CISCO-DSL-PROVISION-MIB
The CISCO-DSL-PROVISION-MIB manages Cisco DSL access servers to configure and monitor PPP over ATM subscriber sessions, specifically handling the provisioning parameters required to establish and maintain broadband connectivity. Key operational elements include the creation of logical DSL interfaces, the assignment of ATM virtual circuits, and the management of session states for individual subscriber lines.
Imported Objects
Objects
71 total| Object Name |
|---|
ciscoDslProvisionMIB MODULE-IDENTITY .1.3.6.1.4.1.9.10.30 |
ciscoDslProvMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.30.1 |
cdslNrpSlot OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.30.1.1 |
cdslMaxNrpsro Unsigned32 .1.3.6.1.4.1.9.10.30.1.1.1 |
cdslNrpNumberro Gauge32 .1.3.6.1.4.1.9.10.30.1.1.2 |
cdslNrpIpAddressTable SEQUENCE OF CdslNrpIpAddressEntry .1.3.6.1.4.1.9.10.30.1.1.3 |
cdslNrpIpAddressEntry CdslNrpIpAddressEntry .1.3.6.1.4.1.9.10.30.1.1.3.1 |
cdslNrpSlotIndex Integer32 .1.3.6.1.4.1.9.10.30.1.1.3.1.1 |
cdslNrpIpAddressro IpAddress .1.3.6.1.4.1.9.10.30.1.1.3.1.2 |
cdslVirtualTemplate OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.30.1.2 |
cdslVirtualTemplateNumberTable SEQUENCE OF CdslVirtualTemplateNumberEntry .1.3.6.1.4.1.9.10.30.1.2.1 |
cdslVirtualTemplateNumberEntry CdslVirtualTemplateNumberEntry .1.3.6.1.4.1.9.10.30.1.2.1.1 |
cdslMaxVirtualTemplatesro Unsigned32 .1.3.6.1.4.1.9.10.30.1.2.1.1.1 |
cdslVirtualTemplatesro Gauge32 .1.3.6.1.4.1.9.10.30.1.2.1.1.2 |
cdslVirtualTemplateTable SEQUENCE OF CdslVirtualTemplateEntry .1.3.6.1.4.1.9.10.30.1.2.2 |
cdslVirtualTemplateEntry CdslVirtualTemplateEntry .1.3.6.1.4.1.9.10.30.1.2.2.1 |
cdslVTIndex Integer32 .1.3.6.1.4.1.9.10.30.1.2.2.1.1 |
cdslVTIpAddressMethodrw Enumeration .1.3.6.1.4.1.9.10.30.1.2.2.1.2 |
cdslVTIpAddressrw IpAddress .1.3.6.1.4.1.9.10.30.1.2.2.1.3 |
cdslVTIpAddressMaskrw IpAddress .1.3.6.1.4.1.9.10.30.1.2.2.1.4 |
cdslVTIpIfIndexrw InterfaceIndexOrZero (IF-MIB) .1.3.6.1.4.1.9.10.30.1.2.2.1.5 |
cdslVTPeerIpAddressMethodrw Enumeration .1.3.6.1.4.1.9.10.30.1.2.2.1.6 |
cdslVTPeerIpAddrPoolrw DisplayString .1.3.6.1.4.1.9.10.30.1.2.2.1.7 |
cdslVTPppAuthChaprw Integer32 .1.3.6.1.4.1.9.10.30.1.2.2.1.8 |
cdslVTPppAuthMSChaprw Integer32 .1.3.6.1.4.1.9.10.30.1.2.2.1.9 |
cdslVTPppAuthPaprw Integer32 .1.3.6.1.4.1.9.10.30.1.2.2.1.10 |
cdslVTPppChapHostrw DisplayString .1.3.6.1.4.1.9.10.30.1.2.2.1.11 |
cdslVTPppChapPasswordrw DisplayString .1.3.6.1.4.1.9.10.30.1.2.2.1.12 |
cdslVTPppChapEncrypTyperw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.10.30.1.2.2.1.13 |
cdslVTPppChapRefuserw Enumeration .1.3.6.1.4.1.9.10.30.1.2.2.1.14 |
cdslVTPppChapWaitPeerrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.10.30.1.2.2.1.15 |
cdslVTPppPapUserNamerw DisplayString .1.3.6.1.4.1.9.10.30.1.2.2.1.16 |
cdslVTPppPapPasswordrw DisplayString .1.3.6.1.4.1.9.10.30.1.2.2.1.17 |
cdslVTPppPapEncrypTyperw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.10.30.1.2.2.1.18 |
cdslVTPppUseTacacsrw Enumeration .1.3.6.1.4.1.9.10.30.1.2.2.1.19 |
cdslVTRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.10.30.1.2.2.1.20 |
cdslLocalIpAddrPool OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.30.1.3 |
cdslLocalIpAddrPoolNumberTable SEQUENCE OF CdslLocalIpAddrPoolNumberEntry .1.3.6.1.4.1.9.10.30.1.3.1 |
cdslLocalIpAddrPoolNumberEntry CdslLocalIpAddrPoolNumberEntry .1.3.6.1.4.1.9.10.30.1.3.1.1 |
cdslMaxLocalIpAddrPoolsro Unsigned32 .1.3.6.1.4.1.9.10.30.1.3.1.1.1 |
cdslLocalIpAddrPoolsro Gauge32 .1.3.6.1.4.1.9.10.30.1.3.1.1.2 |
cdslLocalIpAddrPoolTable SEQUENCE OF CdslLocalIpAddrPoolEntry .1.3.6.1.4.1.9.10.30.1.3.2 |
cdslLocalIpAddrPoolEntry CdslLocalIpAddrPoolEntry .1.3.6.1.4.1.9.10.30.1.3.2.1 |
cdslLocalIpAddrPoolName DisplayString .1.3.6.1.4.1.9.10.30.1.3.2.1.1 |
cdslLocalIpAddrPoolFreeAddressesro Unsigned32 .1.3.6.1.4.1.9.10.30.1.3.2.1.2 |
cdslLocalIpAddrPoolInUseAddressesro Unsigned32 .1.3.6.1.4.1.9.10.30.1.3.2.1.3 |
cdslLocalIpAddrRangeTable SEQUENCE OF CdslLocalIpAddrRangeEntry .1.3.6.1.4.1.9.10.30.1.3.3 |
cdslLocalIpAddrRangeEntry CdslLocalIpAddrRangeEntry .1.3.6.1.4.1.9.10.30.1.3.3.1 |
cdslLocalIpAddrRangeLowAddr IpAddress .1.3.6.1.4.1.9.10.30.1.3.3.1.1 |
cdslLocalIpAddrRangeHighAddr IpAddress .1.3.6.1.4.1.9.10.30.1.3.3.1.2 |
cdslLocalIpAddrRangeRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.10.30.1.3.3.1.3 |
cdslAtmPvc OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.30.1.4 |
cdslPppOverAtmPvcNumberTable SEQUENCE OF CdslPppOverAtmPvcNumberEntry .1.3.6.1.4.1.9.10.30.1.4.1 |
cdslPppOverAtmPvcNumberEntry CdslPppOverAtmPvcNumberEntry .1.3.6.1.4.1.9.10.30.1.4.1.1 |
cdslPppOverAtmPvcsro Gauge32 .1.3.6.1.4.1.9.10.30.1.4.1.1.1 |
cdslAtmPvcTable SEQUENCE OF CdslAtmPvcEntry .1.3.6.1.4.1.9.10.30.1.4.2 |
cdslAtmPvcEntry CdslAtmPvcEntry .1.3.6.1.4.1.9.10.30.1.4.2.1 |
cdslAtmPvcVpi Integer32 .1.3.6.1.4.1.9.10.30.1.4.2.1.1 |
cdslAtmPvcVci Integer32 .1.3.6.1.4.1.9.10.30.1.4.2.1.2 |
cdslAtmPvcNamerw DisplayString .1.3.6.1.4.1.9.10.30.1.4.2.1.3 |
cdslAtmPvcSubIfNumberrw Integer32 .1.3.6.1.4.1.9.10.30.1.4.2.1.4 |
cdslAtmPvcClassrw DisplayString .1.3.6.1.4.1.9.10.30.1.4.2.1.5 |
cdslAtmPvcQosTypero Enumeration .1.3.6.1.4.1.9.10.30.1.4.2.1.6 |
cdslAtmPvcAbrPCRro Unsigned32 .1.3.6.1.4.1.9.10.30.1.4.2.1.7 |
cdslAtmPvcAbrMCRro Unsigned32 .1.3.6.1.4.1.9.10.30.1.4.2.1.8 |
cdslAtmPvcAbrIORIFro Unsigned32 .1.3.6.1.4.1.9.10.30.1.4.2.1.9 |
cdslAtmPvcAbrIORDFro Unsigned32 .1.3.6.1.4.1.9.10.30.1.4.2.1.10 |
cdslAtmPvcBroadcastro Enumeration .1.3.6.1.4.1.9.10.30.1.4.2.1.11 |
cdslAtmPvcEncapsulationro Enumeration .1.3.6.1.4.1.9.10.30.1.4.2.1.12 |
cdslVcClass OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.30.1.5 |
cdslAtmPvcMuxLinkTyperw Enumeration .ciscoDslProvMIBGroups.5 |
CISCO-DSL-PROVISION-MIB Technical Reference Overview
The CISCO-DSL-PROVISION-MIB SNMP MIB module published by Cisco defines 71 managed OID objects, including 48 scalar/column metrics, 8 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.10.30. Key tabular structures include cdslNrpIpAddressTable, cdslVirtualTemplateNumberTable, cdslVirtualTemplateTable, cdslLocalIpAddrPoolNumberTable, cdslLocalIpAddrPoolTable, cdslLocalIpAddrRangeTable.
Key OID Definitions in CISCO-DSL-PROVISION-MIB
.1.3.6.1.4.1.9.10.30Cisco DSL (Digital Subscriber Line) Provision MIB Module. It is used to create subscriber PPP over ATM sessions and related tasks.
.1.3.6.1.4.1.9.10.30.1.1.3This table reflects the IP addresses of each NRP in the system.
.1.3.6.1.4.1.9.10.30.1.2.1This table reflects the number of virtual template that are presently set up in each NRP. A virtual template interface is a logical entity a configuration for a serial-interface but not tied to a physical interface - thatcan be applied dynamically as needed.
.1.3.6.1.4.1.9.10.30.1.2.2This table includes the virtual templates in the NRP identified by cNrpSlotIndex. Though a virtual template is often called a virtual template interface, it is not reflected in the ifTable.
.1.3.6.1.4.1.9.10.30.1.3.1This table indicates the number of IP address pools that are presently set up in each NRP.
.1.3.6.1.4.1.9.10.30.1.3.2This table defines the IP local address pool. An IP address pool may have a single entry in the table. The ranges of a pool are represented in the cdslLocalIPAddrRangeTable.
.1.3.6.1.4.1.9.10.30.1.3.3This table defines the IP local address pool ranges. An IP address pool may have a single entry or multiple entries in the table, since an IP address pool can have multiple dis-continuous ranges. Each range will have a separate entry in the table.
.1.3.6.1.4.1.9.10.30.1.4.1This table reflects the number of PVCs of PPP encapsulation presently set up in each NRP.
.1.3.6.1.4.1.9.10.30.1.4.2This table includes configuration parameters for ATM PVCs with PPP encapsulation. The vc-mode ATM PVC management approach is used as the PVC creating method, which greatly simplifies configuration by using of vc-class. The PVCs which were created using atm pvc cli commands can only be read or deleted from snmp. In case of reading, only the values of vpi, vci, sub-interface number, encapsulation, virtual template number and row status are meaningful. When trying to set any object of these PVCs, a GEN_ERROR returns except for the row status object. To indicate a PVC is created with old pvc syntax, the value of cdslAtmPvcClass will be set into '!'.
.1.3.6.1.4.1.9.10.30.1.1.1Maximum number of the node routing processors (NRP) allowed in the system.
.1.3.6.1.4.1.9.10.30.1.1.2The number of NRPs that are present in this system.
.ciscoDslProvMIBGroups.5This object can be used to This object is used to specify the link type if the encapsulation is aal5mux. 1 2 DEFVAL { ppp } ::= { cdslAtmPvcEntry 13 } cdslAtmPvcVirtualTemplate OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION
.1.3.6.1.4.1.9.10.30.1.1.3.1These entries are used to store the IP Addresses of NRP cards that are inserted in the indexed slot. The IP addresses are used to access these cards.
.1.3.6.1.4.1.9.10.30.1.1.3.1.1The object specifies the identifier of a slot containing a NRP.
.1.3.6.1.4.1.9.10.30.1.1.3.1.2The object specifies the IP addresses associated with the NRP contained in the slot identified by cdslNrpSlotIndex.
.1.3.6.1.4.1.9.10.30.1.2.1.1Entries are read only.
.1.3.6.1.4.1.9.10.30.1.2.1.1.1The object specifies the maximum number of virtual templates allowed in one single NRP.
.1.3.6.1.4.1.9.10.30.1.2.1.1.2This object indicates the number of virtual templates presently set up in each NRP identified by cdslNrpSlotIndex.
.1.3.6.1.4.1.9.10.30.1.2.2.1User may create a new entry or delete an existing entry. Entries may be created without explicitly setting cdslVTRowStatus. While the row status is 'active', objects having read-create access can be changed.
.1.3.6.1.4.1.9.10.30.1.2.2.1.1This object represents an arbitrary index used to identify the virtual template entry.
.1.3.6.1.4.1.9.10.30.1.2.2.1.2This object indicates how an IP address is obtained to be associated with this virtual template. The actual parameters of these methods are indicated by the objects defined after. none ipAddress interfaceIp if it has one. negotiate DHCP server. In the set operation, only the parameter corresponding to this object is considered. All other parameters are ignored and forgotten.
.1.3.6.1.4.1.9.10.30.1.2.2.1.3This object specifies the IP address associated with this virtual template entry. This object is only valid when cdslVTIpAddressMethod is 'ipAddress'. To set the value correctly, this object shall be set in the same packet as cdslVTIpAddressMethod.
.1.3.6.1.4.1.9.10.30.1.2.2.1.4This object specifies the IP address mask. This object is only valid when cdslVTIpAddressMethod is 'ipAddress'. To set the value correctly, this object shall be set in the same packet as cdslVTIpAddressMethod.
.1.3.6.1.4.1.9.10.30.1.2.2.1.5This object specifies the ifIndex of the interface, whose IP address will be used for the virtual template entry. Any interface with an IP address in the routing processor can be selected. This object is only valid when cdslVTIpAddressMethod is 'interfaceIp'. To set the value correctly, this object shall be set in the same packet as cdslVTIpAddressMethod.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.