CISCO-DMN-DSG-DR-MIB
The CISCO-DMN-DSG-DR-MIB module provides SNMP access to monitor and manage the state, configuration, and performance metrics of Cisco Dynamic Resource (DR) components within the Cisco Data Center Network Manager (DCNM) Distributed Services Gateway architecture. It exposes specific counters and status indicators for DR instances, including operational states, resource allocation statistics, and interface utilization relevant to the distributed gateway fabric.
Imported Objects
Objects
31 total| Object Name |
|---|
ciscoDSGDR MODULE-IDENTITY .1.3.6.1.4.1.1429.2.2.5.43 |
IMPORTS Unknown .1.3.6.1.4.1.1429.2.2.5.43 |
drGlobalCfg OBJECT IDENTIFIER .1.3.6.1.4.1.1429.2.2.5.43.1 |
enablerw Enumeration .1.3.6.1.4.1.1429.2.2.5.43.1.1 |
sigLockTimerw INTEGER .1.3.6.1.4.1.1429.2.2.5.43.1.2 |
sigLossTimerw INTEGER .1.3.6.1.4.1.1429.2.2.5.43.1.3 |
verifyTimerrw INTEGER .1.3.6.1.4.1.1429.2.2.5.43.1.4 |
profilerw Enumeration .1.3.6.1.4.1.1429.2.2.5.43.1.5 |
backupTransportTable SEQUENCE OF BackupTransportEntry .1.3.6.1.4.1.1429.2.2.5.43.2 |
backupTransportEntry BackupTransportEntry .1.3.6.1.4.1.1429.2.2.5.43.2.1 |
backupTransportIndexro Integer32 .1.3.6.1.4.1.1429.2.2.5.43.2.1.1 |
backupTransportSetIdxrw Integer32 .1.3.6.1.4.1.1429.2.2.5.43.2.1.2 |
backupTransportDvbsFecrw Enumeration .1.3.6.1.4.1.1429.2.2.5.43.2.1.3 |
backupTransportEwFlagrw Enumeration .1.3.6.1.4.1.1429.2.2.5.43.2.1.4 |
backupTransportFrequencyrw Integer32 .1.3.6.1.4.1.1429.2.2.5.43.2.1.5 |
backupTransportRFInputrw Enumeration .1.3.6.1.4.1.1429.2.2.5.43.2.1.6 |
backupTransportModSysrw Enumeration .1.3.6.1.4.1.1429.2.2.5.43.2.1.7 |
backupTransportNetIdrw Integer32 .1.3.6.1.4.1.1429.2.2.5.43.2.1.8 |
backupTransportOrbitalPosrw Integer32 .1.3.6.1.4.1.1429.2.2.5.43.2.1.9 |
backupTransportOrbpolarizationrw Integer32 .1.3.6.1.4.1.1429.2.2.5.43.2.1.10 |
backupTransportSymbRaterw Integer32 .1.3.6.1.4.1.1429.2.2.5.43.2.1.11 |
backupTransportRollOffFactorrw Enumeration .1.3.6.1.4.1.1429.2.2.5.43.2.1.12 |
backupTransportRowstatusrw Enumeration .1.3.6.1.4.1.1429.2.2.5.43.2.1.13 |
backupSetTable SEQUENCE OF BackupSetEntry .1.3.6.1.4.1.1429.2.2.5.43.3 |
backupSetEntry BackupSetEntry .1.3.6.1.4.1.1429.2.2.5.43.3.1 |
backupSetPeidro Integer32 .1.3.6.1.4.1.1429.2.2.5.43.3.1.1 |
backupSetRecidro Integer32 .1.3.6.1.4.1.1429.2.2.5.43.3.1.2 |
backupSetCsiidxro Integer32 .1.3.6.1.4.1.1429.2.2.5.43.3.1.3 |
backupSetBkpchrw Integer32 .1.3.6.1.4.1.1429.2.2.5.43.3.1.4 |
backupSetBkpchDispTextro DisplayString .1.3.6.1.4.1.1429.2.2.5.43.3.1.5 |
backupSetRowStatusrw Enumeration .1.3.6.1.4.1.1429.2.2.5.43.3.1.6 |
CISCO-DMN-DSG-DR-MIB Technical Reference Overview
The CISCO-DMN-DSG-DR-MIB SNMP MIB module published by Cisco defines 31 managed OID objects, including 25 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.1429.2.2.5.43. Key tabular structures include backupTransportTable, backupSetTable.
Key OID Definitions in CISCO-DMN-DSG-DR-MIB
.1.3.6.1.4.1.1429.2.2.5.43Cisco generic DR MIB.
.1.3.6.1.4.1.1429.2.2.5.43.2DR BackupTransport Configuration Table.
.1.3.6.1.4.1.1429.2.2.5.43.3DR BackupSet Configuration Table.
.1.3.6.1.4.1.1429.2.2.5.43Cisco generic DR MIB.
.1.3.6.1.4.1.1429.2.2.5.43.1.1Disable/Enable Disaster Recovery Feature
.1.3.6.1.4.1.1429.2.2.5.43.1.2Signal Lock timer (In Seconds)
.1.3.6.1.4.1.1429.2.2.5.43.1.3Signal Loss timer (In Seconds)
.1.3.6.1.4.1.1429.2.2.5.43.1.4Verify timer (In Seconds)
.1.3.6.1.4.1.1429.2.2.5.43.1.5Local/Uplink Disaster Recovery Profile
.1.3.6.1.4.1.1429.2.2.5.43.2.1Entry for Disaster Recovery BackupTransport Configuration.
.1.3.6.1.4.1.1429.2.2.5.43.2.1.1DR CSI record index
.1.3.6.1.4.1.1429.2.2.5.43.2.1.2DR CSI Idx.
.1.3.6.1.4.1.1429.2.2.5.43.2.1.3DR DVBS Forward Error Correction: Forward Error Correction Rate. For DVB-S2 modulation only auto is applicable. For DVB-S modulation all options are applicable.
.1.3.6.1.4.1.1429.2.2.5.43.2.1.4DR E/W Flag
.1.3.6.1.4.1.1429.2.2.5.43.2.1.5DR Frequency: The Satellite Downlink frequency in the range of 0 to 15000000 KHz in steps of 1 KHz..
.1.3.6.1.4.1.1429.2.2.5.43.2.1.6DR Input: Select Input for tuning
.1.3.6.1.4.1.1429.2.2.5.43.2.1.7DR Modulation System.
.1.3.6.1.4.1.1429.2.2.5.43.2.1.8Network Id.
.1.3.6.1.4.1.1429.2.2.5.43.2.1.9DR Orbital Position
.1.3.6.1.4.1.1429.2.2.5.43.2.1.10Orbital location Azimuth.The range is from 0 to 3600 in steps of 1. The scaling factor is 1 10th of a degree
.1.3.6.1.4.1.1429.2.2.5.43.2.1.11Data rate on the transport stream in millions of symbols per second. Range is from 10000 to 450000 hectoSym/second in steps of 1 hectoSym/second. ( 1 hecto = 10^2 ).
.1.3.6.1.4.1.1429.2.2.5.43.2.1.12DR Rollof Factor:Alpha filtering - for DVB-S: 0.20/0.35, for DVB-S2: 0.20/0.25/0.35. Roll off with scaling factor of 1/100.
.1.3.6.1.4.1.1429.2.2.5.43.2.1.13RowStatus.
.1.3.6.1.4.1.1429.2.2.5.43.3.1Entry for Disaster Recovery BackupSet Configuration.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.