CISCO-CDSTV-SERVER-MIB
The CISCO-CDSTV-SERVER-MIB enables SNMP-based monitoring and configuration of Cisco Content Delivery System for TV (CDS-TV) server instances, specifically tracking role-specific metrics for Vault, Caching Node, Streamer, ISV, Controller, and Recorder roles. It provides granular visibility into ingest, storage, caching, and streaming operations, including session states, content availability, and protocol interactions (HTTP, RTSP, CCP) across the video delivery infrastructure.
Imported Objects
Objects
47 total| Object Name |
|---|
ciscoCdstvServerMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.754 |
ciscoCdstvServerMIBNotifs OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.0 |
ciscoCdstvServerMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.1 |
cdstvServerCommonObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.1.1 |
cdstvServerRolero Enumeration .1.3.6.1.4.1.9.9.754.1.1.1 |
cdstvServerPartNoro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.754.1.1.2 |
cdstvServerIDro Unsigned32 .1.3.6.1.4.1.9.9.754.1.1.3 |
cdstvServerGroupIDro Unsigned32 .1.3.6.1.4.1.9.9.754.1.1.4 |
cdstvServerHostnamerw SnmpAdminString .1.3.6.1.4.1.9.9.754.1.1.5 |
cdstvServerTTLrw Unsigned32 .1.3.6.1.4.1.9.9.754.1.1.6 |
cdstvServerDefaultStreamCacheSettings OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.1.1.7 |
cdstvServerSourceAddressTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.754.1.1.7.1 |
cdstvServerSourceAddressrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.754.1.1.7.2 |
cdstvServerCachePortrw InetPortNumber (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.754.1.1.7.3 |
cdstvCacheJumboFramesEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.754.1.1.8 |
cdstvServerOffloadEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.754.1.1.9 |
cdstvServerTransportCacheIPPkts OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.1.1.10 |
cdstvServerTransportDSCPrw Dscp (DIFFSERV-DSCP-TC) .1.3.6.1.4.1.9.9.754.1.1.10.1 |
cdstvServerTransportECNrw CiscoCdstvEcn .1.3.6.1.4.1.9.9.754.1.1.10.2 |
cdstvServerCacheDSCPrw Dscp (DIFFSERV-DSCP-TC) .1.3.6.1.4.1.9.9.754.1.1.10.3 |
cdstvServerCacheECNrw CiscoCdstvEcn .1.3.6.1.4.1.9.9.754.1.1.10.4 |
cdstvServerNullStreamingEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.754.1.1.11 |
cdstvServerStreamingObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.1.2 |
cdstvServerStartingTransportPortrw InetPortNumber (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.754.1.2.1 |
cdstvServerEndingTransportPortrw InetPortNumber (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.754.1.2.2 |
cdstvStreamJumboFramesEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.754.1.2.3 |
cdstvServerStreamGroupInfo OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.1.2.4 |
cdstvServerStreamGroupNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.754.1.2.4.1 |
cdstvServerStreamGroupIDro Unsigned32 .1.3.6.1.4.1.9.9.754.1.2.4.2 |
cdstvServerStreamerIsCacherw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.754.1.2.4.3 |
cdstvServerStorageObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.1.3 |
cdstvVaultMirrorCopiesrw Unsigned32 .1.3.6.1.4.1.9.9.754.1.3.1 |
cdstvVaultLocalCopiesrw Unsigned32 .1.3.6.1.4.1.9.9.754.1.3.2 |
cdstvServerFTPOutSettings OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.1.3.3 |
cdstvServerFTPOutInterfacerw Enumeration .1.3.6.1.4.1.9.9.754.1.3.3.1 |
cdstvServerFTPOutBandwidthrw Unsigned32 .1.3.6.1.4.1.9.9.754.1.3.3.2 |
cdstvServerFTPOutSessionsrw Unsigned32 .1.3.6.1.4.1.9.9.754.1.3.3.3 |
cdstvServerVaultGroupInformation OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.1.3.4 |
cdstvServerVaultGroupNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.754.1.3.4.1 |
cdstvServerVaultGroupIDro Unsigned32 .1.3.6.1.4.1.9.9.754.1.3.4.2 |
cdstvServerCachingObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.1.4 |
cdstvServerCacheGroupInformation OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.1.4.1 |
cdstvServerCacheGroupNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.754.1.4.1.1 |
cdstvServerCacheGroupIDro Unsigned32 .1.3.6.1.4.1.9.9.754.1.4.1.2 |
ciscoCdstvServerMIBConform OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.2 |
ciscoCdstvServerMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.2.1 |
ciscoCdstvServerMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.754.2.2 |
CISCO-CDSTV-SERVER-MIB Technical Reference Overview
The CISCO-CDSTV-SERVER-MIB SNMP MIB module published by Cisco defines 47 managed OID objects, including 31 scalar/column metrics, 0 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.754.
Key OID Definitions in CISCO-CDSTV-SERVER-MIB
.1.3.6.1.4.1.9.9.754This MIB module defines server configuration that faciliate the management of the Cisco Content Delivery System for TV (CDS-TV) product family. CDS-TV is a suite of products and software applications providing ingest, storage, caching, streaming, playout and on-demand delivery of video to television or set-top-box clients. Abbreviations: CDS Content Delivery System CDSM Content Delivery System Manager ISA Interactive Services Architecture ISV Integrated Streamer-Vault FSI File Service Interface FTP File Transfer Protocol MPEG Motion Picture Experts Group MSA Managed Services Architecture NDVR Network Digital Video Recorder RTSP Real-Time Streaming Protocol STB Set-Top Box VVI Virtual Video Infrastructure Device Roles: Vault: Content delivery application responsible for ingesting and storing video content and making it available to streamers and/or caching nodes. Caching Nodes: Content delivery application responsible for caching content from vault (using CCP) and then streaming content out to streamers over HTTP or CCP. Streamer: Content delivery application responsible for streaming video out to STB's. ISV: Content delivery application capable of acting as both a vault and as a streamer in a single device. Controller (also called 'CDSM'): CDS application providing a web-based interface for monitoring, control and configuration of CDS devices(streamers, vaults, caching nodes and ISV's), device arrays/groups, and the complete CDS deployment. Recorder: Content delivery application responsible for recording NDVR content and delivering it to streamers. Role-specific objects: cdstvServerCommonObjects apply to all roles cdstvServerStreamingObjects apply to streamer and ISV role specified by cdstvServerRole cdstvServerStorageObjects apply to vault and ISV role specified by cdstvServerRole cdstvServerCachingObjects apply to cachingserver role specified by cdstvServerRole
.1.3.6.1.4.1.9.9.754.1.1.1This object indicates the type/role of this server: isv(1) - Cisco CDS Integrated Streamer Vault vault(2) - Cisco CDS Vault streamer(3) - Cisco CDS Streamer controller(4) - Cisco CDS Manager (CDSM) cachingserver(5) - Cisco CDS Caching Node/Server recorder(6) - Cisco CDS Recorder
.1.3.6.1.4.1.9.9.754.1.1.2This object indicates the part number of this device, which uniquely identifies the type of hardware this CDS application is running on, for example, CDE-420 2S3.
.1.3.6.1.4.1.9.9.754.1.1.3This object indicates the unique server ID assigned to this device. Server ID's are auto-assigned by the CDS when servers are configured and are used to uniquely identify, optionally with the group ID, a device in the CDS.
.1.3.6.1.4.1.9.9.754.1.1.4This object indicates the group ID of the group this server belong to. Group ID's are auto-assigned when server groups are configured in the CDS.
.1.3.6.1.4.1.9.9.754.1.1.5This object specifies the optional fully qualified hostname for this server, for example, vault.cisco.com.
.1.3.6.1.4.1.9.9.754.1.1.6This object specifies the IP time to live (TTL) for data packets.
.1.3.6.1.4.1.9.9.754.1.1.8This object specifies the status of jumbo frames on cache interfaces: 'true' - Jumbo frames are enabled 'false' - Jumbo frames are disabled
.1.3.6.1.4.1.9.9.754.1.1.9This object specifies the current offload status of the server. When Server Offload is enabled, the server is configured not to accept new provisioning. 'true' - Server offload is enabled 'false' - Server offload is disabled
.1.3.6.1.4.1.9.9.754.1.1.11This object specifies whether the streaming of null MPEG files is allowed or not: 'true' - Null MPEG streaming is allowed. 'false' - NUll MPEG streaming is not allowed.
.1.3.6.1.4.1.9.9.754.1.2.1This object specifies the beginning default UDP port number used for stream and stream/cache interfaces on this streamer or ISV.
.1.3.6.1.4.1.9.9.754.1.2.2This object specifies the ending default UDP port number used for stream and stream/cache interfaces on this streamer or ISV.
.1.3.6.1.4.1.9.9.754.1.2.3This object specifies the status of jumbo frames on stream interfaces of this streamer or ISV: 'true' - Jumbo frames are enabled. 'false' - Jumbo frames are disabled.
.1.3.6.1.4.1.9.9.754.1.2.4.1This object indicates the name of the stream group this streamer or ISV is a member of. Group name for a stream group is configured in the CDSM.
.1.3.6.1.4.1.9.9.754.1.2.4.2This object indicates the ID of the stream group this streamer or ISV is a member of. Stream group ID is auto-assigned by CDS when the stream group is created.
.1.3.6.1.4.1.9.9.754.1.2.4.3This object specifies whether 'Streamer Is Cache' is enabled on this streamer. If 'Streamer Is Cache' is enabled, the Streamer can be used as a possible cache-fill source by a Streamer in a different Stream Group. All Stream Groups that have at least one Streamer with 'Streamer is Cache' enabled are displayed on the 'Stream to Cache Map' page, where the Stream Group can be selected as a possible cache-fill source and given a preference. Only the Streamers with 'Streamer Is Cache' enabled are used as possible cache-fill sources. The protocol used for cache-fill responses from Streamers is always CCP. 'true' - 'Streamer Is Cache' is enabled 'false' - 'Streamer Is Cache' is disabled
.1.3.6.1.4.1.9.9.754.1.3.1This object specifies the number of content copies on a Vault or ISV that will ensure there is at least one copy at each site.
.1.3.6.1.4.1.9.9.754.1.4.1.1This object indicates the name of the cache group this Caching Node is a member of. Group name for a caching group is configured in the CDSM.
.1.3.6.1.4.1.9.9.754.1.4.1.2This object indicates the ID of the caching group this Caching Node is a member of. Caching Group ID is auto-assigned by the CDS when a caching group is created.
.1.3.6.1.4.1.9.9.754.1.3.2This object specifies the number of local copies on a Vaults or ISV at a site.
.1.3.6.1.4.1.9.9.754.1.3.3.1This object specifies whether the management interface or the ingest interface is used for FTP pull and FTP push on a Vault or ISV. management(1) - Management interface is used for FTP pull and FTP push ingest(2) - Ingest interface is used for FTP pull and FTP push
.1.3.6.1.4.1.9.9.754.1.3.3.2This object specifies the maximum bandwidth allowed for FTP functionality on a Vault or ISV.
.1.3.6.1.4.1.9.9.754.1.3.3.3This object specifies the maximum number of FTP out sessions allowed on a Vault or ISV.
.1.3.6.1.4.1.9.9.754.1.3.4.1This object indicates the name of the vault group this Vault is a member of. Group name for a vault group is configured in the CDSM.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.