CISCO-CLUSTER-MIB

AI MIB Summary

The CISCO-CLUSTER-MIB enables centralized SNMP management of Cisco Catalyst switch clusters by exposing configuration and status metrics for command switches and their member expansion switches. It facilitates the monitoring of cluster topology, member synchronization states, and the propagation of management credentials (SNMP communities, passwords) from the command switch to cluster members.

The MIB module for the management of a group of devices called a 'cluster'. A cluster comprises: 1. A command switch, which is a device that can provide a single point of management (including SNMP, Web Console and CLI/Telnet Console) for the devices in the cluster; 2. Zero or more expansion switches, or called the cluster members throughout the context of this MIB, which are devices that can be managed via a command switch. The command switch is also considered as a cluster member. Thus it has an entry in the MIB tables defined below for cluster members. Only the command switch IP address, passwords, and SNMP community strings need to be configured in order to provide management access to members of the cluster. The Entity MIB is cross-referenced from this MIB for some of its table entries, which contain useful information about a cluster. For example, in the Entity MIB, there is the logical table which contains the community string. This information is used to access detailed management information for some logical entity (the cluster, in this case). To determine if a particular device can be a command switch or a member switch please refer to the device's user's guide.
Main OID:
ciscoClusterMIB.1.3.6.1.4.1.9.9.134
32
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

32 total
Object Name
ciscoClusterMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.134
ciscoClusterMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.134.1
ccStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.134.1.1
ccStatusClusterNamerw
SnmpAdminString
.1.3.6.1.4.1.9.9.134.1.1.1
ccStatusClusterModero
Enumeration
.1.3.6.1.4.1.9.9.134.1.1.2
ccStatusCommanderTDomainro
TDomain (SNMPv2-TC)
.1.3.6.1.4.1.9.9.134.1.1.3
ccStatusCommanderTAddressro
TAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.134.1.1.4
ccStatusCommanderMacAddressro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.134.1.1.5
ccStatusTimeOfLastChangero
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.134.1.1.6
ccStatusLastNMSAddMemberTDomainro
TDomain (SNMPv2-TC)
.1.3.6.1.4.1.9.9.134.1.1.7
ccStatusLastNMSAddMemberTAddressro
TAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.134.1.1.8
ccStatusLastFailureAddMemberro
Enumeration
.1.3.6.1.4.1.9.9.134.1.1.9
ccStatusMaxNumberOfMembersro
Unsigned32
.1.3.6.1.4.1.9.9.134.1.1.10
ccStatusMemberOrderrw
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.134.1.1.11
ccMember
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.134.1.2
ccMemberTable
SEQUENCE OF CcMemberEntry
.1.3.6.1.4.1.9.9.134.1.2.1
ccMemberEntry
CcMemberEntry
.1.3.6.1.4.1.9.9.134.1.2.1.1
ccMemberMacAddress
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.134.1.2.1.1.1
ccMemberNumberrw
Unsigned32
.1.3.6.1.4.1.9.9.134.1.2.1.1.2
ccMemberOperStatusro
Enumeration
.1.3.6.1.4.1.9.9.134.1.2.1.1.3
ccMemberEntityLogicalIndexro
Integer32
.1.3.6.1.4.1.9.9.134.1.2.1.1.4
ccMemberRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.134.1.2.1.1.5
ccCandidate
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.134.1.3
ccCandidateTable
SEQUENCE OF CcCandidateEntry
.1.3.6.1.4.1.9.9.134.1.3.1
ccCandidateEntry
CcCandidateEntry
.1.3.6.1.4.1.9.9.134.1.3.1.1
ccCandidateMacAddressro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.134.1.3.1.1.1
ciscoClusterMIBNotificationsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.134.2
ciscoClusterMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.134.2.0
ccStatusMemberStatusChange
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.134.2.0.1
ciscoClusterMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.134.3
ciscoClusterMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.134.3.1
ciscoClusterMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.134.3.2

CISCO-CLUSTER-MIB Technical Reference Overview

The CISCO-CLUSTER-MIB SNMP MIB module published by Cisco defines 32 managed OID objects, including 17 scalar/column metrics, 2 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.134. Key tabular structures include ccMemberTable, ccCandidateTable. Monitored SNMP traps/notifications include ccStatusMemberStatusChange.

Key OID Definitions in CISCO-CLUSTER-MIB

ciscoClusterMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.134

The MIB module for the management of a group of devices called a 'cluster'. A cluster comprises: 1. A command switch, which is a device that can provide a single point of management (including SNMP, Web Console and CLI/Telnet Console) for the devices in the cluster; 2. Zero or more expansion switches, or called the cluster members throughout the context of this MIB, which are devices that can be managed via a command switch. The command switch is also considered as a cluster member. Thus it has an entry in the MIB tables defined below for cluster members. Only the command switch IP address, passwords, and SNMP community strings need to be configured in order to provide management access to members of the cluster. The Entity MIB is cross-referenced from this MIB for some of its table entries, which contain useful information about a cluster. For example, in the Entity MIB, there is the logical table which contains the community string. This information is used to access detailed management information for some logical entity (the cluster, in this case). To determine if a particular device can be a command switch or a member switch please refer to the device's user's guide.

ccMemberTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.134.1.2.1

This table contains one row per cluster member, including the command switch.

ccCandidateTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.134.1.3.1

This table contains one row per cluster candidate, A cluster candidate is a device that is currently eligible to be added to the cluster of a command switch. A device is eligible if it satisfies the following conditions: 1. It supports the cluster management protocol. 2. It is directly connected to an existing cluster member. The entries in this table and the entries in ccMemberTable are mutually exclusive at all times. That is, any device that is a cluster member never shows up in the ccCandidateTable or is never a candidate at the same time . Also, any candidate that shows up in ccCandidateTable should not appear in ccMemberTable.

ccStatusMemberStatusChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.134.2.0.1

A cluster member status change notification is generated whenever the value of any instance of ccClusterMemberOperStatus changes after the member is completely added to the cluster.

ccStatusClusterNameSnmpAdminStringread-write
.1.3.6.1.4.1.9.9.134.1.1.1

The name of the cluster. Cluster command switch functionality is only enabled if this object is a non-NULL string. Strings containing all blanks or a NULL string will disable the cluster. This object and ccStatusClusterMode in this MIB are the only objects that will be instantiated if the command switch functionality is not enabled.

ccStatusClusterModeINTEGERread-only
.1.3.6.1.4.1.9.9.134.1.1.2

The mode of the device. A device can become a member switch only when it is added to the cluster at the command switch. For devices that do not belong to any cluster, the ccStatusClusterMode is set to 'none'.

ccStatusCommanderTDomainTDomainread-only
.1.3.6.1.4.1.9.9.134.1.1.3

Indicates the kind of transport service used by the command switch of the cluster. Possible values for this object, such as snmpUDPDomain, are defined in the Transport Mappings for SNMPv2 document (RFC 1906).

ccStatusCommanderTAddressTAddressread-only
.1.3.6.1.4.1.9.9.134.1.1.4

The transport service address of the command switch of the cluster. The address is formatted according to the corresponding value of ccStatusCommanderTDomain. For snmpUDPDomain, a TAddress is 6 octets long, the initial 4 octets containing the IP-address in network-byte order and the last 2 containing the UDP port in network-byte order. Consult 'Transport Mappings for Version 2 of the Simple Network Management Protocol' (RFC 1906) for further information on snmpUDPDomain.

ccStatusCommanderMacAddressMacAddressread-only
.1.3.6.1.4.1.9.9.134.1.1.5

The management MAC address of the command switch of the cluster.

ccStatusTimeOfLastChangeTimeStampread-only
.1.3.6.1.4.1.9.9.134.1.1.6

The value of sysUpTime on the command switch when the last time the value of an instance of ccMemberOperStatus changed. The value 0 indicates that no member's status has ever changed since commander system initialization.

ccStatusLastNMSAddMemberTDomainTDomainread-only
.1.3.6.1.4.1.9.9.134.1.1.7

Indicates the kind of transport service used by the the last NMS tried to add a member to the cluster.

ccStatusLastNMSAddMemberTAddressTAddressread-only
.1.3.6.1.4.1.9.9.134.1.1.8

The transport service address of the last NMS which tried to add a member to the cluster. The address is formatted according to the corresponding value of ccStatusLastNMSAddMemberTDomain.

ccStatusLastFailureAddMemberINTEGERread-only
.1.3.6.1.4.1.9.9.134.1.1.9

The reason why the last NMS was unable to add a switch to be a member of the cluster. password: The member has an enable password configured. overmax: Adding the member exceeds the maximum number of cluster members supported by the command switch. See ccStatusMaxNumberOfMembers. noncandidate: The member is not a candidate switch, or it does not show up in the candidate table. memberNumberInUse: The member number is used by an existing member in the cluster. unreachable: The member is a candidate but is unreachable or has no connectivity.

ccStatusMaxNumberOfMembersUnsigned32read-only
.1.3.6.1.4.1.9.9.134.1.1.10

The maximum number of cluster members allowed in the cluster. The command switch is considered as a cluster member also.

ccStatusMemberOrderSnmpAdminStringread-write
.1.3.6.1.4.1.9.9.134.1.1.11

The suggested order in which the cluster members are displayed in network management applications. The format of the string is n1,n2,n3,n4, ..., where is any valid member number in the cluster. The member numbers are separated by commas with no spaces in between. An example of the object's value is '3,8,14,0,2' for a cluster containing member numbers 0, 2, 3, 8, and 14.

ccMemberEntryCcMemberEntrynot-accessible
.1.3.6.1.4.1.9.9.134.1.2.1.1

An entry containing cluster management information applicable to a particular cluster member.

ccMemberMacAddressMacAddressnot-accessible
.1.3.6.1.4.1.9.9.134.1.2.1.1.1

The management MAC address of the member device.

ccMemberNumberUnsigned32read-create
.1.3.6.1.4.1.9.9.134.1.2.1.1.2

An arbitrary value which uniquely identifies the cluster member switch number. It ranges from 1 to ccStatusMaxNumberOfMembers.

ccMemberOperStatusINTEGERread-only
.1.3.6.1.4.1.9.9.134.1.2.1.1.3

The status of cluster management connectivity between the command switch and a cluster member. Cluster management connectivity is determined by the exchange of cluster management messages between the command switch and a cluster member. A member that has failed to exchange cluster management messages with the command switch is deemed to be inactive. Otherwise, it is deemed to be active.

ccMemberEntityLogicalIndexInteger32read-only
.1.3.6.1.4.1.9.9.134.1.2.1.1.4

The value of entLogicalIndex in the ENTITY-MIB corresponding to this cluster member. Creating an entry in this table creates a corresponding entry in the entLogicalTable in the ENTITY-MIB.

ccMemberRowStatusRowStatusread-create
.1.3.6.1.4.1.9.9.134.1.2.1.1.5

The status of this conceptual row. A device is added to the cluster of a command switch by creating an entry in this table for the device. The devices currently eligible to be added into the cluster are listed in the ccCandidateTable. An attempt to add a new member may fail. See ccStatusLastFailureAddMember for possible reasons for that failure.

ccCandidateEntryCcCandidateEntrynot-accessible
.1.3.6.1.4.1.9.9.134.1.3.1.1

An entry pertaining to a single candidate device.

ccCandidateMacAddressMacAddressread-only
.1.3.6.1.4.1.9.9.134.1.3.1.1.1

The MAC address of a device qualified to to be a cluster member of the command switch cluster.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→