Home/Catalog/CISCO-DMN-DSG-DISEQC-DISH-POSITION-MIB

CISCO-DMN-DSG-DISEQC-DISH-POSITION-MIB

AI MIB Summary

The CISCO-DMN-DSG-DISEQC-DISH-POSITION-MIB enables SNMP-based monitoring and control of DiSEqC (Digital Satellite Equipment Controller) dish positioning parameters on Cisco DSG (Digital Satellite Gateway) hardware. It exposes specific metrics for satellite receiver azimuth and elevation angles, motor status, and DiSEqC command execution states to facilitate automated alignment and fault detection in satellite distribution networks.

Cisco DiSEqC Dish Position MIB.
Main OID:
ciscoDSGDiSEqC.1.3.6.1.4.1.1429.2.2.5.19
18
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

18 total
Object Name
ciscoDSGDiSEqC
MODULE-IDENTITY
.1.3.6.1.4.1.1429.2.2.5.19
diSEqCTable
SEQUENCE OF DiSEqCEntry
.1.3.6.1.4.1.1429.2.2.5.19.1
diSEqCEntry
DiSEqCEntry
.1.3.6.1.4.1.1429.2.2.5.19.1.1
diSEqCInstance
Integer32
.1.3.6.1.4.1.1429.2.2.5.19.1.1.1
diSEqCEnablerw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.19.1.1.2
diSEqCDishPositionrw
Integer32
.1.3.6.1.4.1.1429.2.2.5.19.1.1.3
diSEqCPositionJogrw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.19.1.1.4
diSEqCEWFlagrw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.19.1.1.5
diSEqCSatSelectrw
Integer32
.1.3.6.1.4.1.1429.2.2.5.19.1.1.6
diSEqCInstallerActionrw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.19.1.1.7
diSEqCUserActionrw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.19.1.1.8
diSEqCModerw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.19.1.1.9
diSEqCActionrw
Enumeration
.1.3.6.1.4.1.1429.2.2.5.19.1.1.10
diSEqCStatusModero
Enumeration
.1.3.6.1.4.1.1429.2.2.5.19.1.1.11
diSEqCStatusDishPositionro
DisplayString
.1.3.6.1.4.1.1429.2.2.5.19.1.1.12
diSEqCStatusEastWestFlagro
Enumeration
.1.3.6.1.4.1.1429.2.2.5.19.1.1.13
diSEqCStatusLastActionro
Enumeration
.1.3.6.1.4.1.1429.2.2.5.19.1.1.14
diSEqCStatusEnablero
Enumeration
.1.3.6.1.4.1.1429.2.2.5.19.1.1.15

CISCO-DMN-DSG-DISEQC-DISH-POSITION-MIB Technical Reference Overview

The CISCO-DMN-DSG-DISEQC-DISH-POSITION-MIB SNMP MIB module published by Cisco defines 18 managed OID objects, including 15 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.1429.2.2.5.19. Key tabular structures include diSEqCTable.

Key OID Definitions in CISCO-DMN-DSG-DISEQC-DISH-POSITION-MIB

ciscoDSGDiSEqCMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.1429.2.2.5.19

Cisco DiSEqC Dish Position MIB.

diSEqCTableSEQUENCEnot-accessible
.1.3.6.1.4.1.1429.2.2.5.19.1

DiSEqC Table.

diSEqCActionINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.19.1.1.10

DiSEqC Control Action.Setting this MIB object to activate( 2 ) moves the dish to the position determined by the diSEqC setting parameters.

diSEqCDishPositionInteger32read-write
.1.3.6.1.4.1.1429.2.2.5.19.1.1.3

Absolute Dish Position in steps of 1. The scaling factor is 1/10.

diSEqCEWFlagINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.19.1.1.5

Dish direction.

diSEqCEnableINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.19.1.1.2

DiSEqC On/off.

diSEqCEntryDiSEqCEntrynot-accessible
.1.3.6.1.4.1.1429.2.2.5.19.1.1

Entry for DiSEqC Table.

diSEqCInstallerActionINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.19.1.1.7

Installer Action.

diSEqCInstanceInteger32not-accessible
.1.3.6.1.4.1.1429.2.2.5.19.1.1.1

Instance for DiSEqC Table.

diSEqCModeINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.19.1.1.9

Installation Mode,User has limited rights.

diSEqCPositionJogINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.19.1.1.4

Dish position fine adjustment - amount of steps ( each step is 2 degrees ). This is a diSEqc control object.

diSEqCSatSelectInteger32read-write
.1.3.6.1.4.1.1429.2.2.5.19.1.1.6

Satellite Select.

diSEqCStatusDishPositionDisplayStringread-only
.1.3.6.1.4.1.1429.2.2.5.19.1.1.12

Dish Position Status.The range is from 0.0 to 75.0 in steps of 0.1.

diSEqCStatusEastWestFlagINTEGERread-only
.1.3.6.1.4.1.1429.2.2.5.19.1.1.13

DiSEqC East/West Flag Status.

diSEqCStatusEnableINTEGERread-only
.1.3.6.1.4.1.1429.2.2.5.19.1.1.15

DiSEqC Status - Enable Status.

diSEqCStatusLastActionINTEGERread-only
.1.3.6.1.4.1.1429.2.2.5.19.1.1.14

DiSEqC Status - Last Action.

diSEqCStatusModeINTEGERread-only
.1.3.6.1.4.1.1429.2.2.5.19.1.1.11

DiSEqC Mode Status.

diSEqCUserActionINTEGERread-write
.1.3.6.1.4.1.1429.2.2.5.19.1.1.8

User Action.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→