Home/Catalog/CISCO-DMN-DSG-DR-MIB

CISCO-DMN-DSG-DR-MIB

AI MIB Summary

The CISCO-DMN-DSG-DR-MIB module provides SNMP access to monitor and manage the state, configuration, and performance metrics of Cisco Dynamic Resource (DR) components within the Cisco Data Center Network Manager (DCNM) Distributed Services Gateway architecture. It exposes specific counters and status indicators for DR instances, including operational states, resource allocation statistics, and interface utilization relevant to the distributed gateway fabric.

Cisco generic DR MIB.
Main OID:
ciscoDSGDR.1.3.6.1.4.1.1429.2.2.5.43
31
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

31 total
Object Name
ciscoDSGDR
MODULE-IDENTITY
.1.3.6.1.4.1.1429.2.2.5.43
IMPORTS
Unknown
.1.3.6.1.4.1.1429.2.2.5.43
drGlobalCfg
OBJECT IDENTIFIER
.1.3.6.1.4.1.1429.2.2.5.43.1
enablerw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.43.1.1
sigLockTimerw
INTEGER
.1.3.6.1.4.1.1429.2.2.5.43.1.2
sigLossTimerw
INTEGER
.1.3.6.1.4.1.1429.2.2.5.43.1.3
verifyTimerrw
INTEGER
.1.3.6.1.4.1.1429.2.2.5.43.1.4
profilerw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.43.1.5
backupTransportTable
SEQUENCE OF BackupTransportEntry
.1.3.6.1.4.1.1429.2.2.5.43.2
backupTransportEntry
BackupTransportEntry
.1.3.6.1.4.1.1429.2.2.5.43.2.1
backupTransportIndexro
Integer32
.1.3.6.1.4.1.1429.2.2.5.43.2.1.1
backupTransportSetIdxrw
Integer32
.1.3.6.1.4.1.1429.2.2.5.43.2.1.2
backupTransportDvbsFecrw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.43.2.1.3
backupTransportEwFlagrw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.43.2.1.4
backupTransportFrequencyrw
Integer32
.1.3.6.1.4.1.1429.2.2.5.43.2.1.5
backupTransportRFInputrw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.43.2.1.6
backupTransportModSysrw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.43.2.1.7
backupTransportNetIdrw
Integer32
.1.3.6.1.4.1.1429.2.2.5.43.2.1.8
backupTransportOrbitalPosrw
Integer32
.1.3.6.1.4.1.1429.2.2.5.43.2.1.9
backupTransportOrbpolarizationrw
Integer32
.1.3.6.1.4.1.1429.2.2.5.43.2.1.10
backupTransportSymbRaterw
Integer32
.1.3.6.1.4.1.1429.2.2.5.43.2.1.11
backupTransportRollOffFactorrw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.43.2.1.12
backupTransportRowstatusrw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.43.2.1.13
backupSetTable
SEQUENCE OF BackupSetEntry
.1.3.6.1.4.1.1429.2.2.5.43.3
backupSetEntry
BackupSetEntry
.1.3.6.1.4.1.1429.2.2.5.43.3.1
backupSetPeidro
Integer32
.1.3.6.1.4.1.1429.2.2.5.43.3.1.1
backupSetRecidro
Integer32
.1.3.6.1.4.1.1429.2.2.5.43.3.1.2
backupSetCsiidxro
Integer32
.1.3.6.1.4.1.1429.2.2.5.43.3.1.3
backupSetBkpchrw
Integer32
.1.3.6.1.4.1.1429.2.2.5.43.3.1.4
backupSetBkpchDispTextro
DisplayString
.1.3.6.1.4.1.1429.2.2.5.43.3.1.5
backupSetRowStatusrw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.43.3.1.6

CISCO-DMN-DSG-DR-MIB Technical Reference Overview

The CISCO-DMN-DSG-DR-MIB SNMP MIB module published by Cisco defines 31 managed OID objects, including 25 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.1429.2.2.5.43. Key tabular structures include backupTransportTable, backupSetTable.

Key OID Definitions in CISCO-DMN-DSG-DR-MIB

ciscoDSGDRMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.1429.2.2.5.43

Cisco generic DR MIB.

backupTransportTableSEQUENCEnot-accessible
.1.3.6.1.4.1.1429.2.2.5.43.2

DR BackupTransport Configuration Table.

backupSetTableSEQUENCEnot-accessible
.1.3.6.1.4.1.1429.2.2.5.43.3

DR BackupSet Configuration Table.

IMPORTSunknownunknown
.1.3.6.1.4.1.1429.2.2.5.43

Cisco generic DR MIB.

enableINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.43.1.1

Disable/Enable Disaster Recovery Feature

sigLockTimeINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.43.1.2

Signal Lock timer (In Seconds)

sigLossTimeINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.43.1.3

Signal Loss timer (In Seconds)

verifyTimerINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.43.1.4

Verify timer (In Seconds)

profileINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.43.1.5

Local/Uplink Disaster Recovery Profile

backupTransportEntryBackupTransportEntrynot-accessible
.1.3.6.1.4.1.1429.2.2.5.43.2.1

Entry for Disaster Recovery BackupTransport Configuration.

backupTransportIndexInteger32read-only
.1.3.6.1.4.1.1429.2.2.5.43.2.1.1

DR CSI record index

backupTransportSetIdxInteger32read-write
.1.3.6.1.4.1.1429.2.2.5.43.2.1.2

DR CSI Idx.

backupTransportDvbsFecINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.43.2.1.3

DR DVBS Forward Error Correction: Forward Error Correction Rate. For DVB-S2 modulation only auto is applicable. For DVB-S modulation all options are applicable.

backupTransportEwFlagINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.43.2.1.4

DR E/W Flag

backupTransportFrequencyInteger32read-write
.1.3.6.1.4.1.1429.2.2.5.43.2.1.5

DR Frequency: The Satellite Downlink frequency in the range of 0 to 15000000 KHz in steps of 1 KHz..

backupTransportRFInputINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.43.2.1.6

DR Input: Select Input for tuning

backupTransportModSysINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.43.2.1.7

DR Modulation System.

backupTransportNetIdInteger32read-write
.1.3.6.1.4.1.1429.2.2.5.43.2.1.8

Network Id.

backupTransportOrbitalPosInteger32(0..3600)read-write
.1.3.6.1.4.1.1429.2.2.5.43.2.1.9

DR Orbital Position

backupTransportOrbpolarizationInteger32(0..3600)read-write
.1.3.6.1.4.1.1429.2.2.5.43.2.1.10

Orbital location Azimuth.The range is from 0 to 3600 in steps of 1. The scaling factor is 1 10th of a degree

backupTransportSymbRateInteger32read-write
.1.3.6.1.4.1.1429.2.2.5.43.2.1.11

Data rate on the transport stream in millions of symbols per second. Range is from 10000 to 450000 hectoSym/second in steps of 1 hectoSym/second. ( 1 hecto = 10^2 ).

backupTransportRollOffFactorINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.43.2.1.12

DR Rollof Factor:Alpha filtering - for DVB-S: 0.20/0.35, for DVB-S2: 0.20/0.25/0.35. Roll off with scaling factor of 1/100.

backupTransportRowstatusINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.43.2.1.13

RowStatus.

backupSetEntryBackupSetEntrynot-accessible
.1.3.6.1.4.1.1429.2.2.5.43.3.1

Entry for Disaster Recovery BackupSet Configuration.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→