CISCO-DS0-CROSS-CONNECT-MIB
The CISCO-DS0-CROSS-CONNECT-MIB monitors and manages DS0 time-division multiplexing cross-connection states and configurations on Cisco voice gateways and routers. It provides visibility into specific DS0 channel bindings, connection status, and circuit integrity for T1/E1 digital signal interfaces.
Imported Objects
Objects
14 total| Object Name |
|---|
ciscoDs0CrossConnectMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.9999 |
ciscoDs0CrossConnectMIBNotifs OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.9999.0 |
ciscoDs0CrossConnectMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.9999.1 |
cDs0CrossConnectConfig OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.9999.1.1 |
cds0CrossConnectConfigTable SEQUENCE OF Cds0CrossConnectConfigEntry .1.3.6.1.4.1.9.9.9999.1.1.1 |
cds0CrossConnectConfigEntry Cds0CrossConnectConfigEntry .1.3.6.1.4.1.9.9.9999.1.1.1.1 |
cds0Endpt1Ds1 InterfaceIndex (IF-MIB) .1.3.6.1.4.1.9.9.9999.1.1.1.1.1 |
cds0Endpt1Ds0Group Unsigned32 .1.3.6.1.4.1.9.9.9999.1.1.1.1.2 |
cds0Endpt2Ds1rw InterfaceIndex (IF-MIB) .1.3.6.1.4.1.9.9.9999.1.1.1.1.3 |
cds0Endpt2Ds0Grouprw Unsigned32 .1.3.6.1.4.1.9.9.9999.1.1.1.1.4 |
cds0ConnRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.9999.1.1.1.1.5 |
ciscoDs0CrossConnectMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.9999.2 |
ciscoDs0CrossConnectMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.9999.2.1 |
ciscoDs0CrossConnectMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.9999.2.2 |
CISCO-DS0-CROSS-CONNECT-MIB Technical Reference Overview
The CISCO-DS0-CROSS-CONNECT-MIB SNMP MIB module published by Cisco defines 14 managed OID objects, including 5 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.9999. Key tabular structures include cds0CrossConnectConfigTable.
Key OID Definitions in CISCO-DS0-CROSS-CONNECT-MIB
.1.3.6.1.4.1.9.9.9999The MIB for Ds0 cross connection.
.1.3.6.1.4.1.9.9.9999.1.1.1This table is used to establish a DS0 cross connection. A DS0 cross connect is established by binding a unique DS0 group containing one or more DS0s of a single Ds1 interface to another unique DS0 group containing one or more DS0s of a single DS1 interface.
.1.3.6.1.4.1.9.9.9999.1.1.1.1An entry in cds0CrossConnectConfigTable table represents a DS0 cross connection. The two end point of the connection are: end point 1: cds0Endpt1Ds1 cds0Endpt1Ds0Group end point 2: cds0Endpt2Ds1 cds0Endpt2Ds0Group The end points of this connection should be entries of ccasGrpCfgTable and 'ccasGrpCfgServiceType' of of the entries should be 'tdmxconn'. The ccasGrpCfgTable is defined in CISCO-CAS-IF-MIB.
.1.3.6.1.4.1.9.9.9999.1.1.1.1.1The value of this object equals to the 'ifIndex' of a Ds1 interface. This Ds1 interface is used as the first end point of the Ds0 connection.
.1.3.6.1.4.1.9.9.9999.1.1.1.1.2The value of this object identifies a Ds0 group which contains one of more Ds0(s) within the Ds1 interface represented by 'cDs0Endpt1Ds1'. This Ds0 group is used as the first end point of the Ds0 connection.
.1.3.6.1.4.1.9.9.9999.1.1.1.1.3The value of this object equals to the 'ifIndex' of a Ds1 interface. This Ds1 interface is used as the second end point of the Ds0 connection.
.1.3.6.1.4.1.9.9.9999.1.1.1.1.4The value of this object identifies a Ds0 group which contains one of more Ds0(s) within the Ds1 interface represented by 'cDs0Endpt2Ds1'. This Ds0 group is used as the second end point of the Ds0 connection.
.1.3.6.1.4.1.9.9.9999.1.1.1.1.5This object is used to create or delete an entry. The mandatory objects for creating an entry in this table: 'cds0Endpt2Ds1' 'cds0Endpt2Ds0Group' The following objects are not allowed to be modified after the entry to be added: 'cds0Endpt2Ds1' 'cds0Endpt2Ds0Group'
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.