CISCO-FABRIC-MCAST-MIB
The CISCO-FABRIC-MCAST-MIB monitors and manages Fabric Multicast Group Identifier (FGID) states and associations with Logical Routers (LR) within Cisco Nexus data center fabrics to track multicast resource allocation and forwarding topology.
Imported Objects
Objects
24 total| Object Name |
|---|
ciscoFabricMcastMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.255 |
ciscoFabricMcastMIBNotifs OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.255.0 |
ciscoFabricMcastMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.255.1 |
cfmGeneral OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.255.1.1 |
cfmGenInfoTotalFgidsro Gauge32 UNITS "fgid" .1.3.6.1.4.1.9.9.255.1.1.1 |
cfmGenInfoInuseFgidsro Gauge32 UNITS "fgid" .1.3.6.1.4.1.9.9.255.1.1.2 |
cfmGenInfoHighWaterInuseFgidsro Gauge32 UNITS "fgid" .1.3.6.1.4.1.9.9.255.1.1.3 |
cfmPool OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.255.1.2 |
cfmPoolTable SEQUENCE OF CfmPoolEntry .1.3.6.1.4.1.9.9.255.1.2.1 |
cfmPoolEntry CfmPoolEntry .1.3.6.1.4.1.9.9.255.1.2.1.1 |
cfmPoolId CfmPoolIndex .1.3.6.1.4.1.9.9.255.1.2.1.1.1 |
cfmPoolNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.255.1.2.1.1.2 |
cfmPoolTypero Enumeration .1.3.6.1.4.1.9.9.255.1.2.1.1.3 |
cfmPoolTotalFgidsro Gauge32 UNITS "fgid" .1.3.6.1.4.1.9.9.255.1.2.1.1.4 |
cfmPoolInuseFgidsro Gauge32 UNITS "fgid" .1.3.6.1.4.1.9.9.255.1.2.1.1.5 |
cfmPoolHighWaterInuseFgidsro Gauge32 UNITS "fgid" .1.3.6.1.4.1.9.9.255.1.2.1.1.6 |
cfmLr OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.255.1.3 |
cfmLrTable SEQUENCE OF CfmLrEntry .1.3.6.1.4.1.9.9.255.1.3.1 |
cfmLrEntry CfmLrEntry .1.3.6.1.4.1.9.9.255.1.3.1.1 |
cfmLrInuseFgidsro Gauge32 UNITS "fgid" .1.3.6.1.4.1.9.9.255.1.3.1.1.1 |
cfmLrHighWaterInuseFgidsro Gauge32 UNITS "fgid" .1.3.6.1.4.1.9.9.255.1.3.1.1.2 |
ciscoFabricMcastMIBConform OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.255.2 |
cfmMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.255.2.1 |
cfmMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.255.2.2 |
CISCO-FABRIC-MCAST-MIB Technical Reference Overview
The CISCO-FABRIC-MCAST-MIB SNMP MIB module published by Cisco defines 24 managed OID objects, including 11 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.255. Key tabular structures include cfmPoolTable, cfmLrTable.
Key OID Definitions in CISCO-FABRIC-MCAST-MIB
.1.3.6.1.4.1.9.9.255Fabric Multicast Resource MIB module. This MIB module is used for managing/tracking the fabric multicast resource related information. Acronyms and terms: FGID - Fabric Multicast Group Identifier. LR - Logical router.
.1.3.6.1.4.1.9.9.255.1.2.1This table contains fabric multicast resource pool information.
.1.3.6.1.4.1.9.9.255.1.3.1This table contains fabric multicast resource information for a logical router.
.1.3.6.1.4.1.9.9.255.1.1.1The total number of FGIDs resource are detected in the managed system.
.1.3.6.1.4.1.9.9.255.1.1.2The current number of FGIDs that are currently in use by the managed system.
.1.3.6.1.4.1.9.9.255.1.1.3The highest number of FGIDs that was in use by all fabric multicast client applications in the managed system.
.1.3.6.1.4.1.9.9.255.1.2.1.1The information regarding a single fabric multicast resource pool. An entry of this table is created when a fabric multicast dedicated pool related client application is registered to fabric software or the first of fabric multicast shared pool related client application is registered to fabric software. An entry of this table is removed when the the last fabric multicast client application is unregistered from the pool.
.1.3.6.1.4.1.9.9.255.1.2.1.1.1An index that uniquely represents a fabric multicast resource pool. This index is assigned arbitrarily by the fabric software when fabric multicast application clients register for the use of fabric multicast resource.
.1.3.6.1.4.1.9.9.255.1.2.1.1.2The object to indicate FGID pool name.
.1.3.6.1.4.1.9.9.255.1.2.1.1.3The object to indicate FGID pool type. shared(1) - the pool is shared by multiple types of FGID clients. dedicated(2) - the pool is dedicated for a specific type of client to use. The dedicated pool is normally used by a critical client to prevent processes deadlock during system initialization or restart.
.1.3.6.1.4.1.9.9.255.1.2.1.1.4The total number of FGIDs in this pool. The total size might be dynamically adjusted based on the utilization of each pool or if a fabric multicast resource related entity is added or removed (e.g., add a new fabric rack or upgrade an old fabric rack to new fabric rack).
.1.3.6.1.4.1.9.9.255.1.2.1.1.5The current number of FGIDs in this pool that are currently in use by the FGID clients from one or more logical routers.
.1.3.6.1.4.1.9.9.255.1.2.1.1.6The highest number of FGIDs in this pool that was in use by the FGID clients from one or more logical routers.
.1.3.6.1.4.1.9.9.255.1.3.1.1The information regarding a single logical router that uses fabric multicast resource. An entry of this table is created when a logical router is created in the entLogicalTable of ENTITY-MIB and the logical router is registered for fabric multicast resource service. A logical router is identified by the value of mib-2 in entLogicalType object of ENTITY-MIB. An entry of this table is removed when the entry associated logical router is removed from entLogicalTable of ENTITY-MIB.
.1.3.6.1.4.1.9.9.255.1.3.1.1.1The current number of FGIDs that are currently in use by this logical router.
.1.3.6.1.4.1.9.9.255.1.3.1.1.2The highest number of FGIDs that was in use by this logical router.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.