Home/Catalog/CISCO-DOCS-REMOTE-QUERY-MIB

CISCO-DOCS-REMOTE-QUERY-MIB

AI MIB Summary

The CISCO-DOCS-REMOTE-QUERY-MIB configures and monitors the CMTS CM Poller service on Cisco Cable Modem Termination Systems to facilitate SNMP polling of remote cable modems. It exposes configuration parameters and operational status objects for both the polling engine and the specific remote cable modems targeted by the poller.

This MIB module provides the management of the Cisco Cable Modem Termination Systems (CMTS) Remote Query feature. This feature, implemented on a CMTS, facilitates SNMP polling of remote cable modems (CMs). This MIB includes the configuration and status objects of the CMTS CM Poller and remote CMs that polled by the CMTS CM Poller
29
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

29 total
Object Name
ciscoDocsRemoteQueryMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.10.59
CISCO-DOCS-EXT-MIB
Unknown
.1.3.6.1.4.1.9.10.59
ciscoDocsRemQueryMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.10.59.1
cdrqPoller
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.10.59.1.1
cdrqCmtsCmPollerEnablerw
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.9.10.59.1.1.1
cdrqCmtsCmPollerIntervalrw
TimeInterval
.1.3.6.1.4.1.9.10.59.1.1.2
cdrqCmtsCmPollerCommunityrw
OCTET STRING
.1.3.6.1.4.1.9.10.59.1.1.3
cdrqCmtsCmPollerContextEngineIDrw
SnmpEngineID -- Rsyntax OCTET STRING
.1.3.6.1.4.1.9.10.59.1.1.4
cdrqCmtsCmPollerContextNamerw
SnmpAdminString
.1.3.6.1.4.1.9.10.59.1.1.5
cdrqCmtsCmPollerStartTimero
TimeStamp -- Rsyntax TimeTicks
.1.3.6.1.4.1.9.10.59.1.1.6
cdrqCmtsCmPollerStopTimero
TimeStamp -- Rsyntax TimeTicks
.1.3.6.1.4.1.9.10.59.1.1.7
cdrqCM
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.10.59.1.2
cdrqCmtsCmStatusTable
SEQUENCE OF CdrqCmtsCmStatusEntry
.1.3.6.1.4.1.9.10.59.1.2.1
cdrqCmtsCmStatusEntry
CdrqCmtsCmStatusEntry
.1.3.6.1.4.1.9.10.59.1.2.1.1
cdrqCmtsCmDownChannelPowerro
TenthdBmV -- Rsyntax INTEGER -- Units -- dBmV
.1.3.6.1.4.1.9.10.59.1.2.1.1.1
cdrqCmtsCmStatusTxPowerro
TenthdBmV -- Rsyntax INTEGER -- Units -- dBmV
.1.3.6.1.4.1.9.10.59.1.2.1.1.2
cdrqCmtsCmUpChnlTxTimingOffsetro
Gauge
.1.3.6.1.4.1.9.10.59.1.2.1.1.3
cdrqCmtsCmSigQSignalNoisero
TenthdB -- Rsyntax INTEGER -- Units -- dB
.1.3.6.1.4.1.9.10.59.1.2.1.1.4
cdrqCmtsCmSigQMicroreflectionsro
INTEGER
.1.3.6.1.4.1.9.10.59.1.2.1.1.5
cdrqCmtsCmPollTimero
TimeStamp -- Rsyntax TimeTicks
.1.3.6.1.4.1.9.10.59.1.2.1.1.6
ciscoDocsRQNotificationsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.10.59.2
ciscoDocsRQNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.10.59.2.0
cdrqCmtsCmRQDoneNotification
TRAP-TYPE
.1.3.6.1.4.1.9.10.59.2.0.1
ciscoDocsRemoteQueryConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.10.59.3
cdrqDocsRemoteQueryCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.10.59.3.1
cdrqDocsRemoteQueryCompliance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.10.59.3.1.1
cdrqDocsRemoteQueryGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.10.59.3.2
cdrqPollerGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.10.59.3.2.1
cdrqCMGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.10.59.3.2.2

CISCO-DOCS-REMOTE-QUERY-MIB Technical Reference Overview

The CISCO-DOCS-REMOTE-QUERY-MIB SNMP MIB module published by Cisco defines 29 managed OID objects, including 14 scalar/column metrics, 1 SNMP tables, and 1 trap/notification events. Key tabular structures include cdrqCmtsCmStatusTable. Monitored SNMP traps/notifications include cdrqCmtsCmRQDoneNotification.

Key OID Definitions in CISCO-DOCS-REMOTE-QUERY-MIB

cdrqCmtsCmStatusTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.10.59.1.2.1

This table contains the status of the cable modems that are polled by the CMTS CM Poller. The information will be overwritten when a new polling cycle starts. The removal of CM from the list or adding a new CM to the list won't be reflected until the next polling cycle. Depending on how many CMs that the poller is polling, polling this table constantly can be quite expensive; Therefore, it is best to poll upon receipt of the cdrqCmtsCmRQDoneNotification. As a hedge against lost notifications, periodic background polling should be performed. Howerver, excessive polling could degrade performance.

cdrqCmtsCmRQDoneNotificationTRAP-TYPEnot-accessible
.1.3.6.1.4.1.9.10.59.2.0.1

This notification is sent when CMTS CM Poller finished polling for the current cycle. The cdrqCmtsCmPollerStartTime is the time when the polling cycle started. The cdrqCmtsCmPollerStopTime is the time when the polling cycle finished.

cdrqCmtsCmPollerEnableTruthValueread-write
.1.3.6.1.4.1.9.10.59.1.1.1

An indication of whether the CMTS CM Poller is running. When the poller is enabled, it polls the remote CMs periodically specified in the cdrqCmtsCmPollerInterval mib object. The operation can be expensive depending on how many CMs that the poller would be polling. It is suggested to have it disabled when not needed.

cdrqCmtsCmPollerIntervalTimeInterval(1..8640000)read-write
.1.3.6.1.4.1.9.10.59.1.1.2

An interval between two polling cycles of the CMTS CM Poller. The poller will not start the next cycle until it finished polling for the last CM , even though the time has expired. If the cdrqCmtsCmPollerInterval is too small with a large number of CMs, the poller would tie up the CPU and resources and possibly degrade the system's performance. Any change in the cdrqCmtsCmPollerInterval will not be reflected if the poller has already been enabled.

cdrqCmtsCmPollerCommunityOCTETread-write
.1.3.6.1.4.1.9.10.59.1.1.3

The read community string is used for polling the CMs. Any change in the cdrqCmtsCmPollerCommunity will not be reflected if the poller has already been enabled. For SNMPv3, this object will contain a user name instead of a community string.

cdrqCmtsCmPollerContextEngineIDSnmpEngineIDread-write
.1.3.6.1.4.1.9.10.59.1.1.4

The contextEngineID indicating the location of the context in which management information is accessed when using the user name specified by the corresponding instance of cdrqCmtsCmPollerCommunity. This object is implemented to support SNMPv3

cdrqCmtsCmPollerContextNameSnmpAdminString(SIZE(0..32))read-write
.1.3.6.1.4.1.9.10.59.1.1.5

The context in which management information is accessed when using the user name specified by the corresponding instance of cdrqCmtsCmPollerCommunity. This object is implemented to support SNMPv3

cdrqCmtsCmPollerStartTimeTimeStampread-only
.1.3.6.1.4.1.9.10.59.1.1.6

The value of sysUpTime when the last polling cycle started. cdrqCmtsCmPollerStartTime is set to 0 when the CMTS is first restarted and doesn't get reset after the poller is disabled.

cdrqCmtsCmPollerStopTimeTimeStampread-only
.1.3.6.1.4.1.9.10.59.1.1.7

The value of sysUpTime when the last polling cycle finished. cdrqCmtsCmPollerStopTime is set to 0 when the CMTS is first restarted and doesn't get reset after the poller is disabled.

cdrqCmtsCmStatusEntryCdrqCmtsCmStatusEntrynot-accessible
.1.3.6.1.4.1.9.10.59.1.2.1.1

A list of the cable modem's attributes that are polled by a CMTS.

cdrqCmtsCmDownChannelPowerTenthdBmVread-only
.1.3.6.1.4.1.9.10.59.1.2.1.1.1

The CM's received power level. This object may be set to zero if the CM does not support power level measurement. If the CM downstream interface is down, this object either returns the most current value or the value of 0.

cdrqCmtsCmStatusTxPowerTenthdBmVread-only
.1.3.6.1.4.1.9.10.59.1.2.1.1.2

The operational transmit power for the CM upstream channel.

cdrqCmtsCmUpChnlTxTimingOffsetGaugeread-only
.1.3.6.1.4.1.9.10.59.1.2.1.1.3

A measure of the current round trip time. Used for timing of CM upstream transmissions to ensure synchronized arrivals at the CMTS.

cdrqCmtsCmSigQSignalNoiseTenthdBread-only
.1.3.6.1.4.1.9.10.59.1.2.1.1.4

Signal/Noise ratio as perceived for the CM downstream channel.

cdrqCmtsCmSigQMicroreflectionsINTEGER(0..255)read-only
.1.3.6.1.4.1.9.10.59.1.2.1.1.5

Total microreflections including in-channel response as perceived on the CM downstream, measured in dBc below the signal level. This object is not assumed to return an absolutely accurate value, but is meant to give a rough indication of microreflections received on this interface. It is up to the implementor to provide information as accurate as possible.

cdrqCmtsCmPollTimeTimeStampread-only
.1.3.6.1.4.1.9.10.59.1.2.1.1.6

The value of sysUpTime when this CM entry was polled. If this value is larger than the cdrqCmtsCmPollerStopTime, either by receiving it from the cdrqCmtsCmRQDoneNotification or by polling the object itself, it indicates that the status has already been overwritten by a new polling cycle. To avoid this to happen, the NMS can increase the cdrqCmtsCmPollInterval so that the cdrqCmtsCmPollTime would fall in between the cdrqCmtsCmPollerStartTime and the cdrqCmtsCmPollerStopTime.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→