CISCO-DOCS-REMOTE-QUERY-MIB
The CISCO-DOCS-REMOTE-QUERY-MIB configures and monitors the CMTS CM Poller service on Cisco Cable Modem Termination Systems to facilitate SNMP polling of remote cable modems. It exposes configuration parameters and operational status objects for both the polling engine and the specific remote cable modems targeted by the poller.
Imported Objects
Objects
29 total| Object Name |
|---|
ciscoDocsRemoteQueryMIB OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.59 |
CISCO-DOCS-EXT-MIB Unknown .1.3.6.1.4.1.9.10.59 |
ciscoDocsRemQueryMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.59.1 |
cdrqPoller OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.59.1.1 |
cdrqCmtsCmPollerEnablerw TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } .1.3.6.1.4.1.9.10.59.1.1.1 |
cdrqCmtsCmPollerIntervalrw TimeInterval .1.3.6.1.4.1.9.10.59.1.1.2 |
cdrqCmtsCmPollerCommunityrw OCTET STRING .1.3.6.1.4.1.9.10.59.1.1.3 |
cdrqCmtsCmPollerContextEngineIDrw SnmpEngineID -- Rsyntax OCTET STRING .1.3.6.1.4.1.9.10.59.1.1.4 |
cdrqCmtsCmPollerContextNamerw SnmpAdminString .1.3.6.1.4.1.9.10.59.1.1.5 |
cdrqCmtsCmPollerStartTimero TimeStamp -- Rsyntax TimeTicks .1.3.6.1.4.1.9.10.59.1.1.6 |
cdrqCmtsCmPollerStopTimero TimeStamp -- Rsyntax TimeTicks .1.3.6.1.4.1.9.10.59.1.1.7 |
cdrqCM OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.59.1.2 |
cdrqCmtsCmStatusTable SEQUENCE OF CdrqCmtsCmStatusEntry .1.3.6.1.4.1.9.10.59.1.2.1 |
cdrqCmtsCmStatusEntry CdrqCmtsCmStatusEntry .1.3.6.1.4.1.9.10.59.1.2.1.1 |
cdrqCmtsCmDownChannelPowerro TenthdBmV -- Rsyntax INTEGER -- Units -- dBmV .1.3.6.1.4.1.9.10.59.1.2.1.1.1 |
cdrqCmtsCmStatusTxPowerro TenthdBmV -- Rsyntax INTEGER -- Units -- dBmV .1.3.6.1.4.1.9.10.59.1.2.1.1.2 |
cdrqCmtsCmUpChnlTxTimingOffsetro Gauge .1.3.6.1.4.1.9.10.59.1.2.1.1.3 |
cdrqCmtsCmSigQSignalNoisero TenthdB -- Rsyntax INTEGER -- Units -- dB .1.3.6.1.4.1.9.10.59.1.2.1.1.4 |
cdrqCmtsCmSigQMicroreflectionsro INTEGER .1.3.6.1.4.1.9.10.59.1.2.1.1.5 |
cdrqCmtsCmPollTimero TimeStamp -- Rsyntax TimeTicks .1.3.6.1.4.1.9.10.59.1.2.1.1.6 |
ciscoDocsRQNotificationsPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.59.2 |
ciscoDocsRQNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.59.2.0 |
cdrqCmtsCmRQDoneNotification TRAP-TYPE .1.3.6.1.4.1.9.10.59.2.0.1 |
ciscoDocsRemoteQueryConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.59.3 |
cdrqDocsRemoteQueryCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.59.3.1 |
cdrqDocsRemoteQueryCompliance OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.59.3.1.1 |
cdrqDocsRemoteQueryGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.59.3.2 |
cdrqPollerGroup OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.59.3.2.1 |
cdrqCMGroup OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.59.3.2.2 |
CISCO-DOCS-REMOTE-QUERY-MIB Technical Reference Overview
The CISCO-DOCS-REMOTE-QUERY-MIB SNMP MIB module published by Cisco defines 29 managed OID objects, including 14 scalar/column metrics, 1 SNMP tables, and 1 trap/notification events. Key tabular structures include cdrqCmtsCmStatusTable. Monitored SNMP traps/notifications include cdrqCmtsCmRQDoneNotification.
Key OID Definitions in CISCO-DOCS-REMOTE-QUERY-MIB
.1.3.6.1.4.1.9.10.59.1.2.1This table contains the status of the cable modems that are polled by the CMTS CM Poller. The information will be overwritten when a new polling cycle starts. The removal of CM from the list or adding a new CM to the list won't be reflected until the next polling cycle. Depending on how many CMs that the poller is polling, polling this table constantly can be quite expensive; Therefore, it is best to poll upon receipt of the cdrqCmtsCmRQDoneNotification. As a hedge against lost notifications, periodic background polling should be performed. Howerver, excessive polling could degrade performance.
.1.3.6.1.4.1.9.10.59.2.0.1This notification is sent when CMTS CM Poller finished polling for the current cycle. The cdrqCmtsCmPollerStartTime is the time when the polling cycle started. The cdrqCmtsCmPollerStopTime is the time when the polling cycle finished.
.1.3.6.1.4.1.9.10.59.1.1.1An indication of whether the CMTS CM Poller is running. When the poller is enabled, it polls the remote CMs periodically specified in the cdrqCmtsCmPollerInterval mib object. The operation can be expensive depending on how many CMs that the poller would be polling. It is suggested to have it disabled when not needed.
.1.3.6.1.4.1.9.10.59.1.1.2An interval between two polling cycles of the CMTS CM Poller. The poller will not start the next cycle until it finished polling for the last CM , even though the time has expired. If the cdrqCmtsCmPollerInterval is too small with a large number of CMs, the poller would tie up the CPU and resources and possibly degrade the system's performance. Any change in the cdrqCmtsCmPollerInterval will not be reflected if the poller has already been enabled.
.1.3.6.1.4.1.9.10.59.1.1.3The read community string is used for polling the CMs. Any change in the cdrqCmtsCmPollerCommunity will not be reflected if the poller has already been enabled. For SNMPv3, this object will contain a user name instead of a community string.
.1.3.6.1.4.1.9.10.59.1.1.4The contextEngineID indicating the location of the context in which management information is accessed when using the user name specified by the corresponding instance of cdrqCmtsCmPollerCommunity. This object is implemented to support SNMPv3
.1.3.6.1.4.1.9.10.59.1.1.5The context in which management information is accessed when using the user name specified by the corresponding instance of cdrqCmtsCmPollerCommunity. This object is implemented to support SNMPv3
.1.3.6.1.4.1.9.10.59.1.1.6The value of sysUpTime when the last polling cycle started. cdrqCmtsCmPollerStartTime is set to 0 when the CMTS is first restarted and doesn't get reset after the poller is disabled.
.1.3.6.1.4.1.9.10.59.1.1.7The value of sysUpTime when the last polling cycle finished. cdrqCmtsCmPollerStopTime is set to 0 when the CMTS is first restarted and doesn't get reset after the poller is disabled.
.1.3.6.1.4.1.9.10.59.1.2.1.1A list of the cable modem's attributes that are polled by a CMTS.
.1.3.6.1.4.1.9.10.59.1.2.1.1.1The CM's received power level. This object may be set to zero if the CM does not support power level measurement. If the CM downstream interface is down, this object either returns the most current value or the value of 0.
.1.3.6.1.4.1.9.10.59.1.2.1.1.2The operational transmit power for the CM upstream channel.
.1.3.6.1.4.1.9.10.59.1.2.1.1.3A measure of the current round trip time. Used for timing of CM upstream transmissions to ensure synchronized arrivals at the CMTS.
.1.3.6.1.4.1.9.10.59.1.2.1.1.4Signal/Noise ratio as perceived for the CM downstream channel.
.1.3.6.1.4.1.9.10.59.1.2.1.1.5Total microreflections including in-channel response as perceived on the CM downstream, measured in dBc below the signal level. This object is not assumed to return an absolutely accurate value, but is meant to give a rough indication of microreflections received on this interface. It is up to the implementor to provide information as accurate as possible.
.1.3.6.1.4.1.9.10.59.1.2.1.1.6The value of sysUpTime when this CM entry was polled. If this value is larger than the cdrqCmtsCmPollerStopTime, either by receiving it from the cdrqCmtsCmRQDoneNotification or by polling the object itself, it indicates that the status has already been overwritten by a new polling cycle. To avoid this to happen, the NMS can increase the cdrqCmtsCmPollInterval so that the cdrqCmtsCmPollTime would fall in between the cdrqCmtsCmPollerStartTime and the cdrqCmtsCmPollerStopTime.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.