CISCO-FC-MGMT-MIB
The CISCO-FC-MGMT-MIB enables monitoring and management of Fibre Channel-attached storage devices and switches, specifically tracking interface statistics, port states, and FC-specific error counters. This module implements Cisco's vendor-specific adaptation of the IETF IPS Fibre Channel Management MIB draft to facilitate granular visibility into SAN fabric health and performance.
Imported Objects
Objects
151 total| Object Name |
|---|
ciscoFcMgmtMIB MODULE-IDENTITY .1.3.6.1.4.1.9.10.999999 |
cfcmgmtObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.999999.1 |
cfcmInstanceTable SEQUENCE OF CfcmInstanceEntry .1.3.6.1.4.1.9.10.999999.1.1 |
cfcmInstanceEntry CfcmInstanceEntry .1.3.6.1.4.1.9.10.999999.1.1.1 |
cfcmInstanceIndex Unsigned32 .1.3.6.1.4.1.9.10.999999.1.1.1.1 |
cfcmInstanceWwnro CfcmFcNameIdOrZero .1.3.6.1.4.1.9.10.999999.1.1.1.2 |
cfcmInstanceFunctionsro CfcmFcUnitFunctions .1.3.6.1.4.1.9.10.999999.1.1.1.3 |
cfcmInstancePhysicalIndexro CfcmPhysicalIndexOrZero .1.3.6.1.4.1.9.10.999999.1.1.1.4 |
cfcmInstanceSoftwareIndexro CfcmHrSWInstalledIndexOrZero .1.3.6.1.4.1.9.10.999999.1.1.1.5 |
cfcmInstanceStatusro Enumeration .1.3.6.1.4.1.9.10.999999.1.1.1.6 |
cfcmInstanceTextNamerw SnmpAdminString .1.3.6.1.4.1.9.10.999999.1.1.1.7 |
cfcmInstanceDescrrw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.10.999999.1.1.1.8 |
cfcmInstanceFabricIdro CfcmFcNameIdOrZero .1.3.6.1.4.1.9.10.999999.1.1.1.9 |
cfcmSwitchTable SEQUENCE OF CfcmSwitchEntry .1.3.6.1.4.1.9.10.999999.1.2 |
cfcmSwitchEntry CfcmSwitchEntry .1.3.6.1.4.1.9.10.999999.1.2.1 |
cfcmSwitchIndex Unsigned32 .1.3.6.1.4.1.9.10.999999.1.2.1.1 |
cfcmSwitchDomainIdrw CfcmDomainIdOrZero .1.3.6.1.4.1.9.10.999999.1.2.1.2 |
cfcmSwitchPrincipalro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.10.999999.1.2.1.3 |
cfcmPortTable SEQUENCE OF CfcmPortEntry .1.3.6.1.4.1.9.10.999999.1.3 |
cfcmPortEntry CfcmPortEntry .1.3.6.1.4.1.9.10.999999.1.3.1 |
cfcmPortInstanceIndexro Unsigned32 .1.3.6.1.4.1.9.10.999999.1.3.1.1 |
cfcmPortWwnro CfcmFcNameIdOrZero .1.3.6.1.4.1.9.10.999999.1.3.1.2 |
cfcmPortNodeWwnro CfcmFcNameIdOrZero .1.3.6.1.4.1.9.10.999999.1.3.1.3 |
cfcmPortAdminTyperw CfcmFcPortType .1.3.6.1.4.1.9.10.999999.1.3.1.4 |
cfcmPortOperTypero CfcmFcPortType .1.3.6.1.4.1.9.10.999999.1.3.1.5 |
cfcmPortFcCapClassro CfcmFcClasses .1.3.6.1.4.1.9.10.999999.1.3.1.6 |
cfcmPortFcOperClassro CfcmFcClasses .1.3.6.1.4.1.9.10.999999.1.3.1.7 |
cfcmPortTransmitterTypero Enumeration .1.3.6.1.4.1.9.10.999999.1.3.1.8 |
cfcmPortConnectorTypero Enumeration .1.3.6.1.4.1.9.10.999999.1.3.1.9 |
cfcmPortSerialNumberro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.10.999999.1.3.1.10 |
cfcmPortPhysicalNumberro Unsigned32 .1.3.6.1.4.1.9.10.999999.1.3.1.11 |
cfcmPortAdminSpeedrw Enumeration .1.3.6.1.4.1.9.10.999999.1.3.1.12 |
cfcmPortCapProtocolsro Bits .1.3.6.1.4.1.9.10.999999.1.3.1.13 |
cfcmPortOperProtocolsro Bits .1.3.6.1.4.1.9.10.999999.1.3.1.14 |
cfcmPortStatsTable SEQUENCE OF CfcmPortStatsEntry .1.3.6.1.4.1.9.10.999999.1.4 |
cfcmPortStatsEntry CfcmPortStatsEntry .1.3.6.1.4.1.9.10.999999.1.4.1 |
cfcmPortBBCreditZerosro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.1 |
cfcmPortFullInputBuffersro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.2 |
cfcmPortClass2RxFramesro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.3 |
cfcmPortClass2RxOctetsro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.4 |
cfcmPortClass2TxFramesro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.5 |
cfcmPortClass2TxOctetsro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.6 |
cfcmPortClass2Discardsro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.7 |
cfcmPortClass2RxFbsyFramesro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.8 |
cfcmPortClass2RxPbsyFramesro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.9 |
cfcmPortClass2RxFrjtFramesro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.10 |
cfcmPortClass2RxPrjtFramesro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.11 |
cfcmPortClass2TxFbsyFramesro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.12 |
cfcmPortClass2TxPbsyFramesro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.13 |
cfcmPortClass2TxFrjtFramesro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.14 |
cfcmPortClass2TxPrjtFramesro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.15 |
cfcmPortClass3RxFramesro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.16 |
cfcmPortClass3RxOctetsro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.17 |
cfcmPortClass3TxFramesro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.18 |
cfcmPortClass3TxOctetsro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.19 |
cfcmPortClass3Discardsro Counter64 .1.3.6.1.4.1.9.10.999999.1.4.1.20 |
cfcmPortClassFRxFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.4.1.21 |
cfcmPortClassFRxOctetsro Counter32 .1.3.6.1.4.1.9.10.999999.1.4.1.22 |
cfcmPortClassFTxFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.4.1.23 |
cfcmPortClassFTxOctetsro Counter32 .1.3.6.1.4.1.9.10.999999.1.4.1.24 |
cfcmPortClassFDiscardsro Counter32 .1.3.6.1.4.1.9.10.999999.1.4.1.25 |
cfcmPortLcStatsTable SEQUENCE OF CfcmPortLcStatsEntry .1.3.6.1.4.1.9.10.999999.1.5 |
cfcmPortLcStatsEntry CfcmPortLcStatsEntry .1.3.6.1.4.1.9.10.999999.1.5.1 |
cfcmPortLcBBCreditZerosro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.1 |
cfcmPortLcFullInputBuffersro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.2 |
cfcmPortLcClass2RxFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.3 |
cfcmPortLcClass2RxOctetsro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.4 |
cfcmPortLcClass2TxFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.5 |
cfcmPortLcClass2TxOctetsro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.6 |
cfcmPortLcClass2Discardsro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.7 |
cfcmPortLcClass2RxFbsyFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.8 |
cfcmPortLcClass2RxPbsyFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.9 |
cfcmPortLcClass2RxFrjtFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.10 |
cfcmPortLcClass2RxPrjtFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.11 |
cfcmPortLcClass2TxFbsyFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.12 |
cfcmPortLcClass2TxPbsyFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.13 |
cfcmPortLcClass2TxFrjtFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.14 |
cfcmPortLcClass2TxPrjtFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.15 |
cfcmPortLcClass3RxFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.16 |
cfcmPortLcClass3RxOctetsro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.17 |
cfcmPortLcClass3TxFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.18 |
cfcmPortLcClass3TxOctetsro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.19 |
cfcmPortLcClass3Discardsro Counter32 .1.3.6.1.4.1.9.10.999999.1.5.1.20 |
cfcmPortErrorsTable SEQUENCE OF CfcmPortErrorsEntry .1.3.6.1.4.1.9.10.999999.1.6 |
cfcmPortErrorsEntry CfcmPortErrorsEntry .1.3.6.1.4.1.9.10.999999.1.6.1 |
cfcmPortRxLinkResetsro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.1 |
cfcmPortTxLinkResetsro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.2 |
cfcmPortLinkResetsro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.3 |
cfcmPortRxOfflineSequencesro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.4 |
cfcmPortTxOfflineSequencesro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.5 |
cfcmPortLinkFailuresro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.6 |
cfcmPortLossofSynchsro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.7 |
cfcmPortLossofSignalsro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.8 |
cfcmPortPrimSeqProtocolErrorsro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.9 |
cfcmPortInvalidTxWordsro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.10 |
cfcmPortInvalidCRCsro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.11 |
cfcmPortInvalidOrderedSetsro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.12 |
cfcmPortFrameTooLongsro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.13 |
cfcmPortTruncatedFramesro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.14 |
cfcmPortAddressErrorsro Counter32 .1.3.6.1.4.1.9.10.999999.1.6.1.15 |
CISCO-FC-MGMT-MIB Technical Reference Overview
The CISCO-FC-MGMT-MIB SNMP MIB module published by Cisco defines 151 managed OID objects, including 127 scalar/column metrics, 10 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.10.999999. Key tabular structures include cfcmInstanceTable, cfcmSwitchTable, cfcmPortTable, cfcmPortStatsTable, cfcmPortLcStatsTable, cfcmPortErrorsTable.
Key OID Definitions in CISCO-FC-MGMT-MIB
.1.3.6.1.4.1.9.10.999999This module defines management information specific to Fibre Channel-attached devices. This module is an adaptation of IETF's IPS working group's draft, draft-ietf-ips-fcmgmt-mib-02
.1.3.6.1.4.1.9.10.999999.1.1Information about the local Fibre Channel management instances.
.1.3.6.1.4.1.9.10.999999.1.2A table of information about Fibre Channel switches which are managed by Fibre Channel management instances. Each Fibre Channel management instance can manage one or more Fibre Channel switches.
.1.3.6.1.4.1.9.10.999999.1.3Information about Fibre Channel ports. Each Fibre Channel port is represented by one entry in the IF-MIB's ifTable.
.1.3.6.1.4.1.9.10.999999.1.4A list of statistics for Fibre Channel ports.
.1.3.6.1.4.1.9.10.999999.1.5A list of Counter32-based statistics which are a shadow of the Counter64 statistics in the cfcmPortStatsTable, for systems which do not support Counter64.
.1.3.6.1.4.1.9.10.999999.1.6Error counters for Fibre Channel ports.
.1.3.6.1.4.1.9.10.999999.1.7Additional information about Fibre Channel ports which is specific to Fx_Ports. This table will contain one entry for each cfcmPortTable entry which represents an Fx_Port.
.1.3.6.1.4.1.9.10.999999.1.8Additional information about E_Ports, B_Ports, and any other type of Fibre Channel port to which inter-switch links can be connected. This table will contain one entry for each cfcmPortTable entry which represents such a port.
.1.3.6.1.4.1.9.10.999999.1.9A table that contains one entry for each Nx_Port logged- in/attached to a particular Fx_Port in the switch. Each entry contains the services parameters established during the most recent Fabric Login, explicit or implicit. Note that an Fx_Port may have one or more Nx_Ports attached to it.
.1.3.6.1.4.1.9.10.999999.1.10A table containing any Fibre Channel link information which is known to local Fibre Channel managed instances. One end of such a link is typically at a local port, but the table can also contain information on links for which neither end is a local port. If one end of a link terminates locally, then that end is termed 'end1'; the other end is termed 'end2'.
.1.3.6.1.4.1.9.10.999999.1.4.1An entry containing statistics for a Fibre Channel port.
.1.3.6.1.4.1.9.10.999999.1.4.1.1The number of transitions in/out of the buffer-to-buffer credit zero state. The other side is not providing any credit.
.1.3.6.1.4.1.9.10.999999.1.4.1.2The number of occurrences when all input buffers of a port were full and outbound buffer-to-buffer credit transitioned to zero, i.e., there became no credit to provide to other side.
.1.3.6.1.4.1.9.10.999999.1.4.1.3The number of Class 2 frames received at this port.
.1.3.6.1.4.1.9.10.999999.1.4.1.4The number of octets contained in Class 2 frames received at this port.
.1.3.6.1.4.1.9.10.999999.1.4.1.5The number of Class 2 frames transmitted out of this port.
.1.3.6.1.4.1.9.10.999999.1.4.1.6The number of octets contained in Class 2 frames transmitted out of this port.
.1.3.6.1.4.1.9.10.999999.1.4.1.7The number of Class 2 frames that were discarded upon reception at this port.
.1.3.6.1.4.1.9.10.999999.1.4.1.8The number of times that F_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when either the fabric or the destination port is temporarily busy. Note that this counter will never increment for an F_Port.
.1.3.6.1.4.1.9.10.999999.1.4.1.9The number of times that P_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when the destination port is temporarily busy.
.1.3.6.1.4.1.9.10.999999.1.4.1.10The number of times that F_RJT was returned to this port as a result of a Class 2 frame that was rejected by the fabric. Note that this counter will never increment for an F_Port.
.1.3.6.1.4.1.9.10.999999.1.4.1.11The number of times that P_RJT was returned to this port as a result of a Class 2 frame that was rejected at the destination N_Port.
.1.3.6.1.4.1.9.10.999999.1.4.1.12The number of times that F_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because either the Fabric or the destination port was temporarily busy. Note that this counter will never increment for an N_Port.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.