CISCO-ENTITY-PFE-MIB
The CISCO-ENTITY-PFE-MIB monitors performance history and accumulated statistics for Cisco Network Processor-based Packet Forwarding Engines within the ENTITY-MIB physical table, tracking metrics across 1-minute, 5-minute, and 15-minute intervals. It provides up to 96 completed 15-minute intervals and rolling 24-hour totals to enable precise analysis of PFE pipeline throughput and resource utilization.
Imported Objects
Objects
49 total| Object Name |
|---|
ciscoEntityPfeMib MODULE-IDENTITY .1.3.6.1.4.1.9.9.265 |
cePfeMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.265.0 |
cePfeHistThldEvent NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.265.0.1 |
cePfeHistRestartEvent NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.265.0.2 |
cePfeMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.265.1 |
cePfePerformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.265.1.1 |
cePfePerfConfigTable SEQUENCE OF CePfePerfConfigEntry .1.3.6.1.4.1.9.9.265.1.1.1 |
cePfePerfConfigEntry CePfePerfConfigEntry .1.3.6.1.4.1.9.9.265.1.1.1.1 |
cePfePerfConfigTimeElapsedro Unsigned32 .1.3.6.1.4.1.9.9.265.1.1.1.1.1 |
cePfePerfConfigValidIntervalsro Unsigned32 .1.3.6.1.4.1.9.9.265.1.1.1.1.2 |
cePfePerfConfigThldUtilizationrw Percentage .1.3.6.1.4.1.9.9.265.1.1.1.1.3 |
cePfePerfConfigThldEfficiencyrw Percentage .1.3.6.1.4.1.9.9.265.1.1.1.1.4 |
cePfePerfConfigThld1MinUtilizationrw Percentage .1.3.6.1.4.1.9.9.265.1.1.1.1.5 |
cePfePerfConfigThld1MinEfficiencyrw Percentage .1.3.6.1.4.1.9.9.265.1.1.1.1.6 |
cePfePerfConfigThld5MinUtilizationrw Percentage .1.3.6.1.4.1.9.9.265.1.1.1.1.7 |
cePfePerfConfigThld5MinEfficiencyrw Percentage .1.3.6.1.4.1.9.9.265.1.1.1.1.8 |
cePfePerfCurrentTable SEQUENCE OF CePfePerfCurrentEntry .1.3.6.1.4.1.9.9.265.1.1.2 |
cePfePerfCurrentEntry CePfePerfCurrentEntry .1.3.6.1.4.1.9.9.265.1.1.2.1 |
cePfePerfCurrentUtilizationro CurrentUtilization .1.3.6.1.4.1.9.9.265.1.1.2.1.1 |
cePfePerfCurrentEfficiencyro CurrentEfficiency .1.3.6.1.4.1.9.9.265.1.1.2.1.2 |
cePfePerfCurrent1MinUtilizationro CurrentUtilization .1.3.6.1.4.1.9.9.265.1.1.2.1.3 |
cePfePerfCurrent1MinEfficiencyro CurrentEfficiency .1.3.6.1.4.1.9.9.265.1.1.2.1.4 |
cePfePerfCurrent5MinUtilizationro CurrentUtilization .1.3.6.1.4.1.9.9.265.1.1.2.1.5 |
cePfePerfCurrent5MinEfficiencyro CurrentEfficiency .1.3.6.1.4.1.9.9.265.1.1.2.1.6 |
cePfePerfIntervalTable SEQUENCE OF CePfePerfIntervalEntry .1.3.6.1.4.1.9.9.265.1.1.3 |
cePfePerfIntervalEntry CePfePerfIntervalEntry .1.3.6.1.4.1.9.9.265.1.1.3.1 |
cePfePerfIntervalNumber Unsigned32 .1.3.6.1.4.1.9.9.265.1.1.3.1.1 |
cePfePerfIntervalUtilizationro IntervalUtilization .1.3.6.1.4.1.9.9.265.1.1.3.1.2 |
cePfePerfIntervalEfficiencyro IntervalEfficiency .1.3.6.1.4.1.9.9.265.1.1.3.1.3 |
cePfePerfTotalTable SEQUENCE OF CePfePerfTotalEntry .1.3.6.1.4.1.9.9.265.1.1.4 |
cePfePerfTotalEntry CePfePerfTotalEntry .1.3.6.1.4.1.9.9.265.1.1.4.1 |
cePfePerfTotalUtilizationro TotalUtilization .1.3.6.1.4.1.9.9.265.1.1.4.1.1 |
cePfePerfTotalEfficiencyro TotalEfficiency .1.3.6.1.4.1.9.9.265.1.1.4.1.2 |
cePfeHistory OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.265.1.2 |
cePfeHistNotifiesEnablerw EventType .1.3.6.1.4.1.9.9.265.1.2.1 |
cePfeHistTableSizerw Unsigned32 .1.3.6.1.4.1.9.9.265.1.2.2 |
cePfeHistTableLastIndexro Unsigned32 .1.3.6.1.4.1.9.9.265.1.2.3 |
cePfeHistTable SEQUENCE OF CePfeHistEntry .1.3.6.1.4.1.9.9.265.1.2.4 |
cePfeHistEntry CePfeHistEntry .1.3.6.1.4.1.9.9.265.1.2.4.1 |
cePfeHistIndex Unsigned32 .1.3.6.1.4.1.9.9.265.1.2.4.1.1 |
cePfeHistEntPhysIndexro PhysicalIndex (ENTITY-MIB) .1.3.6.1.4.1.9.9.265.1.2.4.1.2 |
cePfeHistTypero HistEventType .1.3.6.1.4.1.9.9.265.1.2.4.1.3 |
cePfeHistThldro Percentage .1.3.6.1.4.1.9.9.265.1.2.4.1.4 |
cePfeHistValuero Percentage .1.3.6.1.4.1.9.9.265.1.2.4.1.5 |
cePfeHistRestartReasonro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.9.265.1.2.4.1.6 |
cePfeHistTimeStampro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.9.9.265.1.2.4.1.7 |
cePfeMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.265.2 |
cePfeMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.265.2.1 |
cePfeMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.265.2.2 |
CISCO-ENTITY-PFE-MIB Technical Reference Overview
The CISCO-ENTITY-PFE-MIB SNMP MIB module published by Cisco defines 49 managed OID objects, including 30 scalar/column metrics, 5 SNMP tables, and 2 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.265. Key tabular structures include cePfePerfConfigTable, cePfePerfCurrentTable, cePfePerfIntervalTable, cePfePerfTotalTable, cePfeHistTable. Monitored SNMP traps/notifications include cePfeHistThldEvent, cePfeHistRestartEvent.
Key OID Definitions in CISCO-ENTITY-PFE-MIB
.1.3.6.1.4.1.9.9.265The Packet Forwarding Engine technology are Cisco developed Network Processors, which accelerates certain features in order to provide better network performance. An agent uses this MIB to monitor the performance history on any active PFE pipeline listed in the ENTITY-MIB (RFC 2737) entPhysicalTable. This monitoring is via measurement periods of actual, 1-minute, 5-minutes and 15-minutes. For the 1-minute and 5-minute measurement periods, perfor- mance statistics are calculated and displayed based on pre- vious 1 minute and 5 minute respectively. For the 15-minute period, the performance statistics are accumulated in fifteen minute intervals. At any one time, an agent maintains one current (incomplete) interval and up to 96 completed intervals (24 hours worth). Fewer than 96 intervals of data will be available if the agent has been restarted within the last 24 hours. In addition, there is a rolling 24-hour total of each performance statistic. There is no requirement for an agent to ensure fixed rela- tionship between the start of a fifteen minute interval and any wall clock; however some agents may align the fifteen minute intervals with quarter hours.
.1.3.6.1.4.1.9.9.265.1.1.1This table contains configuration information on a PFE pipeline.
.1.3.6.1.4.1.9.9.265.1.1.2This table maintains PFE current running performance, which are collected at various measurement periods.
.1.3.6.1.4.1.9.9.265.1.1.3This table contains performance statistics for completed 15 minutes intervals, specifically up to 96 such intervals over a 24 hours of operation.
.1.3.6.1.4.1.9.9.265.1.1.4This table contains the running utilization and efficiency of the PFE pipeline for the 24 hour period preceding the current interval. If the agent was restarted less than 24 hours ago, i.e., when there are less than 96 intervals in the cePfePerfIntervalTable, it will contain the running utiliza- tion and efficiency up to the last collected 15 minute inter- val.
.1.3.6.1.4.1.9.9.265.1.2.4This table contains a history of events generated by the agent.
.1.3.6.1.4.1.9.9.265.0.1This notification is generated when a threshold event has occurred and the cePfeHistNotifiesEnable is set to 'notify (3)' or 'logAndNotify(4)'. After generating this notification, another such notifica- tion will not be sent out until the sample value has fallen below the threshold value.
.1.3.6.1.4.1.9.9.265.0.2This notification is generated when a restart event has occurred and the cePfeHistNotifiesEnable is set to 'notifyp (3)' or 'logAndNotify(4)'.
.1.3.6.1.4.1.9.9.265.1.1.2.1An entry containing performance information applicable to a particular PFE pipeline.
.1.3.6.1.4.1.9.9.265.1.1.2.1.1This object provides the actual PFE percentage utilization. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline.
.1.3.6.1.4.1.9.9.265.1.1.2.1.2This object provides the actual PFE percentage efficiency. It is determined by the total number of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero.
.1.3.6.1.4.1.9.9.265.1.1.2.1.3This object provides the PFE percentage utilization over the previous 1 minute period. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline.
.1.3.6.1.4.1.9.9.265.1.1.2.1.4This object provides the PFE percentage efficiency over the previous 1 minute period. It is determined by the totalnumber of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero.
.1.3.6.1.4.1.9.9.265.1.1.2.1.5This object provides the PFE percentage utilization over the previous 5 minutes period. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline.
.1.3.6.1.4.1.9.9.265.1.1.2.1.6This object provides the PFE percentage efficiency over the previous 5 minutes period. It is determined by the total number of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero.
.1.3.6.1.4.1.9.9.265.1.2.1This object indicates what type of action should be taken by the agent when a event is generated.
.1.3.6.1.4.1.9.9.265.1.2.2This object specifies the number of entries that the cePfeHistTable can contain. When a event is generated, and the capacity of the cePfeHistTable has reached the value specified by this object, then the agent deletes the oldest entity in order to accommodate the new entry. A value of '0' prevents any history from being retained.
.1.3.6.1.4.1.9.9.265.1.2.3This object specifies the value of the cePfeHistIndex object corresponding to the last entry added to the table by the agent. It will return zero if there are no entries in the table. If the management client uses the notifications defined by this module, then it can poll this object to determine whether it has missed a notification sent by the agent.
.1.3.6.1.4.1.9.9.265.1.1.1.1An entry will exist for each entry in the entPhysicalTable that correspond to an active PFE pipeline.
.1.3.6.1.4.1.9.9.265.1.1.1.1.1The number of seconds that have elapsed since the beginning of the current 15 min interval. If for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value.
.1.3.6.1.4.1.9.9.265.1.1.1.1.2The number of completed 15 min intervals for which valid PFE performance data has been collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of completed 15 minute intervals since the PFE pipeline has been online.
.1.3.6.1.4.1.9.9.265.1.1.1.1.3This object contains the threshold value for the cePfePerfCurrentUtilization object. If during the last 5 second measurement period the cePfePerfCurrentUtilization object becomes greater than or equal to this threshold value, an event of type 'thldUtilizationEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrentUtilization object value and the threshold value, therefore no event action will be gene- rated.
.1.3.6.1.4.1.9.9.265.1.1.1.1.4This object contains the threshold value for the cePfePerfCurrentEffciency object. If during the last 5 second measurement period the cePfePerfCurrentEfficiency object becomes less than or equal to this threshold value, an event of type 'thldEfficiencyEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrentEfficiency object value and the threshold value, therefore no event action will be gene- rated.
.1.3.6.1.4.1.9.9.265.1.1.1.1.5This object contains the threshold value for the cePfePerfCurrent1MinUtilization object. If during the last 1 minute measurement period the cePfePerfCurrent1MinUtilization object becomes greater than or equal to this threshold value, an event of type 'thld1MinUtilizationEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrent1MinUtilization object value and the threshold value, therefore no event action will be gene- rated.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.