CISCO-DM-MIB
The CISCO-DM-MIB enables monitoring and management of Fibre Channel SAN domain management functions, specifically tracking the operational state, configuration parameters, and event logs of the Domain Manager software executing across Cisco principal and non-principal switches.
Imported Objects
Objects
73 total| Object Name |
|---|
ciscoDmMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.302 |
ciscoDmMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.302.1 |
dmConfiguration OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.302.1.1 |
dmTable SEQUENCE OF DmEntry .1.3.6.1.4.1.9.9.302.1.1.1 |
dmEntry DmEntry .1.3.6.1.4.1.9.9.302.1.1.1.1 |
dmConfigDomainIdrw DomainIdOrZero (CISCO-ST-TC) .1.3.6.1.4.1.9.9.302.1.1.1.1.1 |
dmConfigDomainIdTyperw Enumeration .1.3.6.1.4.1.9.9.302.1.1.1.1.2 |
dmEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.302.1.1.1.1.3 |
dmAutoReconfigurerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.302.1.1.1.1.4 |
dmContiguousAllocationrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.302.1.1.1.1.5 |
dmPriorityrw DomainPriority .1.3.6.1.4.1.9.9.302.1.1.1.1.6 |
dmRestartrw Enumeration .1.3.6.1.4.1.9.9.302.1.1.1.1.7 |
dmFabricNamerw FcNameIdOrZero (CISCO-ST-TC) .1.3.6.1.4.1.9.9.302.1.1.1.1.8 |
dmPrincipalSwitchWwnro FcNameIdOrZero (CISCO-ST-TC) .1.3.6.1.4.1.9.9.302.1.1.1.1.9 |
dmLocalSwitchWwnro FcNameIdOrZero (CISCO-ST-TC) .1.3.6.1.4.1.9.9.302.1.1.1.1.10 |
dmAssignedAreaIdListro OCTET STRING .1.3.6.1.4.1.9.9.302.1.1.1.1.11 |
dmFcIdsGrantedro Counter32 .1.3.6.1.4.1.9.9.302.1.1.1.1.12 |
dmFcIdsRecoveredro Counter32 .1.3.6.1.4.1.9.9.302.1.1.1.1.13 |
dmFreeFcIdsro Gauge32 .1.3.6.1.4.1.9.9.302.1.1.1.1.14 |
dmAssignedFcIdsro Gauge32 .1.3.6.1.4.1.9.9.302.1.1.1.1.15 |
dmReservedFcIdsro Gauge32 .1.3.6.1.4.1.9.9.302.1.1.1.1.16 |
dmRunningPriorityro DomainPriority .1.3.6.1.4.1.9.9.302.1.1.1.1.17 |
dmPrincSwRunningPriorityro DomainPriority .1.3.6.1.4.1.9.9.302.1.1.1.1.18 |
dmStatero DmState .1.3.6.1.4.1.9.9.302.1.1.1.1.19 |
dmPrincipalSwitchSelectionsro Counter32 .1.3.6.1.4.1.9.9.302.1.1.1.1.20 |
dmBuildFabricsro Counter32 .1.3.6.1.4.1.9.9.302.1.1.1.1.21 |
dmFabricReconfiguresro Counter32 .1.3.6.1.4.1.9.9.302.1.1.1.1.22 |
dmDomainIdro DomainIdOrZero (CISCO-ST-TC) .1.3.6.1.4.1.9.9.302.1.1.1.1.23 |
dmLocalPrincipalSwitchSelctnsro Counter32 .1.3.6.1.4.1.9.9.302.1.1.1.1.24 |
dmFcIdPersistencyrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.302.1.1.1.1.25 |
dmFcIdPurgerw Enumeration .1.3.6.1.4.1.9.9.302.1.1.1.1.26 |
dmIfTable SEQUENCE OF DmIfEntry .1.3.6.1.4.1.9.9.302.1.1.2 |
dmIfEntry DmIfEntry .1.3.6.1.4.1.9.9.302.1.1.2.1 |
dmIfRcfRejectrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.302.1.1.2.1.1 |
dmIfRolero DomainInterfaceRole .1.3.6.1.4.1.9.9.302.1.1.2.1.2 |
dmIfRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.302.1.1.2.1.3 |
dmReConfFabricChangeNotifyEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.302.1.1.3 |
dmFcIdPersistencyTable SEQUENCE OF DmFcIdPersistencyEntry .1.3.6.1.4.1.9.9.302.1.1.4 |
dmFcIdPersistencyEntry DmFcIdPersistencyEntry .1.3.6.1.4.1.9.9.302.1.1.4.1 |
dmFcIdPersistencyWwn FcNameId (CISCO-ST-TC) .1.3.6.1.4.1.9.9.302.1.1.4.1.1 |
dmFcIdPersistencyFcIdrw FcAddressId (CISCO-ST-TC) .1.3.6.1.4.1.9.9.302.1.1.4.1.2 |
dmFcIdPersistencyNumrw Enumeration .1.3.6.1.4.1.9.9.302.1.1.4.1.3 |
dmFcIdPersistencyUsedro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.302.1.1.4.1.4 |
dmFcIdPersistencyTyperw Enumeration .1.3.6.1.4.1.9.9.302.1.1.4.1.5 |
dmFcIdPersistencyRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.302.1.1.4.1.6 |
dmAllowedDomainIDListTable SEQUENCE OF DmAllowedDomainIDListEntry .1.3.6.1.4.1.9.9.302.1.1.5 |
dmAllowedDomainIDListEntry DmAllowedDomainIDListEntry .1.3.6.1.4.1.9.9.302.1.1.5.1 |
dmAllowedDomainIDListId Unsigned32 .1.3.6.1.4.1.9.9.302.1.1.5.1.1 |
dmAllowedDomainIDListrw OCTET STRING .1.3.6.1.4.1.9.9.302.1.1.5.1.2 |
dmAllowedDomainIDListUserro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.302.1.1.5.1.3 |
dmInfo OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.302.1.2 |
dmAreaTable SEQUENCE OF DmAreaEntry .1.3.6.1.4.1.9.9.302.1.2.1 |
dmAreaEntry DmAreaEntry .1.3.6.1.4.1.9.9.302.1.2.1.1 |
dmAreaAreaId Unsigned32 .1.3.6.1.4.1.9.9.302.1.2.1.1.1 |
dmAreaAssignedPortIdListro OCTET STRING .1.3.6.1.4.1.9.9.302.1.2.1.1.2 |
dmDatabaseTable SEQUENCE OF DmDatabaseEntry .1.3.6.1.4.1.9.9.302.1.2.2 |
dmDatabaseEntry DmDatabaseEntry .1.3.6.1.4.1.9.9.302.1.2.2.1 |
dmDatabaseDomainId DomainId (CISCO-ST-TC) .1.3.6.1.4.1.9.9.302.1.2.2.1.1 |
dmDatabaseSwitchWwnro FcNameId (CISCO-ST-TC) .1.3.6.1.4.1.9.9.302.1.2.2.1.2 |
dmMaxFcIdCacheSizero Unsigned32 .1.3.6.1.4.1.9.9.302.1.2.3 |
dmFcIdCacheTable SEQUENCE OF DmFcIdCacheEntry .1.3.6.1.4.1.9.9.302.1.2.4 |
dmFcIdCacheEntry DmFcIdCacheEntry .1.3.6.1.4.1.9.9.302.1.2.4.1 |
dmFcIdCacheWwn FcNameId (CISCO-ST-TC) .1.3.6.1.4.1.9.9.302.1.2.4.1.1 |
dmFcIdCacheAreaIdPortIdro OCTET STRING .1.3.6.1.4.1.9.9.302.1.2.4.1.2 |
dmFcIdCachePortIdsro Unsigned32 .1.3.6.1.4.1.9.9.302.1.2.4.1.3 |
dmNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.302.1.3 |
dmNotification OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.302.1.3.0 |
dmDomainIdNotAssignedNotify NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.302.1.3.0.1 |
dmNewPrincipalSwitchNotify NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.302.1.3.0.2 |
dmFabricChangeNotify NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.302.1.3.0.3 |
dmMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.302.2 |
dmMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.302.2.1 |
dmMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.302.2.2 |
CISCO-DM-MIB Technical Reference Overview
The CISCO-DM-MIB SNMP MIB module published by Cisco defines 73 managed OID objects, including 47 scalar/column metrics, 7 SNMP tables, and 3 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.302. Key tabular structures include dmTable, dmIfTable, dmAreaTable, dmDatabaseTable, dmFcIdCacheTable, dmFcIdPersistencyTable. Monitored SNMP traps/notifications include dmDomainIdNotAssignedNotify, dmNewPrincipalSwitchNotify, dmFabricChangeNotify.
Key OID Definitions in CISCO-DM-MIB
.1.3.6.1.4.1.9.9.302The MIB module for the domain management functionality defined by the Fibre Channel standards (FC-SW2). For the purposes of this MIB, 'Domain Manager' is the software functionality which executes in both the principal switch and other switches.
.1.3.6.1.4.1.9.9.302.1.1.1This table contains Domain Manager related parameters which can be configured and monitored. There is one entry for each of the VSANs configured on this switch. An entry will be created whenever a VSAN is created on the switch. The entry will be removed when the corresponding VSAN is deleted.
.1.3.6.1.4.1.9.9.302.1.1.2This table contains interface configuration of the domain manager per VSAN. An entry in this table is automatically created when an E_port becomes non-isolated and there is a entry in dmTable for that VSAN. An entry is deleted automatically from this table if : a) the correponding interface becomes non-existent, or b) the correponding interface becomes a non-E_port and all the writable objects has default values. or c) the dmTable entry for the corresponding VSAN is deleted. Entries in this table can be created via dmIfRowStatus only as the means to specify non-default parameter values for an interface at a time when that interface is either down or is a non-E_port. So an entry in this table exists when one or both of these conditions holds: - one or more configuration parameters have non-default values for an interface which is either down or a non-E_port and corresponding VSAN has an entry in the dmTable, and/or - the interface is an E_port and it is up. This has a number of consequences: - an entry exists for a non-E_port or an E_port which is down whenever that interface has non-default parameters and the corresponding VSAN has an entry in the dmTable; - an entry cannot be created (via dmIfRowStatus) for an interface with default parameters; instead, the agent creates/deletes an entry for an interface with default parameters according to whether the E_port is up or down. - an entry can not be created via dmIfRowStatus unless non-default parameter values are (simultaneously) configured for an interface which is a non-E_port or a down interface, and the correspoding VSAN has an entry in the dmTable. - deleting an entry via RowStatus when either the interface is down and configured with non-default values or the interface is up, is equivalent to resetting its parameters to their default values. If the interface is down and was configured with default- values, then the entry would be deleted.
.1.3.6.1.4.1.9.9.302.1.2.1This table contains area statistics on this domain manager per VSAN. Each octet in the dmAssignedAreaList can be used to index this table to find information on each area.
.1.3.6.1.4.1.9.9.302.1.2.2This table contains all information known by the local switch about all the domains which have been assigned in each of the VSANs.
.1.3.6.1.4.1.9.9.302.1.2.4This table contains all the FC IDs that have recently been released. So it lists all the FC IDs that have valid WWN to FC ID mappings and currently not assigned to any ports. These FC ID were assigned to ports and now, have been released. This cached FC ID contains only Area ID and Port ID information. The FC ID cache is kept to provide best effort re-assignment of same FC IDs. i.e, an Nx_port would get the same FC ID when it asks for a FC ID again, after releasing it.
.1.3.6.1.4.1.9.9.302.1.1.4This table lists the FC IDs which are in the FC ID persistency database. The FC ID persistency is a feature which enables FC devices to get same FC IDs even if they disappear and appear back, if enabled. The FC ID persistency database contains information about the FC IDs which are assigned to FC devices either statically (configured) or dynamically. Entries are automatically created when a FC ID is assigned and dmFcIdPersistency is 'true' on this VSAN. The entries can also be created and deleted via the dmFcIdPersistencyRowStatus object. Entries are deleted when corresponding dmFcIdPersistencyType is 'dynamic' and dmFcIdPersistencyUsed is 'false' if the object dmFcIdPurge is set to 'enable'. An entry cannot be created if the dmFcIdPersistency is 'false'. If the dmDomainId is changed on a VSAN, then all the entries on that VSAN in this table are deleted. Also, if the dmConfigDomainId is not equal to dmDomainId on a VSAN, then all the entries in that VSAN are deleted.
.1.3.6.1.4.1.9.9.302.1.1.5This table contains list of allowed domain IDs in the local VSANs. So in a VSAN, domain IDs can be assigned only from the allowed list. All the domain IDs which are not allowed are reserved. Note that this is possible in a VSAN only if the local device is the principal switch in that VSAN.
.1.3.6.1.4.1.9.9.302.1.3.0.1If a Domain ID is not configured or assigned on a VSAN, then the switch may isolate E_ports on that VSAN. The conditions are : - If the Domain Manager is enabled on the local switch and its request for a configured static Domain ID is rejected or no other Domain ID is assigned, then the E_ports are isolated. - If the domain manager is not enabled and if a static Domain ID is not configured on the VSAN, then the switch will isolate all of its E_ports on the VSAN. This notification contains the vsanIndex of the VSAN on which the condition happened.
.1.3.6.1.4.1.9.9.302.1.3.0.2This notification indicates that the sending switch has become the new Principal Switch on a VSAN. This notification is sent soon after its election as the new Principal Switch, i.e., upon expiration of a Principal Switch selection timer which is equal to twice Fabric Stability Timeout value (F_S_TOV). This notification contains the vsanIndex of the VSAN on which the switch became the Principal Switch and the WWN of the switch which became the Principal Switch.
.1.3.6.1.4.1.9.9.302.1.3.0.3This notification is sent whenever a switch sends or receives a Build Fabric (BF) or a ReConfigure Fabric (RCF) message on a VSAN. A switch can receive or issue a BuildFabric (BF) or a ReConfigureFabric (RCF) message under following conditions: - A new link causes two disjoint fabrics in a VSAN to merge into one fabric. The sent/received message is BF if the Domain ID lists on the disjoint fabric does not overlap and it is RCF if they overlap. - An upsteam principal ISL which connects to Principal switch and other switches in a VSAN fails. BF is issued to see if there is an alternative path to the Principal Switch. If not paths exit, then an RCF is issued. - A switch asks for a different set of Domain IDs than the currently assigned list, the Principal switch would issue an RCF. The notification is not sent if a 'dmNewPrincipalSwitchNotify' notification is sent for the same transition. This notification contains the vsanIndex of the VSAN on which RCF was issued.
.1.3.6.1.4.1.9.9.302.1.2.3The maximum number of FC IDs that can be cached in the dmFcIdCacheTable.
.1.3.6.1.4.1.9.9.302.1.1.3Specifies whether or not the local switch should issue a dmFabricChangeNotify notification on sending or receiving ReConfigureFabric (RCF) on a VSAN. If the value of the object is 'true, then the notification is generated. If the value is 'false', notification is not generated.
.1.3.6.1.4.1.9.9.302.1.1.1.1An entry provides information on the domain manager for a VSAN.
.1.3.6.1.4.1.9.9.302.1.1.1.1.1The configured Domain ID of the local switch on this VSAN or zero if no Domain ID has been configured. The meaning of this object depends on dmConfigDomainIdType object. If dmConfigDomainIdType is 'preferred', then domain ID configured is called 'preferred Domain ID'. The valid values are between 0 and 239. In a situation where this domain could not be assigned, any other domain ID would be acceptable. The value '0' means any domain ID. If dmConfigDomainIdType is 'static', then domain ID is called 'static Domain ID' and valid values are between 1 and 239. In a situation where this domain was non-zero but could not be assigned, no other domain ID would be acceptable. If the Domain Manager is enabled on the VSAN, then a RDI (Request Domain ID) will be sent requesting this Domain ID. If no Domain ID can be granted in the case of 'preferred' or if the configured 'static' domain ID cannot be not granted then, it is an error condition. When this error occurs, the E_ports on that VSAN will be isolated and user will be informed via 'dmDomainIdNotAssigned' notification. If the domain manager is not enabled, then the static Domain ID is assumed to be granted, if it has been configured (to a valid number). If either of the domain IDs are not configured with a non-zero value on this VSAN and if the domain manager is not enabled, then - switch will isolate all of its E_ports on this VSAN. - The user will be informed via a notification 'dmDomainIdNotAssigned'.
.1.3.6.1.4.1.9.9.302.1.1.1.1.2Type of configured Domain ID.
.1.3.6.1.4.1.9.9.302.1.1.1.1.3Enables the Domain Manager on this VSAN. If enabled on an active VSAN, the switch will participate in principal switch selection. If disabled, the switch will participate in neither the principal switch selection nor domain allocation. Thus, Domain ID needs to be configured statically.
.1.3.6.1.4.1.9.9.302.1.1.1.1.4This object determines how the switch responds to certain error conditions. The condition that can cause these errors is merging of two disjoint fabrics that have overlapping Domain ID list. If value of this object is 'true', the switch will send a RCF (ReConfigureFabric) to rebuild the Fabric. If 'false' the switch will isolate the E_ports on which the errors happened.
.1.3.6.1.4.1.9.9.302.1.1.1.1.5Determines how the switch behaves when elected as the principal switch. If true, switch won't accept non-contiguous domain IDs in RDIs and will try to replace all the Domain IDs in the list with contiguous domain IDs if a RDI for a contiguous Domain ID can not be fulfilled. If false, then the switch acts normally in granting the Domain IDs even if they are not contiguous.
.1.3.6.1.4.1.9.9.302.1.1.1.1.6Priority of the switch to be used in principal switch selection process.
.1.3.6.1.4.1.9.9.302.1.1.1.1.7This object tells the Domain Manager to rebuild the Domain ID tree all over again. If this object is set to 'disruptive', then a RCF (ReConfigure Fabric) is generated in the VSAN in order for the fabric to recover from the errors. If this object is set to 'nonDisruptive', then a BF (Build Fabric) is generated in the VSAN. No action is taken if this object is set to 'noOp'. The value of the object when read is always 'noOp'.
.1.3.6.1.4.1.9.9.302.1.1.1.1.8The WWN that is used for fabric logins on this VSAN. This object is used only if the value of dmEnable is false. If the value of dmEnable is true, then principal switch WWN is used. It is automatically set to the default value when set to zero-length value.
.1.3.6.1.4.1.9.9.302.1.1.1.1.9The WWN of the Principal Switch on this VSAN, or zero-length string if the identity of the principal switch is unknown.
.1.3.6.1.4.1.9.9.302.1.1.1.1.10The WWN of the local Switch on this VSAN.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.