRowStatus unless non-default parameter values are (simultaneously) configured for a VSAN whose fspfOperStatus is 'down'. - deleting an entry via cfmMulticastRootRowStatus when either the VSAN is suspended and configured with non-default values or the VSAN is active, is equivalent to resetting its parameters to their default values. If an entry is configured with default-values and the VSAN is in suspended state, then the entry would be deleted.
.1.3.6.1.4.1.9.9.435.1.1.1.1This entry contains the multicase parameters on this VSAN.
.1.3.6.1.4.1.9.9.435.1.1.1.1.1The configured multicast root mode on this VSAN.
.1.3.6.1.4.1.9.9.435.1.1.1.1.2The operational multicast root mode on this VSAN.
.1.3.6.1.4.1.9.9.435.1.1.1.1.3The domainID of the multicast root on this VSAN.
.1.3.6.1.4.1.9.9.435.1.1.1.1.4The status of conceptual row on this VSAN. This object can be used to create an entry only if either the corresponding VSAN is suspended or the fspfOperStatus is down. If the VSAN is either not-existent or fspfOperStatus is up, the create will fail.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.